Search PubMedSearch

Biomedical subjects

J Leandri

Publications and source records attributed to J Leandri.

15 recordsLinked to original sources

Mode of failure of the Mitroflow pericardial valve.

A consecutive series of 188 Mitroflow pericardial bioprostheses were inserted in 166 patients between 1st January 1983 and 31st December 1985. Twenty-two valves had to be removed from 16 patients after a mean follow up period of 78 months (range 58-92 months) for aortic, 73 months (65-79 months) for mitral and 78 months (48-103 months) for double valve replacements. All but one reoperations for primary tissue failure were carried out as elective surgical procedures. The most important cause of failure was collagen degeneration, seen in all explanted valves. The areas of degeneration were the major sites of origin of calcification, which was seen in 11 valves (50%). Ten valves (45%) showed features suggestive of lipid infiltration, extensive fatty acid deposition being identified in one and a typical atheromatous reaction in another. In contrast to the Ionescu-Shiley valve, the mode of failure was tear originating at the top of the commissure, associated with major structural changes in the tissue. Excessive pannus ingrowth was observed in 11 valves (50%). The universal presence of tissue degeneration in the glutaraldehyde treated pericardial leaflets of the Mitroflow bioprostheses explanted and examined in this study questions the adequacy of the methods employed in the harvesting and/or processing and/or preservation of this valve. We have, therefore, discontinued using the Mitroflow bioprosthesis. However, the slow deterioration of the Mitroflow bioprosthesis permits elective reoperation; preventive removal of functioning valves is therefore not indicated.

Adult

In vitro endothelialization of carbon-coated Dacron vascular grafts.

Physical vapour deposition is used to coat vascular prostheses with pyrolytic carbon. This coating may facilitate the development of an endothelial monolayer in grafts implanted in laboratory animals. This in vitro study compared the adherence and growth of cultured porcine aortic endothelial cells (EC) seeded in vitro on carbon-coated Dacron, to uncoated prostheses. The cells were incubated at 5 x 10(4) cells/cm2. Progress was monitored at different times (TO + 2 hours, D 1, D 4, D 8) by microscopic observation, when cell counts were made; and by scanning electronic microscopy (SEM) to evaluate morphological EC-graft interactions. Cell adherence was independent of the carbon coating but cellular growth occurred only on carbon-coated Dacron. The SEM observations showed both the shape of the adherent cells, which were rounded on uncoated Dacron and extensively spread on carbon-coated prostheses, and the morphology of the carbon coating.

Blood Vessel Prosthesis

Enhanced O2 transportation during cardiopulmonary bypass in piglets by the use of inositol hexaphosphate loaded red blood cells.

A continuous lysing and resealing of erythrocytes permitted internalization of inositol hexaphosphate (IHP), a strong allosteric effector of Hb, leading to significant rightward shifts of the HbO2 dissociation curve. Twelve piglets were put on cardiopulmonary bypass (CPB) with the heart beating, cooled to 25 degrees C then rewarmed to 37 degrees C before weaning off CPB. AoP, LV pressure, PAP, and cardiac output (CO) were monitored. Blood samples were taken before CPB, at 25 degrees C, at 30 degrees C, at 37 degrees C and after CPB for assessment of blood gases, arterio-venous difference in O2 content, lactates, P50 (partial pressure of O2 at 50% Hb saturation), and ionogram. Control group I included five pigs where the CPB circuit was primed with Ringer's lactate solution and porcine blood. In group II (n = 5), priming was done with Ringer's lactate solution and IHP loaded erythrocytes. P50 was significantly higher during CPB than before surgery in group II (20%), but not in group I (1%). There was a significant increase in VO2 in group II (6.02 ml/min) compared to group I (4.03 ml/min) (p less than 0.05) after CPB. Hemodynamics improved after CPB in group II (mean AoP 42 mmHg and syst LVP 70 mmHg) compared to group I (AoP 25 mmHg and syst LVP 22.5 mmHg). These preliminary results show that O2 transportation at the end of CPB is enhanced and myocardial function is improved in piglets with the use of IHP erythrocytes.

Animals

[Conflicting xenograft. Role of preoperative total lymphoid irradiation].

This study deals with an experimental model of discordant cardiac xenograft between 24 donor lambs of the Préalpes race and 24 recipient Camborough pigs divided up into 4 groups: I control (6) without immunosuppressive treatment; II (5) with pharmacological immunosuppression (IP); III (13) with PI and total lymphoid irradiation (TLI) and immediate graft, divided up into IIIa (5) with high-rate (HR) TLI and IIIb with low-rate (LR) TLI; IV (4) with a two-week lapse between TLI and grafting. The best graft survival rate (GSR) is obtained either after delayed LR-TLI or after LR-TLI without delay. This study seems to be the first one demonstrating that for discordant xenogenic grafts, TLI associated to PI with cyclosporin A (Cy A) significantly prolongs the survival of the graft (30 times).

Animals

[Experimental study of arterial microanastomoses under tension in the Wistar rat. Morphologic and histologic effects].

