Publications and source records attributed to J M Kratz.

At least 19 recordsLinked to original sources

Fate of gelatin-resorcinol-formaldehyde/glutaraldeyde adhesive on femoral vessel morphology.

Several clinical reports have demonstrated that gelatin-resorcinol-formaldehyde/glutaraldehyde (GRFG) glue can be useful in the repair of acute aortic dissection; however, the cellular and extracellular events that follow GRFG application, as well as the mechanisms responsible for the long-term strength and adhesive properties of GRFG, remain unclear. Accordingly, the present study examined the long-term effects of GRFG adhesive application on femoral vessel extracellular structure and composition. The left and right femoral artery and vein were sterilely exposed in adult rats, and GRFG (2 mL) was applied between and around one pair of vessels. An equivalent amount of sterile saline was applied to the contralateral vessels to serve as an intrinsic control. At either 1 (n = 6) or 2 (n = 6) months postoperatively, the lower extremities were perfusion fixed and harvested to preserve the native anatomy and cytoarchitecture of the femoral region. Gross examination of the specimens revealed no evidence of necrosis or wound breakdown. Tissue blocks (4 microm) were then sectioned perpendicular to the treated vessel region and subjected to histomorphometric analysis using computer-assisted microscopy. The perivascular capsule area, relative content of fibrillar collagen, and number of nucleated cells within the interstitial space were computed. At 1 and 2 months following the application of GRFG adhesive, perivascular capsular size increased by 42 and 221%, respectively. Perivascular interstitial collagen content increased by 21% at 1 month and by 50% at 2 months. The nucleated cell number increased by 107% at 1 month and by 166% at 2 months. This cellular infiltrate appeared to be of fibroblastic morphology. Thus, a potential contributory mechanism to the long-term strength and adhesive capacities of GRFG adhesive may be extracellular remodeling and not the intrinsic properties of GRFG glue itself.

Animals

Intravenous sedation for placement of automatic implantable cardioverter-defibrillators.

OBJECTIVE: To evaluate a change in anesthetic technique for transvenous placement of the automatic implantable cardioverter-defibrillator (ICD). DESIGN: Retrospective study. SETTING: A university hospital. PARTICIPANTS: Twenty-eight patients who underwent placement of ICDs. INTERVENTIONS: Thirteen patients had the ICD placed via the transvenous approach with general anesthesia (group GA). Fifteen patients had the ICD placed via the transvenous approach with intravenous sedation (group IV). MEASUREMENTS AND MAIN RESULTS: Intraoperative systolic and diastolic blood pressures were significantly higher in group IV compared with group GA. The ICD was successfully placed in all patients in both groups. There were no intraoperative complications noted in either group during induction of fibrillation and defibrillation, and there was no recall by any patient in either group. The average hospital stay was significantly less in group IV (1.8 days) compared with group GA (3.4 days). CONCLUSIONS: Intravenous sedation for the placement of ICDs is a safe and effective technique. Patients who had their ICD placed while receiving intravenous sedation experienced higher intraoperative blood pressures and were discharged from the hospital earlier than those patients who received general anesthesia.

Aged

Pseudo fracture of a defibrillating lead.

Routine follow-up chest X ray of several patients with the Endotak transvenous pacing lead suggested fracture of the conductor at the distal end of the proximal defibrillating coil. Electrical evaluation of these patients' leads demonstrated them to be working normally. Multiple x-ray views of a new undamaged lead demonstrated that in some projection the Endotak lead may appear fractured in spite of normal continuity of the conductors. Physicians dealing with these patients should be aware of this confusing x-ray finding.

Artifacts

The risk of small St. Jude aortic valve prostheses.

We reviewed our 12-year experience with 254 adult patients who had St. Jude valves in the aortic position and used multivariate analysis to examine risk factors possibly affecting long-term morbidity and mortality. Nineteen-millimeter or 21-mm valves were implanted in 115 patients. Poor preoperative congestive heart failure status was associated with persistent congestive heart failure on late follow-up. Preoperative congestive heart failure and coronary artery disease were the only predictors of overall late death. Late deaths associated with heart failure and late sudden deaths were examined separately. Preoperative degree of heart failure was the only predictor of late death with associated heart failure. The implantation of a 19- or 21-mm valve in patients with a body surface area greater than 1.9 m2 somewhat increased the risk of late sudden death. In patients with a body surface area greater than 1.9 m2 and with a 19-mm or 21-mm annulus, consideration should be given to using a high-performance St. Jude valve or performing an annulus-enlarging procedure if this can be done with negligible morbidity.

