Search PubMed⌕ Search

Biomedical subjects

J M Kabo

Publications and source records attributed to J M Kabo.

At least 55 records · Page 3Linked to original sources

Endoprosthetic replacement for stage IIB osteosarcoma.

Over an eight-year period, 100 patients with IIB osteosarcoma have been managed. Eighty-one were treated with limb-salvage procedures, 78 of which involved reconstruction utilizing endoprostheses. Only 19 patients received amputation as the primary treatment for local control. Since 1984, all patients received preoperative and post-operative adjuvant chemotherapy. Those patients who received chemotherapy had a statistically significant improvement in five-year survival over those who did not (57% and 32%, respectively, p = 0.014). The functional results were good overall, with excellent results seen in distal femoral reconstruction. Twenty-eight of the 78 patients treated with endoprosthetic reconstruction experienced 30 complications (36%). Mechanical failure was the most common complication (10%) but was generally correctable. The local recurrence rate was 5% and the infection rate was 3%. Local complications were manageable. A statistical analysis revealed that the relative risk of patient death was 2.5 times higher than prosthesis failure for the 78 patients with endoprosthetic reconstruction. The intermediate-term results, with a median follow-up period of 43 months, remains encouraging.

Adolescent↗

Continuous passive motion versus immobilization. The effect on posttraumatic joint stiffness.

Management of intraarticular fractures is often complicated by joint stiffness long after bony healing has occurred. The following experiments provide biomechanical evidence for the effectiveness of CPM in maintaining joint function in stabilized articular injuries. The ankles of ten adolescent New Zealand white rabbits were penetrated by Steinmann pins to create an intraarticular injury. One limb of each animal was immobilized, and the contralateral limb was placed in a continuous passive motion (CPM) machine for three weeks. Joint stiffness of each ankle was quantified with an arthrograph before injury and after three weeks of treatment. Hindlimb volumes were recorded before injury and monitored at weekly intervals using a water-displacement method. Joint stiffness increased 2.6 times the preinjury levels in limbs that were immobilized for three weeks. There was no statistically significant increase in joint stiffness in ankles treated with CPM compared to preinjury values. The posttraumatic difference between the CPM-treated and immobilized limbs was highly significant; limb swelling was not affected by CPM.

Animals↗

Direct measurement of resultant forces in the anterior cruciate ligament. An in vitro study performed with a new experimental technique.

A new technique was used to measure the resultant forces in the anterior cruciate ligament during a series of loading experiments on seventeen fresh-frozen cadaver specimens. The base of the ligament's tibial attachment was mechanically isolated with a coring cutter, and a specially designed load-transducer was fixed to the bone-plug that contained the ligament's tibial insertion so that the resultant forces were directly measured by the load-cell. Although the magnitudes of values for forces varied considerably between specimens for a given test condition, the patterns of loading with respect to direction of loading and the angle of flexion of the knee were remarkably consistent. Passive extension of the knee generated forces in the ligament only during the last 10 degrees of extension; at 5 degrees of hyperextension, the forces ranged from fifty to 240 newtons (mean, 118 newtons). When a 200-newton pull of the quadriceps tendon was applied to extend a knee slowly against tibial resistance, however, the force in the ligament increased at all angles of flexion of the knee. Internal tibial torque always generated greater forces in the ligament than did external tibial torque; higher forces were recorded as the knee was extended. The greatest forces (133 to 370 newtons) were generated when ten newton-meters of internal tibial torque was applied to a hyperextended knee. Fifteen newton-meters of applied varus moment generated forces of ninety-four to 177 newtons at full extension; fifteen newton-meters of applied valgus moment generated a mean force of fifty-six newtons, which remained unchanged with flexion of the knee. The force during straight anterior translation of the tibia was approximately equal to the anterior force applied to the tibia. The application of 925 newtons of tibiofemoral contact force reduced the mean force in the ligament that was generated by 200 newtons of anterior pull on the tibia by 36 per cent at full extension and 46 per cent at 20 degrees of flexion.

Aged↗

Strength of initial mechanical fixation of screw ring acetabular components.

This study was conducted to determine the effects of design on the initial fixation of several types of screw-ring acetabular components. The components were tested in polyurethane foam to assess relative screw fixation strengths with a consistent material. Embalmed pelves from anatomic specimens were used to conduct paired tests between designs that showed large differences in insertional torque to failure in foam. The quality of the initial fixation in foam was found to be dependent on the design features of the components. Components with widely spaced, deep threads, and minimal thread interruptions offered the strongest initial fixation in foam. Tests in bone revealed a wide range of fixation strengths reflecting the variability in bone quality. No differences in fixation strength attributable to component design were observed in bone. When the insertional failure torque was greater than 60 N.m, one-half of the pelves fractured, and these fractures occurred with all designs. At failure torques less than 60 N.m, failure was predominantly due to thread strippage of the screw, with only two of 20 specimens experiencing pelvic fracture.

