Search PubMed⌕ Search

Biomedical subjects

J K Han

Publications and source records attributed to J K Han.

173 records · Page 10Linked to original sources

Nodular hepatocellular carcinoma: variation of tumor conspicuity on single-level dynamic scan and optimization of fixed delay times for two-phase helical CT.

PURPOSE: The purpose of this work was to determine the optimal delay times in two-phase helical CT for nodular hepatocellular carcinoma (HCC). METHOD: Twenty-four patients with nodular HCC (size 2.1-6.7 cm, mean 4.2 cm) were divided into three groups to undergo single-level dynamic CT with 150 ml of contrast material (iodine load of 45 g) at a rate of 3 ml/s. CT acquisition started 10, 30, or 60 s after the injection for each group, respectively, and lasted for 110 or 120 s. The optimal 20 s windows that allowed a tumor-to-liver contrast of >10 HU were determined in the pooled tumor-to-liver contrast curve. RESULTS: The determined temporal windows were 36-56 and 130-150 s, respectively. However, each window was not appropriate in seven (33%) and five (36%) patients because of the individual variations of the contrast curve. CONCLUSION: There is no optimal fixed delay time that is appropriate in all individual patients. The best delay times are 36 and at least 130 s with our injection protocol.

Adult↗

MRI in staging advanced gastric cancer: is it useful compared with spiral CT?

PURPOSE: During the last decade, rapid progress has been made in MR technology. Our objective was to evaluate the role of MRI in staging advanced gastric cancer (AGC; gastric cancer invading the muscularis propria) and to compare it with that of spiral CT. METHOD: We prospectively performed both MR and CT examinations on 26 patients with AGC proven by endoscopic biopsy. Contrast-enhanced CT and nonenhanced MRI with a 1.0 T scanner using FLASH, HASTE, and true-FISP sequences were obtained in each patient after injection of antiperistaltic drug and ingestion of 1 L of tap water. Fifty-two sets of CT and MR images were analyzed by two radiologists in consensus without any information from other images. T and N staging of AGC was determined according to the TNM classification. All patients underwent surgery within 1 week after both examinations. Diagnostic accuracy of each staging of AGC on CT or MRI was evaluated by comparison with the pathologic results. RESULTS: MRI was slightly superior to CT in T staging (81 vs. 73%, respectively; p < 0.05). Although MRI had a tendency to overstage the pathologic T2 cancer, positive predictability of T2 stage and sensitivity of T3 stage were high (100%, respectively). Regarding the N staging, CT was slightly superior to MRI (73 vs. 65%; p > 0.05). However, both CT and MRI demonstrated the tendency of understaging in N staging. CONCLUSION: Although MRI was superior to spiral CT in T staging, MRI cannot completely replace spiral CT in staging AGC because of its limitation in N staging.

Adult↗

Factors influencing vascular and hepatic enhancement at CT: experimental study on injection protocol using a canine model.

PURPOSE: The purpose of this work was to evaluate the effects of contrast medium injection parameters on aortic, portal vein, and hepatic enhancement at spiral CT and to assess optimal injection protocol for hepatic CT. METHOD: Ten 15 kg dogs underwent single level dynamic CT through the hepatic hilum at 5 s intervals just after the injection of contrast medium for 3 min. With use of different volumes (1, 2, and 3 ml/kg), injection rates (0.5, 1, and 2 ml/s), and concentrations (150, 200, and 300 mg/ml), a total of 270 spiral CT scans were performed. In each scan, time-attenuation curves of aorta, portal vein, and liver were obtained. The degree of maximum contrast enhancement (Imax), time to maximum enhancement (Tmax), and time to equilibrium phase (Teq) for to each injection protocol were analyzed. RESULTS: Alterations in contrast material volume, injection rate, and concentration had significant impact on contrast enhancement of the liver. With increasing volume of contrast medium, Imax, Tmax, and Teq of aorta, portal vein, and liver increased (p < 0.005). With increasing rate of injection, on the other hand, Imax of aorta and liver increased (p < 0.05), but Tmax and Teq decreased (p < 0.005). Change of concentration of contrast medium had a significant effect on Imax of vessels (p < 0.05). CONCLUSION: Maximum contrast enhancement of liver and vessels was influenced mainly by injection volume of contrast medium and the time to peak enhancement by injection rate of contrast medium. Under given amounts of contrast medium, therefore, the strategy of increasing volume by dilution and faster injection might give better Imax values without penalty for the duration of an optimal temporal window (Tmax and Teq).

Animals↗

Fat replacement with absence of acinar and ductal structure in the pancreatic body and tail.

We report an unusual case of fat replacement of the pancreatic body and tail. Findings on contrast-enhanced computed tomography and ERCP could be confused with dorsal pancreas agenesis. Histopathologic examination of the resected specimen revealed massive fat replacement with complete absence of the acinar and ductal tissue and scattered islets of Langerhans.