Adult

The relation between latissimus dorsi skeletal muscle structure and contractile function after cardiomyoplasty.

Past reports suggest that structural changes within the latissimus dorsi muscle occur with chronic electrical stimulation during cardiomyoplasty. However, the specific changes in the structure of the latissimus dorsi muscle and the relation to muscle contractile function with cardiomyoplasty are unknown. Accordingly, this study examined regional changes in latissimus dorsi muscle structure and function after cardiomyoplasty. The left latissimus dorsi muscle was mobilized and wrapped around the heart in pigs with the use of standardized techniques and the latissimus dorsi muscle chronically paced at ambient heart rates (90 beats/min; 20 Hz, 5 V amplitude, n = 6). After 6 weeks, the paced latissimus dorsi muscle and the contralateral control muscle were removed and divided into proximal (0 to 3 cm), middle (3 to 6 cm), and distal (6 to 12 cm) regions. By computer-assisted morphometry, muscle cell myofibril volume, cross-sectional area, and collagen percent area were determined. In the paced latissimus dorsi muscle, myofibril volumes increased by more than 50% in the proximal and middle regions compared with those in the contralateral control muscle. However, myofibril volumes were significantly lower in the distal region of the paced latissimus dorsi muscle compared with those in control muscles (33% +/- 5% versus 20% +/- 3%, p < 0.05). In the paced latissimus dorsi muscle, cross-sectional area was significantly reduced from that of control muscles in all regions. A further reduction in cross-sectional area was noted in the distal region of the paced latissimus dorsi muscle compared with that in both the contralateral control muscle and the proximal and middle regions of the paced latissimus dorsi muscle. Collagen content significantly increased in the paced latissimus dorsi muscle compared with that in control muscle with a more fibrotic pattern observed in the distal region. Latissimus dorsi muscle strips (less than 2 mm2 cross-sectional area) were harvested, and peak and velocity of tension development were examined after field electrical stimulation at 0.2 to 1.2 Hz. At 0.2 Hz, the velocity of tension development was unchanged in the paced latissimus dorsi muscle compared with that in control muscle. However, peak tension development degraded by only 28% in the paced latissimus dorsi muscles but fell by 51% in control muscles with increased stimulation frequencies. In summary, the contractile function of the chronically stimulated latissimus dorsi muscle was associated with fatigue resistance and increased contractile protein content. However, more distal regions of the paced latissimus dorsi muscle demonstrated atrophy and fibrosis.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals

Driving safety among patients with automatic implantable cardioverter defibrillators.

OBJECTIVE: To determine the driving behavior of patients following the placement of automatic implantable cardioverter defibrillators (AICDs). SUBJECTS AND DESIGN: Forty patients with AICDs (33 men, seven women; mean age, 62.7 years) responded to a questionnaire designed to ascertain driving behavior after hospital discharge. RESULTS: Despite medical advice never to drive again, 28 patients (70%) resumed driving, with the majority doing so by 8 months after AICD implantation. Of these, 11 (40%) identified themselves as the primary driver in their household. Fourteen (50%) drove daily. Two (7%) were driving and continued to drive during discharge of their AICDs. Twenty-five (91%) reported that they felt comfortable and safe while driving. CONCLUSION: A majority of patients with AICDs continue to drive after a proscription of this activity by health care workers.

Automobile Driving

Comparison of three blood-processing techniques during and after cardiopulmonary bypass.

The return of extracorporeal circuit blood at the termination of cardiopulmonary bypass is an important feature of blood conservation during open heart procedures. However, the relative benefits and disadvantages of different circuit blood salvage methods remain unclear. Accordingly, the purpose of this study was to examine whether quantifiable differences exist between three different circuit blood-salvaging techniques: direct infusion, centrifugation, and ultrafiltration. Sixty patients with very similar preoperative characteristics were randomly assigned to each of the three groups, and blood coagulation screens, plasma profiles, and respiratory function were determined at 20 minutes and at 6 and 18 hours after cardiopulmonary bypass. Early after cardiopulmonary bypass (20 minutes), the plasma colloid osmotic pressure and fibrinogen and platelet concentrations were significantly higher with ultrafiltration (p < 0.05) versus those observed for the other two methods. The plasma thromboplastin times were significantly (p < 0.05) longer after cardiopulmonary bypass with centrifugation as compared to direct infusion and ultrafiltration. However, the coagulation profiles and plasma composition normalized by 18 hours after cardiopulmonary bypass with all three blood-salvaging methods. There were no significant differences in terms of blood utilization or chest tube drainage over the entire postoperative period among any of the circuit blood-salvaging methods. These results suggest that ultrafiltration of postcardiopulmonary circuit blood may preserve plasma colloid pressure and platelet concentration in the early postoperative period, but these differences do not persist. Thus, for routine cardiopulmonary bypass procedures, direct infusion, centrifugation, and ultrafiltration may all be satisfactory methods of circuit blood salvage.