Acetabulum↗

Preliminary results of an off-the-shelf press-fit stem. The anthropometric total hip femoral component using exact-fit principles.

The use of custom-manufactured femoral prostheses as part of routine total hip arthroplasty (THA) has been suggested. However, there are several disadvantages, including possible inaccuracy of fit, inadequate instrumentation, and high cost. A series of 28 THAs (including 18% for revision of failed, cemented THA) using a press-fit prosthesis of contemporary design were investigated. The average follow-up period was 28 months (range, 12-49 months). Clinical results were overall very good, even in revision cases. Roentgenographic changes included rapid femoral remodeling, which may increase component stability. Given the clinical and roentgenographic results obtained in this complex-problem patient population, it is difficult to justify the use of custom femoral components in routine THA.

Adult↗

The anthropometric total hip femoral prosthesis. Preliminary clinical and roentgenographic findings of exact-fit cementless application.

Total hip arthroplasty in the young patient remains a considerable challenge. Cemented arthroplasty has an unacceptably high failure rate. Porous ingrowth designs are one alternative, but bone ingrowth is unpredictable, thigh pain is a frequent clinical finding, stress shielding is often observed, revision is more complicated, and microporous components are mechanically weaker. A new anthropometric femoral component has been designed with a goal of long-term stability through osseointegration. The prosthesis is optimized for canal fill in the distal metaphysis and proximal diaphysis. The components are manufactured in 16 sizes, with cutting broaches precisely machined to the same dimensions to provide an exact fit to the femur. The high-strength TiAl6V4 alloy stem is combined with heads of either CoCr alloy or alumina (Al2O3) for reduced polyethylene wear. The 135 degrees neck-shaft angle and modular design allow for restoration of the abductor lever arm. Because the prosthesis is not porous coated, it is also suitable for use with cement. In cemented application, the prosthesis shape provides an optimal cement mantle. Seventy-one total hip arthroplasties have been performed using the Anthropometric Total Hip (ATH) prosthesis: 31 with exact-fit cementless fixation and 40 with cement. Of those using cementless fixation, 21 have been followed for more than one year (mean, 20 months; range, 12-48 months). The early clinical findings are as good as, or superior to, other cementless designs used at the authors' institution. Stress remodeling of the proximal femur occurs early and stabilizes by one year. The observed changes appear to improve the stability of the prosthesis. Clinical and roentgenographic findings suggest the osseointegration of the ATH femoral component.

Adult↗

The effects of dexamethasone on periarticular swelling and joint stiffness following fracture in a rabbit hindlimb model.

An established rabbit hindlimb model was used to determine the effects of systemic steroid administration on posttraumatic limb swelling and joint stiffness. Dexamethasone acetate was administered intramuscularly to the test rabbits in one of four doses two hours following fracture as well as one and two weeks later. Dexamethasone did not produce a significant decrease in swelling but did produce a statistically significant dose-dependent decrease in ankle stiffness compared to controls. Tibia torsional strength to failure was not adversely affected.

Animals↗

The effects of two nonsteroidal antiinflammatory drugs on limb swelling, joint stiffness, and bone torsional strength following fracture in a rabbit model.

Using a rabbit distal tibia fracture model treated by immobilization for three weeks, the effects of two nonsteroidal antiinflammatory drugs on postfracture limb swelling, joint stiffness, and torsional bone strength were examined. Limb swelling in rabbits treated with low-dose piroxicam was reduced by 39%, and high-dose piroxicam reduced limb swelling by 86%. Flunixin, tested at one dose, reduced swelling by 53%. Neither piroxicam nor flunixin affected ankle stiffness or tibia torsional strength.

Animals↗

Efficacy of soft splints in reducing severe knee-flexion contractures.

This study evaluated the effectiveness of soft splints made from polyurethane foam in reducing severe knee-flexion contractures of patients with cerebral palsy. The splints were applied nightly over a period of 10 months. Knee-flexion contractures were reduced by an average of 24 degrees in all patients. Younger patients generally presented with less severe initial contractures and had the greatest percentage of improvement. When used on a single limb when bilateral contractures were present, sympathetic reduction of the contracture occurred to varying degrees in the unsplinted limb. It is recommended that the splints be replaced regularly to maximize their effectiveness. The benefit-to-cost ratio is extremely high and their low cost makes soft splints feasible for use in developing countries and by low-income families.

