Search PubMed⌕ Search

Biomedical subjects

J K Han

Publications and source records attributed to J K Han.

At least 145 records · Page 8Linked to original sources

Abdominal cavernous Iymphangiomas: CT findings.

Two adult patients with histopathologically proved cavernous lymphangiomas and one adult patient with lymphangiomas of strongly presumed cavernous type by cytologic and computed tomographic findings are reported. On computed tomograms, multiple, aggregated, small, and tiny cysts without a solid portion, along the lymphatic channels are characteristic computed tomographic findings for cavernous lymphangiomas.

Abdominal Neoplasms↗

Neoplasms containing normal hepatic vessels: imaging features.

BACKGROUND: We investigated the incidence and imaging features of hepatic neoplasms containing normal hepatic vessels. METHODS: Among 3183 patients with various hepatic neoplasms, we found nine patients with normal hepatic vessels traversing hepatic neoplasms. The presence of mass effect on the vessel traversing hepatic neoplasms was evaluated. Other suggestive findings of neoplasms such as altered hepatic contour, portal vein thrombosis, mass effect on extratumoral vessel, and bile duct dilatation were analyzed. RESULTS: Thirteen hepatic vessels (nine hepatic veins and four portal veins) extended through hepatic neoplasms in nine patients. Undisturbed hepatic vessels within the neoplasms were found in five patients with either primary or metastatic hepatic neoplasm. In one patient with undisturbed hepatic vessels within the neoplasm, there were no associated abnormal findings such as biliary dilatation, change of hepatic contour, or any changes involving the vessels external to neoplasms. CONCLUSION: Although rare, various primary and secondary hepatic neoplasms can have normal hepatic vessels passing through them without mass effect. However, correct diagnosis in most neoplasms would be possible with careful examination of associated findings.

Adolescent↗

Preoperative evaluation of Klatskin tumor: accuracy of spiral CT in determining vascular invasion as a sign of unresectability.

BACKGROUND: To assess the accuracy of spiral computed tomography (CT) in predicting the resectability of Klatskin tumor as determined by vascular invasion. METHODS: Twenty-one consecutive patients with Klatskin tumor who had undergone laparotomy were included in this study. The preoperative thin-section (5-mm-thick) spiral CT scans of these patients were assessed for the surgical resectability of tumor by evaluating the vascular invasion. The criterion for vascular invasion indicating unresectability was the tumoral invasion of the proper hepatic artery or main portal vein or simultaneous invasion of one side of the hepatic artery and the other side of the portal vein. RESULTS: All nine patients with tumors thought to be unresectable on the basis of CT findings had tumors that were unresectable at surgery (positive predictive value, 100%). Of 12 patients with tumors thought to be resectable, six had resectable tumors (negative predictive value, 50%). Spiral CT failed to detect small hepatic metastasis (n = 1), lymph node metastasis (n = 1), extensive tumor (n = 2) and variation of bile duct (n = 2), which precluded surgical resection. CONCLUSION: Spiral CT is a reliable method for detecting vascular invasion and unresectable tumors. However, it has limitations in detecting variations of the bile duct or the intraductal extent of tumor.

Adult↗

Quantitative comparison of tumor vascularity of hepatocellular carcinoma after intravenous contrast agent: conventional versus harmonic power Doppler US.

BACKGROUND: The purpose of this study was to make a quantitative comparison between conventional and harmonic power Doppler (PD) ultrasound (US) in depicting vascularity of hepatocellular carcinoma (HCC). METHODS: Ten nodular HCCs in 10 patients were prospectively examined using a 2-4-MHz convex transducer and a standardized examination protocol. Serial US images were obtained before and 20, 30, 40, 50, 60, 90, 120, 150, 180, 240, and 300 s after intravenous injection of 2 g of contrast agent using conventional and harmonic PD US. The percentage of area with Doppler signal within each HCC nodule (%PDA) was calculated in each image with a PC-based image analysis program, and the results with both US techniques were compared. RESULTS: In the majority of cases, %PDA was greater on conventional PD US than on harmonic PD US. Mean %PDA of 10 HCCs was significantly higher on conventional PD US than on harmonic PD US except at 20 s after injection. The highest values of mean %PDA were 34.9% in conventional PD US and 19.5% in harmonic PD US at 60 s after injection. CONCLUSION: Area with PD signals within the HCC is smaller and the duration of effective enhancement is shorter in harmonic PD US than in conventional PD US.

