Search PubMed⌕ Search

Biomedical subjects

J M Jenkins

Publications and source records attributed to J M Jenkins.

At least 55 records · Page 3Linked to original sources

Molecular cloning, expression and chromosomal localization of a human gene encoding a 33 kDa putative metallopeptidase (PRSM1).

The zincins are a superfamily of structurally-related Zn(2+)-binding metallopeptidases which play a major role in a wide range of biological processes including pattern formation, growth factor activation and extracellular matrix synthesis and degradation. In this paper we report the identification and complete primary structure of a novel 33 kDa protein which contains the zinc-binding HEXXH motif found in the zincin superfamily. We have named this novel protein PRSM1 (PRoteaSe, Metallo, number 1). The gene was identified by the immunoscreening of a human placental cDNA library using polyclonal antibodies raised to the 70 kDa human matrix metalloendopeptidase, type III procollagen N-proteinase [Halila, R. and Peltonen, L. (1986) Purification of human procollagen type III N-proteinase from placenta and preparation of antiserum. Biochem. J. 239, 47-52]. The protein is found in placenta and cultured osteosarcoma cells. PRSM1 could share sequence homology with the type III procollagen N-proteinase. The prsm1 gene is represented once in the human genome and is localized on chromosome 16 (q24.3).

Amino Acid Sequence↗

Ground-based detectability of terrestrial and Jovian extrasolar planets: observations of CM Draconis at Lick Observatory.

The detection of terrestrial-sized extrasolar planets from the ground has been thought to be virtually impossible due to atmospheric scintillation limits. However, we show that this is not the case especially selected (but nevertheless main sequence) stars, namely small eclipsing binaries. For the smallest of these systems, CM Draconis, several months to a few years of photometric observations with 1-m-class telescopes will be sufficient to detect the transits of any short-period planets of sizes > or = 1.5 Earth radii (RE), using cross-correlation analysis with moderately good photometry. Somewhat larger telescopes will be needed to extend this detectability to terrestrial planets in larger eclipsing binary systems. (We arbitrarily define "terrestrial planets" herein as those whose disc areas are closer to that of Earth's than Neptune's i.e., less than about 2.78 RE.) As a "spin-off" of such observations, we will also be able to detect the presence of Jovian-mass planets without transits using the timing of the eclipse minima. Eclipse minima will drift in time as the binary system is offset by a sufficiently massive planet (i.e., one Jupiter mass) about the binary/giant-planet barycenter, causing a periodic variation in the light travel time to the observer. We present here an outline of present observations taking place at the University of California Lick Observatory using the Crossley 0.9-m telescope in collaboration with other observatories (in South Korea, Crete, France, Canary Islands, and New York) to detect or constrain the existence of terrestrial planets around main sequence eclipsing binary star systems, starting with CM Draconis. We demonstrate the applicability of photometric data to the general detection of gas giant planets via eclipse minima timings in many other small-mass eclipsing binary systems as well.

Astronomy↗

A matched filter method for ground-based sub-noise detection of terrestrial extrasolar planets in eclipsing binaries: application to CM Draconis.

The photometric detection of extrasolar planets by transits in eclipsing binary systems can be significantly improved by cross-correlating the observational light curves with synthetic models of possible planetary transit features, essentially a matched filter approach. We demonstrate the utility and application of this transit detection algorithm for ground-based detections of terrestrial-sized (Earth-to-Neptune radii) extrasolar planets in the dwarf M-star eclipsing binary system CM Draconis. Preliminary photometric observational data of this system demonstrate that the observational noise is well characterized as white and Gaussian at the observational time steps required for precision photometric measurements. Depending on planet formation scenarios, terrestrial-sized planets may form quite close to this low-luminosity system. We demonstrate, for example, that planets as small as 1.4 Earth radii with periods on the order of a few months in the CM Draconis system could be detected at the 99.9% confidence level in less than a year using 1-m class telescopes from the ground. This result contradicts commonly held assumptions limiting present ground-based efforts to, at best, detections of gas giant planets after several years of observation. This method can be readily extended to a number of other larger star systems with the utilization of larger telescopes and longer observing times. Its extension to spacecraft observations should also allow the determination of the presence of terrestrial-sized planets in nearly 100 other known eclipsing binary systems.

