Search PubMed⌕ Search

Biomedical subjects

J M Fitzpatrick

Publications and source records attributed to J M Fitzpatrick.

242 records · Page 14Linked to original sources

Application of proteomic strategies to the identification of urinary biomarkers for prostate cancer: a review.

In the post-genomic era, genes and proteins are now studied on a more comprehensive scale. Studying disease processes at only the genetic or transcriptomic level will give an incomplete amount of information. A proteomic approach potentially allows for a more global overview of how disease processes affect the proteins present in cells, tissues and organisms. The challenge arises in determining which proteins are affected in specific diseases and establishing which of these changes are unique to a particular disease. Existing and emerging proteomic technologies allow for high throughput analysis of proteins in a variety of sample types. Prostate cancer is a significant male health problem in the Western world. It is widely accepted that more specific prognostic and diagnostic markers of prostate cancer are urgently required. The present paper suggests that urine may be an attractive biofluid in which to pursue the identification of novel biomarkers of prostate cancer. This review introduces some proteomic techniques including mass spectrometry and the newer, quantitative proteomic strategies. It focuses on the potential application of these platforms to novel urinary biomarker identification in prostate malignancy. It also includes a synopsis of the current literature on urinary proteomics.

Biomarkers, Tumor↗

Retrospective registration of PET and MR brain images: an algorithm and its stereotactic validation.

OBJECTIVE: We present a validation study of an algorithm for retrospective registration of PET and MR brain images. MATERIALS AND METHODS: This algorithm involves two steps. In the first step, the two volumes are reformatted by aligning their interhemispheric fissure planes (midsagittal plane). In the second step, the corresponding planes parallel to the midsagittal plane are further aligned in the reformatted volumes to produce a 3D rigid body registration of the two original volumes. It is an efficient algorithm because both steps are performed in 2D spaces, and in each step only a small number of landmarks are required. A user-friendly system has been implemented to facilitate easy and fast processing of registration and reformatting of image volumes. The accuracy of this algorithm is validated using clinical scans of neurosurgical patients with a stereotaxic frame attached to their skull. The frame-based stereotaxic system provides an effective method for transforming image coordinates from different image volumes into a common coordinate system. This common coordinate system is used for assessing the spatial correspondence of each pixel in the registered image volumes. Validation using the stereotaxic image volumes enables objective estimation of retrospective registration accuracy. RESULTS: Analysis of 11 MR/PET image pairs indicates that our registration method not only is efficient but also provides adequate accuracy for most clinical evaluation of PET studies. CONCLUSION: We have implemented and validated an efficient algorithm for retrospective registration of PET and MR brain images.

Adult↗

Effect of geometrical distortion correction in MR on image registration accuracy.

In this article we investigate the effect of geometrical distortion correction in MR images on the accuracy of the registration of X-ray CT and MR head images for both a fiducial marker (extrinsic point) method and a surface-matching technique. We use CT and T2-weighted MR image volumes acquired from seven patients who underwent craniotomies in a stereotactic neurosurgical clinical trial. Each patient had four external markers attached to transcutaneous posts screwed into the outer table of the skull. The MR images are corrected for static field inhomogeneity by using an image rectification technique and corrected for scale distortion (gradient magnitude uncertainty) by using an attached stereotactic frame as an object of known shape and size. We define target registration error (TRE) as the distance between corresponding marker positions after registration and transformation. The accuracy of the fiducial marker method is determined by using each combination of three markers to estimate the transformation and the remaining marker to calculate registration error. Surface-based registration is accomplished by fitting MR contours corresponding to the CSF-dura interface to CT contours derived from the inner surface of the skull. The mean point-based TRE using three noncollinear fiducials improved 34%-from 1.15 to 0.76 mm-after correcting for both static field inhomogeneity and scale distortion. The mean surface-based TRE improved 46%-from 2.20 to 1.19 mm. Correction of geometrical distortion in MR images can significantly improve the accuracy of point-based and surface-based registration of CT and MR head images. Distortion correction can be important in clinical situations such as stereotactic and functional neurosurgery where 1 to 2 mm accuracy is required.

Head↗

Comparison and evaluation of retrospective intermodality brain image registration techniques.

