Search PubMed⌕ Search

Biomedical subjects

J Maddahi

Publications and source records attributed to J Maddahi.

At least 55 records · Page 3Linked to original sources

Frequency of late reversibility in stress-redistribution thallium-201 SPECT using an early reinjection protocol.

To assess the efficacy of an early thallium-201 reinjection protocol for reducing the need for late redistribution imaging, the frequency of thallium-201 late reversibility was prospectively assessed in 62 patients who had stress-redistribution thallium-201 studies by single-photon emission computerized tomography (SPECT), and who received 1 mCi of thallium-201 reinjection immediately following stress tomographic acquisition. These patients also demonstrated greater than or equal to 2 segments with nonreversible defects at 4-hour imaging and underwent late (18-to 72-hour) redistribution imaging. When the criterion of late reversibility was defined as greater than or equal to 1 segment with a 4-hour nonreversible defect demonstrating late reversibility, late reversibility was present in 36 (58%) of the 62 patients and in 88 (24%) of 368 SPECT segments. When the criterion of greater than or equal to 2 segments was used, late reversibility was found in 21 (34%) of the 62 patients and in 73 (20%) of the 368 segments. Of the 21 patients who had greater than or equal to 2 late reversible segments, 12 (57%) exhibited late reversibility in greater than or equal to 3 segments. The frequency of detected reversible defects increased from 32% by 4-hour imaging to 48% by combined 4-hour and late imaging (p less than 0.0001). The patients who demonstrated late reversibility could not be distinguished from those who had only late nonreversible defects by analysis of the clinical, exercise, and electrocardiographic (ECG) variables.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Technetium 99m sestamibi in the assessment of chronic coronary artery disease.

Extensive work has already been performed with regard to both planar and single photon emission computed (SPECT) technetium 99m sestamibi studies. Before widespread application of optimized acquisition and processing methods, clinical results between 99mTc sestamibi and thallium 201 were remarkably similar. It is anticipated that as techniques for 99mTc sestamibi planar and SPECT imaging become optimized, improvements in sensitivity and specificity for detection of coronary artery disease, over those observed with 201TI, might be forthcoming. This expectation is based on the improved image quality inherent in the use of the 99mTc agent with its higher count rate and higher energy. This improvement in image quality may be a principal reason for laboratories to switch from 201TI to 99mTc sestamibi imaging. It is anticipated that, with improved imaging characteristics, it will be easier for the average community hospital to obtain higher quality planar or SPECT imaging using 99mTc sestamibi rather than 201TI. In addition to improved image quality, the characteristics of 99mTc sestamibi allow gated planar or SPECT perfusion images to be obtained. It has been suggested that stress-gated SPECT sestamibi studies may provide all the information contained in a stress-rest nongated 99mTc sestamibi study, thereby potentially increasing patient throughput, a major concern with SPECT. Throughput can also be increased by using dual-isotope approaches with rest 201TI and stress technetium sestamibi acquisitions, employing either separate or simultaneous imaging with which the entire study can be accomplished in less than 2 hours. With simultaneous dual-isotope acquisition, camera time can be reduced by 50%. Finally, 99mTc sestamibi offers the advantage of the ability to perform first-pass exercise ventricular function and SPECT myocardial perfusion studies with a single injection of tracer. Regarding the assessment of myocardial viability, results to date suggest a very high degree of concordance between 201TI and 99mTc sestamibi studies using either planar or SPECT acquisition techniques. Correlative rest studies with both tracers will be of particular interest, as will preoperative and postoperative and position emission tomography correlation studies.

Aged↗

A new approach to the assessment of tomographic thallium-201 scintigraphy in patients with left bundle branch block.

To determine whether a new approach to interpretation could improve the accuracy of thallium-201 single photon emission computed tomography (SPECT) for detection of left anterior descending coronary artery disease in patients with left bundle branch block, 69 patients were evaluated. Forty-four had angiographically proved coronary artery disease; the remaining 25 were considered to have a "low" (mean 13.5 +/- 6.4%, range 3.4% to 24.9%) likelihood of disease before thallium-201 scintigraphy. The conventional scintigraphic criterion for detection of left anterior descending artery disease (septal, anterior or apical defects) was compared with a new criterion that required the apex to be abnormal to indicate left anterior descending disease. The normalcy rates in the low likelihood patient group were significantly improved by using the new approach, from 16% to 80% (p less than 0.0001) by visual analysis and from 24% to 64% (p = 0.003) by quantitative SPECT polar map analysis. The sensitivity for left anterior descending disease was similar for the conventional and the new method by visual (100% vs. 94%) and quantitative (100% vs. 83%) analyses. In contrast, the specificity was significantly improved by using the new approach, from 14% to 79% (p = 0.0006) by visual analysis and 14% to 64% (p = 0.007) by quantitative analysis. In conclusion, septal and anterior thallium-201 SPECT defects are common in patients with left bundle branch block without coronary artery disease, resulting in low specificity for left anterior descending artery disease. The normalcy rates and accuracy for detection of left anterior descending coronary artery disease were significantly better when an apical defect was used as the criterion for disease.