Algorithms↗

A:V = 1:1 cardiac arrhythmia detection by VA interval analysis.

Dual-chamber-sensing implantable-cardioverter defibrillators are soon expected to replace ventricular sensing devices. The addition of an atrial sensing lead will dramatically improve the specificity of arrhythmia detection. Even when using combined ventricular and atrial rate criteria, ambiguity in the case of atrial tachycardia with: anterograde conduction versus ventricular tachycardia with: retrograde conduction still remains. The introduction of dual-chamber sensing in antitachycardia devices allows for additional features, such as the measurement of atrioventricular (AV) and ventriculoatrial (VA) intervals. This study investigated relationships between AV and VA intervals to address problems arising in tachycardias with confounding 1:1 relationships. Thirty-one passages of 1:1 anterograde conduction from nine patients during atrial pacing at cycle lengths of 600-300 ms and 24 passages of 1:1 retrograde conduction from eight patients during ventricular pacing at cycle lengths of 600-300 ms were analyzed. Moving averages of three successive VA interval measurements were used to develop a criterion to be implemented into an algorithm to reduce ambiguity. Five randomly selected ventricular pacing passages were used as a training set. Upper and lower VA interval boundaries (234 ms and 132 ms) determined from the training set were used to classify 1:1 retrograde activation. To account for premature beats and outliers, the boundary criterion required 9 of 12 of the most recent moving averages to fall within the upper and lower limits. Of the 19 analyzed passages of ventricular pacing, 18 (95%) were correctly classified using the VA interval as an added feature. Of the 31 atrial pacing passages, 24 (77%) were correctly classified. Using only atrial or ventricular rates, all 1:1 tachycardias in this patient sample would be classified as ventricular tachycardia, resulting in false shocks. Specificity of diagnosis in ambiguous 1:1 tachycardias can be increased using VA interval measurements at the cost of minimum loss in sensitivity for ventricular tachycardia detection. This algorithm imposes little in additional computation for dual-chamber-sensing implantable-cardioverter defibrillators and greatly reduces the possibility of false shocks in 1:1 supraventricular tachycardias.

Algorithms↗

Antibiotic treatment based on seminal cultures from asymptomatic male partners in in-vitro fertilization is unnecessary and may be detrimental.

We questioned the policy of routine microbiological culture of semen prior to in-vitro fertilization (IVF) with a view to prescribing antibiotics to reduce the risk of introducing seminal infection into the embryo culture system. An initial retrospective study examined serum microbiology reports of 449 couples undergoing IVF or gamete intra-Fallopian transfer (GIFT). In semen samples taking >/=1 days to reach the microbiology laboratory compared with same-day delivery there was increased frequency of significant culture of enterococci (27 versus 15%, P < 0.01). In samples taking >/=2 days there was increased frequency of significant culture of Gram-negative bacilli (31 versus 12%, P < 0.01) and of overall culture of other potentially pathogenic organisms (26 versus 14%, P < 0.01). We questioned diagnostic accuracy and relevance. Therefore, in a prospective study, semen and high vaginal swabs obtained on the day of oocyte collection were cultured from 100 couples having IVF or GIFT, of whom 52 male partners had been treated with antibiotics following positive pre-IVF semen culture. The presence of bacteria in semen samples used only for IVF (n = 90) did not reduce fertilization rates nor lead to infection of the embryo culture system. However, there was an increased incidence of significant culture of vaginal Gram-negative bacilli in patients with treated partners compared with untreated partners [15/52 (29%) versus 5/48 (10%), P < 0.05]. Thus antibiotic therapy in the male partner may increase the likelihood of inoculation of antibiotic-resistant pathogenic bacteria from the vagina into the embryo culture system during vaginal oocyte collection. In asymptomatic patients, microbiological screening of semen samples prior to IVF treatment and subsequent treatment with antibiotic therapy in those with positive cultures appears to be unnecessary and may be detrimental to IVF outcome.

