Search PubMed⌕ Search

Biomedical subjects

J M Rubin

Publications and source records attributed to J M Rubin.

At least 55 records · Page 3Linked to original sources

Neurotraumatology: ultrasonic evaluation of the central nervous system.

In this study we describe the technique of intraoperative ultrasound imaging of brain and spinal cord in trauma patients. The images are shown and their interpretation is discussed. This intraoperative imaging allows for localization of hematomas, bone fragments and indriven foreign bodies (i.e., pieces of plastic, glass, metal, etc.). Disc material and bone fragments deep to the spinal cord can be localized with this technique. Real-time ultrasound can be used to guide instruments within the brain and, thereby, provide dynamic guidance for removal of bone fragments and foreign bodies dynamically. In summary, intraoperative real-time ultrasonic imaging is of use to the neurosurgeon in the treatment of the neurotrauma patient.

Acute Disease↗

Lupus nephritis: predictive value of conventional and Doppler US and comparison with serologic and biopsy parameters.

PURPOSE: To compare conventional and Doppler ultrasound (US) with clinical and biopsy parameters used to assess disease activity and outcome in lupus nephritis and to assess the predictive value of US. MATERIALS AND METHODS: Thirty-four patients with lupus nephritis prospectively underwent laboratory and US analysis at the time of renal biopsy. US parameters were renal length, relative echogenicity, and resistive index (RI). Laboratory parameters were serum creatinine level, urinary protein level, and serum markers of disease activity. Biopsy parameters were activity index, chronicity index, and assessment of the tubulointerstitium of the kidney. Follow-up data were obtained in all patients for at least 1 year. RESULTS: Ten patients with elevated RI (>0.70) had significantly (P <.05) higher chronicity indexes and creatinine levels than the 24 patients with a more normal RI. RI correlated significantly (P <.05) with creatinine level, chronicity index, and presence of interstitial disease. Only RI and chronicity index were statistically significant predictors of a poor renal outcome. Abnormalities at conventional US were not predictive of renal outcome. A normal RI predicted a better renal outcome whether or not creatinine level was elevated. CONCLUSION: Renal Doppler US may be of greatest clinical utility when its results are apparently discordant with renal functional assessment by allowing identification of patients with higher likelihood of subsequent improvement or worsening of renal status.

Adolescent↗

Normalizing fractional moving blood volume estimates with power Doppler US: defining a stable intravascular point with the cumulative power distribution function.

PURPOSE: To normalize the power Doppler ultrasound (US) signal to the expected signal from 100% blood in the calculation of a fractional moving blood volume estimate. MATERIALS AND METHODS: To locate the signal from flowing blood with a consistent backscatter coefficient, the authors estimated the knee of the cumulative Doppler power distribution function. They used a flow-tube phantom to test the use of this knee to locate a radial position that would fall into a region of high shear stress and minimal rouleaux formation. They also studied how well the method normalized fractional moving blood volume estimates of the right renal cortex in a volunteer when simulating different body habitus and in a group of six healthy volunteers to estimate variability. RESULTS: Over five flow velocities and over undersaturated to severely oversaturated receiver gains, the calculated flow-tube area was a mean 89% +/- 7 (+/- standard deviation) of a standard. In humans, the technique normalized the fractional moving blood volume estimates over an 8-dB receiver gain variation; the mean +/- standard deviation of fractional moving blood volume estimates for the six volunteers was 37.6% +/- 3.6. CONCLUSION: Vascularity estimates with power Doppler US are feasible with a normalization scheme based on the cumulative Doppler power distribution function.

Adult↗

Renal transplant evaluation with power Doppler sonography.

This study was performed to determine if the marked variation we had previously noted in the power Doppler sonographic appearance of renal transplants correlated with disease, 22 renal transplants were scanned with power Doppler at 5 MHz, with biopsies being taken within 1 h in 17 kidneys and within 48 h in four other kidneys. Biopsy was not performed in one kidney with distal ureteral obstruction. Biopsy results were complex with many coexistent abnormalities; classification was based upon the predominant abnormality. Cortical vascularity was subjectively evaluated as normal, decreased or markedly decreased, and graded as 0, 1 or 2, respectively, and was compared with biopsy results, serum creatinine levels and resistive index. Cortical vascularity gradings were: 0 (12 cases); 1 (7 cases); and 2 (3 cases). The large number of disease categories (cellular rejection, 11 cases; vascular rejection, 5 cases; IgA nephropathy, 1 case; cyclosporin toxicity, 3 cases; obstruction, 1 case; and lupus nephropathy, 1 case) in relation to the number of vascular grades and number of kidneys precluded statistical analysis of cortical vascularity for rejection. However, vascularity did not appear to correlate with rejection, the three severest cases of vascular rejection having normal (grade 0) vascularity. There was no statistically significant correlation of vascular grade with creatinine levels or resistive index. In conclusion, subjective analysis of the power Doppler sonographic appearance of renal transplants does not appear to aid in their evaluation.

