Search PubMedSearch

Biomedical subjects

J M Irving

Publications and source records attributed to J M Irving.

8 recordsLinked to original sources

Transcriptional analysis of the bovine herpesvirus 1 Cooper isolate. Temporal analysis and characterization of immediate-early, early, and late RNA.

Blot hybridization analysis of infected bovine herpesvirus 1 (BHV-1) cellular RNA isolated at various times post infection and after treatment with specific metabolic inhibitors was used to characterize transcription of the BHV-1 Cooper isolate. Synthesis of BHV-1 RNA was detected as early as 3 h post infection and reached a maximum at six to eight hours post infection. The most transcriptionally active area of the genome was between map units 0.110 to 0.195, within the HindIII I fragment. From the entire genome a total of 59 transcripts ranging in size from approximately 0.6 to 10 kilobases were characterized as belonging to one of three distinct classes. Using the protein synthesis inhibitor cycloheximide, three immediate-early transcripts were identified as originating from the internal inverted repeat region between map units 0.734 and 0.842, corresponding to the HindIII D fragment. Using phosphonoacetic acid to prevent virus DNA synthesis by inhibition of the BHV-1 DNA polymerase, 28 early transcripts were recognized. The remaining 28 transcripts, classified as late RNA, were detected without the use of metabolic inhibitors at 6 to 8 h post infection. Transcription of early and late RNA was not restricted to any specific area of the genome. Eighty percent of the transcripts from both the HindIII A fragment, between map units 0.381 to 0.537 within the unique long segment, and the HindIII K fragment, between map units 0.840 to 0.907 of the unique short segment, were designated as belonging to the early class.

Animals

GPASS.

Explore the source record for details and available documents.

Computer Systems

Evaluation of a portable measure of expired-air carbon monoxide.

There are a variety of independent methods of estimating smoking status; measurement of expired air carbon monoxide has proven to be reliable and convenient. This article describes a new, inexpensive, portable analyzer for measuring expired-air carbon monoxide --the Bedfont EC50. We have compared this analyzer with the standard instrument for measuring expired-air carbon monoxide in 138 normal subjects and found good correlation and agreement. The Bedfont was demonstrated to be better at identifying smoking status, and the relevance of this finding for classification of smokers and nonsmokers by fixed-threshold carbon monoxide levels is discussed. The features of the Bedfont EC50 are particularly appealing for field and clinical use.

Adult

Cloning and characterization of a genomic probe for malignant catarrhal fever virus.

A genomic probe specific for malignant catarrhal fever (MCF) virus was cloned by using purified viral DNA from MCF-virus strain WCll. Restriction endonuclease analysis of the purified viral DNA was used to identify the cloned viral genomic fragment. Dot blot hybridization by use of the genomic probe (pRP-5) indicated that the probe hybridized specifically with WCll-MCF virus, as well as with one other isolate of MCF-associated herpesvirus. Hybridization also was observed to a non-MCF virus strain of bovine herpesvirus.

Animals

Validation of a simple mechanical accelerometer (pedometer) for the estimation of walking activity.

A small (28 g) mechanical accelerometer has been tested by subjecting it to controlled bench tests consisting of repetitive vertical oscillations on two designs of test rig. The accelerometer's 3-digit display provided a cumulated score with a maximum of 99.9 units. This score was compared with an independent count of the imposed oscillations and found to be linear with time (r = 0.996) and reproducible on retest (coefficient of variation = +/- 1.5%). The sensitivity ranged from 6.2 to 7.4 units/10,000 oscillations. The response was related to the maximal applied acceleration (calculated from the amplitude and frequency of the oscillations on the assumption that they were sinusoidal) and independent of the amplitude and frequency used. The threshold maximal acceleration was less than 2 m s-2 and the response had reached a plateau at 4 m s-2. During field studies the accelerometer was firmly attached over the hip in a waistband where it responded to the vertical accelerations produced by walking. When compared with an independent count of footsteps from a heel-mounted resistance pad the accelerometer score (after calibration) was not significantly different. The mean difference was (0.29 +/- 0.67, S.D.) 10(3) "steps" in a younger group (n = 8, mean age 39 years) and (0.46 +/- 1.08, S.D.) 10(3) "steps" in an older group of women (n = 6, mean age 65 years). Scores of around 10 X 10(3) "steps" can be expected in a day in moderately active young subjects and 40 X 10(3) "steps" in a week in the elderly. Simultaneously recorded scores from both right and left hips wee not significantly different.(ABSTRACT TRUNCATED AT 250 WORDS)

Acceleration

An investigation of data entry methods with a personal computer.

The features of three methods of data entry were investigated and a trial of them was carried out using operators with differing amounts of keyboard experience. The first method was a simple system of character entry using a word processing package, and the second and third systems were written in a commercial data base language; one was designed to possess limited intelligence, the other moderate intelligence. The amount of time and computing expertise required to set up each method increased in parallel with its sophistication. The most sophisticated method offered theoretical advantages of reduced error rates and increased keying rates but these were not realized in practice. The limited intelligence method, in which data were entered into a screen image of the record form, was fastest overall and was most popular with all users. This method together with verification by dual keying will provide a convenient, rapid, and high fidelity method of data entry. The simplest method was found to be adequate for short forms but incurred high error rates with longer forms.

Computers

The use of microcomputers for data management in a large epidemiological survey.

A data management system designed around microcomputers and commercial software packages was employed for a large epidemiological study. Management involved the tracking of subjects through several stages of the study and the generation of subject listings, personalized letters of invitation, daily worklists for the field teams, and a checklist for the laboratories. These processes were controlled using a continually updated subject data base which in final form provided the core of the management system for the collected data. Data management presented major problems because of the volume of data which were received from several sources over a period of months. A key feature to emerge was the importance of an accurate serial number on all items for which a check digit was employed. The system had a short development time and was found to be inexpensive and flexible and to cope easily with the demands made of it.

Computers