Aged↗

The new 99mTc myocardial perfusion imaging agents: 99mTc-sestamibi and 99mTc-teboroxime.

The two new 99m (99mTc) labeled myocardial perfusion agents, 99mTc-Sestamibi and 99mTc-Teboroxime, are now available for routine clinical application. Both agents allow assessment of ejection fraction by the first-pass technique at rest or during exercise, thus providing additional information not available with thallium-201. 99mTc-Sestamibi has long myocardial residence time, as well as adequate myocardial extraction, providing images of higher count density and superior quality compared with thallium-201. 99mTc-Teboroxime has excellent myocardial uptake characteristics but is cleared very rapidly from the myocardium. Both tracers have shown results similar to those obtained with thallium-201 for detection of coronary artery disease and the assessment of defect reversibility. 99mTc-Sestamibi studies using the rest/stress imaging sequence can be accomplished in approximately 5 hours; studies using dual-isotope imaging (rest thallium-201 and stress 99mTc-Sestamibi injection) can be completed in 1 to 2 hours. Gated stress images can be performed with 99mTc-Sestamibi, providing simultaneous information of myocardial perfusion at stress and resting wall motion or thickening and allowing rapid differentiation of ischemic from infarcted tissue. Because of its slow myocardial clearance and absence of redistribution, 99mTc-Sestamibi allows uncoupling of the time of injection from the time of imaging and thus can be valuable in the evaluation of acute myocardial infarction and outcome of thrombolytic therapy. With 99mTc-Teboroxime, rapid serial studies are feasible. Pharmacologic stress and rest studies with 99mTc-Teboroxime single photon emission computed tomography potentially can be completed in under 30 minutes.(ABSTRACT TRUNCATED AT 250 WORDS)

Coronary Disease↗

Comparison of myocardial imaging with iodine-123-iodophenyl-9-methyl pentadecanoic acid and thallium-201-chloride for assessment of patients with exercise-induced myocardial ischemia.

Iodine-123-iodophenyl-9-methyl-pentadecanoic acid [( 123I]MPDA) and thallium-201 (201Tl) were sequentially injected in 11 patients during exercise-induced myocardial ischemia. Simultaneous dual-energy planar images were obtained at 5 min, 3 and 5 hr. All studies were concordantly either positive (8/11) or negative (3/11) by both radionuclides. Exact agreement for segmental uptake was 93%, 94% and 94% for 5-min, 3- and 5-hr images, respectively. Exact agreement for defect reversibility by 3 and 5 hr were 95% and 92%. The initial defect contrasts and myocardial-to-lung ratios were similar by both agents but myocardial-to-liver ratio was lower by [123I]MPDA at 5 min, which became similar to 201Tl at 5 hr. Normal percent myocardial clearances of both agents were comparable and significantly higher than those in defect zones. Thus [123I]MPDA is suitable for myocardial imaging and correlates closely with 201Tl for initial postexercise myocardial uptake and defect reversibility. Defect reversibility appears to result from differential myocardial clearance from normal and ischemic regions.

Aged↗

Technical aspects of myocardial SPECT imaging with technetium-99m sestamibi.

