Search PubMed⌕ Search

Biomedical subjects

J M Links

Publications and source records attributed to J M Links.

At least 37 records · Page 2Linked to original sources

Biomarkers and mechanistic approaches in environmental epidemiology.

Environmental epidemiological research involves the identification of relationships between previous exposures to putative causative agents and subsequent biological effects with study populations. Such relationships are often hard to fully characterize because of difficulties in accurately quantifying exposure, dose, and effect. Biomarkers are indicators, residing in biological systems or samples, of exposure, dose, effect, or susceptibility. Biomarkers of exposure indicate the presence of previous exposure to an environmental agent; a biomarker of dose bears a quantitative relationship to previous exposure or dose; these include exogenous substances, interactive products, or interactions that change the status of the target molecule. Biomarkers of effect indicate the presence and magnitude of a biological response to exposure to an environmental agent; these include endogenous components, or measures of the functional capacity or state of the system. Biomarkers of susceptibility indicate an elevated sensitivity to the effects of an environmental agent; these include the presence or absence of an endogenous component, or abnormal functional responses to an administered challenge. The development of molecular biomarkers for environmental agents is based upon specific knowledge of metabolism, interactive product formation, and general mechanisms of action. The validation of any biomarker-effect link requires parallel experimental animal and human epidemiological studies.

Biomarkers↗

Planar and high-resolution SPECT bone imaging in the diagnosis of facet syndrome.

UNLABELLED: This study's goals were to determine the appearance of potentially symptomatic facet joints on planar and high-resolution SPECT radionuclide bone imaging, relate the relative sensitivity of the two techniques and assess the predictive value in a clinical setting. METHODS: Fifty-eight consecutive patients referred with a diagnosis of possible facet syndrome were imaged during the same visit using both a well-established planar and a SPECT technique developed to emphasize high spatial resolution. The standard of reference included facet injections with a marcaine and steroid mixture, with review of a pain journal completed by the patient included in the followup criteria. RESULTS: In the 43 patients comprising the final study group, 7 were diagnosed with facet syndrome, 5 with abnormal planar images and 7 with abnormal SPECT images. A total of 10 facet joints with abnormal increased uptake were seen on SPECT which were not demonstrated on planar imaging. There was high sensitivity (100% SPECT, 71% planar), but somewhat lower specificity (71% SPECT, 76% planar). The negative predictive value was high (100% SPECT, 93% planar). Radionuclide bone imaging additionally discovered a nonfacet joint etiology for patient symptoms in 16 of the 43 patients. CONCLUSION: Higher spatial resolution SPECT images are better accepted by referring physicians who correlate them with CT or MR images. The high negative predictive value allows radionuclide bone imaging to be used to select appropriate patients to undergo the invasive facet injection procedure.

Adolescent↗

EPR dosimetry of cortical bone and tooth enamel irradiated with X and gamma rays: study of energy dependence.

Previous investigators have reported that the radiation-induced EPR signal intensity in compact or cortical bone increases up to a factor of two with decreasing photon energy for a given absorbed dose. If the EPR signal intensity was dependent on energy, it could limit the application of EPR spectrometry and the additive reirradiation method to obtain dose estimates. We have recently shown that errors in the assumptions governing conversion of measured exposure to absorbed dose can lead to similar "apparent" energy-dependence results. We hypothesized that these previous results were due to errors in the estimated dose in bone, rather than the effects of energy dependence per se. To test this hypothesis we studied human adult cortical bone from male and female donors ranging in age from 23 to 95 years, and bovine tooth enamel, using 34 and 138 keV average energy X-ray beams and 137Cs (662 keV) and 60Co (1250 keV) gamma rays. In a femur from a 47-year-old male (subject 1), there was a difference of borderline significance at the alpha = 0.05 level in the mean radiation-induced hydroxyapatite signal intensities as a function of photon energy. No other statistically significant differences in EPR signal intensity as a function of photon energy were observed in this subject, or in the tibia from a 23-year-old male (subject 2) and the femur from a 75-year-old female (subject 3). However, there was a trend toward a decrease (12-15%) in signal intensity at the lowest energy compared with the highest energy in subjects 1 and 3. Further analysis of the data from subject 1 revealed that this trend, which is in the opposite direction of previous reports but is consistent with theory, is statistically significant. There were no effects of energy dependence in the tooth samples.