Blood Coagulation Tests

St. Jude prosthesis for aortic and mitral valve replacement: a ten-year experience.

From January 1, 1979 through December 1990, 456 adult patients underwent isolated aortic (AVR) (254) or mitral (MVR) (202) valve replacement with the St. Jude prosthesis at the Medical University of South Carolina. Age ranged from 21 to 84 years (mean: 54 +/- 15 years for AVR; 51 +/- 13 years for MVR). Male sex predominated in the AVR group (66%) and female sex in the MVR group (64%). Ninety-two patients (20%) had associated coronary artery bypass grafting (AVR, 25%; MVR, 14%). There were 17 deaths (3.7%) occurring during the same hospitalization or within 30 days (AVR, 10/254 [3.9%]; MVR, 7/202 [3.5%]). Follow-up is 94.5% complete and ranges from 1.0 to 131 months (mean, 55 +/- 37 months; total, 2,073 patient-years). In the AVR group, 53 late deaths have occurred and actuarial survival is 80% +/- 3% at 5 years and 47% +/- 9% at 10 years. Twenty-one patients have sustained thromboembolic episodes (1.8%/patient-year), and the probability of remaining free of thromboembolism at 10 years is 67% +/- 13%. The mean improvement in New York Heart Association functional class from preoperative to postoperative is 3.1 +/- 0.76 to 1.6 +/- 0.84 (p < 0.0001). In the MVR group, there have been 41 late deaths, and the actuarial survival was 80% +/- 3% at 5 years and 63% +/- 5% at 10 years. Twenty-eight patients have sustained thromboembolic complications (2.9%/patient-year), and the probability of remaining free of thromboembolism at 10 years is 77% +/- 5%.(ABSTRACT TRUNCATED AT 250 WORDS)

Aortic Valve

Cerebral monitoring during implantation of automatic internal cardiac defibrillators.

Implantation of automatic internal cardiac defibrillators (AICD) for management of arrhythmias necessitates the induction of ventricular fibrillation (VF) to test the device adequately. The profound hypotension associated with induced arrhythmia and subsequent circulatory arrest may result in cerebral ischemia. To characterize cerebral ischemia, we used a five-lead Lifescan brain activity monitor to examine changes in cerebral activity in 10 patients having AICD placement. The duration of hypotension, as defined by a mean arterial pressure (MAP) < 50 mm Hg, was recorded, and the corresponding changes in brain activity were evaluated during 51 episodes of circulatory arrest. The number of episodes for each patient ranged from 2 to 14. The average duration of hypotension per episode was 26.2 seconds, with a range of 8 to 67 seconds. Brain activity changes characteristic of cerebral ischemia occurred in 46 of the 51 events (90%). Cerebral ischemia did not occur when the duration of hypotension was less than 16 seconds (5 episodes). The duration of cerebral ischemia ranged from 50 to 279 seconds (average 84.9 seconds) and did not correlate with the duration of hypotension or the order of the episodes in the testing sequence. These findings suggest that reevaluation of standard monitoring practice for AICD implantation may be warranted.

Brain Ischemia

Identification of patients at risk for excessive blood loss during coronary artery bypass surgery: thromboelastography versus coagulation screen.

In light of the potential morbidity associated with transfusion of blood products, a reliable preoperative screening test to identify cardiothoracic surgical patients who are at potential risk for increased intraoperative blood loss would be useful. Accordingly, we examined the efficacy of a variety of coagulation tests to predict intraoperative blood loss in 60 patients presenting for coronary artery bypass surgery (CABG). A complete coagulation screen, activated clotting time (ACT), and thromboelastograph (TEG) were performed before surgery. Intraoperative blood loss was determined by weighing sponges and measuring the quantity of blood in suction canisters. The duration of cardiopulmonary bypass was 100 +/- 4 min, and total surgery time was 5.0 +/- 0.1 h. Total crystalloid and colloid requirements were 5.5 +/- 0.2 and 1.4 +/- 0.1 L. Forty-eight percent of the patients required blood with an average requirement of 2.5 +/- 0.5 units. Total intraoperative blood loss averaged 1590 +/- 95 mL with a range from 640 to 3928 mL. Using multiple linear regression, all coagulation and TEG variables were used to model perioperative blood loss. Results showed that all components of the TEG failed to predict blood loss (r < 0.25, P > 0.78). However, three components of the routine coagulation assay, including bleeding time, prothrombin time, and platelet count could be modeled to predict perioperative blood loss (r = 0.75, P < 0.05). Although TEG has been shown to have potential in identifying postcardiopulmonary bypass coagulopathies, these results suggest that it does not appear to be useful in determining the coagulation status of CABG patients preoperatively.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged

Atrioventricular pacing in congenital heart disease.