Most reports to date using single photon emission computed tomography (SPECT) with technetium-99m (Tc-99m) sestamibi have used acquisition parameters that were optimized for thallium-201. To fully utilize the superior imaging characteristics of Tc-99m sestamibi, there is a need to optimize the technical aspects of SPECT imaging for this agent. Performance can be enhanced through the careful selection of optimal radiopharmaceutical doses, imaging sequences, acquisition parameters, reconstruction filters, perfusion quantification methods and multidimensional methods for visualizing perfusion distribution. The current report describes theoretical considerations, phantom studies and preliminary patient results that have led to optimized protocols, developed at Emory University and Cedars-Sinai Medical Center, for same-day rest-stress studies, given existing instrumentation and recommended dose limits. The optimizations were designed to fit a low-dose-high-dose rest-stress same-day imaging protocol. A principal change in the acquisition parameters compared with previous Tc-99m sestamibi protocols is the use of a high-resolution collimator. The approach is being developed in both prone and supine positions. A new method for extracting a 3-dimensional myocardial count distribution has been developed that uses spherical coordinates to sample the apical region and cylindrical coordinates to sample the rest of the myocardium. New methods for visualizing the myocardial distribution in multiple dimensions are also described, with improved 2-dimensional, as well as 3- and 4-dimensional (3 dimensions plus time) displays. In the improved 2-dimensional display, distance-weighted and volume-weighted polar maps are used that appear to significantly improve the representation of defect location and defect extent, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Computer Graphics↗

Myocardial perfusion imaging with technetium-99m sestamibi SPECT in the evaluation of coronary artery disease.

Technetium-99m (Tc-99m) sestamibi is a new myocardial perfusion imaging agent that offers significant advantages over thallium-201 (Tl-201) for myocardial perfusion imaging. The results of the current clinical trials using acquisition and processing parameters similar to those for Tl-201 and a separate (2-day) injection protocol suggest that Tc-99m sestamibi and Tl-201 single photon emission computed tomography (SPECT) provide similar information with respect to detection of myocardial perfusion defects, assessment of the pattern of defect reversibility, overall detection of coronary artery disease (CAD) and detection of disease in individual coronary arteries. Tc-99m sestamibi SPECT appears to be superior to Tc-99m sestamibi planar imaging because the former provides a higher defect contrast and is more accurate for detection of disease in individual coronary arteries. Research is currently under way addressing optimization of acquisition and processing of Tc-99m sestamibi studies and development of quantitative algorithms for detection and localization of CAD and sizing of transmural and nontransmural myocardial perfusion defects. It is expected that with the implementation of the final results of these new developments, further significant improvement in image quality will be attained, which in turn will further increase the confidence in image interpretation. Development of algorithms for analysis of end-diastolic myocardial images may allow better evaluation of small and nontransmural myocardial defects. Furthermore, gated studies may provide valuable information with respect to regional myocardial wall motion and wall thickening. With the implementation of algorithms for attenuation and scatter correction, the overall specificity of Tc-99m sestamibi SPECT should improve significantly because of a substantial decrease in the occurrence of attenuation-related image artifacts.(ABSTRACT TRUNCATED AT 250 WORDS)

Coronary Disease↗

Comparison of SPECT using technetium-99m agents and thallium-201 and PET for the assessment of myocardial perfusion and viability.

This report reviews the applications of tomographic imaging with current and new tracers in assessing myocardial perfusion and viability. Multiple studies with thallium-201 (TI-201) single photon emission computed tomography (SPECT) imaging for the detection of coronary artery disease (CAD) have demonstrated high sensitivity, high rates of normalcy and high reproducibility. In assessing viability, fixed defects are frequently detected in viable zones in 4-hour studies with TI-201 imaging. Redistribution imaging performed 18 to 72 hours after injection or reinjection of TI-201 before 4-hour redistribution imaging has been shown to improve accuracy of viability assessment. TI-201 SPECT studies are limited by the suboptimal physical properties of TI-201, which result in variable image quality. The 2 new technetium-99m (Tc-99m) - labeled myocardial perfusion tracers offer the ability to inject much higher amounts of radioactivity, making it possible to assess ventricular function as well as myocardial perfusion from the same injection of radiotracer. Tc-99m sestamibi has very slow myocardial clearance, which allows for prolonged imaging time and results in image quality superior to that obtained with TI-201 and Tc-99m teboroxime. The combination of minimal redistribution of Tc-99m sestamibi and high count rates makes gated SPECT imaging feasible, and also permits assessment of patients with acute ischemic syndromes by uncoupling the time of injection from the time of imaging. The combination of high image quality and first-pass exercise capabilities may lead to a choice of this agent over TI-201 for assessment of chronic CAD.(ABSTRACT TRUNCATED AT 250 WORDS)

Coronary Disease↗

Significance of dipyridamole-induced transient dilation of the left ventricle during thallium-201 scintigraphy in suspected coronary artery disease.