Adult↗

Noncompartmental and compartmental modeling of the kinetics of carbon-11 labeled pyrilamine in the human brain.

The kinetic pattern of a 11C-labeled histamine H1 receptor antagonist, [11C]pyrilamine, was investigated in the human brain by factor analysis of dynamic PET studies. Tissue time activity curves were also processed by compartment model curve fitting preceded by deconvolution analysis. Factor analysis revealed two statistically significant and physiologically meaningful kinetic patterns: one for specific and another for nonspecific binding of the radioligand. From these two factors a compartment model containing two tissue compartments (one for specific binding and another for nonspecific binding and free ligand) was constructed. The two-compartment model was also supported by the impulse response function, which was obtained by deconvolution and showed two components. The factor image constructed from factor two demonstrated a distribution pattern characteristic for brain regions rich (frontal, parietal, and temporal lobes) or poor (occipital lobe and cerebellum) in H1 receptors. Blockade of H1 receptors with unlabeled pyrilamine, diphenhydramine, or hydroxyzine caused a significant reduction of this factor. Blockade produced no significant changes in factor one representing nonspecific binding. We conclude that the kinetics of [11C]pyrilamine in the brain can be described by two tissue compartments, one related to the distribution of the H1 receptors. Factor analysis of dynamic studies can be used to locally separate these two compartments, for identification of regions rich and poor in H1 receptors and for noninvasive quantitative investigation of the effects of H1 receptor blockers such as pyrilamine, diphenhydramine, or hydroxyzine.

Adult↗

Multidetector single-photon emission tomography: are two (or three or four) heads really better than one?

Today, almost every camera sold, with the exception of mobile systems, is "single-photon emission tomography-capable". The atest technical development is the so-called multidetector systems. This article reviews the development and current and potential clinical role of these multidetector systems, with particular emphasis on multicamera systems. The utility of multidetector systems is considered in the context of an image's signal-to-noise ratio, including its effect on diagnostic or quantitative accuracy. The potential for multidetector systems to increase the signal-to-noise ratio is discussed, as are other potential benefits. Finally, advice on an approach to equipment selection is provided.

Brain↗

Exposure-to-absorbed-dose conversion for human adult cortical bone.

The conversion of measured exposure to absorbed dose at a point in bone, under conditions of electron equilibrium, involves a factor (the f-factor) which is proportional to the ratio of the spectrum-averaged photon energy-absorption coefficient for bone to that for air. This paper gives mass energy-absorption coefficients and f-factors for three compositions of human adult compact or cortical bone recommended in publications by the ICRU and the ICRP, for photon energies from 1 keV to 1.5 MeV. Spectrum-averaged f-factors for a number of calibration x-ray beams ranging from 10 to 250 kVp have been calculated and compared to corresponding results obtained with the use of an equivalent photon energy derived from the measured thickness of the half-value layer. At low photon energies (approximately less than 200 keV), the new f-factor results reflect: (a) the rather large differences due to the differing calcium contents among the recommended compositions for bone: and (b) the generally poor predictions obtained when replacing a broad energy spectrum by an equivalent photon energy.

Adult↗

Acute exposure to acid fog. Effects on mucociliary clearance.

Submicrometric sulfuric acid (H2SO4) aerosol can affect mucociliary clearance without eliciting irritative symptoms or changes in pulmonary function. The effect of larger fog droplets containing H2SO4 on mucociliary clearance is unknown. We quantified mucociliary clearance from the trachea (n = 4) and small airways (n = 7) of young healthy male adults after an acute exposure to H2SO4 fog (MMAD = 10.3 microns; pH = 2.0; liquid water content = 481 +/- 65 mg/m3; osmolarity = 30 mOsm). Acid fog (AF) or saline fog (SF) (10.9 microns; 492 +/- 116 mg/m3; 30 mOsm) was administered for 40 min of unencumbered breathing (no mouth-piece) at rest and for 20 min of exercise sufficient to produce oronasal breathing. Fog exposures were followed by a methacholine (MCh) challenge (a measure of airway reactivity) or inhalation of technetium-99M radioaerosol (MMAD = 3.4 microns) on 2 study days each. Changes in symptoms and forced ventilatory function were also assessed. Clearance was quantified from computer-assisted analyses of gamma camera images of the lower respiratory tract in terms of %removal/min of the radiolabel from the trachea 25 min after inhalation and from the outer zone of the right lung after 1.9 to 3 h. Symptoms, forced ventilatory function, and MCh response were unaffected by either fog. Tracheal clearance was more rapid in four of four subjects after AF (0.83 +/- 1.58% removal/min) compared with that after SF (-0.54 +/- 0.85% removal/min). Outer zone clearance was more rapid in six of seven subjects after AF (0.22 +/- 0.15% removal/min) compared with that after SF (0.01 +/- 0.09% removal/min).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Detection of left anterior descending coronary artery disease in patients with left bundle branch block.