Adolescent↗

Use of Doppler sonography for revealing hepatic artery stenosis in liver transplant recipients.

OBJECTIVE: The goal of our study was to evaluate the use of duplex Doppler sonography for revealing hepatic artery stenosis (HAS) in patients who have undergone liver transplantation. MATERIALS AND METHODS: Forty-six patients with spectral Doppler waveforms obtained from the hepatic artery and with subsequent arteriography were reviewed retrospectively. Arterial waveforms, resistive indexes (RIs), and systolic acceleration times (SATs) were evaluated by one reviewer who was unaware of the arteriographic findings. The mean interval between the two examinations was 2.8 days. Arteriograms that revealed a stenosis of greater than 50% were classified as abnormal. RESULTS: Of the 46 patients, 21 (46%) had a significant stenosis. Patients who had HAS had significantly (p < .05) prolonged SATs (0.08 +/- 0.03 sec versus 0.06 +/- 0.02 sec) and reduced RIs (0.49 +/- 0.05 versus 0.66 +/- 0.05) compared with patients who did not have HAS. Optimal thresholds for HAS detection were RIs less than 0.55 and SATs greater than 0.08 sec. HAS was found in 14 of 15 patients who had both abnormal RIs and SATs. Of the remaining 31 patients, 12 had abnormal values for RI or SAT. Of these 12 patients, three had HAS. Thus, 19 patients had normal RIs and SATs; however, four of these patients were found to have an arterial stenosis. In our 46 patients, abnormal values for both RI and SAT were 67% sensitive and 96% specific for stenosis. When at least one abnormal value was found on Doppler imaging, sensitivity and specificity for stenosis were 81% and 60%, respectively. CONCLUSION: Duplex Doppler imaging can noninvasively reveal HAS. Abnormal values for both RI and SAT proved to be a more accurate predictor of stenosis than either RI or SAT as independent parameters.

Adult↗

Power Doppler sonography: use in measuring alterations in muscle blood volume after exercise.

OBJECTIVE: The purpose of this study was to show the ability of power Doppler sonography (PDS) to evaluate exercise-induced changes in muscle blood volume. SUBJECTS AND METHODS: We evaluated 20 biceps muscles with PDS in 10 healthy volunteers before and after they underwent a standardized exercise protocol. Intramuscular blood volume was qualitatively analyzed using a subjective scoring system to evaluate vascular conspicuity, comparing sonograms obtained before and after exercise. We also collected preliminary data on the quantification of estimated fractional moving blood volume (EFMBV) measured on sonograms obtained in eight biceps muscles of five volunteers. Assessment of significance was calculated using a Wilcoxon signed-rank correlation of significance. The stability of relative changes in EFMBV was also assessed with measurements performed at three different times in five healthy volunteers. RESULTS: With exercise, all 20 biceps muscles showed a significant subjective increase in apparent vascularity (p < .0005). Likewise, preliminary data on EFMBV showed significant increases (p < .01) between baseline and peak exercise values (mean, 470%; range, 180-900%). CONCLUSION: PDS revealed marked increases in intramuscular vascular conspicuity after exercise. EFMBV provided a potentially useful parameter to document such increases quantitatively.

Adult↗

Autocorrelation of integrated power Doppler signals and its application.

The integrated power Doppler signal arising from blood flow is a random process. In this article, a general approach to model this random process is studied. Both the theoretical and experimental results show that the temporal autocorrelation function of the integrated power Doppler signals is directly related to properties of the insonified medium, such as the scattering strengths and velocities of all moving scatterers, and as well as the properties of the Doppler imaging system, such as the point spread function (psf) of the power Doppler images. Some initial experiments are performed to test the proposed model. Its potential application for flow measurement, such as perfusion evaluation, is also discussed.

Blood Flow Velocity↗

The hemodynamics of transjugular intrahepatic portosystemic shunts: investigations with Doppler sonography and development of an in vitro model.