Adult↗

Infant survival after cesarean section for trauma.

HYPOTHESIS: Emergency cesarean sections in trauma patients are not justified and should be abandoned. SETTING AND DESIGN: A multi-institutional, retrospective cohort study was conducted of level 1 trauma centers. METHODS: Trauma admissions from nine level 1 trauma centers from January 1986 through December 1994 were reviewed. Pregnant women who underwent emergency cesarean sections were identified. Demographic and clinical data were obtained on all patients undergoing a cesarean section. Fetal distress was defined by bradycardia, deceleration, or lack of fetal heart tones (FHTs). Maternal distress was defined by shock (systolic blood pressure < 90) or acute decompensation. Statistical analyses were performed. RESULTS: Of the 114,952 consecutive trauma admissions, more than 441 pregnant women required 32 emergency cesarean sections. All were performed for fetal distress, maternal distress, or both. Overall, 15 (45%) of the fetuses and 23 (72%) of the mothers survived. Of 33 fetuses delivered, 13 had no FHTs and none survived. Twenty infants (potential survivors) had FHTs and an estimated gestational age (EGA) of greater than or equal to 26 weeks, and 75% survived. Infant survival was independent of maternal distress or maternal Injury Severity Score. The five infant deaths in the group of potential survivors resulted from delayed recognition of fetal distress, and 60% of these deaths were in mothers with mild to moderate injuries (Injury Severity Score < 16). CONCLUSIONS: In pregnant trauma patients, infant viability is defined by the presence of FHTs, estimated gestational age greater than or equal to 26 weeks. In viable infants, survival after emergency cesarean section is acceptable (75%). Infant survival is independent of maternal distress or Injury Severity Score. Sixty percent of infant deaths resulted from delay in recognition of fetal distress and cesarean section. These were potentially preventable. Given the definition of fetal viability, our initial hypothesis is invalid.

Adolescent↗

Endovascular grafting of abdominal aortic aneurysms. A preliminary study.

OBJECTIVE: The authors report the experience of a single investigational center involving two Phase I and a Phase II clinical trials approved by the Food and Drug Administration (FDA) for the transfemoral implantation of woven Dacron grafts for abdominal aortic aneurysms. SUMMARY BACKGROUND DATA: In 1993, EndoVascular Technologies, Inc. ([EVT]; Menlo Park, CA), began an FDA-approved clinical trial of repair of abdominal aortic aneurysms by transfemoral placement of a tube endograft. Subsequently, a bifurcated endograft trial was started. This the first single institution report using the EVT endograft for both tube and bifurcated aortic replacement. METHODS: Seventeen patients were enrolled in two Phase I and one Phase II clinical trials. The Phase I tube graft trial and the Phase I bifurcated graft trial were nonrandomized studies. The Phase II tube graft trial consisted of a randomized prospective control trial of open endoaneurysmorrhaphy versus transfemoral placement of an endograft. RESULTS: Seventeen patients were enrolled in the trial. The graft was placed successfully in all but one patient. Five patients randomized to open procedure and one declined to participate. Eleven patients with endografts are available for follow-up. One graft has been explanted for attachment system migration. One patient is a late failure because of persistent filling of the aneurysm sac. CONCLUSION: Transfemoral placement of an endovascular graft is a viable and effective treatment of abdominal aortic aneurysms in the short term. Use of a bifurcated endograft will open the procedure to more patients. The ideal attachment system and graft material await long-term implantation follow-up.

Adult↗

Augmented two-channel arrhythmia detection: an efficient diagnostic method for implantable devices.

