Search PubMed⌕ Search

Biomedical subjects

J M Bogaard

Publications and source records attributed to J M Bogaard.

At least 37 records · Page 2Linked to original sources

Effect of a nasal dilatator on nasal patency during normal and forced nasal breathing.

A nasal dilatator contains two elastic strips, which provide the dilatator with a spring action. The aimed function of the nasal dilatator is to slightly open the nares and hereby facilitate nasal breathing. The aim of this study was to evaluate the effect of a nasal dilatator by measuring nasal airway resistance during normal breathing and nasal forced expiratory and inspiratory flows and volumes with and without use of the nasal dilatator. Nasal resistance was measured with a whole body plethysmograph; maximal expiratory and inspiratory flow-volume curves were obtained with a pneumotachometer. These measurements were performed in ten healthy volunteers. No significant difference was found between nasal resistance with and without the nasal dilatator. However, values for forced inspiratory volume in 1 s (FIV 1) with the nasal dilatator, proved to be significantly higher (p=0.045,paired t-test) than values obtained without the nasal dilatator; mean improvement was 0.26 L (sd = 0.36). No significant improvement in peak inspiratory flow (PIF) was found, as was the case for the other flows and volumes. It is concluded that the nasal dilatator causes no appreciable improvement of nasal patency during normal breathing. In view of the fact that FIV 1 values increased significantly, we believe that the nasal dilatator prevents collapse of the external nares during forced inspiration. A beneficial effect during exercise when ventilation is increased is however doubtful because in that situation most volunteers switch to oronasal breathing already at submaximal exercise.

Adult↗

Time to peak tidal expiratory flow and the neuromuscular control of expiration.

The ratio of the time needed to reach peak tidal expiratory flow (tPTEF) and the duration of expiration (tE) is used to detect airflow obstruction in young children. tPTEF is decreased in patients with asthma, but knowledge about the physiological determinants of this parameter is scarce. This study examined the relationship between tPTEF and postinspiratory activities of inspiratory muscles and evaluated the effects of changing sensory information from the lung. Airflow patterns and electromyographic (EMG) activity of inspiratory muscles were recorded in seven spontaneously breathing, anaesthetized cats. The trachea was cannulated and, as a result, the larynx and upper airways were bypassed. Changes in postinspiratory muscle activity were induced by changing afferent sensory nerve information (by cooling the vagus nerves, by administration of histamine and by additional application of continuous positive airway pressure (CPAP)). Durations of postinspiratory activities of the diaphragm and intercostal muscles (characterized by their time constants tau diaphr and tau interc) correlated strongly with tPTEF (r=0.85 and 0.77, respectively). Tau diaphr, tau interc and tPTEF were significantly increased during cooling of the vagus nerves (4-8 degrees C) compared with values at 22 and 37 degrees C (p<0.05). Conversely, administration of histamine and CPAP caused significant decreases in tau diaphr, tau interc and tPTEF, which were absent during cooling of the vagus nerves. In conclusion, the time needed to reach peak tidal expiratory flow is highly influenced by the activities of inspiratory muscles during the early phase of expiration which, in turn, depend on the activities of vagal receptors in the lung.

Animals↗

Uvulopalatopharyngoplasty for the obstructive sleep apnoea syndrome: value of polysomnography, Mueller manoeuvre and cephalometry in predicting surgical outcome.

