Search PubMed⌕ Search

Biomedical subjects

J L Doppman

Publications and source records attributed to J L Doppman.

At least 181 records · Page 10Linked to original sources

Myelopathy due to intracranial dural arteriovenous fistulas draining intrathecally into spinal medullary veins. Report of three cases.

Arteriovenous malformations (AVM's) of the spine commonly cause progressive myelopathy. Occasionally, myelography reveals serpentine filling defects characteristic of a spinal AVM, but an AVM or arteriovenous (AV) fistula cannot be demonstrated arteriographically, despite selective catheterization of all vessels known to have the potential of supplying the spinal cord and spinal dura. Often, and particularly in the setting of subacute or acute deterioration, this has been attributed to spontaneous thrombosis of the veins (the Foix-Alajouanine syndrome). Three patients are reported in whom intracranial dural AV fistulas, supplied by branches of the internal and external carotid arteries, drained into spinal veins and produced myelopathy. In one patient, motor and sensory deficits were limited to the lower extremities. In all three patients, disconnection of the fistula from its spinal venous drainage permitted arrest of a rapidly progressive myelopathy and partial recovery. These findings indicate that some patients who appear to have spinal cord AVM's but exhibit negative spinal arteriography are suffering from cranial dural AV fistulas and therefore need carotid as well as spinal arteriography. The considerable distance of these fistulas from the level of neurological expression supports venous hypertension as a pathophysiological mechanism of spinal cord injury. Interruption of a cranial dural fistula draining into spinal veins permits recovery of the myelopathy.

Adult↗

Reduced systemic drug exposure by combining intraarterial cis-diamminedichloroplatinum(II) with hemodialysis of regional venous drainage.

During cancer chemotherapy toxicity to normal tissues often limits the tolerable dose. To increase drug delivery to tumor while maintaining tolerable systemic exposure, regional treatments, such as intraarterial drug delivery, have been used. Despite intraarterial delivery, systemic toxicity often remains the dose-limiting sensitivity. If systemic drug exposure could be reduced after intraarterial infusion, the intraarterial dose could be increased, which should increase the therapeutic response. We compared the pharmacokinetic advantage after cisplatin infusion into the internal carotid artery to that obtained after infusing cisplatin into the internal carotid artery during extracorporeal removal of cisplatin from the jugular blood by hemodialysis. Four patients with malignant gliomas received intracarotid cisplatin, 100 mg/m2 over 60 min, every 4 weeks. During one treatment, while cisplatin was infused into the internal carotid artery, the jugular blood was dialyzed extracorporeally at 300 ml/min and returned to the inferior vena cava. Seventy to 96% of the free platinum that entered the dialyzer was removed. By aspirating blood from the jugular vein at 300 ml/min, 30-79% of the ipsilateral carotid blood was collected for extracorporeal circulation. Hemodialysis of the cerebral venous drainage during intracarotid infusion reduced the systemic exposure to cisplatin by 51-61% when compared to the exposure from internal carotid artery infusion without hemodialysis. The pharmacokinetic advantage (brain/body exposure ratio) was increased from 3 to 5/1 during internal carotid artery infusion alone to as much as 15/1 during treatment combining intracarotid infusion with hemodialysis of the jugular blood. Systemic toxicity now limits the dose of cisplatin that can be administered safely. Increased tumor exposure without increased systemic toxicity may be possible with the technique described and greater doses of cisplatin. Assuming no associated local toxicities, the results of the current study indicate that the dose of intracarotid cisplatin can be increased while maintaining tolerable systemic exposure.

Brain Neoplasms↗

Comparison of angiography and ultrasound in the evaluation of the portal venous system in pancreatic carcinoma.