RATIONALE AND OBJECTIVES: We evaluated Doppler sonography-based measurements of transjugular intrahepatic portosystemic shunt (TIPS) function and developed an in vitro model of normal TIPS hemodynamics. METHODS: We reviewed retrospectively the results of all trans-TIPS manometries (N = 116) performed during a 24-month period. Portosystemic pressure gradient was compared with peak stent velocity as measured by angle-corrected Doppler sonography. A flow phantom simulating TIPS was created using 8-, 10-, and 12-mm-diameter wire-mesh stents placed in cylindrical channels with lengths ranging from 3.4 to 6.0 cm. RESULTS: Among 50 trans-TIPS manometries with corresponding Doppler sonography performed on well-functioning shunts, measured portosystemic pressure gradient and peak velocity were not correlated (R2 = .014). On the basis of a regression of measurements in the flow phantom, pressure loss in a stented cylindrical channel was estimated as follows: delta p = rho.(0.145 -0.001.Rey + 0.816.L/D).(Vmean2/2), where rho is the fluid density, Rey is the Reynolds number, L is the channel length, D is the stent diameter, and Vmean is the time-averaged velocity within the stent. Predicted and measured pressure gradients were correlated (R2 = .91). CONCLUSION: Peak velocity in patients with a normally functioning TIPS does not predict the magnitude of the portosystemic pressure gradient.

Blood Flow Velocity↗

Hepatic hemodynamic alterations after administration of oral CT contrast agents.

PURPOSE: To assess the effects of oral computed tomography (CT) contrast agents on hepatic hemodynamics with duplex Doppler ultrasound (US). MATERIALS AND METHODS: Thirty healthy subjects who fasted underwent duplex Doppler US of the hepatic artery and portal vein both before and after administration of oral CT contrast agents. Resistive indexes were determined for the hepatic arteries. Peak and mean velocity (centimeters per second) and mean diameter were calculated for the main portal vein. RESULTS: Statistically significant elevation of the resistive index (P < .01) of the hepatic arteries was observed after ingestion of oral CT contrast agents. Increase in the mean resistive index at 15 minutes was 12% in the proper hepatic arteries and 20% in the intrahepatic arteries. There was a postprandial increase in mean portal venous flow compared with baseline levels (1,110 mL/min +/- 210 vs 940 mL/min +/- 140) (P < .05). CONCLUSION: An elevation of hepatic artery resistance that is probably due to arterial vasoconstriction after ingestion of oral CT contrast agents can be observed with Doppler US. Hemodynamic changes in liver vasculature after ingestion of oral CT contrast agents may have as yet unknown implications for CT scanning of the liver.

Administration, Oral↗

Endobronchial ultrasound-guided needle aspiration of mediastinal adenopathy.

