Phase cancellation: a cause of acoustical shadowing at the edges of curved surfaces in B-mode ultrasound images.

Acoustical shadowing occurring at the edges of curved objects is one of the most frequently observed artifacts in ultrasound imaging. This artifact has been generally ascribed to refraction and reflection effects at the boundary between the curved object and the surrounding tissues. However, the shadowing that would be produced by pure refraction and reflection may not correspond in all circumstances to what is most often seen clinically, i.e., a sharp, discrete shadow projecting down from the edge. We used a tissue-mimicking contrast detail phantom, speed of sound (SOS) 1477 m/s, containing cylindrically shaped wells to investigate the origin of these shadows. Using solutions of relatively high SOS (20% ethylene glycol), approximately equivalent SOS (distilled water), and low SOS (70% isopropyl alcohol), the phantom was scanned with the scanhead face oriented perpendicular to and parallel to the central axes of the cylinders. Shadowing could be produced in both cases when there was a SOS difference between the contents of the cylinders and the phantom. When scanning perpendicular to the cylinders, refraction and reflection effects could have contributed to any shadowing produced, but when the scan planes were oriented parallel to the central axes of the cylinders, neither refraction nor reflection could be occurring to a significant degree. The shadowing produced in these circumstances could be better explained by a phenomenon well known in transmission ultrasonography called phase cancellation. Phase cancellation would produce shadowing independent of scan plane orientation, and could contribute to the shadowing generated in clinical imaging.

Acoustics↗

Pre- to postnatal reduction in ultrasound attenuation coefficient of the liver.

A recent study showed the ultrasound attenuation coefficient of fetal liver between 26 and 40 weeks of gestation to be 26% higher than after birth. To test the hypothesis that ultrasound attenuation is sensitive to fetal liver glycogen concentration, the livers of 24 fetuses were examined at 5 MHz just prior to and just after birth. The mean pre- to post-delivery reduction in attenuation coefficient was 0.08 dB cm-1 MHz-1 +/- 0.02 (SEM), or 17% of the post-delivery mean. This is consistent with the increase in attenuation measured by others in liver homogenate when glycogen was added. An increase in measurement accuracy, correlation with glycogen content, and, possibly, control for biological variability will be required to make predictions in individual cases, as opposed to these averages. A simple test of glycogen content would be of value scientifically and in prenatal and postnatal management.

Female↗

Acoustic generation of bubbles in excised canine urinary bladders.

A high-intensity, 555-kHz acoustic field was used to generate bubbles within urinary bladders excised from dogs. Following the exposure, bubbles were visualized on a diagnostic ultrasound scanner with a 5-MHz in-line mechanical sector scanhead. Scattering of the high-intensity ultrasound by the bubbles was also observed during the exposure as high-amplitude scan lines. The bladders used had been surgically removed after tying off the ureters and urethra to prevent urine loss and exposure to external contaminants. Each bladder was sealed in a plastic bag filled with a degassed saline solution. The bladder was centered in a sealed degassed water path at the common focus of a 7-cm-diam transducer and a 10-cm-diam brass reflector. The 555-kHz transducer and reflector were both focused at 10 cm and were aligned coaxially. Using various acoustic pressure amplitudes, two, 10-s low-frequency exposures, separated by approximately 30 s, occurred at approximately 2-min intervals. Experiments on a single bladder lasted as long as 45 min. The sizes of the largest bubbles, which were easily imaged, were estimated from rise velocity measurements as 50-70 microns in radius, and pressure amplitudes used to generate those large bubbles were estimated as 10-20 bars. The detection of smaller bubbles was limited by the inability to clearly distinguish bubble echoes from artifacts caused by the reverberant field within the bladder. Visual inspection of the exterior and interior bladder wall showed no significant discoloration within the high intensity beam path.(ABSTRACT TRUNCATED AT 250 WORDS)

Acoustics↗

Acute renal failure: possible role of duplex Doppler US in distinction between acute prerenal failure and acute tubular necrosis.

Ultrasonography (US) of the native kidneys is commonly requested for acute renal failure (ARF), although in most cases the examination results are negative. To detect changes in the Doppler waveform associated with ARF and determine whether Doppler US can provide significant diagnostic information not available with standard US, 91 patients with ARF were studied to determine a mean resistive index (RI) for each patient. Forty-six patients had acute tubular necrosis (ATN) with a mean RI +/- 1 standard deviation of .85 +/- .06, which was significantly higher than the mean RI of .67 +/- .09 in 30 patients with prerenal ARF (P less than .01). Fifteen patients had ARF due to non-ATN intrinsic renal disease (mean RI, .74 +/- .13). An elevated RI (greater than or equal to .75) occurred in 91% of patients with ATN versus only 20% of patients with prerenal azotemia. Patients with severe liver disease (hepatorenal syndrome) are a subset of those with prerenal ARF that accounted for most of the elevated RIs in this group. The study demonstrates that intrarenal Doppler US allows detection of changes associated with ARF far more often than standard US. More important, Doppler US may be helpful in distinguishing ATN from prerenal azotemia.

