[Heart heterotopic homotransplantation in rats: study of the initial stages of rejection and influence of preservation].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to J Leandri.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A new endoprosthesis designed for surgical intubation of neoplastic strictures of the proximal biliary tract has been developed. The technical aspects of intubation by this endoprosthesis are discussed, and the results in the first 25 patients are given. The results suggest that this device was well tolerated. Mortality and morbidity related to the endoprosthesis were low in comparison to the results given in the literature for intrahepatic cholangioenteric anastomosis. The authors conclude that this procedure could favorably replace intrahepatic cholangioenteric anastomosis as currently used for selected cases of malignant biliary stricture.
The first 5 years durability study on a substantial number of Mitroflow pericardial valves makes the substance of the present report. One hundred eighty-eight valves were implanted on 166 patients before December 1985: 149 patients were discharged and are recalled annually. Follow up is 99% complete. In October 1988, mean follow up was 3.5 years (3-5.5). Total patients times years is 582. Sixty-two percent of the patients are asymptomatic, 58% in sinus rhythm. Forty-seven percent do not receive any anticoagulant therapy. The linearized rates of thromboembolism (1.2% per patient-year) and endocarditis (0.17 per patient-yr) is minimal. Seven patients only had valve dysfunction requiring explantation (1.2% per patient-yr). At 5 years, freedom of structural deterioration is 95.2% +/- 2.1. Single cusp tear at a stent post is the most frequent lesion (86%) as calcifications are observed in three only (major in two, microscopical in one). Histology does not permit to ascertain whether the tear is due to tissue fatigue or abrasion. Moderate microscopic architectural disruption of the valvular tissue is observed. Composite indices of all valve mortality and morbidity show at 5 years a 89.7% +/- 2.9 freedom of events. These data, associated to the high mechanical and optimal clinical characteristics of the valve, published previously, confirm the satisfactory performances of the valve at 5 years.
Cannulae for paracorporeal ventricular assist devices have been clinically shown to be limiting factors in optimal circulatory support. A new inflow cannula has been manufactured according to an original silicone rubber molding process, permitting a hemocompatible inner surface. The cannula is 200 mm in length, with a 10 mm internal diameter. The wall is 3 mm thick and reinforced by a stainless steel spiral spring embedded in the silicone. An external ring permits adequate interface between the cannula and the endocardial surface of the atrium. A compliant external segment on the inflow cannula, free of any spiral spring, allows adjustment of vacuum to optimal values, thus avoiding inflow obstruction. The cannula has been tested during 1 to 5 days of left ventricular bypass in calves (n = 15). A Symbion AVAD, Utah 85 VAD, or Centrimed pumps were used. Adequate heparinization was maintained throughout. Paracorporeal flow was 0.045 L min-1 kg-1. In vivo evaluation was made by hemodynamic studies and the incidence of thromboembolism. The cardiac cavities, cannulae, and peripheral vessels were carefully searched for thrombi and emboli at autopsy. The atrium, the interface between atrium and silicone cannula, and the cannula itself were found free of any deposit. This aspect differed from that observed previously with available PU or PVC cannulae.
The aim of this study was to detect biologic factors in the structural deterioration of bioprosthetic heart valves. Prostheses were removed from patients after 4-8 years of implantation and submitted to biochemical and morphologic assays. Successive staining of biologic sections revealed colocalization of lipids and glycosaminoglycans underneath calcifications in the disintegrated extracellular matrix. On biochemical assays, the amidolysis of synthetic peptide substrates indicated thrombin, plasmin, and tissue plasminogen activator activities in the nonhemocompatible leaflets; 0.15 mol NaCl, 0.05 mol Tris, and 5 mmol CaCl2 extracts from the prostheses cleaved the peptide substrate for collagenase and lysed gelatin gels. Polyacrylamide gel electrophoresis in sodium dodecyl sulfate disclosed the presence of low molecular mass polypeptides in extracts of the deteriorated prostheses. The detection of plasmin and collagenolytic enzyme(s), and the known broad proteolytic activity of plasmin, may point to the role of activation of the fibrinolytic system in the proteolytic degradation of bioprosthetic valves.
The palliative therapy of stenoses of the biliary tract is a difficult choice. Because percutaneous or endoscopic drainage methods are fraught with complications, an endoprosthesis for surgical intubation of the biliary tract has been developed. Thirty patients were treated by this method. After choledochotomy, the endoprosthesis is positioned surgically above the sphincter of Oddi, thereby avoiding ascending cholangitis. Twenty-nine patients (13 with gallbladder cancer, 11 with cholangiocarcinomas, 5 with metastases) presented with neoplastic compression, and one patient had an early postoperative stricture with loss of substance after right hepatectomy for hepatic metastases. The operative mortality was 3.3% (one pulmonary complication). Resolution of jaundice was obtained in all but two patients, and pruritus always resolved. The mean survival time for the patients with cholangiocarcinoma was 12.2 months and 6.33 months for those with gallbladder cancer. Indices of satisfaction (Bismuth's method) were 71% (gallbladder cancer), 93.5% (hilar cholangiocarcinoma), and 92% (metastatic compressions). This new type of surgical endoprosthesis is an alternative in the palliative treatment of neoplastic hilar compression because it is well tolerated, has a low rate of operative mortality or morbidity, and affords an acceptable quality of life for the patients.
In radiation therapy of tumors, several techniques are used to prevent injury of the intestinal loops. Their purpose is to drive the intestine out of the external beam. Understanding the disadvantages they present, a temporary prosthesis which effectively protects the small bowel, and is easy to remove, has been developed. The device is a 600 to 1,000 ml, silicone rubber, expandable balloon. When implanted in the pelvis or retroperitoneal cavity, and filled, this balloon displaces the intestinal loops out of the pelvic irradiation field. It may remain either filled or empty between each irradiation session. Due to its particular elliptical shape, once empty, the balloon can be removed through a 3 cm incision under local or peridural anesthesia at the completion of radiotherapy. Eleven patients with recurrent (8) or primary (3) cancer have been implanted. The protective effect has been evaluated on successive biologic tests, performed during treatment. No problem related to the prosthesis, no alteration of the biologic tests, nor bowel injury have been observed after several months follow-up. This device is suitable for preventing intestinal complications during therapy, allowing a higher dose of radiations in some cases.