Acquired C1-inhibitor deficiency associated with a lupus-like anticoagulant activity.

A patient with two attacks of glottis angioedema in a 15-day period without any apparent stimulus was studied. The complement profile of the patient revealed depletion of C4, C2, C1 inhibitor (C1INH) and C1q, with normal values of C3. Patient's offspring had a normal complement profile. Cytofluorographic analysis of the peripheral blood cells showed a marked increase of B cells. In the clotting study, a circulating lupus-like anticoagulant activity (LLA) was detected with a noticeable decrease of prothrombin time. Hepatosplenomegaly was confirmed by abdominal echography and CAT. From the liver biopsy it was concluded to be a lymphoproliferative process compatible with germinal center lymphoma. It is suggested that the neoplasm is probably the origin of the LLA and the cause of C1 activation, producing the biochemical defect of C1INH and the clinical symptoms of angioedema.

Aged↗

[Ionic dialysance to control the dose of dialysis. One year experience].

The Diascan equipment (Hospal) measures ionic dialysane which it derives the K and the Kt. If we divide the Kt obtained with Diascan between the Kt/V obtained by a simplified formula, it result a value of V for every patient. Entering this V in the Diascan software we can obtain a Kt/V (Diascan Kt/V), similar in theory to the simplified Kt/V. In the year 2002 we have controlled the delivered dialysis in our unit with the Diascan Kt/V. The aim of the present study was to study the agreement between de Diascan Kt/V and the Lowrie Kt/V. During the year 2002, 63 patients have been dialyzed in monitors with Diascan equipment. We calculated the V of each patient by dividing the Kt Diascan between the Lowrie Kt/V in the same dialysis session. The mea of the two consecutive measurements was considered the V value. Throughout the year 2002, 7 agreement studies were realized. The inter-method variability was assessed by the relative difference (absolute difference Diascan Kt/V-Lowrie Kt/V, divided by the average of both tests). A good agreement was considered when the relative difference was equal or lower than 10%. In the 7 agreement studies realized, the mean of the relative difference oscilled between 5.2 and 6.6%, and the percentage of patients with a relative difference equal or lower than 10% oscilled between 83 and 91%. During a month, the Diascan Kt/V was controlled in all dialysis sessions in 41 patients (554 sessions in total). Failure in the lecture of Kt/V Diascan was observed in 41 sessions (7%). A Diascan Kt/V greater than 1 (the minimum delivered dialysis considered in our unit) was obtained in 93% of the valid sessions. 38 of 41 patients had a mean monthly Diascan Kt/V greater than 1. The coefficient of variability of any patient oscilled between 2.1 and 12.4% (mean 5.1%). Diascan Kt/V is good procedure for the monitoring the delivered dialysis without blood sampling or any additional costs.

Evaluation Studies as Topic↗