Bundle branch reentry tachycardia and possible sustained interfascicular reentry tachycardia with a shared unusual induction pattern.

A case of bundle branch reentry tachycardia with an unusual induction pattern is presented. Unlike typical cases of this arrhythmia in which tachycardia is usually inducible with routine programmed ventricular stimulation and/or short-long sequences, tachycardia in this case was inducible only with atrial stimulation. It also arose spontaneously during atrial flutter and during isoproterenol administration. After ablation of the right bundle, possible interfascicular reentry tachycardia with a similar induction pattern was observed. This tachycardia was successfully ablated in the region of the posterior fascicle of the left bundle branch.

Aged↗

Ventricular tachycardias with left bundle branch block morphology.

The differential diagnosis of VTs with LBBB morphology includes several well-defined syndromes. Although the majority of cases are attributable to acquired structural heart disease, including ischemia, prior infarction, or dilated cardiomyopathy, consideration of specific right ventricular processes is essential to proper evaluation and treatment. The approach to older patients or those with evidence for heart disease should begin with an evaluation for coronary artery disease and an assessment of biventricular function. Careful evaluation for bundle branch reentry should be performed during electrophysiological study, especially when there is underlying conduction system disease. Younger patients, those without overt heart disease, or those with isolated right ventricular disease, should receive a complete noninvasive evaluation of right and left ventricular size and function. An abnormal SAECG or identification of intracardiac late potentials suggest right ventricular dysplasia or cardiomyopathy, whereas responsiveness to adenosine and absence of detectable heart disease support the diagnosis of idiopathic right VT. Newer techniques, including MRI, show promise in identifying subtle right ventricular disease not otherwise detectable even in the setting of presumed idiopathic right VT. Following surgical repair of selected congenital heart defects, particularly tetralogy of Fallot, symptoms of recurrent palpitations, near syncope, syncope, or aborted sudden death may be attributable to recurrent VT, and diagnostic electrophysiological study should be considered for these patients. Finally, SVTs with LBBB morphology, particularly cases associated with right-sided or septal accessory pathways, should always be considered in this differential diagnosis.

Bundle of His↗

Radiofrequency delivery through a cooled catheter tip allows the creation of larger endomyocardial lesions in the ovine heart.

INTRODUCTION: The delivery of radiofrequency (RF) energy through conventional catheter electrodes is often associated with coagulation necrosis at the tissue-electrode interface, with resultant impedance rise and limited lesion size. This study was performed to examine the effects of catheter tip cooling during RF delivery, to test the hypothesis that such cooling would decrease the likelihood if impedance rise and allow the creation of larger endomyocardial lesions. METHODS AND RESULTS: The experiments were performed in eight open chest, anesthetized sheep. RF lesions were created within both ventricular chambers of each animal through a catheter tip that could be cooled with a saline perfusate. Assignment of cooled versus noncooled RF delivery to either ventricle was alternated from one animal to the next. In each set of experiments, lesion volumes relative to the mode of RF delivery were compared. The mean power delivered via the cooled electrode (22.04 +/- 4.51 W) was significantly higher than that delivered via the noncooled electrode (6.10 +/- 2.47 W; P < 0.001). The mean duration of RF delivery was 42.7 +/- 11.2 sec for noncooled lesions versus 49.2 +/- 6.8 sec for cooled lesions (P < 0.01). Mean lesion volume was 436.07 +/- 177.00 mm3 for noncooled RF delivery versus 1247.78 +/- 520.51 mm3 for cooled RF delivery (P < 0.001). This significantly larger lesion size with cooled RF delivery was associated with no instance of impedance rise in 27 attempts versus 11 impedance rises in 28 attempts with noncooled RF (P < 0.001). CONCLUSIONS: Delivery of RF energy through a cooled catheter tip allows the creation of larger endomyocardial lesions by limiting the occurrence of impedance rise despite the delivery of greater energy. These observations suggest that, under certain conditions, resistive tissue heating at a distance from the site of current delivery may play an important role in RF ablation therapy.

Animals↗

Implantable atrial defibrillators.