Sixty consecutive patients with the obstructive sleep apnoea syndrome (53 men and seven women) were analysed by questionnaire, polysomnography, röntgenographic cephalometry and the Mueller manoeuvre before and 6 months after uvulopalatopharyngoplasty (UPPP), to assess the surgical outcome and the prognostic value of preoperative evaluation. Seventy-three per cent of patients reported improvement of snoring and 55% reported improvement of excessive daytime sleepiness. Thirty-five per cent showed a decrease of at least 50% in the desaturation index, and 13% had a postoperative desaturation index below 5. Although the improvement of desaturation parameters was marked in some patients, the overall change was not significant. Neither the Body Mass Index (BMI), nor any of the cephalometric variables were significantly correlated to surgical outcome. Increased difference in collapsibility between the soft palate and the base of the tongue showed a close to significant relation with the improvement of desaturation index. High desaturation index, low mean saturation and deep lowest saturation were found to be slightly predictive of improvement in nocturnal desaturation. In a multivariate analysis however no significant predictors could be identified. It is concluded that UPPP is effective in reducing snoring and daytime sleepiness over a 6-month follow-up period, but that the overall improvement in nocturnal desaturation is limited and difficult to predict. Further research is needed to evaluate the long-term efficacy of UPPP.

Body Mass Index↗

Elastic work of breathing during continuous positive airway pressure in intubated patients with chronic obstructive pulmonary disease (theoretical analysis and experimental validation).

BACKGROUND: Continuous positive airway pressure (CPAP) is known to decrease inspiratory work of breathing in patients with chronic obstructive pulmonary disease (COPD). This effect is primarily attributed to a reduction in inspiratory elastic work of breathing (Wi,el) related to a decrease in intrinsic positive end-expiratory pressure (PEEP). METHODS: The aim of this study is to design a model for computation of Wi,el on the basis of respiratory mechanics in patients with COPD, at various intrinsic PEEP- and CPAP-levels. The model was used to estimate the optimal CPAP-level with respect to the intrinsic PEEP-level in terms of reduction of Wi,el. Calculations of the decrease in Wi,el due to CPAP obtained with the model were compared to changes in Wi,el and total work of breathing (Wi,tot) determined from respiratory measurements in patients with COPD. RESULTS: Model calculations revealed that Wi,el was minimal whenever a CPAP-level equal to the intrinsic PEEP-level was applied. When a CPAP-level exceeding the intrinsic PEEP-level was applied, the reduction in Wi,el was less. Comparing these results to the respiratory measurements, a similar pattern in reduction of Wi,el and Wi,tot was established, although absolute values of the differences were smaller in the experimental data. CONCLUSION: This study indicates that in order to reduce Wi,el in patients with COPD, intrinsic PEEP should be measured and the CPAP-level adjusted to the intrinsic PEEP-level.

Aged↗

Wave-speed-determined flow limitation at peak flow in normal and asthmatic subjects.

The purpose of this study was to examine whether peak expiratory flow is determined by the wave-speed flow-limiting mechanism. We examined 17 healthy subjects and 11 subjects with stable asthma, the latter treated with inhaled bronchodilators and corticosteroids. We used an esophageal balloon and a Pitot-static probe positioned at five locations between the right lower lobe and midtrachea to obtain dynamic area-transmural pressure (A-Ptm) curves as described (O. F. Pedersen, B. Thiessen, and S. Lyager. J. Appl. Physiol. 52: 357-369, 1982). From these curves we obtained cross-sectional area (A) and airway compliance (Caw = dA/dPtm) at PEF, calculated flow at wave speed (Vws = A[A/(Caw*rho)0.5], where rho is density) and speed index is (SI = V/Vws). In 13 of 15 healthy and in 4 of 10 asthmatic subjects, who could produce satisfactory curves, SI at PEF was > 0.9 at one or more measured positions. Alveolar pressure continued to increase after PEF was achieved, suggesting flow limitation somewhere in the airway in all of these subjects. We conclude that wave speed is reached in central airways at PEF in most subjects, but it cannot be excluded that wave speed is also reached in more peripheral airways.

Adult↗

Ventilator-CPAP with the Siemens Servo 900C compared with continuous flow-CPAP in intubated patients: effect on work of breathing.