The occurrence and significance of transient dilation of the left ventricle during dipyridamole stress-redistribution thallium-201 scintigraphy was studied in 73 patients who underwent both dipyridamole thallium-201 study and coronary angiography. Transient dilation ratio was calculated from planar anterior images by dividing the computer-derived left ventricular area on the initial image by that of the 4-hour image. In 11 patients with normal coronary arteriograms or less than 50% coronary stenosis, the transient dilation ratio was 0.98 +/- 0.046. An abnormal transient dilation ratio was defined as greater than or equal to 1.12, representing greater than or equal to 3 standard deviations above the mean normal value. When the 15 patients with an abnormal ratio were compared with the 58 with a normal ratio, the former group had a significantly higher frequency of 3 critical (greater than or equal to 90%) coronary stenoses (33 vs 5%), higher prevalence of collaterals (67 vs 24%), more extensive myocardial reversible defects by planar (71 vs 10%) or by single-photon emission computed tomography (87.5 vs 35%) imaging and a higher incidence of dipyridamole-induced anginal chest pain (53 vs 22%). No significant difference between the 2 groups was noted with respect to age, gender, prior myocardial infarction, single or double critical coronary stenosis, dipyridamole-induced ischemic electrocardiographic response and increased lung uptake. An abnormal transient dilation ratio of greater than or equal to 1.12 was a specific marker of multivessel (87%) or 3-vessel (85%) critical coronary artery disease.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Quantitative exercise thallium-201 rotational tomography for evaluation of patients with prior myocardial infarction.

The utility of stress-redistribution thallium-201 myocardial perfusion single-photon emission computed tomography (SPECT) in patients with a prior single myocardial infarction was studied in 66 patients who were tested by both SPECT and coronary angiography. SPECT was quantified by comparing the patients' circumferential count profiles to a previously established normal data base and by plotting the results onto a polar coordinate map that localized defects to the 3 major coronary artery territories. The pattern of reversibility of the quantitatively detected defects was assessed by consensus visual analysis. SPECT thallium-201 detected myocardial infarction in 62 of 66 patients (sensitivity = 94%). Sixty-five percent of the infarct zones showed some reversibility at 4-hour imaging which corresponded with angiographic evidence of flow to the infarct zones in 95.5% of cases. Late (18 to 24 hours) imaging, done in 26 patients, showed complete or partial reversibility of 29% of infarct zone segments which were nonreversible on 4-hour images. To improve specificity for detection of disease in coronary arteries supplying the non-infarct territories, new quantitative criteria were developed that took into consideration contiguity of defects with the infarct zone. Accuracy for detection of patients with multivessel coronary disease by quantitative thallium-201 SPECT was 86%, which was significantly higher than those of the clinical response to exercise (48%), the exercise electrocardiographic response (56%) or their combination (65%).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Critically ischemic myocardium in clinically stable patients following thrombolytic therapy for acute myocardial infarction: potential implications for early coronary angioplasty in selected patients.

The utility of post-thrombolysis, rest-redistribution thallium (TI)-201 scintigraphy was studied in 32 patients with a first myocardial infarction who were clinically stable following reperfusion. Day 1 scintigraphy obtained 5 +/- 4 hours (range 1 to 16) after thrombolysis revealed an average perfusion defect of 6.5 +/- 2.6 segments (range 1 to 11). There was a total of 208 abnormal segments, 137 of which were nonreversible at 4 hours, 50 of which were fully or partially reversible, and 21 of which had a reverse redistribution pattern. Repeat TI-201 scintigraphy on day 10 revealed significantly smaller perfusion defects of 4.9 +/- 2.4 segments (range 0 to 9) with improvement predominantly of the day 1 reversible segments, and the improvement in segmental perfusion correlated with better regional left ventricular function. Twenty-nine (58%) of the 50 reversible segments normalized by day 10, and 11 (22%) improved, whereas only 16 (12%) of 137 nonreversible segments had normalized by day 10, only 9 had (6%) improved and 112 (82%) were unchanged (p less than 0.001 reversible versus nonreversible). There was no significant change in segments with a pattern of reverse redistribution. The improvement of reversible segments was greater in the 16 patients who underwent coronary angioplasty (PTCA) during the interval between the two scintigrams than in the 16 who did not. All 24 reversible segments in the PTCA group improved or normalized by day 10 compared with 16 (62%) of 26 reversible segments in the No PTCA group (p less than 0.001). Furthermore, 8 of the 10 reversible segments in the No PTCA group that did not improve actually deteriorated and became nonreversible by day 10. The minor improvement of nonreversible segments was not related to PTCA. Consistent with the findings in individual segments, the 19 patients with a reversible component on the day 1 TI-201 scintigram had significantly greater improvement in perfusion defect by day 10 than the 13 patients without a reversible component (37 +/- 33% versus 7 +/- 22% decrease in perfusion defect severity, p less than 0.05), and this improvement was greatest in the 10 patients with a reversible component who underwent PTCA. In contrast, PTCA had no impact on the perfusion defect in the 13 patients without a reversible component. Our data suggest that following thrombolytic therapy for acute myocardial infarction, viable myocardium in the reperfused zone may remain ischemic, as manifested by a reversible pattern of TI-201 redistribution at rest, and thus may be in jeopardy of gradual progression to necrosis.(ABSTRACT TRUNCATED AT 400 WORDS)