Adipose Tissue↗

Castleman disease of the abdomen: imaging spectrum and clinicopathologic correlations.

PURPOSE: The purpose of this work was to define the imaging spectrum of Castleman disease of the abdomen and to correlate the results with clinicopathologic findings. METHOD: Seventeen patients (male/female 7:10; mean age 35.6 years) with pathologically proved Castleman disease in the abdomen were included in this study. Radiologic findings (CT, n =17; US, n =10; MR, n =1) were retrospectively reviewed by two readers and were correlated with clinical and pathologic findings. RESULTS: Subjects were divided into those with localized (n = 11) and disseminated (n = 6) disease. In localized disease, the pathologic subtypes were hyaline vascular type in eight and plasma cell type in three. Radiologic studies showed a single large mass in six and a single dominant mass with small satellite nodules in five. Central low attenuation was seen in two cases, and calcification was seen in three cases. Regional lymphadenopathy was found in five cases. In disseminated disease, there were three hyaline vascular types and three plasma cell types. Radiologic findings included diffuse lymphadenopathy (n = 6), hepatosplenomegaly (n = 5), ascites (n = 3), and thickening of the retroperitoneal fascia (n = 3). Disseminated disease revealed symptoms and abnormal laboratory findings (anemia, hypoalbuminemia, elevated erythrocyte sedimentation rate/C-reactive protein, etc.) more frequently than localized disease and showed poor prognosis. CONCLUSION: There are two distinctive types of radiologic manifestations in Castleman disease of the abdomen: localized and disseminated. The localized type usually shows single or multiple discrete masses, and the disseminated type frequently shows nonspecific organomegaly and lymphadenopathy.

Abdomen↗

Hilar cholangiocarcinoma: thin-section spiral CT findings with cholangiographic correlation.

Hilar cholangiocarcinoma, a highly lethal tumor, is difficult to diagnose with conventional computed tomography (CT) because of its small size. Spiral CT allows more effective evaluation of these small lesions and better demonstrates the status of the hepatic arterial or portal venous circulation. Among 27 patients with hilar cholangiocarcinoma (infiltrative in 21, exophytic in two, polypoid in one, diffuse in three), thin-section spiral CT allowed identification of each tumor as an area of focal wall thickening that obliterated the lumen. Seventeen of the infiltrative tumors (81%) showed high attenuation. Identification of the level of biliary obstruction was possible in 63% of the patients (17 of 27). The level of obstruction was underestimated in six patients and overestimated in four. Spiral CT is a valuable method for diagnosis of hilar cholangiocarcinoma; however, spiral CT is less accurate in evaluation of intraductal tumor extent because of the limited z-axis resolution.

Adult↗

Unusual gastric tumors: radiologic-pathologic correlation.

The overlap of radiologic findings in many gastric tumors makes differentiation difficult. However, some unusual gastric tumors have characteristic radiologic features that may suggest a specific diagnosis. At barium study, lipomas typically manifest as a smooth submucosal mass or an ulcerated lesion with a "bull's-eye" appearance that is indistinguishable from other mesenchymal tumors. At computed tomography (CT), lipomas usually manifest as well-circumscribed submucosal masses with fat attenuation. At radiology, glomus tumors appear as smooth submucosal masses with or without ulceration and may contain tiny flecks of calcification. These tumors frequently demonstrate strong enhancement on early-phase contrast material-enhanced images. At barium study, lymphangiomas may appear as smooth intramural masses that are indistinguishable from other mesenchymal tumors. At CT, they manifest as non-enhancing extramucosal masses with homogeneous low attenuation. Diffuse lesions in Brunner gland hamartoma manifest as multiple small nodules, producing a characteristic "cobblestone" appearance. Lymphomas may have typical imaging features (eg, more pronounced and homogeneous mural thickening) that can help differentiate them from adenocarcinoma. In addition, adenocarcinomas may demonstrate unusual findings such as transpyloric spread, unusually large polyps, or intratumoral calcifications. Familiarity with these radiologic features of gastric tumors can help ensure correct diagnosis and proper management.

Adenocarcinoma↗

Gastric mucosa-associated lymphoid tissue lymphoma: spectrum of findings at double-contrast gastrointestinal examination with pathologic correlation.