Adolescent↗

The effects of dimethyl sulfoxide on posttraumatic limb swelling and joint stiffness. A review and an experimental study in rabbits.

Dimethyl sulfoxide (DMSO) is an inorganic compound with many interesting in vitro properties, including the ability to scavenge oxygen-free radicals. DMSO has been used to treat a variety of clinical conditions, especially musculoskeletal trauma, but valid data regarding its effectiveness are lacking. This paper reviews the pharmacology of DMSO and reports on its effectiveness in reducing posttraumatic limb swelling and ankle joint stiffness in a rabbit hind limb model. The left and right hind limbs of the test and control animals were instrumented and fractured identically. DMSO was applied daily to the skin of only one limb in the test animals. DMSO reduced postinjury ankle stiffness in both ankles of the test rabbits by 41% but had no effect on limb swelling compared to control rabbits. Postulated mechanisms of decreased joint stiffness include oxygen-free radical scavenging and inhibition of fibroblast proliferation.

Animals↗

Comparison of in vivo cementless acetabular fixation.

Cementless fixation in total hip arthroplasty is increasingly popular because of the failure rates of cemented components, particularly in younger patients. The reported European studies with cementless acetabular implants and the relatively short-term American studies suggest that loosening is not a problem with any of the designs in clinical use. This point of view is reminiscent of that regarding cemented acetabular components prior to the realization that cemented acetabular failure was a delayed long-term phenomenon. Cementless acetabular components are principally of two types, threaded and porous coated. Prior to this study, there was little clinical or experimental evidence to indicate which design gains superior fixation and which is most likely to maintain long-term fixation and durability. Fixation of threaded and porous-coated components was evaluated mechanically and histologically in dogs after weight-bearing periods of two and six months. The threaded specimens were significantly looser than the porous-coated specimens at both two and six months. There was a trend toward loosening of both types of components with time. Fibrous tissue alone appeared to invest all of the threaded components, whereas bone and fibrous-tissue ingrowth appeared to incorporate the porous components. The mineral apposition rate for the components was not significantly different between the two components or between different regions in the specimens.

Acetabulum↗

The Dana total shoulder arthroplasty.

Fifty-six Dana unconstrained total shoulder arthroplasties in forty-seven patients were followed for a minimum of two years. The preoperative diagnoses included osteoarthritis, rheumatoid arthritis, traumatic arthritis, avascular necrosis, failed hemiarthroplasty, and failed total shoulder arthroplasty of another design. For all of the patients, the average rating for pain improved from 3 points preoperatively to 8 points postoperatively, and the average rating for function improved from 3 to 7 points. The ranges of abduction and of external rotation improved substantially in the shoulders that were affected by osteoarthritis, rheumatoid arthritis, or osteonecrosis. Ten patients were treated with a hooded glenoid component, designed to improve stability in shoulders in which the rotator cuff is deficient. In these shoulders, both the rating for pain and the rating for function improved, although the range of motion did not. Complications that required revision of the arthroplasty developed in five shoulders in which a regular component had been implanted and in two that had a hooded glenoid component. A radiolucent line developed at the bone-cement interface of the glenoid component in fifty-three shoulders, but only two revisions were done for loosening of the glenoid component.

Adult↗

The effects of intermittent passive exercise on joint stiffness following periarticular fracture in rabbits.

To determine the effects of intermittent passive motion on joint stiffness following periarticular fracture, bilateral distal tibia fractures were produced in 31 rabbits. Following immobilization and fracture union at three weeks, one ankle on each rabbit underwent passive exercise daily until sacrifice at six weeks. The contralateral ankle remained immobile, except for weekly stiffness determinations. Passive exercise produced limb swelling and resulted in temporarily decreased ankle stiffness to, but not significantly below, control values. Between exercise sessions, the exercised ankles became significantly stiffer than the contralateral immobilized ankles. The cause of stiffness was not determined, but extrapolation from other work would suggest that the regimens of intermittent passive exercise tested in this study additionally traumatized the healing tissues surrounding the fracture.

Animals↗

Biomechanical effects of point configuration in Kirschner-wire fixation.

The drilling and bone holding properties of Kirschner wires of three different tip designs have been investigated. The tip designs studied were the commercially available trocar- and diamond-shaped tips and the homemade cut tip produced by cutting the pin obliquely with wire cutters. Thirteen canine metacarpals were drilled with wires of each tip design at 400 and 800 rpm. A servohydraulic test machine (Materials Test Systems, Minneapolis, MN) simultaneously measured axial loads, torque, and displacement during insertion and pull-out. Kirschner wires of each tip configuration were also placed in seven canine metacarpals for a three-week in vivo test. After the animals were killed, peak pull-out forces were measured and compared with in vitro results. The trochar-tipped wire displayed the highest required torque and axial load to penetrate bone. It also demonstrated the highest pull-out force immediately after drilling, especially when inserted at the low drill speed. After placement for three weeks, pull-out force of the diamond-tipped wire equaled the trochar. The homemade cut wire consistently yielded inferior holding properties. For immediate and sustained strong fixation in bone, a wire with a trochar tip configuration should be inserted at low drill speeds.

