Search PubMed⌕ Search

Biomedical subjects

J M Doyle

Publications and source records attributed to J M Doyle.

At least 19 recordsLinked to original sources

Hybrid quantum processors: molecular ensembles as quantum memory for solid state circuits.

We investigate a hybrid quantum circuit where ensembles of cold polar molecules serve as long-lived quantum memories and optical interfaces for solid state quantum processors. The quantum memory realized by collective spin states (ensemble qubit) is coupled to a high-Q stripline cavity via microwave Raman processes. We show that, for convenient trap-surface distances of a few microm, strong coupling between the cavity and ensemble qubit can be achieved. We discuss basic quantum information protocols, including a swap from the cavity photon bus to the molecular quantum memory, and a deterministic two qubit gate. Finally, we investigate coherence properties of molecular ensemble quantum bits.

Journal Article↗

High-flux beam source for cold, slow atoms or molecules.

We demonstrate and characterize a high-flux beam source for cold, slow atoms or molecules. The desired species is vaporized using laser ablation, then cooled by thermalization in a cryogenic cell of buffer gas. The beam is formed by particles exiting a hole in the buffer gas cell. We characterize the properties of the beam (flux, forward velocity, temperature) for both an atom (Na) and a molecule (PbO) under varying buffer gas density, and discuss conditions for optimizing these beam parameters. Our source compares favorably to existing techniques of beam formation, for a variety of applications.

Journal Article↗

Can the radiologist accurately predict the adequacy of sampling when performing ultrasound-guided core biopsy of BI-RADS category 4 and 5 lesions detected on screening mammography?

AIM: To investigate in mammography screening the correlation between the confidence level of the radiologist, in sampling BI-RADS assessment category 4 and 5 lesions using a single ultrasound-guided 14-gauge needle core biopsy, and the final histological diagnosis. METHODS: In a prospective study, 389 consecutive ultrasound-guided 14-gauge needle core biopsies were performed on 131 BI-RADS assessment category 4 and 5 breast lesions in 126 women. On average, 3 passes were made through each lesion; for each pass, the radiologist rated confidence in adequacy of sampling at <50%, 50% to 90% or >90%. This was compared with the final histological diagnosis. RESULTS: The radiologist was >90% confident in 293 biopsies; diagnostic results were confirmed at histology in 283 (97%). In 70 biopsies the radiologist was 50% to 90% confident; diagnostic results were confirmed in 60 (86%). Of 26 samples where confidence was <50%, 13 were diagnostic (50%) (p<0.0001). CONCLUSION: If, at the time of ultrasound-guided needle core biopsy of BI-RADS assessment category 4 and 5 breast lesions, the radiologist is >90% confident that the lesion has been adequately sampled, a single pass is usually sufficient for diagnosis.

Attitude of Health Personnel↗

Zeeman effect in CaF(2Pi(3/2)).

The Zeeman effect in the excited A 2Pi(3/2) state of CaF is measured and analyzed over a wide range of magnetic fields. It is found that the splitting of the Zeeman levels is largely determined by the coupling between different rotational states and there are no low-field seeking states in the J=3/2 manifold of Zeeman levels at high magnetic fields. A model of the Zeeman spectrum based on the ligand-field theory of CaF is shown to be accurate in the interval of magnetic fields 0-5 Tesla. This demonstrates that the magnetic moment of the CaF(A 2Pi(3/2)) molecule is effectively determined by the spin angular momentum of a single electron and the orbital motion of the valence electron around the Ca2+ core. An analysis of the Zeeman spectrum as a function of the molecular rotational constant indicates that 2Pi(3/2) molecules should have significant rotational constants (at least as large as twice the rotational constant of CaF) to be amenable to magnetic trapping in high fields.

Journal Article↗

Hyperactivity caused by a nitric oxide synthase inhibitor is countered by ultra-wideband pulses.

Potential action of ultra-wideband (UWB) electromagnetic field pulses on effects of N(G)-nitro- L-arginine methyl ester (L-NAME), an inhibitor of nitric oxide synthase (NOS), on nociception and locomotor activity was investigated in CF-1 mice. Animals were injected IP with saline or 50 mg/kg L-NAME and exposed for 30 min to no pulses (sham exposure) or UWB pulses with electric field parameters of 102+/-1 kV/m peak amplitude, 0.90+/-0.05 ns duration, and 160+/-5 ps rise time (mean+/-S.D.) at 600/s. Animals were tested for thermal nociceptive responses on a 50 degrees C surface and for spontaneous locomotor activity for 5 min. L-NAME by itself increased mean first-response (paw lift, shake, or lick; jump) and back-paw-lick response latencies and mean locomotor activity. Exposure to UWB pulses reduced the L-NAME-induced increase in back-paw-lick latency by 22%, but this change was not statistically significant. The L-NAME-induced hyperactivity was not present after UWB exposure. Reduction and cancellation of effects of L-NAME suggest activation of opposing mechanism(s) by the UWB pulses, possibly including increase of nitric oxide production by NOS. The action, or actions, of UWB pulses appears to be more effective on locomotor activity than on thermal nociception in CF-1 mice.

