Search PubMed⌕ Search

Biomedical subjects

J L Kim

Publications and source records attributed to J L Kim.

At least 19 recordsLinked to original sources

Development of LiF:Mg,Cu,Si TL material (new KLT-300) with a low-residual signal and high-thermal stability.

LiF-based thermoluminescence (TL) materials have been widely used for radiation dosimetry due to their attractive features. LiF:Mg,Cu,P is one of the most sensitive tissue-equivalent TL materials, approximately 40 times more sensitive than LiF:Mg,Ti (TLD-100), but it has two main drawbacks: a thermal loss of the TL sensitivity when annealed at temperatures>240 degrees C, and a relatively high-residual signal. Recently, LiF:Mg,Cu,Na,Si TL material was developed to overcome these drawbacks at the Korea Atomic Energy Research Institute, but it provided only marginal improvements in reducing the residual signal. The newly developed LiF:Mg,Cu,Si TL material has a significantly lower residual signal and a better stability to thermal treatments. In this article, the preparation method and some dosimetric properties (sensitivity and residual signal) of the new LiF:Mg,Cu,Si TL material are presented. At the end of the preparation procedures, a dual-step annealing method is introduced and this has proved as a very efficient method to reduce the high-temperature peak and is the cause of residual signal. Therefore, the high-temperature peak in the glow curve was significantly reduced. The sensitivity is approximately 20 times higher than that of TLD-100 and the residual signal was estimated to be approximately 0.04%.

Dose-Response Relationship, Radiation↗

Thermoluminescence emission spectra for the LiF:Mg,Cu,Na,Si thermoluminescent materials with various concentrations of the dopants (3-D measurement).

The thermoluminescence (TL) emission spectra from LiF TL materials, called KLT-300 (LiF:Mg,Cu,Na,Si) with various dopant concentrations are measured and analysed. These KLT-300 materials were developed by the Korea Atomic Energy Research Institute (KAERI) to achieve an enhancement of the thermal stability in TL readings. Six types of samples are prepared with different dopant concentrations in the following ranges; Mg (0-0.20 mol%), Cu (0-0.05 mol%), Na and Si (0-0.9 mol%). The spectra measurements are carried out for the six types of samples using a TL emission spectra measurement device. The spectra measurement device consists of a monochromator, photomultiplier tube and temperature control unit to thermally stimulate the samples. The measured data shows the light emission during heating of the sample as a function of temperature and wavelength (three-dimensional TL spectra). The spectra were analysed using a method of deconvolution based on gaussian curve. The wavelength of a main peak of the emission spectra changes depending on the existence of the Cu dopant, while intensity of the spectra rapidly changes with the Cu dopant concentrations. The 385 nm emission is mainly observed in all the spectra from the samples with the Cu dopant, but in those from the samples without the Cu dopant a very weak 401 nm emission is mainly observed. However, any change in the wavelength at a main peak of the TL emission spectra from the sample materials with Na and Si dopants is not observed but that in the intensity at a peak of the spectra is observed.

Combinatorial Chemistry Techniques↗

On the relationship between dose-, energy- and LET-response of thermoluminescent detectors.