We conducted a randomized, controlled trial to prospectively confirm that ultrasound-directed transbronchial needle aspiration (USTBNA) results in: (1) improved sensitivity for detecting lymph nodes involved with neoplasm, and (2) a decreased number of aspirates needed to achieve a diagnosis as compared with standard transbronchial needle aspiration (TBNA). The study was conducted in a tertiary medical center on patients undergoing fiberoptic bronchoscopy in the evaluation of enlarged mediastinal lymph nodes. USTBNA or TBNA were followed by rapid, on-site cytopathology examination of the collected specimens. Measurements included the (1) age and sex of the patient, prior diagnosis of cancer, nodal short-axis diameter and node location as determined by computerized tomography (CT), and endobronchial abnormalities at bronchoscopy; (2) number, order, and location of transbronchial aspirates and results of on-site evaluation; (3) results of surgical exploration in patients with negative transbronchial needle aspiration; (4) sensitivity, specificity, and diagnostic accuracy of USTBNA and TBNA; (5) number of aspirates required for successful lymph node aspiration as well as for a diagnosis of cancer for both USTBNA and TBNA; and (6) multiple logistic regression analysis to determine the significance of combinations of clinical predictors and needle aspirate results. Eighty-two bronchoscopic examinations were performed on 80 patients. We found no significant difference between USTBNA and TBNA in sensitivity (82.6% versus 90.5%, respectively), specificity (100% for both), or diagnostic accuracy (86.7% versus 91.7%, respectively). The sensitivity, specificity, and diagnostic accuracy of USTBNA and TBNA were similarly high, regardless of node location (paratracheal or subcarinal). A decrease in the number of aspirates required for lymph node sampling approached statistical significance for all USTBNAs as compared with TBNAs (2.03 +/- 0.19 versus 2.62 +/- 0.25, p = 0.06), but this was not demonstrated for the number required to confirm cancer (1.95 +/- 0.47 versus 2.68 +/- 0.21, p = 0.17). The number of aspirates to successful lymph node aspiration decreased with USTBNA versus TBNA in paratracheal lymph nodes (2.00 +/- 0.20 versus 2.91 +/- 0.34, p = 0.03), but not to a diagnosis of cancer (1.93 +/- 0.25 versus 3.00 +/- 0.58, p = 0.11). No difference was seen in the number of aspirates for subcarinal nodes. The number of TBNA attempts for paratracheal lymph node sampling was inversely correlated with node size (r = 0.48, p = 0.02). No such relation was seen with USTBNA of paratracheal nodes (r = 0.09, p = 0.66), TBNA of subcarinal nodes, or USTBNA of subcarinal nodes. A similar relation was seen between the number of aspirates to a diagnosis of cancer. On multiple logistic regression analysis, a positive transbronchial aspirate was associated only with a larger lymph node and history of prior cancer. We conclude that: (1) in the setting of on-site cytopathology, transbronchial needle aspiration has a high sensitivity, specificity, and diagnostic accuracy in the evaluation of enlarged mediastinal lymph nodes suspected of harboring malignancy; (2) mediastinal anatomy, including vascular structures and lymph nodes, is clearly imaged with endobronchial ultrasonography; (3) a greater short-axis diameter of the mediastinal lymph node and history of a prior malignancy increase the likelihood of a positive transbronchial aspiration; (4) USTBNA exhibits a similarly high diagnostic yield to TBNA in the setting of rapid on-site cytopathology evaluation; (5) USTBNA decreases the number of aspirates required for paratracheal lymph node sampling, which may be particularly useful in sampling smaller paratracheal nodes or at institutions that do not utilize rapid on-site cytopathology evaluation.

Biopsy, Needle↗

Suspected obstructive pyelocaliectasis: Doppler ultrasonography compared with diuretic renal scintigraphy in proven cases.

OBJECTIVE: To compare Doppler ultrasonography with diuretic renal scintigraphy in the differentiation of obstructive from nonobstructive pyelocaliectasis. PATIENTS AND METHOD: The authors reviewed the findings of Doppler ultrasonography and diuretic renal scintigraphy performed over a 3-year period for 27 pyelocaliectatic kidneys (17 obstructed and 10 unobstructed) in 20 individuals ranging in age from 19 to 88 years. The kidneys were classified as "obstructed" or "unobstructed" on the basis of the resistive index as calculated from Doppler ultrasonographic results and as "obstructed", "unobstructed" or "indeterminate" on the basis of the clearance half-time determined from scintigraphic findings. RESULTS: On the basis of scintigraphy, the obstruction status was indeterminate in 12 of the 27 kidneys. The data were analysed for sensitivity and specificity in two ways, first by classifying the kidneys with indeterminate obstruction status as "obstructed, " and then by excluding them from the analysis altogether. In both situations, the differences in sensitivity and specificity between Doppler ultrasonography and scintigraphy were not statistically significant (chi 2 test, p > 0.05). When the kidneys with indeterminate obstruction status were included in the obstructed category, the sensitivity and specificity of Doppler ultrasonography were 94% and 90% respectively and of scintigraphy 100% and 70% respectively; when the kidneys with indeterminate obstruction status were excluded, the sensitivity and specificity of Doppler ultrasonography were 83% and 89% respectively and of scintigraphy 100% and 78% respectively. CONCLUSIONS: These results suggest that Doppler ultrasonography is comparable to diuretic renal scintigraphy in the work-up of potential obstructive pyelocaliectasis. Because grey-scale ultrasonography is usually performed before scintigraphy, a Doppler examination could be added at this stage, which might reduce the time necessary to establish the diagnosis.

Adult↗

Ultrasonic estimation of tissue perfusion: a stochastic approach.