Adult↗

Three-dimensional spiral CT cholangiography with minimum intensity projection in patients with suspected obstructive biliary disease: comparison with percutaneous transhepatic cholangiography.

BACKGROUND: To evaluate the diagnostic potential of spiral computed tomographic (CT) cholangiography with minimum intensity projection (minIP) in the diagnosis of patients with suspected biliary obstruction. METHODS: Nine consecutive patients with obstructive biliary disease were enrolled in this study. Spiral CT data (3-mm slice thickness, pitch 1-2:1) obtained 65 s after the start of contrast medium injection (150 mL Ultravist 370, 3 mL/s) were reconstructed at 1-mm intervals. Three-dimensional (3D) CT cholangiography with minIP (3D CTC) was generated with a Siemens software package. The quality of 3D CTC in its ability to demonstrate the anatomic detail, the level of obstruction, and the presence or absence of isolated hepatic segments was evaluated using percutaneous transhepatic cholangiography as a gold standard. RESULTS: In all patients, 3D CTC demonstrated dilated intrahepatic ducts up to tertiary branches. 3D CTC correctly diagnosed the level of biliary obstruction and demonstrated isolated segments in all patients. In determining the cause of biliary obstruction, one patient with hilar cholangiocarcinoma was misdiagnosed as having biliary invasion by hepatocellular carcinoma. CONCLUSION: 3D CTC with minIP can determine the level and cause of biliary obstruction. 3D CTC can be obtained from regular thin-section helical CT data and may be a strong competitor against diagnostic magnetic resonance cholangiography because of its superior resolution and information on adjacent soft tissues and the duct itself.

Aged↗

Isolated bladder metastases from stomach cancer: CT demonstration.

Isolated metastatic tumors of the urinary bladder are extremely rare. We report three cases of isolated bladder metastasis from stomach cancer, which were proved at transurethral biopsy or total cystectomy. The lesions appeared as focal or diffuse thickening of the bladder wall on computed tomography. No other metastatic lesion was detected on imaging studies, which made the diagnosis of bladder metastasis difficult. The possibility of metastatic bladder tumor should be considered when the bladder wall is thickened focally or diffusely in a patient treated with stomach cancer.

Diagnosis, Differential↗

Focal hepatic nodules after transcatheter oily chemoembolization; detection with spiral CT versus conventional CT.

BACKGROUND: The objective of this study was to determine if spiral computed tomography (CT) results in increased rate of detection of focal hepatic nodules containing iodized oil after transcatheter oily chemoembolization when compared with conventional CT. METHODS: Spiral CT with single 24-s breath-hold technique was compared with conventional sequential CT in 42 patients with suspected hepatocellular carcinomas. Two sets of CT scans obtained after transcatheter oily chemoembolization were independently reviewed by two radiologists. The slice thickness was 10 mm for both data sets. The number and sizes of focal hepatic nodules containing iodized oil were documented. All 42 patients had at least hepatic nodule. The lesion size varied from 2 mm to 12 cm. RESULTS: In six of the 42 patients, more hepatic nodules could be identified on spiral CT compared with conventional CT. When scans with spiral CT were used, 107 nodules were detected, whereas 98 nodules were detected with conventional CT. Overall, nine (9%) more nodules were detected with spiral CT (p = .002). If lesions larger than 2 cm are excluded, nine (15%) more lesions were detected with spiral CT (p = .002). CONCLUSION: Spiral CT results in increased rate of detection of focal hepatic nodules after transcatheter oily chemoembolization, particularly in lesions smaller than 2 cm.

Antibiotics, Antineoplastic↗

Iodized-oil retention within hepatic hemangioma: characteristics on iodized-oil CT.