Adult↗

Development and prospective application of quantitative 2-day stress-rest Tc-99m methoxy isobutyl isonitrile SPECT for the diagnosis of coronary artery disease.

The clinical diagnostic accuracy of 2-day stress/rest quantitative Technetium-99m (Tc-99m) methoxy-isobutyl-isonitrile (Tc-sestamibi) single photon emission computerized tomography (SPECT) was assessed in a validation population of 61 patients from two different sites using two different camera/computer systems. The study population was made up of 53 catheterized patients, 29 from Cedars-Sinai Medical Center (CSMC) and 24 from the University of Texas Southwestern Medical Center (UTSMC), and eight UTSMC patients with a less than 5% pre-test likelihood of coronary artery disease. Interpretation employed gender-specific normal limits developed in an additional 15 men and 8 women at CSMC with less than a 5% likelihood of significant coronary artery disease. The results from CSMC compared with those from UTSMC were not different from each other. The overall sensitivity for detection of patients with coronary artery disease (greater than or equal to 50% stenosis) was 94% (CSMC: 92%, UTSMC: 95%). Overall specificity in the five patients with normal coronary arteriograms was 80% (CSMC: 67%, UTSMC: 100%). The normalcy rate in patients with a low likelihood of coronary artery disease was 88%. Vessel sensitivity was 85% (CSMC: 84%, UTSMC: 85%), while vessel specificity was 71% (CSMC: 72%, UTSMC: 69%). There was also no significant difference in the sensitivities and specificities between male and female populations. In addition, the agreement with coronary angiography for assessment of disease extent (normal coronary arteriogram, single or multivessel disease) was 75% (kappa = 0.6 +/- 0.1). This study demonstrated that Tc-sestamibi SPECT by quantitative analysis is accurate for the detection and localization of coronary artery disease. Furthermore, the CSMC quantitative method was shown to provide similar diagnostic accuracy when applied to data acquired at a different site using a different camera/computer system.

Adult↗

The frequency of late reversibility in SPECT thallium-201 stress-redistribution studies.

The frequency of thallium-201 late reversibility was prospectively assessed in 118 patients who had stress-redistribution thallium-201 studies by single photon emission computed tomography (SPECT). These patients demonstrated two or more segments with nonreversible defects at 4 h imaging and underwent late (18 to 72 h) redistribution imaging. When the criterion of late reversibility was defined as greater than or equal to 1 segment with 4 h nonreversible defects demonstrating late reversibility, it was present in 62 (53%) of the 118 patients and 164 (22%) of 762 segments. When the criterion of greater than or equal to 2 segments was used, late reversibility was found in 41 (35%) of 118 patients and 143 (19%) of 762 segments. The frequency of detected reversible defects increased from 27% at 4 h imaging to 43% at combined 4 h and late imaging (p less than 0.0001) and was significantly increased in all myocardial regions. In comparing the efficacy of initial and late imaging alone versus performing initial, 4 h and late imaging for the identification of reversible defects, 421 (94%) of 449 segments classified as reversible by the latter protocol were also correctly identified by the early and late imaging only approach, with the remaining 6% (28 segments) comprising those segments demonstrating the reversible pattern at 4 h and the nonreversible pattern at late imaging. No major differences were noted with respect to clinical, stress electrocardiographic and scintigraphic variables between the 118 patients undergoing late imaging and 98 additional randomly selected patients with two or more nonreversible defects at 4 h, who did not have late imaging.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Quantitative analysis of tomographic stress thallium-201 myocardial scintigrams: a multicenter trial.