The detection of coronary artery disease is difficult if a patient has electrocardiographic evidence of left bundle branch block (BBB). Septal blood flow may be reduced in patients with left BBB, despite no angiographic evidence of left anterior descending (LAD) coronary artery disease. We have developed a new method of quantification of Thallium-201 single-photon emission computed tomographic (SPECT) images with the aim of better separating patients with left BBB and LAD disease from those with left BBB alone. The study cohort comprised 8 normal subjects (group I) and 20 patients with left BBB and chest pain who underwent thallium-201 SPECT imaging and coronary angiography. Eight patients (group II) had < or = 50% LAD stenosis, and 12 (group III) had > or = 70% LAD stenosis. Septal abnormality scores on the second short-axis slice from the base were computed, based on comparison of each subject's short-axis circumferential profile with a normal reference curve. This followed a procedure in which each profile was scaled to minimize differences in its absolute level in relation to the reference curve. Septal abnormality scores on stress images were 0.8 +/- 22 for group I, 27 +/- 43 for group II, and 165 +/- 67 for group III (p = 0.15 for group I vs II, and p < 0.0001 between groups I and III, and II and III).(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Rest thallium-201 myocardial perfusion imaging in a patient with leukaemic infiltration of the heart.

Despite the high incidence of leukaemic infiltration of the heart, only 8 cases of atrioventricular block due to leukaemia have been reported in the literature. Improvement in the heart block associated with disappearance of the leukaemic infiltrate has not been reported. A rest thallium-201 study was used in a 65-year-old man to demonstrate leukaemic infiltration of the heart which was associated with complete heart block. After chemotherapy, when the tumour burden was reduced and the leukaemia in remission, his heart block resolved, and a follow-up thallium scan was normal.

Aged↗

Improved positron emission tomography quantification by Fourier-based restoration filtering.

Positron emission tomography (PET) images are characterized by both poor spatial resolution and high statistical noise. Conventional methods to reduce noise, such as local weighted averaging, produce further deteriorations in spatial resolution, while the use of deconvolution to recover resolution typically amplifies noise to unacceptable levels. We studied the use of two-dimensional Fourier filtering to simultaneously increase quantitative recovery and reduce noise. The filter was based on inversion of the scanner's measured transfer function, coupled with high frequency roll-off. In phantom studies, we found improvements in both "hot" and "cold" sphere quantification. Compared with ramp-only filtering, improvements in hot spot recovery for the highest accuracy filter averaged 13.6% +/- 6.6% for spheres larger than 15 mm; improvements in cold spot recovery averaged 30.7% +/- 4.7%. At the same time, the noise was reduced by a factor of 3 compared with randomly filtering. Fourier-based image restoration filtering is thus capable of improving both accuracy and precision in PET.

Brain↗

Factor analysis of regional cerebral glucose metabolic rates in healthy men.

Cerebral glucose utilization measured with fluorine-18-fluoro-2-deoxy-D-glucose is characterized by considerable variability both among different persons and for the same person examined on different occasions. The goal of this study was to explore whether some regions of the brain were more variable than others with respect to glucose utilization and whether there was a pattern in their covariance. The global and regional cerebral utilization of glucose was measured in 12 healthy young volunteers on 3 or 4 occasions. In all, 24 regions were examined. The interrelation of the glucose utilization rates of the brain regions was investigated by factor analysis of the metabolic rates. Some 70% of the total variance was attributable to only 1 factor, while 80% of the total variance could be attributed to 2 factors. Regions making up the first factor were the frontal and temporal cortex, cingulate gyrus, caudate nucleus, thalamus and putamen. These regions are functionally related to the limbic system. Regions of the second factor were the parietal cortex, occipital cortex and cerebellum, regions more clearly related to sensory and motor functions. The 2-factor pattern was highly reproducible, being found with different algorithms for factor extraction and rotation. Under resting conditions, the variance of cerebral metabolism seems to be primarily related to regions which are closely involved with the limbic system. Cortical regions involved primarily in motor and sensory functions have less influence on the variance.

