Frequency and implications of resetting and entrainment with right atrial stimulation in atrial flutter.

Thirty-three patients (24 with typical and 9 with atypical flutter-wave morphology) were studied to evaluate the incidence and implications of resetting and entrainment of atrial flutter with right atrial stimulation. Resetting with single extrastimulus was present in 23 cases (group A) and absent in 10 (group B). Most cases of reset flutter were typical (20 of 23). Fixed fusion indicative of entrainment was observed in all 29 cases with pacing trains. Groups A and B did not differ significantly in flutter cycle length (230 +/- 20 vs 223 +/- 19 ms), atrial functional refractory period (165 +/- 18 vs 167 +/- 22 ms) or longest paced cycle length producing entrainment (213 +/- 19 vs 210 +/- 19 ms). In contrast, the return cycle after the longest paced cycle length producing entrainment was significantly shorter in group A (228 +/- 27 vs 284 +/- 56 ms; p = 0.001). The return cycle in group A was virtually identical to the flutter cycle length, whereas in group B it was greater (p = 0.002 compared with group A). Resetting was more frequent in typical than atypical flutter (20 of 24 vs 3 of 9; p = 0.01). Both typical and atypical flutter can be transiently entrained by right atrial pacing. Lack of resetting and longer return cycle, suggesting a longer conduction time between the reentrant circuit and the stimulation site, were mostly observed in atypical flutter. The data suggest a different location for both types of flutter, and may have implications for ablation techniques. A more cautious approach, with more extensive mapping, appears appropriate for ablation attempts of atypical flutter.

Adult↗

Rate-dependent failure of ventricular capture in patients treated with oral propafenone.

The effects of propafenone on ventricular excitability were studied in 18 patients after 9 +/- 6 days on oral propafenone (900 mg/day). Late diastolic double threshold right ventricular stimulation was performed at variable rates. In five patients (28%, group I) an intermittent, rate-dependent failure of ventricular capture was reproducibly observed during stimulation at rates above the sinus rhythm but not exceeding 150 beats min-1. In four patients loss of capture was preceded by gradual prolongation of the interval between the stimulus artifact and the local right ventricular bipolar electrogram. Such findings were not observed in the remaining 13 patients (group II) on propafenone nor in 28 studies in the same patients on different antiarrhythmic agents. Group I vs group II patients were older (72 +/- 4 vs 53 +/- 18 years, P = 0.002), had longer right ventricular effective refractory periods on the baseline (P = 0.004) and on propafenone (P = 0.0003), and had longer QRS duration on propafenone. The increase produced by propafenone in sinus rhythm QRS duration, paced QRS duration and ventricular effective refractory period was greater in group I than in group II: 42 +/- 36 vs 14 +/- 12 ms, P = 0.01, 94 +/- 43 vs 34 +/- 26 ms, P = 0.0002, 88 +/- 64 vs 22 +/- 37 ms, P = 0.025, respectively. Thus propafenone can produce rate-dependent failure of ventricular capture which is associated with marked prolongation of refractoriness and QRS duration suggesting a marked use-dependent drug effect in selected patients.

Administration, Oral↗

[Occurrence of dynamic atrial spontaneous contrast in patients with mitral disease].

OBJECTIVE: The aim of this study was to analyze, through transesophageal echocardiography, different factors related to left atrial spontaneous echocardiographic formation. DESIGN: Transthoracic and transesophageal comparative study of left atrial thrombotic phenomena. SETTING: Ambulatory and in hospital patients referred to Gregorio Marañon General Hospital Echocardiographic Laboratory. PATIENTS: 120 consecutive patients with mitral valve disease or prosthesis were included in this transesophageal echocardiographic prospective study. All patients were divided in two groups, according with left atrial spontaneous contrast. In each patient we measured total left atrial area, rhythm abnormalities, mitral valve area, left atrial cavity thrombus and maximal mitral regurgitation area. MEASUREMENTS AND RESULTS: Transthoracic echocardiography did not detect any patient with left atrial spontaneous contrast, compared to 57.5% diagnosed through the transesophageal technique. Transesophageal echocardiography diagnosed left atrial thrombosis in 19% (n = 23) of patients compared to 1% (n = 2) through the transthoracic technique. In the group with left atrial contrast, 59% of patients had mitral regurgitation less than 600 mm2, 64% were in atrial fibrillation and left atrial total area was 28 +/- 10.8 mm2. CONCLUSIONS: Transesophageal echocardiography is the technique of choice to diagnose, with greater security, left atrial cavity thrombosis, and establish the relationship of echocardiographic variables and left atrial thrombotic phenomena. Among these echocardiographic factors, left atrial dynamic spontaneous echocontrast is fundamental.

Adult↗

[Transesophageal echocardiography study of mitral valve prosthesis].