Detailed images of upper abdominal vascular anatomy can now be obtained by experienced operators using modern real-time ultrasound scanners. To help determine the role of real-time ultrasound in preoperative evaluation of pancreatic carcinoma, ultrasound and angiographic results were compared in a series of 45 patients admitted with documented carcinoma of the pancreas. When surgical results were available, these were compared with the ultrasound and angiographic findings. The main tributaries of the portal system were evaluated with ultrasound and angiography for evidence of compression, displacement, or occlusion. A sensitivity of 90% and specificity of 95% were achieved for splenic vein abnormalities by ultrasound compared to angiography. For portal vein evaluation, sensitivity was 75%, and specificity was 100%, whereas for the superior mesenteric vein a sensitivity of 100% and a specificity of 94% were attained. Ultrasound can make angiography prior to laparotomy unnecessary in many cases if thorough evaluation of the portal venous system is emphasized during the initial ultrasound study.

Humans↗

Prospective study of the ability of computed axial tomography to localize gastrinomas in patients with Zollinger-Ellison syndrome.

The ability of routine computed tomography (CT) performed with oral and intravenous contrast to localize gastrinomas in 61 consecutive patients with Zollinger-Ellison syndrome was evaluated prospectively. The results of CT scanning were subsequently evaluated in all patients by either surgery, autopsy, or percutaneous biopsy. Thirteen of 14 patients with CT scans positive for hepatic metastases and 5 of 13 patients with CT scans negative for hepatic metastases were found to have gastrinoma in the liver. For gastrinoma metastatic to the liver, CT scanning had a specificity of 98%, a sensitivity of 72%, a positive predictive value of 93%, and a negative predictive value of 90%. Twenty-two of 23 patients with positive extrahepatic CT scans and 15 of 33 patients with negative extrahepatic CT scans were found to have extrahepatic gastrinomas. For extrahepatic gastrinoma, CT scanning had a specificity of 95%, a sensitivity of 59%, a positive predictive value of 96%, and a negative predictive value of 54%. The ability of CT scan to detect gastrinomas both in the liver and extrahepatically was directly related to tumor size, detecting 0% of tumors less than 1 cm and 83%-95% of tumors greater than 3 cm. The location of the extrahepatic gastrinoma was also an important determinant in that approximately 80% of pancreatic gastrinomas but only 35% of extrapancreatic gastrinomas were detected. The present results indicate that because of its convenience and accuracy, CT scanning with oral and intravenous contrast material should be the initial procedure to evaluate the extent of gastrinoma. A positive CT scan is almost always correct; therefore, a CT scan detecting metastatic gastrinoma to the liver would avoid unnecessary surgery and, if positive for extrahepatic gastrinoma, would assist the surgeon in finding the gastrinoma. A negative CT is less reliable; therefore, patients should undergo other localizing studies before exploratory laparotomy.

Biopsy↗

Role of selective angiography in the management of patients with Zollinger-Ellison syndrome.

To determine the ability of selective abdominal angiography to localize gastrinoma in patients with Zollinger-Ellison syndrome, selective angiography was performed in 70 consecutive patients and the results were assessed prospectively by either surgery, autopsy, or percutaneous biopsy. In addition, to define the role of angiography in the management of patients with gastrinoma, we compared the results of angiography with those of computed tomography (CT) scanning in 58 patients who underwent both tests. For gastrinoma in the liver, angiography had a specificity of 100% and a sensitivity of 86% with a positive predictive value of 100% and a negative predictive value of 94%. For extrahepatic gastrinoma, angiography had a specificity of 94% and a sensitivity of 68%, a positive predictive value of 97% and a negative predictive value of 53%. Comparison of CT scanning and angiography demonstrated that for hepatic tumor CT demonstrated 72% and angiography 89% of tumors, and the combination detected all tumors with no false-positive results. Outside the liver, CT scanning detected 57%, angiography 70%, and the combination 73% of tumors with a false-positive rate of 7%. These results indicate that if a CT scan is performed first, then the addition of selective angiography will detect a further 28% of hepatic tumors and a further 16% of extrahepatic tumors, but that 24% of extrahepatic tumors will still be missed. Angiography is a useful adjunct to CT particularly in patients in whom surgery is contemplated.