Due to the limited efficacy of antiarrhythmic drugs for atrial fibrillation, several nonpharmacologic therapeutic options have evolved. One of these is an implantable atrial defibrillator. Recent studies have shown that internal atrial defibrillation is feasible with relatively low energies. To date, the optimal electrode configuration involves large surface area catheters in the right atrium and coronary sinus. In humans, atrial defibrillation can generally be achieved with < 2 J using this electrode configuration and a biphasic shock waveform. For shocks < 5 J, there is no significant pathological damage to the atria or coronary sinus. Further investigation is needed to guarantee that atrial defibrillation shocks do not provoke ventricular arrhythmias. Preliminary data suggest that atrial defibrillation shocks synchronized to R waves that are not closely coupled are safe. In addition, the shocks are well tolerated if the shock energy is < 1.5 J. With additional studies to confirm the safety of implantable atrial defibrillators, further reduce shock energy, and improve patient tolerance, an implantable atrial defibrillator can become an acceptable therapy for patients with symptomatic, paroxysmal atrial fibrillation.

Animals↗

Catheter ablation of sinoatrial node reentrant tachycardia.

OBJECTIVES: This study evaluates 1) the safety and efficacy of catheter delivery of radiofrequency current to eliminate sustained sinoatrial node reentrant tachycardia; 2) the incidence of sinoatrial node reentrant tachycardia in the current group of patients undergoing electrophysiologic study for paroxysmal supraventricular tachycardia; and 3) the association of sinoatrial node reentrant tachycardia with other tachyarrhythmias. BACKGROUND: Sustained sinoatrial node reentrant tachycardia is an uncommon cause of paroxysmal supraventricular tachycardia that is reported to occur infrequently in conjunction with other arrhythmias. Although pharmacologic and surgical therapies are available, there is limited information with regard to catheter ablation of sinoatrial node reentrant tachycardia. METHODS: Ten patients with sustained sinoatrial node reentrant tachycardia underwent electrophysiologic study and radiofrequency current ablation. Patients were followed up for 9.2 +/- 6.0 months. RESULTS: Of 343 consecutive patients referred for electrophysiologic evaluation of paroxysmal supraventricular tachycardia, 11 (3.2%) were found to have inducible sustained sinoatrial node reentrant tachycardia. Nine of the 11 patients had other associated arrhythmias, including atrioventricular (AV) node reentrant tachycardia (6 patients), AV reciprocating tachycardia (2 patients), ectopic atrial tachycardia (2 patients) and bundle branch reentrant tachycardia (1 patient). In 10 patients, direct ablation of sinoatrial node reentrant tachycardia was attempted and was successful in all (confidence interval for failure 0-0.26). Sinoatrial node reentrant tachycardia was eliminated with a median of four radiofrequency current applications (range 1 to 10) at 20 to 30 W. Successful ablation site characteristics during sinoatrial node reentrant tachycardia included 1) atrial activation > or = 35 ms (mean 44 +/- 8 ms) before the onset of the surface P wave, 2) atrial activation > or = 20 ms (mean 28 +/- 6 ms) before the onset of high right atrial activation, and 3) significantly prolonged and fractionated electrograms (mean duration 87 +/- 21 ms). No complications were encountered, and there have been no recurrences of sinoatrial node reentrant tachycardia. CONCLUSIONS: Sinoatrial node reentrant tachycardia may be effectively and safely treated with radiofrequency current ablation at the site of earliest atrial activation.

Adult↗

Magnesium reversal of digoxin-facilitated ventricular rate during atrial fibrillation in the Wolff-Parkinson-White syndrome.

In patients with Wolff-Parkinson-White syndrome and atrial fibrillation, digoxin may increase the ventricular rate by facilitating conduction over the accessory pathway either directly by enhancing accessory pathway conduction and/or indirectly as a consequence of its effect on atrioventricular nodal conduction. Two cases are presented in which the intravenous administration of magnesium sulfate reversed digoxin facilitation of the ventricular rate to atrial fibrillation in the Wolff-Parkinson-White syndrome.

Aged↗

Why do some patients have high defibrillation thresholds at defibrillator implantation? Answers from basic research.