OBJECTIVE: Transesophageal (TEE) and Transthoracic (TTE) comparative echocardiographic analysis of patients with mitral valve prosthesis. DESIGN: Prospective study. SETTING: In hospital and out patients with mitral prosthesis in a follow-up study by the Cardiology Department and referred to the echocardiographic laboratory of Gregorio Marañon General Hospital, Madrid. PATIENTS: We studied 90 consecutive patients with mitral prosthesis diagnosis. INTERVENTIONS: Comparative and prospective echocardiographic study of transthoracic and transesophageal techniques in mitral prosthesis pathology. RESULTS: TTE diagnosed 18% of dysfunctioning mitral prosthesis patients compared to 56% of cases identified by TEE. TTE observed 1% of mitral prosthesis vegetation compared to 8.8% by TEE. TEE diagnosed left atrial thrombosis in 2.2% and TEE in 10%. Left atrial spontaneous dynamic contrast was identified exclusively by TEE in 55% of all cases. Paravalvular mitral prosthesis leak was correctly identified exclusively by TEE in 20% of cases. CONCLUSIONS: TEE has a greater diagnostic capacity compared to TTE in mitral prosthesis patients. This technique can give a greater security in evaluating mitral prosthesis thrombi, vegetations and leak, establishing a more precise diagnosis of mitral prosthesis dysfunction. The authors concluded that TEE is the technique of choice in noninvasive evaluation of patients admitted with the suspicion of mitral prosthesis dysfunction.

Adult↗

[Changes in the physiologic pattern of mitral prosthesis regurgitation in the presence of a prosthetic dysfunction].

AIM OF STUDY: Evaluation by transesophageal echocardiography of the effect on the characteristics of physiological regurgitant jets (JF) resulting from prosthetic disfunction due to pathologic regurgitation (JF). PATIENTS AND METHODS: We studied 69 consecutive patients with the diagnosis of prosthesis in mitral position using transesophageal echocardiography and color doppler codification. The patients were divided in two groups (N and D groups) according to the presence of prosthesis disfunction by pathologic regurgitation. In each patient we determined planimetric areas and atrial peak depth of each JF and also the sum of JF planimetric areas of each mitral prosthesis. When pathological regurgitation was present we calculated the highest planimetric area, severity degree and atrial peak depth in each JP. RESULTS: The planimetric area in each JF of group N was 330 +/- 167 mm2 and in group D 117 +/- 116 mm2 (p less than 0.001). The sum of the areas of JF in group N was 474 +/- 204 mm2 and in group D 254 +/- 176 mm2 (p less than 0.01). The atrial depth of JF in group was 32 +/- 15 mm and in group D 26 +/- 18 mm (p less than 0.01). In group D 29% of the patients had mild pathological regurgitation, 10% moderate and 61% severe. The maximum planimetric area of JP in group D was 1078 +/- 1007 mm2 with atrial depth of 37 +/- 28 mm. CONCLUSION: The pathological regurgitation in disfunction prosthesis in mitral position has a significant reduction effect in the dimension of prosthesis physiologic regurgitation jets. This transesophageal echocardiographic observation makes it possible to characterize and clarify more precisely the different types of mitral prosthesis jets.

Adult↗

An epidemic of pulmonary hypertension after toxic rapeseed oil ingestion in Spain.

The cardiac profile of 38 patients readmitted to the hospital with the clinical and radiologic findings of pulmonary artery hypertension and right ventricular failure 2 months after ingestion of toxic rapeseed oil was determined with M-mode and two-dimensional echocardiography, pulsed Doppler flow studies and right and left heart catheterization and ventriculography. The echocardiogram and pulsed Doppler recordings revealed right ventricular enlargement in 84% of the patients, indirect evidence of pulmonary artery hypertension in 76% and tricuspid insufficiency in 13%. At cardiac catheterization (n = 11) the mean (+/- standard deviation) pulmonary artery pressure was 40 +/- 9 mm Hg, mean pulmonary systemic vascular resistance ratio was 0.45 +/- 0.12 and mean right ventricular end-diastolic pressure was 13 +/- 4 mm Hg. Pulmonary artery hypertension was sustained after the acute administration of 100% oxygen and persisted in six patients who were restudied within 6 months. Cardiac index and left heart pressures were normal in all but one patient. The contrast ventriculographic studies revealed right ventricular dilation in all patients, tricuspid regurgitation in three patients and a normal left ventricular contraction pattern in all but one patient. The data confirm that symptomatic pulmonary artery hypertension and associated right ventricular dysfunction can complicate toxic rapeseed oil ingestion and that these findings persist for at least 6 months.

Acetanilides↗

Hemodynamic evaluation of the Angell-Shiley porcine xenograft.