OBJECTIVE: The purpose of this study was to describe the characteristic computed tomographic (CT) appearance of iodized-oil retention in hepatic hemangioma and to evaluate the duration of the retention of iodized oil on follow-up CT. METHODS: Seventeen hepatic hemangiomas of 14 patients were studied with CT performed 1-3 weeks after injection of 2-9 ml of iodized oil (iodized-oil CT) for the characterization of focal hepatic lesions, which needed differential diagnosis with hepatocellular carcinoma in 10 patients, for therapy in two patients, and for chemoembolization therapy of accompanying hepatocellular carcinomas in two. Twelve patients had 1-7 follow-up CT scans within an interval of 1-38 months. RESULTS: In all cases, iodized-oil CT showed iodized-oil retention within the tumor, regardless of tumor size, shape, location, and amount of injected iodized oil. The distribution was incomplete and predominantly peripheral in all cases. Central retention was also seen in seven cases, in which a relatively large amount of iodized oil was injected, but retention of iodized oil in the tumor was incomplete even in two cases in which a large amount of iodized oil was injected to relieve symptoms and in three cases in which prominent uptake of surrounding liver parenchyma was seen. Patterns of retention were predominantly spotty in five, predominantly nodular in four, and mixed in eight patients. Retention materials slowly washed out but persisted for at least 3 months and up to 38 months (mean = 18.1 months), and complete washout was not seen in any cases at follow-up CT. CONCLUSION: In all cases of hepatic hemangiomas, iodized oil was retained, and retention persisted over several months. Distribution and patterns of retention were characteristically peripheral, spotty, and nodular at iodized-oil CT. Knowledge of the iodized-oil CT appearance of hepatic hemangioma would be helpful to interpret follow-up CT studies of patients who have undergone iodized-oil chemoembolization procedures.

Adult↗

Spiral CT for the detection of hepatocellular carcinomas:relative value of arterial- and late-phase scanning.

BACKGROUND: Spiral computed tomography (CT) can image the liver during arterial and late phases of contrast and optimize the evaluation of hypervascular tumor. The objective of this study was to evaluate the relative value of arterial- and late-phase spiral CT in the detection of hepatocellular carcinomas. METHODS: Fifty-eight patients with hepatocellular carcinomas underwent two-phase spiral CT examination with 10-mm collimation at 10 mm/s table speed (Siemens Somatom Plus S), and 120 mL of contrast material (36 g iodine) was injected at the rate of 3 mL/s. CT images of hepatic arterial and late phases were obtained with a 35-s and 180-s delay, respectively. RESULTS: In 58 patients, 111 hepatocellular carcinoma lesions were seen. The arterial phase detected 93 (84%) and the late phase 75 (68%) lesions (p < 0.01). The arterial phase detected more lesions in 11 patients, and the late phase detected more in two patients and an equal number in 45 patients. If lesions larger than 2 cm are excluded, the arterial phase detected 40 (74%) and the late phase 21 (39%) of 54 lesions (p < 0.001). CONCLUSION: The arterial phase of spiral CT greatly improves the detection of hepatocellular carcinoma when compared with the late phase.

Adult↗

Helical CT anatomy of pancreatic arteries.

BACKGROUND: To assess the frequency of visualization of pancreatic arteries in the arterial phase of helical computed tomography (CT). METHODS: The visibility of pancreatic and peripancreatic arteries in helical CT images was evaluated in 20 consecutive patients who had no evidence of pancreatic disease. CT examinations were performed by using a continuously rotating CT scanner and intravenous injection of contrast media. The scans were taken 35 s after the start of injection and with a table speed of 3 mm/s. Images were reconstructed in 3-mm section increments. RESULTS: Frequently visualized arteries were the gastroduodenal, anterior and posterior superior pancreaticoduodenal, and right gastroepiploic arteries. Infrequently visualized arteries were the dorsal pancreatic, pancreatica magna, caudal pancreatic, transverse pancreatic, and common, anterior, and posterior inferior pancreaticoduodenal arteries. CONCLUSION: Helical CT enabled us to recognize small pancreatic arteries, and the evaluation of these arteries should be considered in the staging of pancreatic carcinoma.

Arteries↗

Detection of pancreatic adenocarcinoma: relative value of arterial and late phases of spiral CT.