Acute Kidney Injury↗

Renal transplant pyelocaliectasis: role of duplex Doppler US in evaluation.

To distinguish the obstructed from the nonobstructed dilated collecting system of transplanted kidneys without interventional diagnostic measures, the authors prospectively evaluated duplex Doppler analysis (determination of resistive index [RI]) in 35 renal transplant patients with pyelocaliectasis. Proof of the presence or absence of obstruction was obtained at interventional procedures in 18 patients and at clinical follow-up in 17. Thirteen kidneys were obstructed (mean RI, .81 +/- .06), while 22 had nonobstructive dilatation (mean RI, .66 +/- .07). The RI difference was statistically significant (P less than or equal to .01). Of 21 kidneys with a normal RI, only two had obstruction. In both of these, the obstruction was associated with a significant peritransplant collection of fluid due to a ureteral leak. In the seven obstructed transplanted kidneys with follow-up, the mean RI was .82 +/- .06 before nephrostomy and .67 +/- .05 after nephrostomy. Obstruction was a common cause of an elevated RI (greater than or equal to .75). Other causes of transplant dysfunction can be associated with an elevated RI and nonobstructed dilatation. More important, a normal RI should strongly argue against obstruction unless a ureteral leak is also present.

Adult↗

Clean and dirty shadowing at US: a reappraisal.

Clean and dirty shadowing are common phenomena in ultrasound (US) imaging. Clean shadowing is thought to be produced by sound-absorbing materials (ie, stones), and dirty shadowing is thought to be produced by sound-reflecting materials (ie, abdominal gas), but these properties are not consistent. To evaluate the characteristics of shadows behind different objects at US, the authors scanned two renal stones and a bovine femur (each of which had part of its surface artificially smoothed or roughened) and a tissue-mimicking phantom comprising air-containing cylinders of different radii of curvature. The rougher and/or smaller the radius of curvature of the surface insonified by the sound beam, the cleaner was the shadow, independent of the composition of the underlying reflecting medium. Clean and dirty shadowing were primarily related to the properties of the surface of the shadowing object and provided little information about the structural nature of the object.

Animals↗

Intramedullary lesions of the pediatric spinal cord: correlation of findings from MR imaging, intraoperative sonography, surgery, and histologic study.

Findings of preoperative magnetic resonance (MR) imaging and radiologist-directed intraoperative sonography (IOS) were correlated with surgical and pathologic findings in 11 pediatric patients with intramedullary spinal cord lesions. There were seven gliomas and one each of primitive neuroectodermal tumor, venous vascular malformation, neuroenteric cyst, and active schistosomiasis. MR imaging provided discrete preoperative anatomic localization and excluded multicentric lesions but did not reliably distinguish between solid and cystic lesions. IOS helped (a) define the limits of intramedullary mass before the dura mater was opened and (b) differentiate cystic from solid components. The internal architecture of intramedullary lesions, as shown with MR imaging and sonography, was strikingly similar, allowing discrete correlative localization for biopsy or tissue resection. Gadolinium-enhanced MR imaging and IOS are complementary imaging techniques that should be used in concert for the evaluation and management of intramedullary lesions of the pediatric spinal cord. Both techniques display regions of cord abnormality, but neither definitively characterizes underlying tissue histology.

Adolescent↗

Doppler ultrasound color flow imaging in the study of breast cancer: preliminary findings.

A prospective study of the Doppler color flow features of 55 proved breast cancers was performed. On a three-level scale of low to marked vascularity, visual assessment of the color flow images classified 82% of the cancers as moderately or markedly vascular (minimal: 14%, moderate: 29%, marked: 53%). Four percent of the cancers had no detectable flow. In 29 women, a volume of tissue comparable to the cancer was scanned in the contralateral normal breast. Sixty-nine percent of the normal breasts had moderate or marked vascularity (minimal: 28%, moderate: 41%, marked: 28%), and 3% were avascular. There was poor distinction between normal tissues and cancer which suggests that more sensitive Doppler methods than were employed in this study may be needed in order to detect the small vessel flow reported to be rather specific for malignancy. The high, 82%, detection rate of tumor vessels in this study suggests the potential use of color flow Doppler for directing more specific but lengthy Doppler procedures.

Adult↗

Quantitative tissue motion analysis of digitized M-mode images: gestational differences of fetal lung.

Quantitative analysis of transmitted cardiac motion in fetal lung is evaluated by applying correlation techniques to digitized M-mode images in 21 patients, subdivided into two subgroups by gestational age: (I) 25-30 weeks (11 patients), and (II) greater than or equal to 35 weeks (10 patients). The corresponding numbers of M-mode images analyzed for each group are 23 and 18, respectively. This partition is expected to reflect functionally "immature" and "mature" lungs. The estimated maximum mean radial deformation per unit epicardial excursion, (r), is calculated from the two-time, spatially averaged correlation function obtained between diastolic and systolic M-mode lines. The collective results for each subgroup are (r) I = 0.79 +/- 0.11 (sem) and (r) II = 0.62 +/- 0.13 (sem). The analysis presented, albeit in a limited population, is indicative of a trend in accordance with qualitative observations of Birnholz and Farrell (1985). M-mode analysis, as indicated by Adler et al. (1989) is a potentially useful technique to quantify such tissue motion.

