The sequence at the termini of four genes of the three reovirus serotypes.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to J K Li.
Explore the source record for details and available documents.
This paper studies the problem of identification of suitable biological variables for optimal effectiveness of a CAD. To identify suitable error signals, a closed loop simulation and analysis of the assisted circulation was carried out. Results show that the combination of heart rate and left atrial pressure is very effective as an input error signal for either series or parallel assisted circulation when simulated heart failure is severe (greater than 50% decrease in left ventricular elastance). During simulated exercise (50% reduction in peripheral resistance) such a combination is even more effective. In addition, simulation results show that aortic pressure and cardiac output are not suitable control variables for CAD.
Mice were studied for 3 to 4 months after murine cytomegalovirus (MCMV) infection. Serial hematological parameters were evaluated. It was found that MCMV infection of mice were accompanied by the appearance of many atypical lymphocytes similar to those seen in association with the hematological features of mononucleosis associated with human CMV infection. Certain functions of splenocytes were studied in infected and uninfected animals during the 4 months after MCMV infection. Three periods were identifiable by the functional response of splenocytes during the course of MCMV infection. The initial phase was characterized by an elevated response of splenocytes to a T cell mitogen and a B cell mitogen (phytohemagglutinin and lipopolysaccharide, respectively). The intermediate phase was marked by productive virus replication in the salivary gland, injury to lymphoid elements, a depressed response of splenocytes to mitogens (phytohemagglutinin and lipopolysaccharide), and decreased humoral splenocytes to phytohemagglutinin stimulation was again increased, and a nonproductive latent infection was established. Study by scanning electron microscopy of splenocytes during the course of infection revealed morphological changes which were correlated with functional alterations.
This report evaluates pulse wave propagation with respect to contributions by vascular wall elastic and geometric properties, vessel wall and blood viscosity, and nonlinearities in system parameters and in the equations of motion. Discrepancies in results obtained with different experimental methods and theory are discussed and resolved. A three-point pressure technique was used to obtain measurements from the abdominal aorta, carotid, iliac, and femoral arteries of dogs. Computations involved linear, as well as nonlinear methods. Results are presented along a continuous path of transmission (abdominal aorta, iliac, femoral), and it is shown that variations in phase velocity can be explained entirely by the geometric variation of these vessels. Phase velocities are shown to be frequency independent at approximately greater than 4 Hz whereas attenuation increases progressively for higher frequencies. Determination of propagation coefficients using maximal, compounded values of reported viscoelastic and geometric properties just manages to span the range of phase velocities, determined in different laboratories, but does not do so for attenuation. Also, differences in experimental techniques cannot explain these discrepancies. Consideration of geometric taper, nonlinear compliance, all the terms in the equation of motion, and the effect of wall and blood viscosity resolves discrepancies between theoretical and experimentally derived phenomena.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Treatment of Newcastle disease virus with lithium diiodosalicylate differentially elutes the internally disposed proteins, M and NP, showing that these proteins are extrinsic, i.e., not associated with the lipid hydrophobic core. This selective elution requires disruption of the viral envelope, a process that is maximal at low temperature and influenced by the lipid composition of the virus envelope.
Explore the source record for details and available documents.
A case of splenic invasion and rupture by a pancreatic pseudocyst is presented and previously documented cases are reviewed. The serious consequences of this complication are stressed. In the present case, splenic rupture occurred during clinical and radiological resolution of the pseudocyst.
The performance of catheter-manometer systems for the measurement of pulsatile pressure has been evaluated by both experimental techniques and theoretical considerations. The former approach has shown, on occasion, multiple maxima in the amplitude response. The latter has been approached in a variety of ways, ranging from extreme lumping to application of transmission line theory while employing different configurations in the system's representation. Multiple maxima have also been seen, The present paper identifies the sources of the differences found and compares the relative merits of various theoretical approaches. It introduces the compliance of the system as a figure of merit and provides a simple first-order approximation formula for evaluation of the quality of a system. Damping and impedance matching to improve the system's frequency response were studied. It was found that they were not needed in a very stiff or a very compliant system, nor should one worry about the representation of such a system.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Lactoperoxidase-catalyzed iodination selectively labels the two glycoproteins (VP1 and VP2) of Newcastle disease virus. The low-molecular-weight, nonglycosylated major viral protein, VP6, was not iodinated in the intact virus but was iodinated in disrupted virions, suggesting a localization on the inner, rather than the outer, envelope surface. Studies on the distribution of virion proteins labeled with 125-I and 3-H-isoleucine between detergent-soluble and detergent-insoluble fractions show that the virion proteins VP4, VP5, and VP6 are solubilized to a much lesser extent than are VP1 and VP2.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The effects of wave propagation phenomena, namely global reflection coefficient (gamma G[omega]) and pulse wave velocity (Cph), are studied in a model of the coupled left ventricle/arterial system. The left ventricle consists of a time-varying elastance, while the arterial system is modeled as a single, uniform, elastic tube terminating in a complex load. Manipulation of model parameters allowed for the precise control of gamma G(omega) and Cph independent of each other, peripheral resistance, and characteristic impedance. Reduction of gamma G(omega) and Cph were achieved through increases in load compliance and tube compliance, respectively. The equations describing the system were solved for left ventricular and aortic pressures and aortic flow. From these, stroke volume (SV), left ventricular stroke work (SW), and steady (Ws), oscillatory (Wo), and total power dissipation (Wt) in the arterial system were calculated. An index of arterial system efficiency was the ratio Wo/Wt (%Wo), with lower values indicating higher efficiency. Reduction of gamma G(omega) yielded initial increases in Ws, while Wo increased for the entire range of gamma G(omega), resulting in increased %Wo. This reduced efficiency is imposed on the ventricle, resulting in increased SW without increased SV. On the other hand, decreased Cph yielded in a steady increase in Ws and a biphasic response in Wo, resulting in reduced %Wo for most of the range of reduced Cph. These results suggest that differential effects on arterial system efficiency can result from reductions of gamma G(omega) and Cph. In terms of compliance, changes in arterial compliance can have different effects on efficiency, depending on where the compliance change takes place. Reasons for these results are suggested, and the role of distributed compliances is raised as a new problem.