BACKGROUND: Spiral computed tomography (CT) allows the pancreas to be imaged during peak contrast levels owing to the capability of fast data acquisition. The objective of this study was to evaluate the relative value of the arterial and late phases of spiral CT for detecting pancreatic adenocarcinomas. METHODS: Twenty-two patients with pathologically proved pancreatic adenocarcinomas underwent two-phase spiral CT. The CT scans were performed with 5 mm collimation and 5 mm/s table speed. Images during the arterial and late phases were obtained at 30- and 180-second delays, respectively. The images of the arterial phase were compared with those of the late phase in terms of tumor conspicuity from surrounding pancreatic parenchyma and tumor detectability by means of a 3-point grading system: 1 (poor), 2 (fair), and 3 (good). RESULTS: In terms of tumor conspicuity from surrounding pancreatic parenchyma, 16 lesions (73%) were good, 5 lesions (23%) were fair, and 1 lesion (4%) was poor during the arterial phase, whereas 6 lesions (27%) were good, 9 lesions (41%) were fair, and 7 lesions (32%) were poor during the late phase (p = 0.0007). The arterial phase was superior to the late phase in 16 patients (73%) and equal in 6 patients (27%). For tumor detectability, 18 lesions (82%) were good, 3 lesions (14%) were fair, and 1 lesion (4%) was poor during the arterial phase, whereas 10 lesions (45%) were good, 7 lesions (32%) were fair, and 5 lesions (23%) were poor during the late phase (p = 0.0033). For detectability, the arterial phase was superior to the late phase in 14 patients (64%) and equal in 8 patients (36%). CONCLUSION: The arterial phase of spiral CT is superior to the late phase, which is equivalent to conventional CT for detecting pancreatic adenocarcinoma.

Adenocarcinoma↗

MR cholangiopancreatography: comparison between half-Fourier acquisition single-shot turbo spin-echo and two-dimensional turbo spin-echo pulse sequences.

BACKGROUND: To compare half-Fourier acquisition single-shot turbo spin-echo spin-echo (HASTE) magnetic resonance cholangiopancreatography (MRCP) with two-dimensional turbo spin-echo (2D TSE) MRCP for imaging pancreatobiliary diseases. METHODS: Twenty-seven patients with biliary or pancreatic disease underwent MRCP on a 1.0-T scanner with a body phased-array coil. A T2-weighted HASTE sequence (18 s) and a T2-weighted 2D TSE sequence (45 s) were used during a breath-hold by the patient. The source images and maximum intensity projection images of both sequences were reviewed independently by two radiologists. RESULTS: Motion artifacts were more severely pronounced with 2D TSE sequences than with HASTE sequences (p < 0.001). All obstructions and their sites were accurately identified with both sequences. Filling defects (calculi) in bile ducts were identified in all 22 segments (100%) with HASTE-MRCP, whereas calculi in 19 of 22 segments (86%) were identified with 2D TSE-MRCP (p = 0.25). Three missed sites on 2D TSE-MRCP were intrahepatic bile ducts. CONCLUSIONS: HASTE-MRCP is superior to 2D TSE-MRCP in terms of detecting motion artifacts and visualization of the pancreatic ducts. HASTE-MRCP is comparable to 2D TSE-MRCP for visualization of the biliary ducts and their obstruction and is superior to 2D TSE-MRCP for identification of calculi in intrahepatic bile ducts.

Adult↗

T2-weighted MR imaging for hepatic hemangiomas: comparison of breath-hold and non-breath-hold turbo spin-echo pulse sequences with phased-array multicoil.

BACKGROUND: We compared T2-weighted and heavily T2-weighted breath-hold turbo spin-echo (TSE) sequences with T2-weighted non-breath-hold TSE sequence to evaluate hepatic hemangiomas on magnetic resonance (MR) with a phased-array multicoil. METHODS: Twenty-two patients with 27 hemangiomas were studied at 1.0-T scanner by using T2-weighted and heavily T2-weighted breath-hold TSE sequences (18 s each) and non-breath-hold T2-weighted TSE sequences with use of a phased-array multicoil. Images were quantitatively analyzed for tumor-to-liver signal-difference-to-noise ratios (SD/Ns) and tumor-to-liver signal intensity ratios (T/Ls) and qualitatively analyzed for tumor conspicuity and motion-induced image artifacts. RESULTS: Quantitatively, T2-weighted breath-hold TSE images showed the highest SD/Ns among the three sequences, although the differences from the heavily T2-weighted breath-hold TSE sequence and the T2-weighted non-breath-hold TSE sequence were not statistically significant (p = 0.61 and 0.06, respectively). Heavily T2-weighted breath-hold TSE images showed the highest T/Ls among the three sequences. The differences from the T2-weighted breath-hold TSE sequence and the T2-weighted non-breath-hold TSE sequence were statistically significant (p < 0.001). Qualitatively, breath-hold TSE images were superior to non-breath-hold TSE images in terms of tumor conspicuity (p < 0.01) and motion artifacts (p < 0.01). CONCLUSION: T2-weighted breath-hold TSE sequence is superior to T2-weighted non-breath-hold TSE sequence in the evaluation of hepatic hemangiomas on MR with a phased-array multicoil.