The effects of continuous positive airway pressure (CPAP) provided by the Siemens Servo 900C ventilator were compared with a continuous flow system (CF-CPAP) in patients weaning from the ventilator. Thirteen patients were studied using both systems at a CPAP level of 0.5 kPa. Additional work of breathing (Wapp) and derived variables were determined in relation to the minute volumes of the patients. The Wapp imposed by the ventilator exceeded the Wapp of CF-CPAP in all patients. The difference in Wapp between ventilator- and CF-CPAP was greater at higher ventilatory needs. The increments in Wapp imposed by the ventilator were positively correlated with the actual end-expiratory pressures (EEP). The EEP increasingly exceeded the preset CPAP level of the ventilator at higher minute volumes. An inspiratory threshold due to a gradient between EEP and preset CPAP greatly increased the Wapp imposed by the ventilator. As this threshold was attributed to the resistance of the PEEP device of the ventilator, it indicates that the additional work related to the expiratory value should be taken into account when the Siemens Servo 900C ventilator is used for weaning purposes.

Adult↗

Dead space and slope indices from the expiratory carbon dioxide tension-volume curve.

The slope of phase 3 and three noninvasively determined dead space estimates derived from the expiratory carbon dioxide tension (PCO2) versus volume curve, including the Bohr dead space (VD,Bohr), the Fowler dead space (VD,Fowler) and pre-interface expirate (PIE), were investigated in 28 healthy control subjects, 12 asthma and 29 emphysema patients (20 severely obstructed and nine moderately obstructed) with the aim to establish diagnostic value. Because breath volume and frequency are closely related to CO2 elimination, the recording procedures included varying breath volumes in all subjects during self-chosen/natural breathing frequency, and fixed frequencies of 10, 15 and 20 breaths x min(-1) with varying breath volumes only in the healthy controls. From the relationships of the variables with tidal volume (VT), the values at 1 L were estimated to compare the groups. The slopes of phase 3 and VD,Bohr at 1 L VT showed the most significant difference between controls and patients with asthma or emphysema, compared to the other two dead space estimates, and were related to the degree of airways obstruction. Discrimination between no-emphysema (asthma and controls) and emphysema patients was possible on the basis of a plot of intercept and slope of the relationship between VD,Bohr and VT. A combination of both the slope of phase 3 and VD,Bohr of a breath of 1 L was equally discriminating. The influence of fixed frequencies in the controls did not change the results. The conclusion is that Bohr dead space in relation to tidal volume seems to have diagnostic properties separating patients with asthma from patients with emphysema with the same degree of airways obstruction. Equally discriminating was a combination of both phase 3 and Bohr dead space of a breath of 1 L. The different pathophysiological mechanisms in asthma and emphysema leading to airways obstruction are probably responsible for these results.

Adult↗

Controlled expiration in mechanically-ventilated patients with chronic obstructive pulmonary disease (COPD).

In patients with severe chronic obstructive pulmonary disease (COPD), lung emptying may be affected by flow limitation. We tested the hypothesis that the airway compression leading to flow limitation can be counteracted by controlling the expiratory flow. The effects of an external resistor on lung emptying were studied in six patients with COPD, who were mechanically ventilated whilst sedated and paralysed. Respiratory mechanics were obtained during ventilatory support with and without the resistor. Airway compression was assessed using the interruptor method. For the study, a turbulent resistor was applied with the highest resistance level that did not increase the end-expiratory lung volume. At this resistance level, external positive end-expiratory pressure (PEEP) was generated in all patients. As total PEEP levels remained unchanged at both settings during the controlled expiration, the levels of intrinsic PEEP were significantly decreased from 0.96+/-0.30 to 0.53+/-0.19 kPa (mean+/-SD). Comparison of the expiratory flow-volume curves at both settings revealed that, during the controlled expiration, the flows were significantly decreased during the first 40% of the expired volume and significantly increased during the last 60%. As the end-expiratory lung volumes remained unchanged during both settings, these increments in flow indicated a decrease in effective resistance. Airway compression was observed during unimpeded expirations in all patients using the interruptor method. During the application of the resistor, airway compression was no longer detectable. In patients with chronic obstructive pulmonary disease receiving ventilatory support, the application of an external resistor could decrease effective expiratory resistance by counteracting airway compression, without increments in end-expiratory lung volume.