Animals↗

Computerized anatomy instruction.

A self-paced gross anatomy teaching package is under development using computer-generated anatomic images controlled by branching instructional software on a personal computer. The package is designed to overcome several problems encountered in the traditional study of anatomy. The capabilities, strengths, and weaknesses of computer-assisted instruction are highlighted.

Anatomy↗

Canine porous resurfacing hip arthroplasty. Long-term results.

Long-term experimental data support the hypothesis that biologic bone ingrowth into porous surfaces in a hip-resurfacing model is a viable alternative to stem-type porous implants. Ingrowth of bone was demonstrated in long-term canine arthroplasty. The components were well fixed and stable at the time of sacrifice, although ingrowth occurred to varying degrees. The ingrowth and quality of remodeling was influenced by stress. Dislocations were overcome by a change in surgical technique. Loosening and neck fractures were associated with insufficient stability at operation or to component impingement (prevented by modifications of design). The formation of metal debris-filled cysts is a concern and appeared to be associated with the poor quality of porous sintering and possibly abrasion. The effects of increased surface area of the porous components such as increased corrosion products on biologic compatibility are still not well defined and require further research and longer follow-up examination.

Acetabulum↗

The effects of pressurization on fracture swelling and joint stiffness in the rabbit hind limb.

Long bone fractures frequently cause limb swelling and joint stiffness, and the two effects are generally assumed to be related, an assumption long held but rarely tested. The authors investigated limb swelling and joint stiffness in rabbits with experimental 28-day healing fractures. Eleven control rabbits were treated with bilateral hind limb skeletal fixation and unilateral distal tibia fractures. Subsequent limb swelling occurred bilaterally, but it was significantly greater on the side fractured. All fractures healed. Ankles in both fractured and unfractured limbs became significantly stiffer, compared with preinjury values, but ankles in the fractured limbs became significantly stiffer than those in the unfractured control limbs. Air pressure of 10 mmHg above atmospheric pressure was applied for four days to newly fractured limbs in 11 additional rabbits. Pressurization reduced swelling but did not significantly affect ankle stiffness. In general, reduction in postfracture swelling by application of external pressure did not significantly affect adjacent joint stiffness.

Animals↗

Comparative experience with canine and human cementless acetabular components.

Bone ingrowth in the porous canine implants does occur; the early clinical results are indeed encouraging and justify further investigation. The quality of ingrowth as measured by depth and extent in the dog was stress-related. Remodelling was superior in the more compliant or elastic acetabular components without an interposed metal shell. No human specimens have been retrieved thus far, but we are encouraged because the results in the canine model with acrylic-fixed implants were comparable to the results we subsequently observed in human THARIES implantation. Those were initially excellent, but with time radiolucencies increased and loosening occurred. The quality of the canine biologic ingrowth suggests optimism for secure and durable fixation. Our patients have continued to improve through the follow-up period. There has not been a single case in which a qualitative increase in pain occurred over the cemented versions after operation. The technical problems of the surgical procedure have been overcome, but it must be performed precisely to achieve the initial inherent stability to assist in biologic ingrowth. The operative procedures in this series have been performed by or under the direct supervision of the senior author. As our competence has grown, we have applied the procedure to younger patients and those who have bone stock deficiency. One of the major advantages of the biologic ingrowth systems is the facility to graft cysts and defects. For humans, the current chamfered cylinder is an extremely bonestock-conservative procedure when combined with reaming of the femoral head to the neck size. Although space is limited in resurfacing, we have been able to achieve a minimum 4-mm bearing thickness of polyethylene. We believe that the compliant mesh chamfered cylinder system provides excellent stability. However, the hemispheric component, although technically more difficult to seat and fix, has definite applications in bonestock deficiency and with further refinement will be useful in primary replacements as well. Nevertheless, because of the uncertain future of any type of implant, especially new, we have encouraged the patients to follow a careful postoperative management program and refrain from heavy activity during the first year. Many are active and some are now participating in athletics, although this is certain to shorten the life of these implants just as was observed in acrylic-fixed devices. The biologic problems of interface corrosion, migration, and metal ion transfer indicate that these implants must be followed for longer periods. Therefore it seems unwise to extend this technology to a wide clinical use at this time.

Adult↗