We have attempted to optimize cardiac performance in patients with congenital heart disease requiring artificial pacing by using pacemakers capable of both sensing and pacing both the atrium and the ventricle (DDD). We reviewed our results with 88 patients receiving DDD devices to determine the safety and dependability of these devices in children. Age ranged from 1 hour to 25 years. Endocardial leads were used in 68 patients, whereas epicardial leads were used in 20 patients. Previous cardiac procedures had been done in 30 patients. There were nine deaths but none due to pacemaker malfunction. Endocardial leads functioned better than epicardial leads. Ninety-eight percent of patients with endocardial leads and 62% of patients with epicardial leads were maintained in the DDD mode. Complications were infrequent and all were corrected without long-term sequelae. The DDD mode may offer considerable benefits to children who require artificial pacing. Our data allow us to conclude that most children can be paced safely and dependably in the DDD mode.

Adolescent

Retrograde versus antegrade cardioplegia: impact on right ventricular function.

Retrograde cardioplegia administered through the coronary sinus has several documented advantages over antegrade cardioplegia but has been thought to provide inadequate right ventricular myocardial protection. We prospectively compared the effects of retrograde and antegrade cardioplegia on right ventricular performance in patients undergoing myocardial revascularization. Two groups of similar age, extent of disease, and preoperative left ventricular ejection fraction received retrograde (n = 16) or antegrade (n = 14) crystalloid cardioplegia. A right ventricular rapid-response thermistor catheter, previously developed and validated in our institution, was used to measure right atrial pressure, pulmonary artery pressure, right ventricular ejection fraction, end-diastolic volume index, and stroke volume index before bypass (baseline) and at several intervals after bypass. There were no differences in cross-clamp time, heart rate, cardiac enzymes, inotrope requirements, or arrhythmias between the two groups. Right ventricular parameters were equivalent in both groups at all time intervals except 30 minutes after bypass, at which time right ventricular end-diastolic volume index was lower (80 +/- 6 versus 93 +/- 6 mL/m2; p less than 0.05) and right ventricular stroke volume index was higher (35 +/- 3 versus 29 +/- 2 mL/m2, p less than 0.05) in the retrograde group compared with the antegrade group, indicating better right ventricular function with retrograde cardioplegia early after bypass. In both groups, right ventricular end-diastolic volume index was higher than baseline (p less than 0.05) during the first 4 hours after bypass. No other important differences were found.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged

Use of a combined right ventricular ejection fraction-oximetry catheter system for coronary bypass surgery.

OBJECTIVE: To evaluate the reproducibility and accuracy of a new pulmonary artery catheter system that provides both right ventricular ejection fraction and continuous venous oxygen saturation monitoring. DESIGN: Criterion standard study. SETTING: University medical center. PATIENTS: A consecutive sample of ten patients undergoing elective coronary artery bypass surgery provided informed consent for the study. Exclusion criteria included emergency surgery or clinically important preoperative tricuspid regurgitation as assessed by echocardiography. None of the patient sample was excluded. MEASUREMENTS: Catheter-derived mixed venous and arterial oximetry data were compared with simultaneous values obtained using conventional laboratory cooximetry methods. Measurements were performed before cardiopulmonary bypass and intermittently up to 48 hrs after cardiopulmonary bypass. The variability of cardiac output and computed right ventricular ejection fraction was also assessed concurrently with the oximetry analysis. RESULTS: A significant correlation was observed for mixed venous oxygen saturation between catheter-derived and laboratory cooximetry data (r2 = .81, p < .01). Similarly, arterial oxygen saturation values obtained from pulse oximetry and laboratory values were significantly related (r2 = .81, p < .01). The coefficient of variation for each set of five repeated measurements for cardiac output was 8%, and for computed right ventricular ejection fraction, it was 16%. CONCLUSIONS: The combined catheter system provides the means to monitor both mixed venous oxygen saturation and right ventricular ejection fraction. These data provide a reliable and detailed assessment of cardiopulmonary function that should prove beneficial in the critical care setting.