Abdomen↗

Magnetic resonance imaging versus computed tomography in the evaluation of soft tissue tumors of the extremities.

Twenty patients with extremity soft tissue tumors were prospectively evaluated with magnetic resonance imaging (MRI) and computed tomography (CT) scans with subsequent anatomic correlation of surgical findings. MRI and CT had a similar percentage of accuracy in assessing tumor relationship with major neurovascular (80% and 70%, respectively) and skeletal (80% and 75%, respectively) structures. MRI was significantly better than CT in displaying contrast between tumor and muscle when using the T2 weighted spin echo (SE) (p2 less than 0.002) and inversion recovery (IR) (p2 less than 0.005) pulse sequences. MRI and CT were comparable in demonstrating contrast between tumor and fat. The contrast between tumor and vessel was better displayed by MRI compared with CT when using the T1 weighted SE (p2 less than 0.001) and T2 weighted SE (p2 less than 0.001) pulse sequences. T1 and T2 values were measured on fresh tumor and normal tissue samples and were used to predict relative contrast on different MRI pulse sequences using isosignal contour plots. MRI appears to offer several advantages over CT in the evaluation of extremity soft tissue tumors.

Arm↗

Localization of parathyroid adenomas in patients who have undergone surgery. Part I. Noninvasive imaging methods.

The authors evaluated computed tomography (CT), ultrasound (US), technetium/thallium scintigraphy, and magnetic resonance (MR) imaging as localization procedures in 53 patients with proved parathyroid adenomas and previous unsuccessful parathyroid surgery. CT had the highest overall sensitivity (47%), followed by US (36%) and scintigraphy (27%). There is still too little data to assess MR imaging. Adenoma size affected the sensitivity of CT, scintigraphy, and MR imaging but not US. When all three studies were used, at least one study depicted a lesion in 78% of patients, but definitive localization (two positive studies) was achieved in only 31%.

Adenoma↗

Localization of parathyroid adenomas in patients who have undergone surgery. Part II. Invasive procedures.

The authors studied intraarterial digital subtraction angiography (DSA), conventional selective angiography, parathyroid venous sampling (PVS), and intraoperative ultrasound (US) as localization procedures for parathyroid adenomas in 53 patients with proved parathyroid adenomas and previous unsuccessful parathyroid surgery. PVS had the highest overall sensitivity as a single study (80%), followed by intraoperative US (78%), angiography (60%), and DSA (49%). Invasive procedures permitted successful localization of adenomas in 41 of 43 patients studied (95%). False-positive studies were uncommon. The optimum sequence of invasive localization procedures is determined by clinical factors and not by the sensitivity of individual tests. The authors recommend DSA be performed first, followed by angiography, PVS, and intraoperative US, in that order.

Adenoma↗

Liver metastasis detection: comparative sensitivities of MR imaging and CT scanning.

Twenty patients with known liver metastases were evaluated by unenhanced computed tomography (CT), scans enhanced with ethiodized oil emulsion-13 (EOE-13), and magnetic resonance (MR) imaging with three pulse sequences. Spin-echo (SE) 300/26 (repetition time/echo time, in msec) images prospectively demonstrated 95.4% of the detectable liver metastases; inversion recovery (IR) 1,500/100 (repetition time/inversion time, in msec) images revealed 90.8%; and EOE-13-enhanced CT scans showed 87.1%. SE 2,000/80 images showed 51.4%, and unenhanced CT scans 49.6%, of the metastases. The relationship of vascular anatomy to metastatic foci was best seen on SE 300/26 images and EOE-CT scans. SE 300/26, IR 1,500/100, and EOE-CT studies particularly improved detection of lesions in the 1-2-cm range compared with SE 2,000/80 imaging or unenhanced CT scanning. SE 300/26 and IR 1,500/100 sequences appear comparable to EOE-CT scans in demonstrating liver metastases and significantly superior to conventional CT scans. Because EOE-13 is generally not available, these MR sequences should be the procedure of choice for the diagnosis of liver metastases.