Adult↗

The influence of biological and technical factors on the variability of global and regional brain metabolism of 2-[18F]fluoro-2-deoxy-D-glucose.

This study investigated the influence of biological and technical factors on variations of global and regional cerebral metabolic rate of glucose (CMRglc) measured with 2-[18F]fluoro-2-deoxy-D-glucose ([18F]FDG). Twelve male volunteers (22-40 years) were investigated on three or four occasions for a total of 42 studies. We calculated the variance/covariance of the following parameters: CMRglc, six parameters of the blood clearance of [18F]FDG, hour of injection, peak time of blood radioactivity, and six components of the operational equation (nonradioactive blood glucose concentration, brain radioactivity, two integrals, numerator, and denominator). There was correlation among these six components, except for nonradioactive blood glucose. However, the correlation between the CMRglc and the individual components of the operational equation was poor. The inter- and intrapersonal CMRglc coefficients of variations were 13.8 and 7.1%, respectively. In contrast, coefficients of variations of the numerator and denominator of the operational equation were 34.6 and 32.6%, respectively, and were always in the same direction. No correlation was found between CMRglc and the technical factors in the numerator and denominator of the operational equation. Factor analysis disclosed that a single factor was responsible for 70% of the variance. This factor included caudate, putamen, thalamus, frontal cortex, temporal cortex, and cingulate gyrus. These structures are involved with multiple complex functions, from autonomic motor control to behavior and emotions. The intrinsic metabolic variability of these structures, along with the basal metabolic processes that are continuously going on in the brain, may be the best explanation for the variance encountered in our investigation.

Adult↗

Measurement of radiotracer concentration in brain gray matter using positron emission tomography: MRI-based correction for partial volume effects.

Accuracy in in vivo quantitation of brain function with positron emission tomography (PET) has often been limited by partial volume effects. This limitation becomes prominent in studies of aging and degenerative brain diseases where partial volume effects vary with different degrees of atrophy. The present study describes how the actual gray matter (GM) tracer concentration can be estimated using an algorithm that relates the regional fraction of GM to partial volume effects. The regional fraction of GM was determined by magnetic resonance imaging (MRI). The procedure is designated as GM PET. In computer simulations and phantom studies, the GM PET algorithm permitted a 100% recovery of the actual tracer concentration in neocortical GM and hippocampus, irrespective of the GM volume. GM PET was applied in a test case of temporal lobe epilepsy revealing an increase in radiotracer activity in GM that was undetected in the PET image before correction for partial volume effects. In computer simulations, errors in the segmentation of GM and errors in registration of PET and MRI images resulted in less than 15% inaccuracy in the GM PET image. In conclusion, GM PET permits accurate determination of the actual radiotracer concentration in human brain GM in vivo. The method differentiates whether a change in the apparent radiotracer concentration reflects solely an alteration in GM volume or rather a change in radiotracer concentration per unit volume of GM.

Algorithms↗

Reduced left ventricular cavitary activity ("black hole sign") in thallium-201 SPECT perfusion images of anteroapical transmural myocardial infarction.

Apparently reduced left ventricular (LV) cavitary thallium activity in both planar and tomographic perfusion images has been previously observed by these and other investigators. With single-photon emission computerized tomography, we have clinically noted that this "black hole sign" was associated with an aneurysm in the setting of a transmural anterior or anteroapical perfusion defect. We have now prospectively studied the etiology and predictive value of this sign in 84 consecutive patients with an anterior, anteroapical transmural perfusion defect. Of the 84 patients, 49 had both LV aneurysm (confirmed by contrast ventriculography, echocardiography or gated blood pool studies) and a black hole sign. Only 1 patient with an aneurysm did not have the black hole sign, and 2 without aneurysm did. Thus, it is concluded that this sign is highly accurate in diagnosing LV aneurysm. Because thallium-201 single-photon emission computerized tomography imaging is often performed as one of the first diagnostic tests soon after myocardial infarction, this has important clinical management implications.

Adult↗