Analysis of Variance↗

Frequency of micronuclei in the blood and bone marrow cells of mice exposed to ultra-wideband electromagnetic radiation.

PURPOSE: To investigate the extent of genetic damage in the peripheral blood and bone marrow cells of mice exposed to ultra-wideband electromagnetic radiation (UWBR). MATERIALS AND METHODS: CF-1 male mice were exposed to UWBR for 15 min at an estimated whole-body average specific absorption rate of 37 mW x kg(-1). Groups of untreated control and positive control mice injected with mitomycin C were also included in the study. After various treatments, half of the mice were killed at 18 h, and the other half at 24 h. Peripheral blood and bone marrow smears were examined to determine the extent of genotoxicity, as assessed by the presence of micronuclei (MN) in polychromatic erythrocytes (PCE). RESULTS: The percentages of PCE and the incidence of MN per 2000 PCE in both tissues in mice killed at 18 h were similar to the frequencies observed in mice terminated at 24 h. There were no significant differences in the percentage of PCE between control and the mice with or without UWBR exposure; the group mean values (+/- standard deviation) were in the range of 3.1+/-0.14 to 3.2+/-0.23 in peripheral blood, and 49.0+/-3.56 to 52.3+/-4.02 in bone marrow. The mean incidence of MN per 2000 PCE in control and in mice with or without UWBR exposure ranged from 7.7+/-2.00 to 9.7+/-2.54 in peripheral blood and 7.4+/-2.32 to 10.0+/-3.27 in bone marrow. Pairwise comparison of the data did not reveal statistically significant differences between the control and mice with or without UWBR exposure groups (excluding positive controls). CONCLUSION: Under the experimental conditions tested, there was no evidence for excess genotoxicity in peripheral blood or bone marrow cells of mice exposed to UWBR.

Animals↗

Ultra-wideband electromagnetic pulses and morphine-induced changes in nociception and activity in mice.

Mice were exposed to ultra-wideband (UWB) electromagnetic pulses averaging 99-105 kV/m peak amplitude, 0.97-1.03 ns duration, and 155-174 ps rise time, after intraperitoneal administration of saline or morphine sulfate. They were then tested for thermal nociception on a 50 degrees C surface and for spontaneous locomotor activity and its time profile over 5 min. Analysis of results showed no effect of UWB exposure on nociception and activity measures in CF-1 mice after 15-, 30-, or 45-min exposure to pulses at 600/s or after 30-min exposure to UWB pulses at 60/s. Similarly, no effect was seen in C57BL/6 mice after 30-min exposure to pulses at 60/s or 600/s. Although trends in morphine-modified measures seen with UWB pulse repetition frequency could be expected because of increased levels of low-frequency energy, no significant change was seen in normal or morphine-modified nociception or activity after UWB exposure. This indicated lack of effect of the UWB pulses used in these experiments on nervous system components, including endogenous opioids, involved in these behaviors.

Analgesics, Opioid↗

Novel electrolyte for the analysis of cations in low explosive residue by capillary electrophoresis.

A novel electrolyte has been developed for the effective separation by capillary electrophoresis of cations detected in low explosive residue. This electrolyte, with a pH of 4.4, employs 17.5 mM alpha-hydroxyisobutyric acid (HIBA) as the complexing agent, 6 mM imidazole as the ultraviolet visualization agent, 4 mM 18-crown-6 ether as a modifier to enhance the selectivity of the inorganic cations, and 5% (v/v) acetonitrile as an organic additive. Studies which assessed the value of the addition of 18-crown-6 and acetonitrile demonstrated conclusively that both were required in order to achieve unambiguous baseline separation of ammonium, potassium and monomethylammonium ions. The major advantages of the use of this electrolyte are a total run time of less than 7 min and symmetrical peak shapes. Validation on a series of preblast and postblast explosives materials determined that this procedure is reliable and robust.

Acetonitriles↗

Regional brain heating during microwave exposure (2.06 GHz), warm-water immersion, environmental heating and exercise.

Nonuniform heating may result from microwave (MW) irradiation of tissues and is therefore important to investigate in terms of health and safety issues. Hypothalamic (Thyp), cortical (Tctx), tympanic (Tty), and rectal (Tre) temperatures were measured in rats exposed in the far field, k-polarization (i.e., head pointed toward the transmitter horn and E-field in vertical direction) to two power densities of 2.06 GHz irradiation. The high-power density (HPM) was 1700 mW/cm2 [specific absorption rate (SAR): hypothalamus 1224 W/kg; cortex 493 W/kg]; the low-power density (LPM) was 170 mW/cm2 (SAR: hypothalamus 122.4 W/kg; cortex 49.3 W/kg). The increase (rate-of-rise, in degrees C/s) in Thyp was significantly greater than those in Tctx or Tre when rats were exposed to HPM. LPM produced more homogeneous heating. Quantitatively similar results were observed whether rats were implanted with probes in two brain sites or a single probe in one or the other of the two sites. The qualitative difference between regional brain heating was maintained during unrestrained exposure to HPM in the h-polarization (i.e., body parallel to magnetic field). To compare the temperature changes during MW irradiation with those produced by other modalities of heating, rats were immersed in warm water (44 degrees C, WWI); exposed to a warm ambient environment (50 degrees C, WSED); or exercised on a treadmill (17 m/min 8% grade) in a warm ambient environment (35 degrees C, WEX). WWI produced uniform heating in the regions measured. Similar rates-of-rise occurred among regions following WSED or WEX, thus maintaining the pre-existing gradient between Thyp and Tctx These data indicate that HPM produced a 2-2.5-fold difference in the rate-of-heating within brain regions that were separated by only a few millimeters. In contrast, more homogeneous heating was recorded during LPM or nonmicrowave modalities of heating.