Aged↗

Clinical evaluation of diminished early expiratory flow (DEEF) ventilation in mechanically ventilated COPD patients.

OBJECTIVE: To evaluate the cardiopulmonary effects, especially the end-expiratory lung volume (EEV) and ventilation inhomogeneity during diminished early expiratory flow ventilation (DEEF), which resembles pursed-lips breathing, with the conventional intermittent positive pressure ventilation (IPPV) in postoperative mechanically ventilated patients with chronic obstructive pulmonary disease (COPD). DESIGN: A prospective study measuring cardiopulmonary parameters during IPPV, DEEF, and positive end-expiratory pressure (PEEP) as a control mode. In the PEEP mode, PEEP values were chosen such that the mean airway pressure during a breath cycle was equal to that during the DEEF mode, which was higher than the conventional IPPV mode. SETTING: Surgical intensive care unit of a university hospital. PATIENTS: 20 postoperative mechanically ventilated COPD patients who were optimally pretreated and had normal blood oxygenation. INTERVENTIONS: Measurements were started in the IPPV (IPPV1) mode, continued in a randomized order with DEEF or PEEP, and completed with a second IPPV (IPPV2) mode, with 1 h equilibration time in each mode before each measurement. MEASUREMENTS AND RESULTS: A multi-breath indicator gas wash-out test was used to calculate the EEV and ventilation inhomogeneity. There was a 9% increase (p < 0.05) in the mean EEV during both the DEEF and PEEP mode compared to IPPV. No significant changes in the ventilation inhomogeneity and deadspace fractions or the hemodynamic parameters were found during the different ventilatory modes. CONCLUSIONS: There was no improvement in pulmonary and hemodynamic parameters during the DEEF mode in comparison to the IPPV mode. The small increase in EEV during DEEF was probably caused by the slightly higher mean expiratory pressures as in the PEEP mode. However, this had no effect on the hemodynamic parameters. As we could not observe any improvement with the DEEF ventilation in our optimally pretreated postoperative COPD patients, we do not advise applying this therapy in this group of patients, since this mode of ventilation may cause barotrauma if not monitored adequately.

Aged↗

Assessment of accuracy and applicability of a portable electronic diary card spirometer for asthma treatment.

A pocked-sized turbine flowmeter and spirometer device, integrated with an electronic diary card (EDC-spirometer, Micro Medical, U.K.), was tested with a mechanical calibrator, in an outpatient clinic and in the home situation. A screen pneumotachometer was used as flow and volume reference. Ten devices were tested; interdevice variability was small with a mean variation coefficient of 1.1% for both forced expiratory volume in 1 s (FEV1) and peak expiratory flow (PEF) (SD 0.5 and 0.4, respectively) for eight settings of the calibrator. Mean difference from reference was -0.13 l (SD 0.04) for FEV1 (range 0.38-3.16) and 0.09 l s-1 (SD 0.09) for PEF (range 4.2-11.7). No significant deviation from linearity was present. Results obtained in the outpatient clinic confirmed the accuracy of FEV1 and PEF data obtained with the calibrator. However, linear regression analysis showed a mean underestimation of 0.45 l (SD of estimate 0.29) for forced vital capacity over the whole measurement range, probably due to a restricted integration time. In 10 optimally-treated chronic obstructive pulmonary disease patients in a family practice, PEF measurements were done in the home situation, both with the EDC spirometer and a mini-Wright peak flow meter. No significant differences in the diurnal variation of PEF were found. The PEF data from the mini-Wright meter were corrected for earlier reported flow-dependent systematic deviations. In the home situation, patients preferred the EDC spirometer. It is concluded that this device is applicable in the follow-up and treatment of asthma at home.

Adolescent↗

Upper airway patency and nocturnal desaturation in habitual snoring and obstructive sleep apnea: pathogenesis of sleep-related breathing disorders.