Female↗

Intrarenal arterial Doppler sonography in patients with nonobstructive renal disease: correlation of resistive index with biopsy findings.

The resistive index (RI), calculated from the duplex Doppler waveform, was compared with clinical and laboratory findings and the results of renal biopsy in 41 patients with nonobstructive (medical) renal disease. Kidneys with active disease in the tubulointerstitial compartment had a mean RI of 0.75 +/- 0.07. This was statistically significantly different (p less than .01) from the RI in kidneys with disease limited to the glomeruli (mean RI of 0.58 +/- 0.05). Acute tubular necrosis resulted in an elevated RI (mean RI = 0.78 +/- 0.03) as did vasculitis/vasculopathy (mean RI = 0.82 +/- 0.05). Patients with hypertension, proteinuria, or hematuria did not have kidneys with a significantly higher RI than did patients without these clinical factors. Kidneys found to be abnormally echogenic did not have an RI significantly different from kidneys of normal echogenicity. There was a weak correlation between creatinine level and RI value, reflected by a linear correlation coefficient of 0.34. In patients with normal renal RIs, the mean creatinine level was 1.7 +/- 1.7, whereas in those with abnormal RI values (greater than or equal to 0.70), the mean creatinine level was 3.7 +/- 3.6. We conclude that some forms of nonobstructive renal disease can produce changes in the Doppler waveform detectable by RI measurement. The production of Doppler waveform changes is strongly influenced by the site of the main disease within the kidneys. Active disease within the tubulointerstitial compartment (acute tubular necrosis, interstitial nephritis) or vasculitis/vasculopathy generally resulted in an elevated RI, whereas disease limited to the glomeruli, no matter how severe, did not significantly elevate the RI. Degree of renal dysfunction as indicated by serum creatinine level probably affects the Doppler waveform to some degree, but the relationship is weak.

Adolescent↗

Fetal depth and ultrasound path lengths through overlying tissues.

Measurements of minimum thicknesses, in a four-layer, overlying tissue model, on 22 pregnancies between 15 and 20 weeks gestation, yielded a global minimum and a mean of the minimum total thickness per patient of 1.7 and 2.9 cm, respectively, and a minimum and mean subcutaneous fat thickness of 0.7 and 1.4 cm. Conservative calculations of the minimum attenuation per patient, at 3.5 MHz indicated that less than 2.5% of 15 to 20 week pregnancies should fall below the lower 95% prediction line of: Attenuation (dB) = 0.10 X Maternal Weight (kg) - 3.0. The smallest calculated attenuation for any of the 21 subjects was 0.8 dB MHz-1 indicating just under a factor of two protection at 3.5 MHz of proximal fetal tissues compared with ultrasound intensities measured in water. This value is lower than those generally used in the past. The knowledge of distributions of transducer-to-fetal distances and thicknesses of overlying tissues is also important for improvement of image quality. Measurement of minimum depth of the anterior fetal thorax in 57 examinations of 25 to 40 week fetuses yielded minimum and mean values of 2.5 and 4.1 cm, respectively.

Female↗

Ultrasound detection of differences in density. Explanation of the ureteric jet phenomenon and implications for new ultrasound applications.

Flow of urine from the ureter into the bladder can be encountered during routine sonographic examination of the pelvis. The findings include a stream of hyperechogenic foci spurting into the bladder in real time with the production of a frequency shift during Doppler examination. We have demonstrated that visualization of this phenomenon, at least in part, reflects differences in density and associated compressibility changes between urine in the bladder and in the ureter, and need not be dependent upon flow velocity or other previously hypothesized parameters. The clinical utility of these reproducible and measurable phenomena is explored.

Humans↗

Pseudo-three-dimensional reconstruction of ultrasonic images of the tongue.

The purpose of the present investigation was to develop a method for the three-dimensional reconstruction of the surface of the tongue using serial ultrasonic images gathered during the production of the sustained fricative /s/. Using a phased linear array ultrasonic monitoring system, transducer position, subject position, and ultrasonic scan data were recorded simultaneously on composite video for off-line analysis. Reconstruction of a series of ultrasound images was completed using a microcomputer programmed to transform the ultrasonic image contours into three-dimensional space. Additional transformations converting the three-dimensional tongue contours into two dimensions for screen plotting were also developed. Results are discussed in light of previously reported models of the tongue surface.

Adult↗

Intracerebral arteriovenous malformations: intraoperative color Doppler flow imaging.

Color Doppler flow ultrasound (US) was used to locate and image intracerebral arteriovenous malformations (AVMs). US was deemed useful in eight of 12 patients who underwent AVM resection. Blood flow in the eight lesions was clearly evident, and major feeding arteries and draining veins, such as the superior sagittal sinus, were identified. Color Doppler flow imaging was used to differentiate adjacent hematoma from AVM in three patients, locate a small (6-mm) AVM deep in the brain in two patients, detect a deep major feeding artery in one patient, detect a residual unresected AVM in one patient, and confirm complete resection in all eight patients.

Cerebral Angiography↗