Intraoperative ultrasound and preoperative localization detects all occult insulinomas; discussion 1025-6.

HYPOTHESIS: Preoperative invasive localization procedures with intraoperative ultrasound (IOUS) can result in successful surgical treatment of occult insulinomas when noninvasive imaging study results are equivocal or negative. DESIGN: Prospective study. SETTING: Tertiary care university hospital. PATIENTS: Thirty-seven consecutive patients with a biochemical diagnosis of insulinoma without multiple endocrine neoplasia (MEN). INTERVENTION: All patients underwent portal venous sampling (PVS) (n = 22) or calcium angiogram (n = 15) followed by surgery with palpation and IOUS (n = 37). MAIN OUTCOME MEASURE: Portal venous sampling, calcium angiogram, palpation, and IOUS were compared for accurate localization of insulinoma. RESULTS: All patients were cured of hypoglycemia after surgery. Portal venous sampling correctly localized tumors in 17 (77%) of 22 patients. Calcium angiogram was correct in 13 (87%) of 15 patients. Palpation identified 24 (65%) of 37 tumors, and IOUS found 35 (95%) of 37 tumors. The 2 tumors missed by IOUS were located in the tail of the pancreas and were resected based on regional localization alone. CONCLUSIONS: Intraoperative ultrasound is the single best localization study, but it will miss some tumors that regional localization can identify. Combining both modalities allowed surgical cure of all insulinomas in our study. Therefore, we recommend both IOUS and regional localization for insulinoma when preoperative imaging studies are equivocal.

Adult↗

Analysis of initial CT findings after endovascular repair of abdominal aortic aneurysm.

PURPOSE: To determine the spectrum and frequency of specific computed tomographic (CT) findings in the acute period after endovascular repair of abdominal aortic aneurysm (AAA). MATERIALS AND METHODS: CT images obtained 1--3 days after endograft placement were evaluated in 88 patients. The images were analyzed for stent position, appearance of endograft components, perigraft leak, and postoperative findings including air and acute thrombus within the aneurysm and air surrounding the femoral-femoral bypass graft. Findings that could be misinterpreted as perigraft leak were evaluated. RESULTS: Fifteen (17%) of 88 patients had perigraft leak in the acute postoperative period. The bare segment of the proximal self-expanding stent covered one or both renal arteries in 54 (61%) patients. One patient had CT evidence of renovascular compromise. Postoperative air was within the aneurysmal sac in 51 (58%) patients and surrounded the femoral-femoral bypass graft in 67 (94%) of 71 patients in whom the grafts were evaluated with CT. Mottled attenuation within the aneurysmal sac was seen in 50 (57%) patients. Forty-six (52%) patients had calcifications within longstanding thrombus. In 31 (35%) patients, findings that could have been misinterpreted as perigraft leak were identified. CONCLUSION: Accurate analysis of CT findings after endovascular AAA repair requires careful review of all available CT images (preprocedural and pre- and postcontrast) and clear understanding of specific stent-graft components and placement.

Aged↗

Endovascular aneurysm repair in high-risk patients.