Sixty patients, 53 men and 7 women, referred for excessive snoring or suspected sleep apnea syndrome were analyzed by polysomnography, Mueller maneuver, cephalometric roentgenography, and pulmonary function testing, to evaluate the contribution of static and dynamic upper airway obstruction in the pathogenesis of sleep-related breathing disorders and OSAS. Desaturation index and maximal desaturation were used in the analysis as indicators of severity of sleep-related breathing disorders. Body Mass Index, increased collapsibility at the base of the tongue by the Mueller maneuver, increased distance between hyoid and mandibular plane, and increased soft palate diameters by cephalometry as well as a decreased peak inspiratory flow by pulmonary function testing were found to be related to increased oxygen desaturation parameters. In a multivariate analysis the significant obstruction parameters could explain only 37% of the variability of maximum desaturation and 31% of the variability of desaturation index, 63 and 69%, respectively, must therefore be explained by other mechanisms. We conclude that instability of respiratory and muscular control, possibly enhanced by sleep-phase-related changes, is more important in the pathogenesis of sleep-related breathing disorders than pure anatomic narrowing of the airway.

Adult↗

Breathing pattern awake and asleep in myotonic dystrophy.

Because myotonic dystrophy patients show marked irregularities of breathing both awake and asleep, variables related to breathing pattern under both conditions were measured in 11 patients, together with pulmonary function indices, ventilatory CO2 response and maximal mouth pressures. The aim of the study was to detect and explain a possible interrelationship between daytime and nocturnal irregularity. Awake, patients demonstrated significantly more variability in tidal volume and respiratory cycle time than controls. Asleep, periodic breathing occurred during up to 100% of the time spent in light sleep, but not during deep sleep. A strong correlation was found with age (r = 0.73, p = 0.01). No relationship was found between disturbed breathing awake and asleep. There was a tendency for increased variability of tidal volume awake in cases with a decreased ventilatory CO2 response (p = 0.1). The results indicate that different mechanisms may be involved in daytime and nocturnal irregularity. It is hypothesized that brain stem integrative functions may be impaired in myotonic dystrophy.

Adolescent↗

Tidal breathing analysis as a measure of airway obstruction in children three years of age and older.

This study was designed to evaluate the value and applicability of tidal breathing pattern analysis to assess airflow obstruction in young children. The time needed to reach maximal tidal expiratory flow (TME) divided by total expiratory time (TE) was measured in 228 healthy children 3 to 11 yr of age, 64 patients with asthma, and 12 children with cystic fibrosis. In 70 patients both TME/TE and forced maximal expiratory flow volume (MEFV) parameters were measured. The mean TME/TE in healthy subjects was 43.0 +/- 7.6%. The within-subject reproducibility was high (repeatability index, 5.3%). In the asthmatic patients the mean TME/TE was significantly lower (30.0 +/- 8.2%, p < 0.001), and it increased to 36.5 +/- 7.9% after bronchodilation (n = 44, p < 0.001). The TME/TE level of the subgroup of patients with asthma and FEV1/FVC > or = 0.80 was lower when compared with age-matched normal subjects (30.9 +/- 8.5, p < 0.0001), but it was in a higher range when compared with asthmatics with FEV1/FVC < 0.80 (25.9 +/- 7.9, p < 0.001). In the cystic fibrosis group the mean TME/TE was 27.4 +/- 10.7% without a significant change after bronchodilation. TME/TE correlated significantly with MEFV parameters. Tidal breathing analysis proved easy to perform in children older than 3 yr of age. The TME/TE ratio may be a reliable and simple indicator for airway obstruction.

Airway Resistance↗

Improvement of tidal breathing pattern analysis in children with asthma by on-line automatic data processing.