Measurements of the response of thermoluminescent (TL) detectors after gamma ray doses high enough to observe signal saturation provide input to microdosimetric models which relate this gamma-ray response with the energy response after low doses of photons (gamma rays and low-energy X rays) and after high-LET irradiation. To measure their gamma ray response up to saturation, LiF:Mg,Ti (MTS-7 and MTT), LiF:Mg,Cu,P (MCP-7), CaSO4:Dy (KCD) and Al2O3:C detectors were irradiated with 60Co gamma rays over the range 1-5000 Gy. The X-ray photon energy response and TL efficiency (relative to gamma rays) after doses of beta rays and alpha particles, were also measured, for CaSO4:Dy and for Al2O3:C. Microdosimetric and track structure modelling was then applied to the experimental data. In a manner similar to LiF:Mg,Cu,P, the experimentally observed under response of alpha-Al2O3:C to X rays <100 keV, compared with cross-section calculations, is explained as a microdosimetric effect caused by the saturation of response of this detector without prior supralinearity (saturation of traps along the tracks). The enhanced X-ray photon energy response of CaSO4:Dy is related to the supralinearity observed in this material after high gamma ray doses, similarly to that in LiF:Mg,Ti. The discussed model approaches support the general rule relating dose-, energy- and ionisation density-responses in TL detectors: if their gamma ray response is sublinear prior to saturation, the measured photon energy response is lower, and if it is supralinear, it may be higher than that expected from the calculation of the interaction cross sections alone. Since similar rules have been found to apply to other solid-state detector systems, microdosimetry may offer a valuable contribution to solid-state dosimetry even prior to mechanistic explanations of physical phenomena in different TL detectors.

Computer Simulation↗

Energy responses of the LiF series TL pellets to high-energy photons in the energy range from 1.25 to 21 MV.

The energy responses for the KLT-300(LiF:Mg,Cu,Na,Si, Korea), GR-200(LiF:Mg,Cu,P, China) and MCP-N(LiF:Mg,Cu,P, Poland) thermoluminescence(TL) pellets were studied for a photon radiation with energies from 1.25 MeV(60Co) to 21 MV (Microtron) to verify the usefulness of the calibration for the radiotherapy beams. The International Atomic Energy Agency (IAEA) and the World Health Organization (WHO) have performed thermoluminescence dosimetry (TLD) audits to verify the calibration of the beams by TL powder, but TL pellets were used in this study because the element correction factor (ECF), defined as the factor to correct the variations that all TL dosemeters cannot be manufactured to have exactly the same TL efficiency, for each TL pellet could be accurately derived and be handled conveniently when compared with the powder. Also several works for the energy response of the TLDs were done for the low-energy photon beams up to 60Co, but they will be extended in this experiment to the high photon energies (up to 20 MV), which are widely used in the therapy level of a radiation. The PTW 30006 ionisation chamber was calibrated by the Korea primary standards to establish the air-kerma rates and the TL pellets were irradiated in a specially designed waterproof pellet holder in a water phantom (30 x 30 x 30 cm3) just like the IAEA postal audits programme. This result was compared with that of another type of phantom [10 (W) x 10 (L) x 10 (H) cm3 PMMA Perspex phantom for the 60Co and 6 MV photon, and 10 x 10 x 20 (H) cm3 for the 10 and 21 MV photon] for its convenient use and easy handling and installation in a hospital. The results show that the differences of the responses for the water phantom and PMMA Perspex phantom were negligible, which is contrary to the general conception that a big difference would be expected. For an application of these results to verify the therapy beams, an appropriate energy correction factor should be applied to the energies and phantom types in use.

Computer Simulation↗

Monte Carlo simulation of the photon beam characteristics from medical linear accelerators.

The MCNPX code has been employed on a personal computer to calculate the dosimetric characteristics of the photon beams from the 6 MV Siemens MX2 and the 10 MV Varian Clinac 2100C linear accelerators. A model of the treatment head includes the major geometric structure within the beam path. The model was used to calculate the energy spectra of the photon beam, percentage depth dose and the dose profiles. The accuracy of the calculated results is examined by comparing them with the measured dose distributions for the two machines. The computed and measured depth dose curves agree to within 2% for all the depths beyond the build-up region for both treatment machines. The calculations agree to within 2% of the measured profiles within the 100-50% dose level. It has been found that the MCNPX code is an effective tool for simulating the clinical photon beam.

Body Burden↗

Correlation of gastroesophageal reflux disease symptoms characteristics with long-segment Barrett's esophagus.