PURPOSE: The primary objective of this study is to perform a blinded evaluation of a group of retrospective image registration techniques using as a gold standard a prospective, marker-based registration method. To ensure blindedness, all retrospective registrations were performed by participants who had no knowledge of the gold standard results until after their results had been submitted. A secondary goal of the project is to evaluate the importance of correcting geometrical distortion in MR images by comparing the retrospective registration error in the rectified images, i.e., those that have had the distortion correction applied, with that of the same images before rectification. METHOD: Image volumes of three modalities (CT, MR, and PET) were obtained from patients undergoing neurosurgery at Vanderbilt University Medical Center on whom bone-implanted fiducial markers were mounted. These volumes had all traces of the markers removed and were provided via the Internet to project collaborators outside Vanderbilt, who then performed retrospective registrations on the volumes, calculating transformations from CT to MR and/ or from PET to MR. These investigators communicated their transformations again via the Internet to Vanderbilt, where the accuracy of each registration was evaluated. In this evaluation, the accuracy is measured at multiple volumes of interest (VOIs), i.e., areas in the brain that would commonly be areas of neurological interest. A VOI is defined in the MR image and its centroid c is determined. Then, the prospective registration is used to obtain the corresponding point c' in CT or PET. To this point, the retrospective registration is then applied, producing c" in MR. Statistics are gathered on the target registration error (TRE), which is the distance between the original point c and its corresponding point c". RESULTS: This article presents statistics on the TRE calculated for each registration technique in this study and provides a brief description of each technique and an estimate of both preparation and execution time needed to perform the registration. CONCLUSION: Our results indicate that retrospective techniques have the potential to produce satisfactory results much of the time, but that visual inspection is necessary to guard against large errors.

Brain↗

Correcting scaling errors in tomographic images using a nine degree of freedom registration algorithm.

PURPOSE: Clinical imaging systems, especially MR scanners, frequently have errors of a few percent in their voxel dimensions. We evaluate a nine degree of freedom registration algorithm that maximizes mutual information for determining scaling errors. We evaluate it by registering MR and CT images for each of five patients (patient scaling) and by registering MR images of a phantom to a computer model of the phantom (phantom scaling). METHOD: Each scaling method was validated using bone-implanted markers localized in the patient images and also intraoperatively. The root mean square residual in the alignment of the fiducial markers [fiducial registration error (FRE)] was determined without scale correction, with patient scaling, and with phantom scaling. RESULTS: Each scaling method significantly reduced the average FRE (p < 0.05) for MR to CT registration and for MR to physical space registration, indicating that voxel scaling errors were reduced. The greater reduction in scaling errors was achieved using the phantom scaling method. CONCLUSION: We have demonstrated that a nine degree of freedom registration algorithm that maximizes mutual information can significantly reduce scaling errors in MR.

Algorithms↗

Patients' experiences of varicose vein and arthroscopy day surgery.

A small-scale telephone survey of day surgery patients' (n = 30) experience of pain, nausea and vomiting, wound healing and fatigue during the 7 days following discharge and their views of the service is described. Respondents who had undergone either varicose vein stripping (n = 15) or arthroscopy (n = 15) were interviewed using a semi-structured interview schedule. The findings indicated that most respondents expressed satisfaction with their recovery despite some evidence of postoperative morbidity. The majority of the sample indicated that they had received adequate information to enable them to cope at home and qualified nurses on the day unit were identified as a primary source of information. Following discharge, GPs or the day unit were key points of contact. The findings of this study, together with previous research, highlight important areas for further action by health professionals if this service is to be delivered effectively and efficiently.

Adolescent↗

Serum myoglobin does not predict cardiac allograft rejection.

Noninvasive studies are useful, but limited, in detecting rejection among cardiac allograft recipients. Because an elevated serum myoglobin level is a sensitive indicator of necrosis in acute myocardial infarction, we postulated that myoglobin levels might correlate with the presence, absence, or degree of rejection. Therefore we prospectively measured serum myoglobin levels at the time of endomyocardial biopsy in 45 heart transplant recipients and correlated these levels with biopsy scores (grade 0 through grade 4). There was no significant difference in mean myoglobin levels among patients with grade 0 biopsy scores and those with grade 1 through grade 4 scores. Serial myoglobin levels and endomyocardial biopsy specimens were obtained in five patients during a 4- to 9-week period; no significant directional change in myoglobin levels appeared to correlate with changes in endomyocardial biopsy score. In addition, a normal myoglobin level did not exclude, nor did an elevated level confirm, any grade of rejection. We conclude that neither the absolute level nor a directional change in serum myoglobin is useful in identifying rejection among heart transplant recipients.

Biomarkers↗