The time taken to achieve peak tidal expiratory flow as a proportion of total expiratory time (t PTEF/t E) during tidal breathing (TB) is used as a parameter of airway obstruction in children with asthma. Curve selection bias is one of the most important limitations to the method. This study evaluates three curve selection methods, including a computer program, which on-line selects and analyses TB curves (Masterscreen Paediatric; Jaeger, Germany). TB analysis was performed in 26 children (aged 4-7 yrs) with asthma, before and after methacholine provocation and after subsequent bronchodilatation. Levels and stability of TB parameters derived from computer-selected, unselected and unbiased eye-selected curves were compared. t PTEF/t E ratios of the computer-selected curves agreed well with the unbiased eye-selected curves (limits of agreement -4.8 and +5.8%), but were significantly different from the ratios of unselected curves. Computer-derived t PTEF/t E ratios had the highest level of stability: the reliability coefficient of baseline measurements was 0.96 for computer selection, 0.84 for eye selection and 0.87 for no selection (reliability index = 1 at maximal stability). Tidal volume, respiratory rate, inspiratory and expiratory time were also assessed accurately by the computer program. The mean t PTEF/t E ratio (computer selection) dropped after methacholine provocation (from 30 +/- 9 to 22 +/- 9% at provocative dose at which forced expiratory volume in one second had dropped > or = 20% from baseline (FEV1-PD20 level), p < 0.001) and was restored after bronchodilation (30 +/- 6%; p < 0.001). We conclude that on-line computer analysis is preferable to no selection and to by-eye selection. The use of the program avoids curve selection bias and enhances the applicability of tidal breathing analysis as a measure of airflow obstruction in young children.

Asthma↗

Early and late allergic reaction in the nose assessed by whole body plethysmography.

Physiological changes during late phase nasal responses after allergen challenge are difficult to establish and different criteria are used for the definition of a positive late phase nasal reaction. The objective of this study was to assess the value of whole body plethysmography in detecting changes in nasal airway resistance after allergen challenge and to suggest criteria for the definition of early and late phase nasal reactions. Nasal challenge with allergen was performed in 15 allergic patients. Nasal resistance was followed until 10 h after allergen challenge and on a control day using whole body plethysmography. The mean percentage changes in the inspiratory nasal resistance during the early phase period (0.25-2 h) and the late phase period (4-10 h) were significantly higher on the allergen challenge day than on the control day (p=0.001 and p=0.01, respectively). The mean percentage change in the inspiratory nasal resistance during the early and late phase period on the control day plus 2 times the standard deviation served as cut-off point for a positive reaction. Using this definition, all patients had early reactions and 7 of the 15 patients (47%) also had late reactions. We conclude that whole body plethysmography is a useful, noninvasive method for the measurement of the physiological changes in the nose following allergen challenge.

Adult↗

Physiological and morphological determinants of maximal expiratory flow in chronic obstructive lung disease.

Maximal expiratory flow in chronic obstructive pulmonary disease (COPD) could be reduced by three different mechanisms; loss of lung elastic recoil, decreased airway conductance upstream of flow-limiting segments; and increased collapsibility of airways. We hypothesized that decreased upstream conductance would be related to inflammation and thickening of the airway walls, increased collapsibility would be related to decreased airway cartilage volume, and decreased collapsibility to inflammation and thickening of the airway walls. Lung tissue was obtained from 72 patients with different degrees of COPD, who were operated upon for a solitary peripheral lung lesion. Maximal flow-static recoil (MFSR) plots to estimate upstream resistance and airway collapsibility were derived in 59 patients from preoperatively measured maximal expiratory flow-volume and pressure-volume curves. In 341 transversely cut airway sections, airway size, airway wall dimensions and inflammatory changes were measured. Airflow obstruction correlated with lung elastic recoil and the MFSR estimate of airway conductance but not to airway collapsibility or to the amount of airway cartilage. The upstream conductance decreased as the inner wall became thicker. Airway collapsibility did not correlate with the amount of airway cartilage, inflammation, or airway wall thickness. We conclude that the maximal flow-static recoil model does not adequately reflect the collapsibility of the flow-limiting segment.

Adult↗

Effects of fluticasone propionate on methacholine dose-response curves in nonsmoking atopic asthmatics.