Thus far, there has been a paucity of studies that have assessed the value of the different gastroesophageal reflux disease (GERD) symptom characteristics in identifying patients with long-segment Barrett's esophagus versus those with short-segment Barrett's esophagus. To determine if any of the symptom characteristics of GERD correlates with long-segment Barrett's esophagus versus short-segment Barrett's esophagus. Patients seen in our Barrett's clinic were prospectively approached and recruited into the study. All patients underwent an endoscopy, validated GERD symptoms questionnaire and a personal interview. Of the 88 Barrett's esophagus patients enrolled into the study, 47 had short-segment Barrett's esophagus and 41 long-segment Barrett's esophagus. Patients with short-segment Barrett's esophagus reported significantly more daily heartburn symptoms (84.1%) than patients with long-segment Barrett's esophagus (63.2%, P = 0.02). There was a significant difference in reports of severe to very severe dysphagia in patients with long-segment Barrett's esophagus versus those with short-segment Barrett's esophagus (76.9%vs. 38.1%, P = 0.02). Longer duration in years of chest pain was the only symptom characteristic of gastroesophageal reflux disease associated with longer lengths of Barrett's mucosa. Reports of severe or very severe dysphagia were more common in long-segment Barrett's esophagus patients. Only longer duration of chest pain was correlated with longer lengths of Barrett's esophagus.

Adult↗

On the roles of the dopants in LiF: Mg,Cu,Na,Si thermoluminescent material.

In this paper, some results of the study on the roles of the dopants in the LiF:Mg,Cu,Na,Si thermoluminescent (TL) material that was developed at the Korea Atomic Energy Research Institute for radiation protection are presented. Although there have been many studies to investigate the roles of the dopants in LiF:Mg,Cu,P TL material in the TL process, there are some discrepancies in the understanding of the roles of Cu and P between various researchers. In case of LiF:Mg,Cu,Na,Si TL material, there are a few studies on the roles of the dopants. Three kinds of samples in each of which one dopant is excluded, and the optimised sample, were prepared for this study. The measurements and analysis of the three-dimensional TL spectra, based on the temperature, wavelength and intensity, and the glow curves for those samples are used in this study. The results show that Mg plays a role in the trapping of the charge carriers and Cu plays a role in the luminescence recombination process; however, the effect of Na and Si on the glow curve structure and the TL emission spectra is much less than that of Mg and Cu. It is considered that Na and Si each plays a role in the improvement of the luminescence efficiency.

Dose-Response Relationship, Radiation↗

A computer program for the deconvolution of thermoluminescence glow curves.

A quick and efficient computer program was developed in order to resolve the peaks from the thermoluminescence (TL) glow curve. The program was designed to be easily used on any MS Windows-based computer with a graphical user interface. In this program, a new method based on the general one-trap TL equation was adopted to analyse the TL glow curve with the traditional first-order, second-order and general-order kinetics model. The method described here, general approximation, generates TL glow peaks and interpolates the relevant TL parameters from the glow data. The program was tested with simulated and experimental TL glow data and the results were found to be adequate and reliable.

Algorithms↗

Species status and phylogeography of two closely related Coptolabrus species (Coleoptera: Carabidae) in South Korea inferred from mitochondrial and nuclear gene sequences.

We investigated the species status and intraspecific phylogeography in South Korea of two ground beetle species, Coptolabrus jankowskii and Coptolabrus smaragdinus (Coleoptera: Carabidae), using statistical parsimony networks and nested clade analyses based on sequences from the mitochondrial cytochrome oxidase subunit I (COI) and nuclear phosphoenolpyruvate carboxykinase (PepCK) and wingless (Wg) genes. Although traditional parsimony tree construction generally failed to resolve interspecific relationships and construct biologically meaningful genealogies, analysis using statistical parsimony networks yielded statistically significant inter- and intraspecific genealogical structures. We found that although these two species represent a notable case of trans-species polymorphisms in both mitochondrial and nuclear gene sequences, their status as separate species was evidenced by the nonrandom association between species and nested clades at various nesting levels. The exceptional occurrence of shared identical or very similar COI sequences was considered to be the result of introgressive hybridization. In addition, range expansion and fragmentation events across the Korean Peninsula and adjacent islands were inferred from nested clade phylogeographical analyses. The COI gene revealed the geographical divergence of major eastern and western clades and historical biogeographical events within each major clade, whereas the nuclear PepCK gene, which did not reveal corresponding east-west clades, indicated past fragmentation and range expansion across wide areas that may have been the result of older biogeographical events. Thus, phylogeographical inferences drawn from analyses of mitochondrial and nuclear genes can reveal different and potentially complementary information about phylogeographical processes.