The accuracy of the previously developed and validated Cedars-Sinai Medical Center (CSMC) computer program for quantitative analysis of thallium-201 (201TI) stress myocardial tomograms was assessed in a multicenter trial consisting of 242 patients with coronary angiography and 76 with a low likelihood (LL) of coronary artery disease (CAD) involving various cameras, computers, and operators. The program utilized gender-matched normal limits developed from 35 LL patients at CSMC. The multicenter results as compared to those of 168 patients from CSMC were not significantly different with respect to the overall sensitivities (94% versus 95%) and specificities (44% versus 56%) for identification of CAD and normalcy rates which were determined in LL patients (82% for both) and with respect to identification of individual diseased arteries. The results indicate that our method for quantifying tomographic 201TI stress scintigrams utilizing standard normal limits can be applied at other institutions by different operators, using a variety of cameras and computers, with similar accuracy to that currently obtained at our institution.

Coronary Disease↗

Comparison of myocardial washout rate of thallium-201 between rest, dipyridamole with and without aminophylline, and exercise states in normal subjects.

The myocardial washout rate of thallium-201 was studied in 85 subjects with a less than 5% likelihood of coronary artery disease undergoing rest (group I, n = 12), dipyridamole (group II, n = 24) and exercise (group III, n = 49) stress thallium-201 scintigraphy. Subjects receiving dipyridamole were subdivided into group IIA (n = 11), who received an aminophylline injection 10 minutes after dipyridamole infusion, and group IIB (n = 13), who did not. The mean and highest washout rate values in each of 3 segments in the anterior, 45 degrees and 85 degrees left anterior oblique views were calculated. In group II the mean washout rate of thallium-201 was similar in all segments of each view and the overall mean washout rate did not differ between the 3 views studied. There was a good correlation between the mean and highest washout rate values in individual subjects (r = 0.98, p less than 0.001). The mean +/- standard deviation myocardial 4-hour washout rate of thallium-201 (anterior view) was 10 +/- 6% in group I compared with 40 +/- 14% in group IIA (p less than 0.05 vs group I), 31 +/- 13% in group IIB (p less than 0.05 vs group I) and 54 +/- 11% in group III (p less than 0.05 each vs group IIA and group IIB, respectively). There was a wide variation in mean washout rate values in group II (range 12 to 58%), and this variation was not altered by aminophylline administration.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Exercise thallium-201 scintigraphy and prognosis in typical angina pectoris and negative exercise electrocardiography.

Patients with a history of typical angina but negative exercise electrocardiography represent a subgroup with an intermediate likelihood of having coronary artery disease and future cardiac events. A retrospective study of the prognostic utility of stress-redistribution thallium-201 scintigraphy was performed in 190 such patients. A second group of 203 patients with typical angina and a positive exercise electrocardiogram were analyzed for comparative scintigraphic purposes. The cardiac event rate for the 144 negative exercise electrocardiogram patients with normal thallium results was 5 vs 15% in the 46 patients with abnormal thallium results (p = 0.01). These patients were further stratified into high (14 to 18%), intermediate (9%) and low (less than 2%) risk groups for future cardiac events based on combining the thallium results with the percentage of maximal predicted heart rate achieved. A multivariate analysis revealed that an abnormal thallium result was the only significant correlate of future cardiac events. Mechanisms responsible for the discordant finding of a negative exercise electrocardiogram in patients with typical angina include (1) false-positive angina symptomatology in low prevalence coronary artery disease groups in whom the thallium test is negative, and (2) "electrocardiographically silent" ischemia in patients in whom the thallium test is positive. These findings reveal that thallium stress-redistribution scintigraphy can be used to stratify 1-year prognosis in this subgroup of patients with typical angina and negative exercise electrocardiograms.

Angina Pectoris↗

Radionuclide imaging of myocardial perfusion and viability in assessment of acute myocardial infarction.

Technical advances in radionuclide imaging have important implications for the management of patients with acute myocardial infarction. Single-photon emission computerized tomography with thallium 201 (TI-201) offers greater accuracy than planar imaging in detecting, localizing and sizing myocardial perfusion defects. Use of single-photon emission computerized tomography with TI-201 should allow for a more accurate assessment of prognosis after myocardial infarction. A new radiopharmaceutical, technetium 99-m methoxyisobutyl isonitrile, provides a number of advantages over TI-201, including higher quality images, lack of redistribution, and the ability to assess first-pass ventricular function. Applications of TI-201 and technetium 99-m methoxyisobutyl isonitrile include assessment of arterial patency and myocardial salvage immediately after thrombolytic therapy, detection of resting ischemia after thrombolytic therapy, targeting of subsets of patients for further intervention, and predischarge assessment to predict the future course of patients after an acute myocardial infarction.

Coronary Circulation↗