ICDs are highly effective in preventing sudden cardiac death. However, inappropriate device shocks caused by false-positive diagnoses are estimated to happen in 20% of all patients. The need for implantable electrical devices to detect with precision arrhythmias requiring therapy has spawned a variety of proposals for better means of tachycardia identification. To address this problem, the augmented two-channel arrhythmia detection (A2CAD) algorithm, a real-time scheme utilizing timing and morphology from both the atrial and ventricular channels, is introduced. The algorithm uses rate detection as a first stage and augments this with morphological signal analysis in rhythms that confound the rate only diagnoses. The software executes in real-time (online), and has been tested on 60 passages of two-channel intracardiac signals. The following arrhythmias constituted the test set: 10 AF and/or atrial flutter; 15 SVT; 16 VT; 10 ventricular flutter or VF; 5 sinus tachycardia; and 4 cases of AF concurrent with VF. Results from 60 patient cases indicate 57 (95%) of 60 success rate for A2CAD, validating its potential for implementation in future implantable devices.

Algorithms↗

Endocervical mucus pH is inversely related to serum androgen levels and waist to hip ratio.

OBJECTIVE: To determine whether an inter-relationship exists between endocervical mucus pH, serum androgen levels, and waist to hip (W:H) ratio. SETTING: Donor insemination clinic, University of Sheffield, Jessop Hospital, Sheffield, United Kingdom. PATIENTS: One hundred patients receiving donor insemination. INTERVENTIONS: Waist, hip, height, and weight measurements were recorded for 100 patients receiving donor insemination. At the onset of the LH surge when patients attended for their first insemination, a sample of endocervical mucus and blood was taken. The Insler score of the mucus was recorded and the pH was measured with multirange pH paper. Of the 100 patients studied, 10 cases had an endocervical mucus pH < 6 despite Insler scores of > 10. Serum T, DHEAS, and androstenedione levels were measured in the 10 patients with pH < 6 and in 26 patients selected at random from the 90 patients with pH > or = 6. RESULTS: The W:H ratio was significantly higher in the patients with pH < 6 than pH > or = 6. No significant difference was seen in body mass index between the latter groups. All serum androgen levels were significantly higher in the patients with pH < 6 than pH > or = 7. CONCLUSION: A potential link (serum androgen levels) between a powerful predictive factor of fertility (W:H ratio) and a potential mechanism of subfertility (low endocervical mucus pH) has been demonstrated. This observation warrants further detailed evaluation particularly as it has been shown that a low endocervical mucus pH may be corrected by simple inexpensive treatment.

Androgens↗

Ovarian hyperstimulation syndrome may be more likely if multiple pregnancy occurs following assisted conception.

Whereas modern assisted conception with such techniques as in vitro fertilisation now helps many subfertile couples to fulfill their ambition to have a child, it has not been without a price. The increased incidence of multiple pregnancies, with their attendant maternal and perinatal sequelae following assisted conception is well known, but perinatologists may be far less familiar with the Ovarian Hyperstimulation Syndrome (OHSS) which is the other major complication when controlled ovarian hyperstimulation is used during assisted conception treatment. Mild forms of OHSS are common and require no more than symptomatic treatment. Severe forms of OHSS are uncommon occurring in 0.6% to 14% of IVF cycles, but are nonetheless very important to identify as they may lead to thrombo-embolic disease, cardiorespiratory dysfunction, renal failure and even death [6]. This review considers whether OHSS may be related to multiple pregnancy by reviewing the available literature and local experience.

Female↗

Cyst formation.

Explore the source record for details and available documents.

Drug Administration Schedule↗

Pediatric low energy lithotripsy with the Lithostar.

Between November 1988 and July 1993, 238 renal stones and 208 ureteral stones were treated in 446 pediatric patients using 26 mobile and 2 fixed base Siemens Lithostar lithotriptors. The stones were treated by a group of 245 urologists using the modified Puigvert technique and the standard shock tube. The success rate for renal stones (asymptomatic fragments less than 4 mm.) was 76.6%, stone-free rate was 67.9%, retreatment rate was 14.1% and ancillary procedures were performed in 36.3%. The stone-free rate for ureteral stones was 91.1%, retreatment rate was 3.5% and ancillary procedures were performed in 17.7%. Anesthesia was required in 31% of the renal and 21% of the ureteral procedures. Sepsis in a 6-year-old child after treatment of a ureteral stone was the only major complication. Low energy lithotripsy with the Lithostar in our series of pediatric patients was safe and effective.

Adolescent↗