Animals↗

Current asthma and respiratory symptoms among pupils in relation to dietary factors and allergens in the school environment.

UNLABELLED: The aim was to study asthma and allergy in relation to diet and the school environment. Pupils (5-14 years) in eight schools received a questionnaire, 1014 participated (68%). Settled dust was collected on ALK-filters and analyzed for allergens from cat (Fel d 1), dog (Can f 1), horse (Equ cx), house dust mites (Der p 1, Der f 1), and cockroach (Bla g 1) by ELISA. In total, 6.8% reported cat allergy, 4.8% dog allergy, 7.7% doctor's diagnosed asthma and 5.9% current asthma, and 7.8% reported wheeze. Current asthma was less common among those consuming more fresh milk (P < 0.05) and fish (P < 0.01). Poly-unsaturated fatty acids was associated with more wheeze (P < 0.05), olive oil was associated with less doctors' diagnosed asthma (P < 0.05). Totally, 74% of the classrooms had mean CO(2) <1000 ppm. The median concentration per gram dust was 860 ng/g Fel d 1, 750 ng/g Can f 1 and 954 U/g Equ cx. Horse allergen was associated with more wheeze (P < 0.05), daytime breathlessness (P < 0.05), current asthma (P < 0.05) and atopic sensitization (P < 0.05). Dog allergen was associated with wheeze (P < 0.05) and daytime breathlessness (P < 0.05). The associations between allergens and respiratory symptoms were more pronounced among those consuming margarine, not consuming butter, and with a low intake of milk. In conclusion, cat, dog and horse allergens in schools could be a risk factor for asthma and atopic sensitization, and dietary factors may interact with the allergen exposure. PRACTICAL IMPLICATIONS: Previous school studies performed by us in mid-Sweden, showed that most classrooms did not fulfill the ventilation standards. In this study, most of the classrooms fulfilled the ventilation standard, but despite that had widespread allergen contamination. Most previous studies have focused on cat allergen, but our study has shown that also dog and horse allergens can be risk factors for asthma and allergy in schools. As allergens are transported from other environments, mainly the home environment, the main prevention should be to minimize transfer of allergens. This could be achieved by reducing contacts with furry pets and horses, or using different clothes at home and at school (e.g. school uniforms). Increased cleaning in the schools may reduce allergen levels, but the efficiency of this measure must be evaluated in further intervention studies. Finally, our study supports the view that dietary habits among pupils should not be neglected and interaction between dietary factors and indoor allergen exposure needs to be further investigated.

Adolescent↗

Developments in the synthesis of LiF:Mg,Cu,Na,Si TL material.

A procedure for synthesis of the highly sensitive pellet-type LiF:Mg,Cu,Na,Si thermoluminescent (TL) detector has been newly developed. It was found that the optimum concentrations of dopants for a pellet-type LiF:Mg,Cu,Na,Si TL detector were found to be Mg: 0.2 mol %, Cu: 0.05 mol %, Na: 0.9 mol%, and Si: 0.9 mol%. The TL sensitivity of this new detector was about 30 times higher than that of the TLD-100 by light integration measurements. Reusability study of the detector was carried out for 10 cycles. The results show that the coefficients of variation for each detector separately did not exceed 0.016, and that for all 10 detectors collectively was 0.0054.