Animals↗

Amino acid concentrations in hypothalamic and caudate nuclei during microwave-induced thermal stress: analysis by microdialysis.

Exposure to radiofrequency radiation (RFR) may produce thermal responses. Extracellular amino acid concentrations in the hypothalamus (Hyp) and caudate nucleus (CN) were measured by using in vivo microdialysis before and during exposure to RFR. Under urethane anesthetic, each rat was implanted stereotaxically with a nonmetallic microdialysis probe and temperature probe guides and then placed in the exposure chamber. The rat laid on its right side with its head and neck placed directly under the wave guide. Temperature probes were placed in the left brain, right brain, face (subcutaneously), left tympanum, and rectum. Each microdialysis sample was collected over a 20 min period. The microdialysis probe was perfused for 2 h before the rat was exposed to 5.02 GHz radiation (10 microseconds pulse width, 1000 pulses/s). The right and left sides of the brain were maintained at approximately 41.2 and 41.7 degrees C, respectively, throughout a 40 min exposure period. Initially when the brain was being heated to these temperatures, the time-averaged specific absorption rates (SARs) for the right and left sides of the brain were 29 and 40 W/kg, respectively. Concentrations of aspartic acid, glutamic acid, serine, glutamine, and glycine in dialysate were determined by using high-pressure liquid chromatography with electrochemical detection. In the Hyp and CN, the concentrations of aspartic acid, serine, and glycine increased significantly during RFR exposure (P < .05). These results indicate that RFR-induced thermal stress produces a general change in the amino acid concentrations that is not restricted to thermoregulatory centers. Changes in the concentrations of glutamic acid (Hyp, P = .16; CN, P = .34) and glutamine (Hyp, P = .13; CN, P = .10) were not statistically significant. Altered amino acid concentrations may reveal which brain regions are susceptible to damage in response to RFR-induced thermal stress.

Amino Acids↗

Hereditary breast cancer.

BACKGROUND: Hereditary breast cancer is thought to account for less than 10 per cent of all breast cancers. Recently there have been significant advances in understanding of the genetics, with the sequencing of the genes BRCA1 and BRCA2 which are associated with hereditary breast cancer. METHODS AND RESULTS: Current understanding of hereditary breast cancer and its impact on the management of women with this disease is reviewed. CONCLUSION: Problems in accurate testing for breast cancer-associated genes remain. No reliable simple test exists because of the large number of mutations present in these genes. The implications of different mutations remain poorly understood. Guidelines for the management of carriers of the breast cancer-associated genes remain controversial.

Breast Neoplasms↗

Pulse dexamethasone does not impair growth and body composition of very low birth weight infants.

OBJECTIVE: Evaluation of repeated pulses of dexamethasone (PDEX), given to improve cardiopulmonary outcome, on growth of very low birth weight (VLBW, < 1500 g) infants. METHODS: In this prospective, double-blind, randomized clinical trial, VLBW infants mechanically ventilated at 1 week of age received intravenous PDEX or saline placebo (P) for 3 days, every 10 days, until no supplemental oxygen or ventilation was required or 36 weeks postmenstrual age (PMA). Weight gain, fluid intake, caloric intake, and serum glucose were monitored throughout the study. Nutritional assessment at 36 weeks PMA consisted of weight, length, head circumference, skinfold thickness measures, body composition by total body electrical conductance, and bone mineral content (BMC) by single beam photon absorptiometry. RESULTS: 37 PDEX and 31 P infants survived at least 36 days and completed the protocol. Average daily weight gain, fluid intake and caloric intake were not different between groups. The pattern of weight gain (g/kg/day, mean +/- SD) was different: PDEX infants showed significant growth delay during (3.0 +/- 11.4) and immediately after (7.8 +/- 8.7) each pulse, with subsequent growth acceleration (18.3 +/- 8.2) until the next steroid pulse. In contrast, growth rate of P infants was constant (12.6 +/- 3.7) (p = 0.04). Hyperglycemia requiring insulin therapy occurred only in the PDEX group (10/37). The catch-up growth noted between pulses in the PDEX group was explained only in part by insulin therapy. At 36 weeks PMA, there were no differences between groups in body size, composition, or BMC. CONCLUSION: PDEX negatively affected glucose metabolism and growth patterns during and immediately after drug exposure. However, assessment near term gestational age showed similar body composition and size in both groups.

Body Composition↗