PURPOSE: The purpose of this study was to evaluate the role of endovascular aneurysm repair in high-risk patients. METHODS: The elective endovascular repair of infrarenal aortic aneurysm was performed in 116 high-risk patients with either custom-made or commercial stent grafts. The routine follow-up examination included contrast-enhanced computed tomography (CT) before discharge, at 3, 6, and 12 months, and annually thereafter. Patients with endoleak on the initial CT underwent re-evaluation at 2 weeks. Those patients with positive CT results at 2 weeks underwent endovascular treatment. RESULTS: Endovascular repair was considered feasible in 67% of the patients. The mean age was 75 years, and the mean aneurysm diameter was 6.3 cm. The American Society of Anesthesiologists grade was II in 3.4%, III in 65.5%, IV in 30.1%, and V in 0.9%. There were no conversions to open repair. Custom-made aortomonoiliac stent grafts were implanted in 77.6% of the cases, custom-made aortoaotic stent grafts in 11.2%, and commercial bifurcated stent grafts in 11.2%. The 30-day rates of mortality, major morbidity, and minor morbidity were 3.4%, 20.7%, and 12%, respectively, in the first 58 patients and 0%, 3.4%, and 3.4%, respectively, in the last 58. The late complications included five cases of stent graft kinking, two cases of femorofemoral graft occlusion, and three cases of proximal stent migration, one of which led to aneurysm rupture. At 2 weeks after repair, endoleak was present in 10.3% of the cases. All the type I (direct perigraft) endoleaks underwent successful endovascular treatment, whereas only one type II (collateral) endoleak responded to treatment. The technical success rate at 2 weeks was 86.2%, and the clinical success rate was 96.6%. The continuing success rate was 87.9%. Seventeen patients died late, unrelated deaths. CONCLUSION: Endovascular aneurysm repair is safe and effective in patients at high risk, for whom it may be the preferred method of treatment.

Aged↗

Arteriographic detection of renovascular disease in potential renal donors: incidence and effect on donor surgery.

PURPOSE: To determine the arteriographic incidence and severity of renal arterial disease in potential renal donors and to evaluate the effect of identifying vascular abnormalities on subsequent donor surgery. MATERIALS AND METHODS: The records of 716 potential living renal donors who underwent conventional arteriography were reviewed. Abnormal arteriograms were reexamined to characterize vascular disease, and the effect of identifying renovascular disease on subsequent donor surgery was ascertained with chart review. RESULTS: Renovascular abnormalities were noted in the dictated reports in 78 patients (10.9%). The most common causes were fibromuscular dysplasia and atherosclerosis. The arteriograms of 64 patients were available for retrospective review. Abnormalities were characterized as minimal stenosis (<30% narrowing) in 42 patients and mild stenosis (30%-50% narrowing) in 19 of 61 patients with arteriographic abnormalities at retrospective review. In three patients, no significant abnormality was seen at retrospective review. The effect of detecting renovascular disease on donor selection was determined in 74 of the 78 patients. In 73 of these 74 patients (99%), detection of an abnormality directly affected donor surgery. CONCLUSION: In this population of potential renal donors, the arteriographic incidence of renovascular disease (10.9%) was higher than previously reported. Although renovascular abnormalities were mild, their detection influenced the plan for donor surgery in almost all patients.

Adolescent↗

Tesio catheter: radiologically guided placement, mechanical performance, and adequacy of delivered dialysis.

PURPOSE: Tunneled catheters are an alternative means of vascular access for patients in need of hemodialysis who cannot undergo dialysis through a surgical shunt. This study was undertaken to evaluate the performance of the Tesio dialysis catheter. MATERIALS AND METHODS: A prospective study of the Tesio catheter was performed. Follow-up data regarding catheter function and adequacy of dialysis were obtained from nine hemodialysis facilities. RESULTS: Seventy-nine Tesio catheters were placed in 71 patients. Immediate technical success was 99% (78 of 79 catheters). The procedure complication rate was 9% (seven catheters). Only two complications required intervention: one fatal air embolism and one chest wall hematoma. Sixty-seven catheters in 60 patients were followed up for a total of 4,367 catheter days. Overall, catheter-related infection occurred in 9% (six of 67 catheters). Primary catheter patency was 87% at 1 week, 82% at 1 month, 72% at 3 months, and 66% at 6 months. Mean blood flow was 286 mL/min immediately after insertion, 301 mL/min at 3 months, and 306 mL/min at 6 months. Adequate dialysis dose as reflected by a urea reduction ratio of 60 or more or a urea kinetic modeling, or Kt/V, value of 1.2 or more was observed on at least one occasion for 74% and 76% of catheters, respectively. CONCLUSION: The Tesio catheter is a reasonable means of vascular access for patients who undergo dialysis but are not candidates for surgical shunt placement.

Adolescent↗

Endovascular repair of a presumed aortoenteric fistula: late failure due to recurrent infection.