Carcinoma↗

Cushing syndrome: pituitary CT scanning.

Proper treatment of patients with Cushing syndrome depends on knowledge of whether the condition derives from a pituitary or adrenal adenoma or an ectopic tumor that secretes adrenocorticotropic hormone (ACTH). Fifty-seven patients with Cushing syndrome were prospectively evaluated to determine whether computed tomography (CT) of the pituitary gland is useful in diagnosing or excluding an ACTH-producing adenoma and in predicting the site of the adenoma within the pituitary gland. Findings on CT scans were normal in 35 of 50 patients with surgically confirmed Cushing disease and in seven patients with ectopic ACTH-producing tumors. Of the 15 patients with Cushing disease for whom CT results were abnormal, eight had macroadenomas and seven had microadenomas. This study demonstrates a low sensitivity (30%) and low diagnostic accuracy (39%) of CT in the detection of ACTH-producing pituitary tumors and indicates the need for alternative methods of confirming the pituitary origin of excessive ACTH secretion in most patients.

Adenoma↗

Identification of ACTH-producing intrathoracic tumors by measuring ACTH levels in aspirated specimens.

Three patients with Cushing syndrome secondary to ectopic adrenocorticotropic hormone (ACTH) production underwent direct 22-gauge needle aspiration of bronchial (two cases) and mediastinal (one case) carcinoid tumors. High levels of ACTH were measured in all three tumors. This technique permits absolute identification of an ectopic source of ACTH before surgery.

ACTH Syndrome, Ectopic↗

Pituitary adenomas in patients with Cushing disease: initial experience with Gd-DTPA-enhanced MR imaging.

To assess the role of magnetic resonance imaging in the evaluation of adrenocorticotropic-hormone (ACTH)-producing pituitary adenomas, and the effect of intravenously administered gadolinium-diethylenetriaminepentaacetic acid (DTPA) on lesion/pituitary contrast, imaging was performed in 13 patients with clinical and chemical evidence of Cushing disease. Images were obtained at 0.5 T before and after the injection of Gd-DTPA (0.1 mmol/kg). Lesions were identified in eight of 12 precontrast and ten of 12 postcontrast studies. In these 12 patients adenomas were found at transsphenoidal surgery. The other patient, with normal images, was found to have an ectopic source of ACTH. Coronal images corresponded remarkably well with the neurosurgeon's intraoperative findings. Serial T1-weighted images disclosed early enhancement of the pituitary gland and delayed enhancement of the cystic adenomas. The discrepancy in times to peak enhancement accounted for improved lesion/pituitary contrast in some early images and for reversal or diminution of lesion/pituitary contrast in later images.

ACTH Syndrome, Ectopic↗

Ocular and cerebral metastases in the VX2 rabbit tumor model: contrast-enhanced MR imaging.

Ocular and cerebral metastases developed after the inoculation of a VX2 tumor cell suspension into the internal carotid artery of 15 rabbits. The hematogenous spread of tumor cells resulted in ocular metastases in 13 of 15 animals (86.7%) and cerebral system metastases in 14 of 15 animals (93%). Magnetic resonance (MR) imaging with Gd-DTPA demonstrated early disruption of the blood-ocular barrier and blood-brain barrier 5-7 days after infusion of tumor cells. Quantitative assessment of contrast enhancement revealed a mean increase in signal intensity of 145% +/- 51% in the anterior chambers, 102% +/- 70% for choroidal metastases, and 51% +/- 29% for central nervous system (CNS) metastases. These results indicate that contrast-enhanced MR imaging can be used to demonstrate a loss of blood-ocular barrier integrity that is similar to the breakdown of the blood-brain barrier associated with metastatic tumors to the CNS and eye.

Animals↗