Search PubMed⌕ Search

Biomedical subjects

J L Milton

Publications and source records attributed to J L Milton.

20 records · Page 2Linked to original sources

The effect of intercondylar notchplasty on the normal canine stifle.

This study evaluated the effect of notchplasty (enlargement of the intercondylar fossa) in stable and unstable canine stifles. Bilateral notchplasty and unilateral cranial cruciate ligament (CrCL) transection were performed in 6 dogs. Exercise, consisting of walking 1.5 miles three times a week, began 1 month after surgery and continued until euthanasia 6 months after surgery. Evaluation methods included orthopedic examination, serial radiographs, thin section radiography, histopathology, and gross pathology. Notchplasty in the stable stifle did not cause lameness beyond 3 weeks, joint instability, or degenerative joint disease. In the stable stifle, smooth resurfacing of the notchplasty site with fibrous and osseous tissue occurred. Stifles with notchplasty and CrCL transection exhibited persistent lameness, instability, and degenerative joint disease. In CrCL deficient stifles osteophytes formed within the notchplasty site, resulting in a rough surface. Our observations indicated significant refilling in notchplasties of both stable and unstable stifles (P < .05). However, the intercondylar fossa (ICF) width 6 months after notchplasty was significantly smaller in unstable stifles compared with stable stifles (P < .05) indicating that greater refilling of the notchplasties occurred in the unstable stifles. In clinical cases, notchplasty should be larger than the desired final result to accomodate the partial refilling that occurs even in stable stifles.

Animals↗

The effects of implant orientation, canal fill, and implant fit on femoral strain patterns and implant stability during catastrophic testing of a canine cementless femoral prosthesis.

Cementless femoral stems were placed into 12 normal greyhound femora. The implanted femora were divided into three groups by stem orientation and implant size and loaded in axial compression at a rate of 25 newtons (N) per second until failure. Rosette strain gauges were used to measure femoral principal strains at 500 N, 1,000 N, 1,500 N, and at maximum load. During maximum load, varus orientation of the femoral stem had significantly higher tensile hoop strains in the proximomedial cortex, whereas neutral orientation had higher tensile hoop strains along the cranial cortex. Femoral fractures occurred in these areas of peak tensile strain. There was no difference in maximum load between groups, therefore varus orientation did not predispose to fracture. Maximizing canal fill and implant fit increased implant stability.

Animals↗