Imaging of blood flow perfusion is an area of significant medical interest. Recently, the advantages of using the total integrated Doppler power spectrum as the parameter that is encoded in color has been shown to result in an approximately threefold increase in flow sensitivity, a relative insensitivity to acquisition angle and lack of aliasing. We have taken this mode a step further and demonstrated the potential for quantifying blood flow using correlation-based algorithms applied to the power signal. We show that phi(tau) = phi(0)e-VT, where phi(tau) is the two-time correlation of the fluctuation in the power signal, and v is the specific flow (reciprocal of mean transit time). Scans of a dog's blood, pumped at a constant rate through gum rubber tubing, were obtained using a Diasonics Spectra 10-MHz linear array transducer at standard range-gated spectral mode (PRF = 1400 Hz, wall filter = 50 Hz, sample gate = 1.5 mm). A fixed Doppler angle of 68 degrees was used. Five different flow rates were tested, and the velocities determined by power decorrelation were compared to the mean velocities calculated from the Doppler shifts by linear regression (R2 = 0.987). We believe the results are very encouraging for using power decorrelation in perfusion evaluation.

Algorithms↗

Acoustic generation of intra-arterial contrast boluses.

Microbubbles generated by ultrasonic cavitation in vivo might be useable as flow indicators in some situations instead of injectable contrast agents. Knowledge of those vascular microbubble-generating ultrasonic fields which produce from negligible up to significant damage will help improve guidelines for more effective, safer diagnostic and therapeutic ultrasound. Microbubble boluses have been generated by a 1.8-MHz, focused sound field in the in vivo canine abdominal aorta. Spatial peak acoustic intensities of 19,000 W cm-2 generated microbubble boluses when exposure was longer than 12 ms, whereas intensities greater than 4300 W cm-2 generated a bolus when exposure was for 250 ms. The onset time of these boluses (less than one cardiac cycle) is unachievable with intravenous contrast injection. With optimized waveforms and focusing, acoustic bolus generation may prove to be an effective, minimally invasive method for fast performance of certain selective angiography.

Acoustics↗

Registration of three-dimensional compound ultrasound scans of the breast for refraction and motion correction.

Use of multiple look directions, that is, compound imaging, has been shown previously to increase detection of specular reflectors and averaging of speckle noise in gray-scale images, often at the expense of spatial resolution and other misregistration errors. In color flow imaging, additional view angles can fill in vessels missed due to Doppler angle dropout and increase quantitative and visual Doppler accuracy by triangulation or a simple peak-frequency-shift combination algorithm. Image registration and unwarping throughout multiple three-dimensional (3D) volume sets should correct for many refraction artifacts, motion between and during compounded image sets and even, possibly, positioning errors between image sets, acquired months apart, to display growth of abnormalities. The registration described here does not provide sufficient accuracy for formation of enhanced coherent apertures, but shows promise in some cases to provide superior compound images and possibly comparisons of current and prior studies. In this study, the breast is stabilized by mild compression between a flat plate and a scanning membrane. Registration and unwarping is performed retrospectively on two separate volumetric data sets by defining pairs of corresponding points and, in some cases, line and plane segments. Three-dimensional linear affine transforms are performed using identified points, lines and planes. 3D nonlinear warped transforms are also possible given adequate numbers of identifiable points. More than two data sets are registered by selecting one as the standard, and registering the remainder to match. The most appropriate algorithm, such as averaging or maximum amplitude, may be used to combine the data sets for display. Significant success has been achieved in compound display of a test object and of the breast in vivo, even when there was relative motion or warping between image sets. In pulse-echo imaging, homologous feature registration for compounding appears to have advantages over mechanically registered compounding methods previously employed in the breast and significant increases in lesion and structural conspicuity are noted due to a reduction in speckle noise. The improvements from compounding in 3D, surface-rendered Doppler imaging of vasculature are striking.

Adenocarcinoma↗

Nonpulsatile arterial waveforms: observations during graded testicular torsion in rats.

RATIONALE AND OBJECTIVES: We tested whether testicular torsion could completely damp distal arterial pulsatility, resulting in venous-appearing arterial waveforms. METHODS: Progressively increasing testicular torsion was unilaterally produced in five rats. Doppler waveforms of the testicular artery distal to the torsion were obtained as soon as possible after each level of torsion until a complete absence of pulsatility was noted. RESULTS: One animal was not studied further after the first 180 degrees of torsion occluded flow. In three of the remaining four animals, the testicular artery resistive index (RI) at baseline (0.51, 0.58, 0.64) was within the range of the normal human intratesticular RI and decreased with increasing torsion, culminating in nonpulsatile, venous-appearing waveforms at high degrees of torsion. CONCLUSIONS: Testicular torsion can completely damp arterial pulsatility, resulting in nonpulsatile, venous-appearing arterial Doppler waveforms.

Animals↗