PURPOSE: To describe a case of presumed aortoduodenal fistula that was treated by endovascular implantation of a stent-graft. METHODS AND RESULTS: A 76-year-old man was transferred from another hospital where he had been treated for upper gastrointestinal hemorrhage over a 2-month period. Ten years previously, he had undergone aortobifemoral bypass, the right limb of which recently thrombosed. At the time of transfer, computed tomographic scanning showed a large false aneurysm between the aorta and the duodenum. Endoscopy disclosed mucosal erosions in the fourth portion of the duodenum. Following implantation of 2 overlapping stent-grafts, the bleeding ceased and the false aneurysm disappeared. At no time did the patient have a fever. The patient initially did well, but 8 months after treatment, he presented with fever and chills. Recurrent infection had caused erosion of the aorta so that a large portion of the stent-graft was visible from the duodenum. The infected graft and stent-grafts were removed in a two-part operation, from which the patient recovered satisfactorily. CONCLUSIONS: Endovascular stent-grafts may have a role to play in the management of aortoduodenal fistula, if only as a temporary measure to control bleeding.

Aged↗

Percutaneous management of abscess and fistula following pancreaticoduodenectomy.

PURPOSE: To evaluate the efficacy of percutaneous drainage of fluid collections following pancreaticoduodenectomy (Whipple's procedure). METHODS: We performed a retrospective review of 19 patients referred to our service with fluid collections following pancreaticoduodenectomy. The presence of associated enteric or biliary fistulas, the route(s) of access for image-guided drainage, the incidence of positive bacterial cultures, and the duration and success of percutaneous management were recorded. RESULTS: Fistulous communication to the jejunum in the region of the pancreatico-jejunal anastomosis was demonstrable in all 19 patients by gentle contrast injection into drainage tubes. Three patients had concurrent biliary fistulas. In 18 of 19 patients, fluid samples yielded positive bacterial cultures. Successful percutaneous evacuation of fluid was achieved in 17 of 19 patients (89%). The mean duration of drainage was 31 days. CONCLUSION: Percutaneous drainage of abscess following pancreaticoduodenectomy is effective in virtually all patients despite the coexistence of enteric and biliary fistulas.

Abdominal Abscess↗

Transcatheter embolization for the treatment of misperfusion after hepatic artery chemoinfusion pump implantation.

BACKGROUND: The use of surgically implanted chemoinfusion pumps for the treatment of hepatic metastases from colorectal carcinoma can be complicated by intra- or extrahepatic misperfusion. This may result in suboptimal tumor exposure to the chemotherapeutic agent and injury to other gastrointestinal organs. Misperfusion can be managed by selective arterial transcatheter embolization. METHODS: Between 1989 and 1996, 16 patients with liver metastases from colorectal carcinoma and with hepatic artery chemoinfusion pump misperfusion were treated using transcatheter coil embolization. Six female and 10 male patients (age range, 34-84 years; median, 51.5 years) were identified by retrospective review of the records of the Department of Interventional Radiology. After pump placement, abnormal liver perfusion scan or methylene blue endoscopy study results prompted angiography with coil embolization. After embolization, the imaging studies were repeated and patients were monitored in the Oncology Clinic. RESULTS: Eight patients exhibited intrahepatic misperfusion (group 1) and eight extrahepatic misperfusion (group 2). Coil embolization was immediately successful in 100% of patients in group 1, with restoration of normal hepatic perfusion, and in 75% in group 2. There were no immediate procedure-related complications. Follow-up periods ranged from 1 to 23 months (median, 13.5 months). Embolization was unsuccessful for two patients (in group 2), who tolerated a modified chemotherapeutic regimen, with follow-up periods of 18.5 and 22 months. CONCLUSIONS: Transcatheter coil embolization is the therapy of choice for the management of hepatic artery chemoinfusion pump misperfusion. It is rapid, effective, and well tolerated by patients and obviates the need for additional surgical intervention.

Adult↗