Implantable cardioverter defibrillators reduce the risk of sudden cardiac death in patients with ventricular tachyarrhythmias. However, for the few patients with unacceptably high defibrillation thresholds at implantation the risk of sudden death may remain high. If a small number of defibrillation attempts are used to determine a defibrillation threshold, then a high defibrillation threshold may occur in some patients due to the probabilistic nature of defibrillation: a small percentage of shocks will fail even at optimal shock strengths. Basic investigations have suggested mechanisms for high defibrillation thresholds in other patients. The extracellular potential gradients produced by a shock correlate with ability to defibrillate and may be used to classify mechanisms for high defibrillation thresholds. Computerized mapping studies have demonstrated that extracellular potential gradient fields produced by defibrillation shocks are uneven with high gradient areas close to the electrodes and low gradient areas distant from the electrodes. A high defibrillation threshold may occur because: (1) a shock creates a subthreshold potential gradient in the low gradient areas; (2) a patient has a higher minimum potential gradient threshold than other patients; or (3) a shock leads to refibrillation in the high gradient areas. This article reviews experimental evidence to support each of these three possibilities then suggests experimental and clinical investigations that may clarify the causes of high defibrillation thresholds in patients.

Defibrillators, Implantable↗

Why is catheter ablation less successful than surgery for treating ventricular tachycardia that results from coronary artery disease?

Nearly 80% of patients with coronary artery disease who have map-directed surgery for control of ventricular tachycardias require no drug therapy to prevent recurrences, while fewer than 50% of patients undergoing catheter ablation have similar outcomes. Catheter ablation will fail if arrhythmogenic sites are incompletely ablated by lesions that are too small or too far away from the reentrant pathway or if all arrhythmogenic sites are not identified. The underlying assumptions used to guide site selection are that: (a) ventricular tachycardias arise from reentrant mechanisms; (b) monomorphic ventricular tachycardias with similar QRS morphologies arise from the same pathway; (c) the ventricular tachycardia initiated during the procedure represents the patient's spontaneous arrhythmia; (d) the endocardial site that should be ablated can be identified from cardiac activation maps produced during induced ventricular tachycardia or from ancillary techniques; and (e) the patient has only one or two reentrant pathways. Relying on incorrect assumptions may account for the difference in success rates. Patients may have similar appearing ventricular tachycardias that arise from different pathways, and the entire thin layer of viable tissue between the infarct and the endocardium may contain many reentrant pathways. Some ventricular tachycardias may arise from the myocardium away from the endocardium, while others may arise from the epicardium. Small lesions may not be large enough to eliminate all possible reentrant pathways. Catheter ablation may be less successful because the lesions are inadequate, the assumptions guiding the selection of arrhythmogenic tissue are incorrect, or all arrhythmogenic sites are not identified. The primary reason catheter ablation is less successful than surgery in the treatment of ventricular tachycardias is that catheter ablation does not ablate as much tissue as is removed by surgery. The success rate of catheter ablation probably can be improved if the amount of tissue ablated is increased.

Catheter Ablation↗

Utility of transtelephonic ECG monitoring in evaluating discharges from a third-generation implantable cardioverter defibrillator.

The authors report the case of a 60-year-old man with a third-generation implantable cardioverter defibrillator whose rate-sensing lead malfunction was diagnosed only after surface loop electrocardiographic (ECG) monitor recording. The stored R-R intervals suggested an irregular ventricular rhythm, but the loop ECG monitor demonstrated inappropriate shocks delivered during sinus rhythm.

Defibrillators, Implantable↗

Radiofrequency catheter ablation of idiopathic recurrent ventricular tachycardia with right bundle branch block, left axis morphology.

Idiopathic ventricular tachycardia with right bundle branch block and left axis deviation morphology is a well described clinical syndrome. Previous studies have mapped the tachycardia focus to the inferior septal region at the base of the posterior papillary muscle of the left ventricle. We describe two typical cases in a 20-year-old man and 29-year-old woman in which the tachycardia focus was localized with endocardial mapping techniques. In both cases the ventricular tachycardia focus was ablated with application of radiofrequency current at the inferior septal region. There were no complications of the procedures. The patients remain asymptomatic over follow-up of 7 and 4 months, respectively.

