Bioimpedance: a novel method for the determination of extravascular lung water.

Extravascular lung water (EVLW) can be measured using the double indicator dilution technique (DD). However, because this method is highly invasive and complicated, its clinical used has been limited. In theory, changes in thoracic conductivity, or bioimpedance (BI), can reflect changes in EVLW. However, past studies were unable to directly quantitate changes in EVLW since the contribution of dynamic variables such as ventricular volumes, hematocrit (HCT), and EVLW to this impedance signal could not be discerned. Recent studies have shown that a thermodilution pulmonary artery catheter mounted with a fast response thermistor accurately measures right ventricular end-diastolic volume (RVEDV). With changes in the RVEDV and HCT known, the contribution of EVLW to the bioimpedance signal may be isolated and used to more directly measure changes in EVLW. This hypothesis was tested by creating acute sepsis in seven pigs by infusion of Pseudomonas aeruginosa. Changes in EVLW from baseline were measured using DD at 30 min and at 1, 2, and 4 hr and compared with the change in EVLW computed from a mathematical model comprising the measured changes in BI, RVEDV, and HCT at the same time points. Changes in EVLW using DD and BI were significantly correlated over the length of the study (r = 0.85, P less than 0.01). In early sepsis (30 min), BI overestimated EVLW when compared with DD (P less than 0.05). However, at 1, 2, and 4 hr there was no significant difference between the two methods. In conclusion, the use of bioimpedance and a volumetric catheter may provide a relatively simple and reliable method for continuously monitoring changes in EVLW in the intensive care setting.

Animals↗

Thermodilution right ventricular ejection fraction. Catheter positioning effects.

Right ventricular (RV) ejection fractions have been difficult to estimate clinically. It has been demonstrated recently that RV ejection fractions can be calculated by thermodilution techniques using a rapid response thermistor and computer. This method critically depends on adequate mixing of the thermal bolus and sensing of the rapid response thermistor. This study examined the effects of the thermistor position within the pulmonary artery and injectate site within the right atrium on RV thermodilution ejection fraction measurements. Ten pigs were instrumented with a RV thermodilution catheter in the pulmonary artery, an injectate catheter in the right atrium, an atrial-pacing electrode, and a systemic arterial catheter. The RV ejection fractions were determined using thermodilution in two ways: (1) with incremental increases in pulmonic valve to thermistor distance, and (2) with incremental increases in injectate port to tricuspid valve. These measurements were obtained at a paced rate of 107 +/- 1 beats per minute (bpm) and then repeated with pacing-induced tachycardia (140 bpm). The highest RV ejection fraction with the lowest coefficient of variation was with the thermistor 2 cm from the pulmonic valve (50 +/- 2 percent), with a significant decline from this value at 10 cm (42 +/- 4 percent, p less than 0.05). This reduction in RV ejection fraction values with increased pulmonic valve to thermistor distance became more pronounced with tachycardia where a significant decline in RV ejection fraction occurred at 4 cm from the valve when compared with 0 cm (38 +/- 6 percent vs 47 +/- 3 percent, respectively, p less than 0.05). There was no significant change in RV ejection fraction at any injectate port to tricuspid valve distance at the lower heart rate. With tachycardia, however, a significant decline in RV ejection fraction occurred with the injectate port located 7 cm from the tricuspid valve (p less than 0.05). These results demonstrate that RV ejection fractions can be reliably obtained using thermodilution. Positioning of the thermodilution catheter is an important consideration for obtaining optimal RV ejection fraction measurements. Care should be taken to position the catheter with the thermistor a minimal distance from the pulmonic valve and the injectate port within the central body of the right atrium.

Animals↗

Hemodynamic effects of leukotriene (LT) D4 and a LTD4 receptor antagonist in the pig.

Vascular bed reactivity to exogenous LTD4 and blockade of these responses by a selective LTD4 receptor antagonist, SK&F 104353, were studied. Yorkshire pigs (N = 13; 25.8 +/- 1.4 kg) were anesthetized with isoflurane, and monitored for cardiac output (CO), mean pulmonary artery pressure (MPAP), pulmonary capillary wedge pressure (PCWP), right ventricular stroke work (RVSW), mean arterial pressure (MAP), renal artery blood flow (RABF), pulmonary vasculature resistance (PVR), renal vascular resistance (RVR), and systemic vascular resistance (SVR). LTD4 (0.03, 0.1, 0.3, 1, 3 and 10.0 micrograms/kg) was given intravenously. The MPAP, MAP, and RABF were recorded at baseline and for 20 min after the injection of LTD4. SK&F 104353 was infused (3 mg/kg/h, i.v.) and the dose-response to LTD4 was repeated. LTD4 induced changes in the MPAP, PCWP, MAP, and RABF. SK&F 104353 attenuated LTD4 induced changes in the MPAP, PVR, RABF and RVSW. MPAP was increased 123 +/- 24% and 115 +/- 10%, respectively, in pigs given 3.0 and 10 micrograms/kg doses, and increased to only 36 +/- 9% at a 10 micrograms/kg dose of LTD4 in animals pretreated with SK&F 104353 (P less than 0.05). MPAP was not increased at the 3.0 micrograms/kg dose, and increased to only 36 +/- 9% at a 10 micrograms/kg dose of LTD4 in animals pretreated with SK&F 104353 (P less than 0.05). These changes were paralleled by a reduction in PVR. RABF was decreased 76 +/- 5% and 83 +/- 7%, respectively, at the 3.0 and 10 micrograms/kg dose of LTD4.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