Adult↗

Cytomegalovirus proctitis in a diabetic.

We describe an unusual case of cytomegalovirus (CMV) proctitis in an elderly adult with uncontrolled diabetes mellitus, who had not received immunosuppressive therapy. Barium study and computed tomography showed large ulceration and sinus tract involving the rectum. CMV colitis is thought to occur almost exclusively in immunosuppressed persons. In a nonimmunosuppressed host, the infection is rarely reported.

Cytomegalovirus Infections↗

Dysplastic nodules of the liver: imaging findings.

BACKGROUND: To verify characteristic features of hepatic dysplastic nodules at different imaging modalities. METHODS: Twenty-eight patients with 37 dysplastic nodules of the liver (0.8-3.0 cm) underwent sonography (28 patients), computed tomography (CT; 24 patients), magnetic resonance (MR; 11 patients), and angiography (12 patients). Each nodule was analyzed for echogenicity, attenuation, signal intensity, and vascularity. RESULTS: Echogenicity of nodules was high in 16 (43%), homogeneous in two (6%), and low in 19 (51%) of 37 nodules. Attenuation of nodules was high in one (7%), homogeneous in four (26%), and low in 10 (67%) of 15 nodules on the arterial-phase CT images; homogeneous in five (33%) and low in 10 (67%) of 15 nodules on the portal-phase CT images; and high in four (17%), homogeneous in six (26%), and low in 13 (57%) of 23 nodules on the delayed-phase CT images. Signal intensity of nodules was high in 15 (94%) and homogeneous in one (6%) of 16 nodules on T1-weighted MR images and was homogeneous in seven (44%) and low in nine (56%) of 16 nodules on T2-weighted MR images. Vascularity of nodules was avascular in 14 (88%) and slightly vascular in two (12%) of 16 nodules. CONCLUSIONS: Hepatic dysplastic nodules show diverse imaging characteristics with different imaging techniques; however, common imaging findings of hepatic dysplastic nodules are low echo, low attenuation, and high, low, or homogeneous intensity on T1- and T2-weighted MR, and avascularity.

Adult↗

Hepatic hemangioma: contrast-enhancement pattern during the arterial and portal venous phases of spiral CT.

The objective of the present study was to evaluate contrast-enhancement patterns of hepatic hemangioma according to size during hepatic arterial (30-s delay) and portal venous (65-s delay) phases of spiral computed tomography (CT). During a 10-month-period, 73 patients with 118 hemangiomas underwent two-phase spiral CT examination. The enhancement patterns of tumors were divided into four types based on the attenuation of surrounding liver parenchyma: peripherally nodular high, uniform high, iso, and low. The diameter of the tumors were <10 mm (n = 39), 11-20 mm (n = 33), and >21 mm (n = 46). Overall, the most common enhancement patterns of hemangioma were peripherally nodular high (66/118, 55. 9%) during the arterial and portal venous phases. The second most common contrast-enhancement patterns of hemangioma were uniform high (15/118, 12.7%) during the arterial and portal venous phases. In tumors smaller than 20 mm, 11 (9.3%) had low-low attenuation and two (1.7%) had iso-low attenuation during the arterial and portal venous phases, respectively. In conclusion, at two-phase spiral CT, the most common contrast-enhancement patterns of hemangioma are peripherally nodular high and/or uniform high during the arterial and portal venous phases. However, hemangiomas smaller than 2 cm may have atypical enhancing patterns including low and iso-attenuation.

Adult↗