Adult↗

Treatment of supraventricular tachycardias with transcatheter delivery of radiofrequency current.

Medical therapy for the treatment of supraventricular tachycardias is frequently ineffective and associated with significant side effects, whereas curative surgical approaches have generally been limited by their considerable morbidity and cost. Greater understanding of the mechanisms underlying supraventricular tachycardias has improved our ability to precisely map endocardial areas critical to arrhythmogenesis. Advances in catheter ablation techniques and particularly the use of radiofrequency current to generate thermal energy for ablation have resulted in dramatic success rates for curative catheter ablation. This review examines the physics of radiofrequency current ablation and its application to the treatment of atrial fibrillation, atrial flutter, AV nodal reentrant tachycardia, and arrhythmias associated with the Wolff-Parkinson-White syndrome. The limitations, risks, and cost-effectiveness of this technique relative to medical and surgical approaches are also evaluated.

Catheter Ablation↗

Bidisomide (SC-40230), a new antiarrhythmic agent: initial study of tolerability and pharmacokinetics.

Forty-nine healthy male volunteers received the test article for bidisomide (SC-40230) in a double-blind, placebo-controlled, dose-ranging study. Intravenous doses ranged from 0.03 to 2.5 mg/kg. There was a close relationship between the dose and the peak plasma concentration. The PR, QRS, QT, RR, and QTc intervals each demonstrated a statistically significant response to the dose administered. The PR and QRS intervals lengthened and the other intervals shortened (although to a lesser degree). The compound was well tolerated, with mild symptoms only at higher doses. Bioavailability was studied in 12 male volunteers, with each receiving 2.0 mg/kg of bidisomide, both orally and intravenously, in an open-label crossover trial. After a 10-minute zero-order intravenous infusion, bidisomide plasma levels could best be described in terms of a three-compartment pharmacokinetic model with the mean half-life values of alpha, beta, and gamma phases of 0.12, 1.77, and 12.3 hours, respectively. The mean absolute oral bioavailability was 43%.

Administration, Oral↗

Cardiac potential and potential gradient fields generated by single, combined, and sequential shocks during ventricular defibrillation.

BACKGROUND: Potential gradient field determination may be a helpful means of describing the effects of defibrillation shocks; however, potential gradient field requirements for defibrillation with different electrode configurations have not been established. METHODS AND RESULTS: To evaluate the field requirements for defibrillation, potential fields during defibrillation shocks and the following ventricular activations were recorded with 74 epicardial electrodes in 12 open-chest dogs with the use of a computerized mapping system. Shock electrodes (2.64 cm2) were attached to the lateral right atrium (R), lateral left ventricular base (L), and left ventricular apex (V). Four electrode configurations were tested: single shocks of 14-msec duration given to two single anode-single cathode configurations, R:V and L:V, and to one dual anode-single cathode configuration, (R+L):V; and sequential 7-msec shocks separated by 1 msec given to R:V and L:V (R:V----L:V). Defibrillation threshold (DFT) current was significantly lower for R:V----L:V than for the other configurations and markedly higher for L:V. Despite these differences, the minimum potential gradients measured at DFT were not significantly different (approximately 6-7 V/cm for each electrode configuration). Potential gradient fields generated by the electrode configurations were markedly uneven, with a 15-27-fold change from lowest to highest gradient, with the greatest decrease in gradient occurring near the shock electrodes. Although gradient fields varied with the electrode configuration, all configurations produced weak fields along the right ventricular base. Early sites of epicardial activation after all unsuccessful shocks occurred in areas in which the field was weak; 87% occurred at sites with gradients less than 15 V/cm. Ventricular tachycardia originating in high gradient areas near shock electrodes followed 11 of 67 successful shocks. CONCLUSIONS: These data suggest that 1) defibrillation fields created by small epicardial electrodes are very uneven; 2) achievement of a certain minimum potential gradient over both ventricles is necessary for ventricular defibrillation; 3) the difference in shock strengths required to achieve this minimum gradient over both ventricles may explain the differences in DFTs for various electrode configurations; and 4) high gradient areas in the uneven fields can induce ectopic activation after successful shocks.

Animals↗