Methacholine is frequently used to determine bronchial hyperresponsiveness (BHR) and to generate dose-response curves. These curves are characterized by a threshold (provocative concentration of methacholine producing a 20% fall in forced expiratory volume in one second (PC20) = sensitivity), slope (reactivity) and maximal response (plateau). We investigated the efficacy of 12 weeks of treatment with 1,000 microg fluticasone propionate in a double-blind, placebo-controlled study in 33 atopic asthmatics. The outcome measures used were the influence on BHR and the different indices of the methacholine dose-response (MDR) curve. After 2 weeks run-in, baseline lung function data were obtained and a MDR curve was measured with doubling concentrations of the methacholine from 0.03 to 256 mg x mL(-1). MDR curves were repeated after 6 and 12 weeks. A recently developed, sigmoid cumulative Gaussian distribution function was fitted to the data. Although sensitivity was obtained by linear interpolation of two successive log2 concentrations, reactivity, plateau and the effective concentration at 50% of the plateau value (EC50) were obtained as best fit parameters. In the fluticasone group, significant changes occurred after 6 weeks with respect to means of PC20 (an increase of 3.4 doubling doses), plateau value fall in forced expiratory volume in one second (FEV1) (from 58% at randomization to 41% at 6 weeks) and baseline FEV1 (from 3.46 to 3.75 L) in contrast to the placebo group. Stabilization occurred after 12 weeks. Changes for reactivity were less marked, whereas changes in log, EC50 were not significantly different between the groups. We conclude that fluticasone is very effective in decreasing the maximal airway narrowing response and in increasing PC20. However, it is likely that part of this increase is related to the decrease of the plateau of maximal response.

Administration, Topical↗

Is delayed introduction of inhaled corticosteroids harmful in patients with obstructive airways disease (asthma and COPD)? The Dutch CNSLD Study Group. The Dutch Chronic Nonspecific Lung Disease Study Groups.

BACKGROUND: The institution of inhaled corticosteroids is generally advocated for effective treatment of patients with asthma. It is yet unknown what is the best time to start inhaled corticosteroid therapy and especially whether delayed introduction is harmful. PHASE 1: In a previous study in patients with asthma and COPD, we found that 2.5 years of treatment with a beta 2-agonist plus inhaled corticosteroid (BA + CS) was more effective in improving the FEV1 and the provocative concentration of histamine causing a 20% reduction in FEV1 (PC20) than treatment with a beta 2-agonist plus anticholinergic (BA + AC) or placebo (BA + PL). PHASE 2: We extended this study with 6 months to investigate whether delayed introduction of inhaled CS therapy (800 micrograms beclomethasone dipropionate) in the groups previously not treated with inhaled CS (BA +/- AC) could also improve FEV1 and PC20 to the same degree. A distinction was made between patients with predominantly asthma (high baseline reversibility, delta FEV1 > or = 9% of predicted), and predominantly COPD (low baseline reversibility, delta FEV1 < 9% of predicted). RESULTS: Improvement of FEV1 percent predicted by inhaled CS was comparable both in the asthmatics between phase 1 (13.8% predicted) and phase 2 (8.5% predicted; p = 0.31) as well as in the patients with COPD (2.5% and 1.5% predicted, respectively). PC20, however, increased significantly more in the asthmatics in phase 1 (1.77 doubling concentration [DC]) than in phase 2 (0.79 DC; p = 0.03). Improvement of PC20 in the patients with COPD was not significantly higher in phase 1 (0.74 DC) than in phase 2 (0.00 DC; p = 0.19). CONCLUSIONS: Our study indicates that although delayed introduction of inhaled CS in asthmatics leads to similar improvements in FEV1, improvements in PC20 are significantly less. These findings in patients with longer-existing asthma concur with other findings in newly detected asthma. We suggest that institution of inhaled CS therapy should not be postponed in asthmatics with documented airways obstruction and reversibility.

Administration, Inhalation↗