Copper↗

Recovery, growth, and development of Acanthoparyphium tyosenense (Digenea: Echinostomatidae) in experimental chicks.

Chicks were experimentally infected with Acanthoparyphium tyosenense (Digenea: Echinostomatidae) metacercariae per os, and the growth and development of worms in this host were observed from days I to 38 postinfection (PI). The worms grew rapidly and matured sexually in the small intestine (chiefly in the jejunum) of chicks by day 5 PI. and survived at least up to day 38 Pi, although worm recovery decreased after day 5 PI. Both parenchymal and reproductive organs increased greatly in size from day 2 to day 10 PI and then continued to increase gradually in size up to day 38 PI. The number of uterine eggs reached a peak on days 10 and 15 PI and then decreased gradually. The results suggest that chicks are a fairly suitable definitive host for experimental infection with A. tyosenense.

Animals↗

Emission of a hot electron jet from intense femtosecond-laser-cluster interactions.

A directional hot electron jet with energy higher than 100 keV was generated along the laser propagation direction from Ar clusters irradiated with a laser pulse of duration 28 fs and intensity 1 x 10(17) W/cm(2). The hot electron jet was detected only with linearly polarized laser pulses, not with circularly polarized pulses. Channel betatron resonance is believed to be the main accelerating mechanism for this directional hot electron jet.

Journal Article↗

Microdosimetric interpretation of the photon energy response of LiF:Mg,Ti detectors.

Photon energy response of MTS-N (LiF:Mg,Ti) detectors (TLD Poland) and of MTS-N detectors sensitised with 200 Gy of 60Co gamma rays, followed by UV irradiation (sMTS-N), has been determined using X rays with narrow energy spectra, in the energy range from 20 to 300 keV. The over-response of LiF:Mg,Ti detectors for X rays (relative TL efficiency eta = 1.1) can be explained as an ionisation density effect. Low energy X rays produce short electron tracks, which locally deposit a high radiation dose and, consequently, lead to an enhanced (supralinear) response. This over-response has not been observed in sensitised MTS-N where supralinearity in the response after gamma ray doses above 1 Gy is not seen. Using the dose-response curves measured for MTS-N detectors after 137Cs gamma ray irradiation and local doses calculated using Monte Carlo generated electron tracks, it was possible to predict the relative TL effectiveness for different X ray energies. The calculation procedure can be applied to predict the photon energy response of LiF:Mg,Ti detectors in an arbitrary photon field.

Fluorides↗

Thermoluminescence characteristics of teflon embedded CaSO4:Dy TLD.

The Korea Atomic Energy Research Institute (KAERI) is manufacturing CaSO4:Dy Teflon TL pellets which have more sensitivity and stability than commercial TLD. A method is presented of preparing the CaSO4:Dy phosphor-embedded Teflon powder, which is then compressed to a thin pellet form used as the TLD element. Investigations are made to determine optimum preparation conditions and dosimetric characteristics of the CaSO4:Dy Teflon pellet such as the sensitivity, energy response, dose response, fading, re-usability, and lowest level of detection. The results show that the sensitivity of the CaSO4:Dy pellet is 2 times higher than that of the commercial Teledyne CaSO4:Dy pellet. A dose-response was observed to be linear in the range from 10(-5) to 10 Gy. The relative energy response in the low energy region was 9.6 (normalised to the 137Cs gamma source), and the fading rate was about 10% for five months. The re-usability was estimated to be more than 60 cycles, and the low level of detection dose was 22 microGy. From the results, the CaSO4:Dy pellet developed in KAERI can be successfully used in personal dosemeters through appropriate filter design for compensating the energy response.

Calcium Sulfate↗

Analysis of the glow curves obtained from LiF:Mg,Cu,Na,Si TL material using the general order kinetics model.