An experimental study was performed to evaluate the effects of tension on microsurgical anastomoses. A variable length of the common carotid artery in Wistar rats was resected to give variable degrees of tension and the artery was reanastomosed microsurgically. 42 Wistar rats were divided into 7 groups of 6 rats each according to the relative length resected. Repaired arteries were then compared histologically and functionally with the artery of the contralateral side, submitted to simple section followed by microsurgical anastomosis. Significant histological changes occurred when the length of the resected segment was greater than 13.33% of the vessel's total length. These changes included subendothelial hyperplasia, medial necrosis and thrombosis. The results of this study lead us to conclude that small degrees of tension (less than 13.33% of total vessel length in this study), have no significant effects on patency of microanastomoses. Greater tension results in changes in the laminar flow through vessels that can adversely effect patency. There are also significant histological changes that may have detrimental effects in the long term.

Anastomosis, Surgical

[New surgical procedure for the protection of the small intestine before postoperative pelvic irradiation].

A prosthesis was designed to protect the intestinal loop from external beam radiation therapy when post-operative radiation is indicated. It is a silicone inflatable balloon, which, when implanted displaces the intestinal loops out of the pelvic irradiation field. The prosthesis can be deflated between each course of irradiation, without surgery. The device has been used in 8 patients: 6 patients with recurrent pelvic tumor (2 rectal cancers, 1 anal cancer, 1 cancer of the endometrium, 1 cervical carcinoma, 1 ovarian carcinoma), 2 patients with primary tumor (1 malignant paraganglioma, 1 cervical carcinoma). Radiotherapy was administered by means of high power appliances. After radiotherapy, the prosthesis was deflated, then removed through a 3 cm incision under local or peridural anesthesia. The tolerance of the small intestine to the radiation therapy has been satisfactory in each case with no bowel injury due to radiation. Therefore, this simple device might be useful to prevent bowel injury during postoperative radiation in the treatment of abdominal and retroperitoneal tumor masses.

Combined Modality Therapy

Fetal breathing and adaptation to maternal hemorrhage in the sheep.

The effect of maternal hemorrhage in chronic preparations was studied on fetal lambs in the last month of gestation. Fourteen to 20 per cent of maternal blood was estimated to have been removed within 30 minutes, which resulted in a drop of 30 per cent of mean maternal arterial pressure. A fetal bradycardia started 28 +/- 13 minutes after the beginning of maternal hemorrhage. It lasted 30 +/- 15 minutes and was concomitant with a rise in fetal arterial pressure. It was followed by a long-lasting fetal tachycardia of 130 +/- 38 minutes and was corrected only by reinfusion of blood to the mother. The fetal blood gases demonstrated a mild asphyxia with a persistent metabolic acidemia until reinfusion of blood to the mother. Maternal and fetal plasma cortisol levels rose significantly at the end of the hemorrhage. Tracheal fluid flow did not change. Fetal breathing recorded 20 hours before and 24 hours after the experiment did not show consistent changes, but during fetal bradycardia there was no fetal breathing. Recent clinical investigations in this field have been made in the human fetus to estimate standards of fetal well being. These peculiar animal experiments do not show any significant improvement by recording fetal breathing over the recording of prelabor fetal heart rate.

Adaptation, Physiological

Palliative treatment of bile duct tumoral compression by an endoprosthesis: clinical results.

The palliative therapy of stenoses of the biliary tract is a difficult choice. Because percutaneous or endoscopic drainage methods are fraught with complications, an endoprosthesis for surgical intubation of the biliary tract has been developed. Thirty patients were treated by this method. After choledochotomy, the endoprosthesis is positioned surgically above the sphincter of Oddi, thereby avoiding ascending cholangitis. Twenty-nine patients (13 with gallbladder cancer, 11 with cholangiocarcinomas, 5 with metastases) presented with neoplastic compression, and one patient had an early postoperative stricture with loss of substance after right hepatectomy for hepatic metastases. The operative mortality was 3.3% (one pulmonary complication). Resolution of jaundice was obtained in all but two patients, and pruritus always resolved. The mean survival time for the patients with cholangiocarcinoma was 12.2 months and 6.33 months for those with gallbladder cancer. Indices of satisfaction (Bismuth's method) were 71% (gallbladder cancer), 93.5% (hilar cholangiocarcinoma), and 92% (metastatic compressions). This new type of surgical endoprosthesis is an alternative in the palliative treatment of neoplastic hilar compression because it is well tolerated, has a low rate of operative mortality or morbidity, and affords an acceptable quality of life for the patients.

Adenoma, Bile Duct

Protection of the small intestine against irradiation by means of a removable prosthesis.

In radiation therapy of tumors, several techniques are used to prevent injury of the intestinal loops. Their purpose is to drive the intestine out of the external beam. Understanding the disadvantages they present, a temporary prosthesis which effectively protects the small bowel, and is easy to remove, has been developed. The device is a 600 to 1,000 ml, silicone rubber, expandable balloon. When implanted in the pelvis or retroperitoneal cavity, and filled, this balloon displaces the intestinal loops out of the pelvic irradiation field. It may remain either filled or empty between each irradiation session. Due to its particular elliptical shape, once empty, the balloon can be removed through a 3 cm incision under local or peridural anesthesia at the completion of radiotherapy. Eleven patients with recurrent (8) or primary (3) cancer have been implanted. The protective effect has been evaluated on successive biologic tests, performed during treatment. No problem related to the prosthesis, no alteration of the biologic tests, nor bowel injury have been observed after several months follow-up. This device is suitable for preventing intestinal complications during therapy, allowing a higher dose of radiations in some cases.

Adult