Mucosa-associated lymphoid tissue (MALT) is found in the surface epithelium of the stomach. MALT lymphoma is extranodal lymphoma originating from MALT. In the stomach, a strong association with Helicobacter pylori infection has been demonstrated. Low-grade gastric MALT lymphoma has been reported to have variable features at upper gastrointestinal (UGI) examination. Twenty-two patients with low-grade MALT lymphoma had ulcers (n = 11), fold thickening (n = 7), mucosal nodularity (n = 7), masses (n = 6), or prominent areae gastricae (n = 4) at UGI examination. Six patients with high-grade MALT lymphoma had masses (n = 4), fold thickening (n = 3), ulcers (n = 1), or mucosal nodularity (n = 1) at UGI examination. These findings were similar to those in gastric carcinoma or gastritis. Differentiation of low-grade MALT lymphoma from gastritis or gastric carcinoma was more difficult than differentiation of high-grade MALT lymphoma. Lesions of MALT lymphoma associated with H pylori gastritis were diffuse or multiple in 65% of cases; however, lesions of MALT lymphoma without proved H pylori gastritis were focal or solitary in 80% of cases. Therefore, multiplicity of lesions in MALT lymphoma was closely associated with H pylori infection.

Adult↗

Hepatic hemangiomas: spectrum of US appearances on gray-scale, power Doppler, and contrast-enhanced US.

Because US plays a key role in the initial evaluation of hepatic hemangiomas, knowledge of the entire spectrum of US appearances of these tumors is important. Most hemangiomas have a distinctive US appearance, and even with those with atypical appearances on conventional gray-scale US, specific diagnoses can be made using pulse-inversion harmonic US with contrast agents. In this essay, we review the spectrum of US appearances of hepatic hemangiomas on conventional gray-scale, power Doppler, and pulse-inversion harmonic US with contrast agents.

Adult↗

Contrast media in abdominal computed tomography: optimization of delivery methods.

OBJECTIVE: To provide a systematic overview of the effects of various parameters on contrast enhancement within the same population, an animal experiment as well as a computer-aided simulation study was performed. MATERIALS AND METHODS: In an animal experiment, single-level dynamic CT through the liver was performed at 5-second intervals just after the injection of contrast medium for 3 minutes. Combinations of three different amounts (1, 2, 3 mL/kg), concentrations (150, 200, 300 mgI/mL), and injection rates (0.5, 1, 2 mL/sec) were used. The CT number of the aorta (A), portal vein (P) and liver (L) was measured in each image, and time-attenuation curves for A, P and L were thus obtained. The degree of maximum enhancement (Imax) and time to reach peak enhancement (Tmax) of A, P and L were determined, and times to equilibrium (Teq) were analyzed. In the computed-aided simulation model, a program based on the amount, flow, and diffusion coefficient of body fluid in various compartments of the human body was designed. The input variables were the concentrations, volumes and injection rates of the contrast media used. The program generated the time-attenuation curves of A, P and L, as well as liver-to-hepatocellular carcinoma (HCC) contrast curves. On each curve, we calculated and plotted the optimal temporal window (time period above the lower threshold, which in this experiment was 10 Hounsfield units), the total area under the curve above the lower threshold, and the area within the optimal range. RESULTS: A. Animal Experiment: At a given concentration and injection rate, an increased volume of contrast medium led to increases in Imax A, P and L. In addition, Tmax A, P, L and Teq were prolonged in parallel with increases in injection time The time-attenuation curve shifted upward and to the right. For a given volume and injection rate, an increased concentration of contrast medium increased the degree of aortic, portal and hepatic enhancement, though Tmax A, P and L remained the same. The time-attenuation curve shifted upward. For a given volume and concentration of contrast medium, changes in the injection rate had a prominent effect on aortic enhancement, and that of the portal vein and hepatic parenchyma also showed some increase, though the effect was less prominent. A increased in the rate of contrast injection led to shifting of the time enhancement curve to the left and upward. B. Computer Simulation: At a faster injection rate, there was minimal change in the degree of hepatic attenuation, though the duration of the optimal temporal window decreased. The area between 10 and 30 HU was greatest when contrast media was delivered at a rate of 2-3 mL/sec. Although the total area under the curve increased in proportion to the injection rate, most of this increase was above the upper threshold and thus the temporal window was narrow and the optimal area decreased. CONCLUSION: Increases in volume, concentration and injection rate all resulted in improved arterial enhancement. If cost was disregarded, increasing the injection volume was the most reliable way of obtaining good quality enhancement. The optimal way of delivering a given amount of contrast medium can be calculated using a computer-based mathematical model.

Animals↗

Unilateral absence of lung perfusion on pulmonary scintigraphy secondary to lung cancer with extensive pleural metastases from lung cancer.

A man with a 20-year history of smoking who underwent Tc-99m MAA Pulmonary perfusion imaging, which showed virtually absent perfusion of the right lung and fairly normal perfusion of the left lung. Eighteen days after the study, the patient died; at autopsy poorly differentiated carcinoma of the right lung was confirmed, which included extensive thickened pleura and plaques deposits and compression of the right lung; 200 ml of bloody pleural effusion was also found on the right side. The unilateral absence of lung perfusion on Tc-99m MAA pulmonary scintigraphy might reflect the autopsy findings of the right lung and pleura.

Aged↗