Three-dimensional thermoluminescence (TL) spectra based on temperature, wavelength and intensity for newly developed LiF:Mg,Cu,Na,Si TL material at the Korea Atomic Energy Research Institute (KAERI) were measured and analysed. The glow curves were obtained by integration of luminescence intensity over all wavelengths at each temperature, and various trapping parameters related to the traps were determined by analysing these curves. A computerised glow curve deconvolution (CGCD) method which was based on the general order kinetics (GOK) model was used for the glow curve analysis. The glow curves of LiF:Mg,Cu,Na,Si TL material were deconvoluted to six isolated glow curves which have peak temperatures at 333, 374, 426, 466, 483 and 516 K. The main glow peak of peak temperature at 466 K had activation energy of 2.06 eV and a kinetic order of 1.05. This TL material was also found to have three recombination centres, 1.80 eV, 2.88 eV and 3.27 eV by analysis of the TL spectra.

Copper↗

Thermoluminescence properties of LiF:Mg,Cu,Na,Si pellets in radiation dosimetry.

Sintered LiF:Mg,Cu,Na,Si thermoluminescence (TL) pellets have been developed for application in radiation dosimetry. LiF:M,Cu,Na,Si TL pellets were made from TL powders using a sintering process, that is, pressing and heat treatment. These pellets have a diameter of 4.5 mm, and a thickness of 0.8 mm are blue in colour and have a mass of 28 mg each. After 400 pellets had been produced they were irradiated with 137Cs gamma radiation and samples having a sensitivity within a +/-5% standard deviation were selected for experimental use. In the present study, the physical and dosimetric properties of LiF:Mg,Cu,Na,Si TL pellets were investigated for their emission spectrum, dose response, energy response and fading characteristics. Photon irradiation for the experiments was carried out using X ray beams and a 137Cs gamma source at the Korea Atomic Energy Research Institute (KAERI). The average energies and the dose were in the range of 20-662 keV and 10(-6) - 10(2) Gy respectively. The glow curves were measured with a manual type thermoluminescence dosimetry reader (system 310, Teledyne) at a constant nitrogen flux and a linear heating rate. For a constant heating rate of 5 degrees C.s(-1). the main dosimetric peak of the glow curve appeared at 234 degrees C, its activation energy was 2.34 eV and the frequency factor was 1.00 x 10(23). The TL emission spectrum appeared at the blue region centred at 410 nm. A linearity of photon dose response was maintained up to 100 Gy. The photon energy responses relative to the 137Cs response were within +/-20% in the overall photon energy region. No fading of the TL sensitivity of the pellets stored at room temperature was found over the course of a year. Therefore LiF:Mg,Cu,Na,Si TL pellets can be used for personal dosimetry, but more research is needed to improve the characteristics for repeated use.

Copper↗

Comparison of TLD algorithms for monochromatic fluorescent radiation and continuous spectrum X rays.

A personal dosimetry system is required to measure the personal dose equivalent accurately in a wide range of radiation fields. However, the dose evaluation algorithm at the Korea Atomic Energy Research Institute (KAERI) has been developed with the spectral X ray fields described in the American National Standards Institute (ANSI) Standard N13.11 and the actual fields to be monitored may be significantly different from these. To evaluate the dose more accurately when workers are exposed to non-ANSI N13.11 radiation fields, a dose evaluation algorithm using monochromatic radiation (monochromatic algorithm) was developed using the experimental data of the energy responses of CaSO4:Dy thermoluminescent materials irradiated by monochromatic fluorescent X ray fields recently established at KAERI; this was compared with another algorithm developed on the basis of the ANSI N13.11 continuous spectrum X ray fields (spectrum algorithm). The paper concludes with discussions about some results of the algorithm test, including mixed field irradiation and angular response, conducted in an International Atomic Energy Authority/Regional Cooperation of Asia (IAEA/RCA) intercomparison study.

Algorithms↗