Aged

Cardiac pacing in neonates, infants, and preschool children.

A series of 37 children < 5 years old at pacemaker implant were followed from 1 to 105 months. Five of 37 patients required reoperation for battery depletion while two required reoperation for exit block of epicardial ventricular leads. Each patient paced in the DDD or AAI mode was still in the original mode at the end of follow up.

Cardiac Pacing, Artificial

Mitral valve replacement with and without chordal preservation in patients with chronic mitral regurgitation. Mechanisms for differences in postoperative ejection performance.

BACKGROUND: Standard mitral valve replacement (MVR) in patients with chronic mitral regurgitation consistently results in a decrease in postoperative left ventricular (LV) ejection performance. This fall in ejection performance has been attributed, at least in part, to unfavorable loading conditions imposed by the elimination of the low-impedance pathway for LV emptying into the left atrium. In contrast to standard MVR in which the chordae tendineae are severed, however, MVR with chordal preservation (MVR-CP) does not usually decrease LV ejection performance despite similar removal of the low-impedance pathway. The purpose of the present study was to define the mechanisms responsible for this discordance in postoperative ejection performance between MVR with and without chordal preservation. METHODS AND RESULTS: Echocardiography and sphygmomanometer blood pressures were obtained in 15 patients with pure chronic mitral regurgitation before and 7-10 days after mitral valve surgery. These measurements were used to calculate ventricular volume, wall stress, and ejection fraction. Seven patients underwent MVR with chordal transection (MVR-CT), and eight patients underwent MVR-CP. MVR-CT resulted in no postoperative change in LV end-diastolic volume, a significant increase in LV end-systolic volume, a significant increase in end-systolic stress, from 89 +/- 9 to 111 +/- 12 g/cm2 (p < 0.05), and a significant decrease in ejection fraction, from 0.60 +/- 0.02 to 36 +/- 0.02 (p < 0.05). In contrast, patients who underwent MVR-CP had a significant decrease in LV end-diastolic and end-systolic volumes. End-systolic wall stress actually fell from 95 +/- 6 to 66 +/- 6 g/cm2 (p < 0.05), and ejection fraction was unchanged (0.63 +/- 0.01 before and 0.61 +/- 0.02 after mitral valve surgery) instead of reduced. CONCLUSIONS: MVR-CT resulted in a decrease in ejection performance caused in part by an increase in end-systolic stress, which in turn increased end-systolic volume. Conversely, MVR-CP resulted in a smaller LV size, allowing a reduced end-systolic stress and preservation of ejection performance despite closure of the low-impedance left atrial ejection pathway.

Chordae Tendineae

Prospective, randomized trial of palliative treatment for unresectable cancer of the esophagus.

To evaluate the best method of palliation for obstructing nonresectable squamous cell carcinoma of the mid or distal esophagus, 27 patients were prospectively randomized to one of three treatment arms: (1) esophageal intubation with an Atkinson tube (AT, 10 patients), (2) esophageal intubation followed by radiation therapy (AT/RT, 8 patients), and (3) endoscopic laser therapy followed by irradiation (L/RT, 9 patients). Pretreatment characteristics were similar in the three groups. There was no procedure-related mortality. There were eight total complications related to the tube and none related to laser treatment (p = 0.02). Mean survival was 119 days in the AT group, 72 days in the AT/RT group, and 169 days in the L/RT arm (p = not significant). Quality of survival was most dependent on swallowing ability, and the swallowing score increased by 2.3 units in the AT group, 1.8 units in the AT/RT group, and 1.4 units in the L/RT group (p = not significant). Adding RT to laser therapy significantly increased time in treatment (mean, 38.7 days) when compared with the AT group (mean, 12.5 days) (p less than 0.001). However, only 1 patient required repeat laser ablation. It is concluded that AT and L/RT result in good palliation as measured by relief of dysphagia and survival time. However, morbidity of AT is significantly greater than that of L/RT. Laser and radiation therapy with a reduced total dosage of RT or with a change in fractionation schedule to limit treatment time is the preferred method of palliation.

Adult

Cardiac surgery for patients maintained on chronic hemodialysis.

This study confirms and extends the available information about cardiac surgery in patients with chronic renal failure. With appropriate precautions, CABG and valve repair can be carried out in these patients without significant increase in operative mortality or morbidity as compared to patients with normal renal function. However, these patients remain susceptible to accelerated atherosclerosis in native vessels as well as bypass grafts and to complications (thromboembolism, infection) of prosthetic valves. Accordingly, while these patients are often significantly improved as a result of their cardiac surgery, long term outlook is guarded.

Adult