The Angell-Shiley porcine xenograft was evaluated in 48 asymptomatic subjects who underwent cardiac catheterization an average of 14 months after operation. Nineteen patients had mitral and 29 had aortic valve replacement. The average mitral valve gradient was 8 +/- 3 mm Hg and the average effective orifice area was 1.8 +/- 0.6 cm2. The average aortic valve gradient was 22 +/- 7 mm Hg and the average effective orifice area was 1.2 +/- 0.3 cm2. During supine leg exercise, the average mitral valve gradient increased to 12 +/- 4 mm Hg (p less than 0.001) and the average aortic valve gradient increased to 27 +/- 8 mm Hg (p less than 0.001) compared to findings at rest. On the basis of data obtained with a regression analysis model, there is a high probability that an Angell-Shiley aortic xenograft with a stent diameter less than 25 mm will have a postoperative effective orifice area of less than 1 cm2, and that an Angell-Shiley mitral xenograft with a stent diameter less than 30 mm will have a postoperative effective orifice area of less than 1.5 cm2. Our data suggest that the Angell-Shiley xenograft has suboptimal hemodynamic performance in stent sizes less than 30 mm in the mitral position and less than 25 mm in the aortic position.

Adult↗

Clinical and hemodynamic assessment of the Angell-Shiley porcine xenograft.

Valve replacement with an Angell-Shiley bioprosthesis was accomplished in 449 patients. To evaluate the bioprostheses from this total series, 344 patients who did not undergo associated operation, had no previous operations, or had no other valve substitutes were selected. Hospital mortality was 2.6% for aortic (4 out of 156), 7.2% for mitral (9 out of 125), and 12.7% for multiple-valve replacements (8 out of 63). The 323 patients discharged from the hospital were followed for 6 to 36 months. There were 15 late deaths. Hepatitis, bleeding, thromboembolism, endocarditis, and residual valvular incompetence, always periprosthetic, were the major complications. Forty-five patients with single-valve replacement (16 mitral and 29 aortic) without clinical valve dysfunction were electively recatheterized to assess hemodynamic performance. Measurements were recorded at rest and during exercise on a bicycle ergometer. Functional aortic valve orifice averaged 1.23 +/- 0.33 cm2 and the mean systolic gradient was 21.51 +/- 6.68 mm Hg at rest. During exercise, aortic gradient increased to 26.60 +/- 7.54 mm Hg and mean functional area to 1.51 +/- 0.34 cm2. In the mitral position, the mean diastolic gradient at rest was 8.44 +/- 3.17 mm Hg and the functional orifice area averaged 1.67 +/- 0.51 cm2. Exercise increased the mean gradient to 11.92 +/- 3.8 mm Hg and the mean orifice area to 2.05 +/- 0.57 cm2.

Adolescent↗

Surgical treatment of coronary insufficiency produced by cardiac echinococcosis.

We report two cases in which the pertinent angiographic studies disclosed the presence of hydatid cysts of the left ventricle, producing complete obstruction of the left anterior descending coronary artery in one patient and of the left anterior descending coronary artery and the circumflex coronary artery in the other patient. Both patients were successfully treated by excision of the cyst and myocardial revascularization with saphenous venous bypass grafts. From the analysis of symptoms in cardiac echinococcosis, we concluded that precordial pain is the most common complaint, that it can be due to coronary insufficiency, and that at the present, coronary angiographic studies have to be performed systematically in these patients, since coronary involvement by the cyst can explain some of the clinical manifestations and complications of the disease and can also influence its surgical management.

Angiography↗

Factors influencing better results in operation for postinfarction ventricular aneurysms.

A series of 66 consecutive patients operated on for postinfarction ventricular aneurysm is reviewed with regard to the factors influencing the progressive decline of mortality (3.2% in the last 31 patients seen). The method of myocardial protection has a significant influence on mortality, which was 45% in patients operated on with aortic cross-clamping under conventional hypothermia and 5% in patients operated on under profound local hypothermia. Associated revascularization with vein bypass graft was performed in 28 patients, without mortality. The technique of aneurysmectomy adapted to the extension and location of the fibrotic scar is described, with exclusion of the septal portion of the aneurysm in 85% of the patients. In 36 patients who had postoperative cardiac catheterization, this technique produced normal ejection fraction and near normal left ventricular volumes

Angiocardiography↗

Echocardiographic sign of right-sided hypertrophic obstructive cardiomyopathy.

The echocardiographic and haemodynamic findings with a patient with hypertrophic obstructive cardiomyopathy (HOCM) and dynamic subpulmonary stenosis, without left ventricular gradient, are described. The echocardiogram shows not only asymmetric septal hypertrophy, systolic anterior movement of the anterior mitral leaflet, and midsystolic collapse of the aortic valve, but also increase in the right ventricular wall echoes and systolic collapse of the pulmonary valve. We believe that in the absence of pulmonary hypertension these signs, particularly the systolic closing movement of the pulmonary valve cusp, may suggest right ventricular obstruction in HOCM.