Pressure/volume curves and lung computed tomography in acute respiratory distress syndrome.

Pressure/volume (P/V) curves can be measured by static methods, constant or sinusoidal flow methods and the dynostatic method that allows a breath-to-breath determination of P/V curves. Recent ventilators are equipped with specific flow generators and software aimed at obtaining P/V curves without disconnecting the patient from the ventilator. The most recent generation of computed tomography scanners allows the quantitative determination of lung aeration, lung volumes (gas and tissue), alveolar recruitment and lung overinflation of the whole lung. In the supine position, the acute respiratory distress syndrome (ARDS) lung is characterised by an increase in lung tissue that predominates in upper lobes and a massive loss of aeration that predominates in lower lobes. In a minority of ARDS patients, the loss of aeration is homogeneously distributed. The overall lung volume of upper lobes is preserved suggesting an alveolar flooding-induced loss of aeration. In contrast, the overall lung volume of lower lobes is reduced because the heart and the abdomen exert an external compression that contributes to the loss of aeration. The P/V curve is a lung recruitment curve and the chord compliance indicates the potential for recruitment. In such patients, alveolar recruitment resulting from positive end-expiratory pressure is not accompanied by lung overinflation. In a majority of acute respiratory distress syndrome patients, upper lobes remain partially or totally aerated despite a marked regional increase in lung tissue. The upper lobes' overall lung volume is either normal or increased, suggesting that the lung does not collapse under its own weight as generally believed. In lower lobes, the overall lung volume is reduced because the heart and the abdomen exert an external compression that contributes to the loss of aeration. The pressure/volume curve is influenced by the recruitment of poorly and nonaerated lung regions and by the mechanical properties of the part of the lung remaining aerated. In such patients, alveolar recruitment resulting from positive end-expiratory pressure >10 cmH2O is preceded and accompanied by lung overinflation.

Humans↗

Validation of a software designed for computed tomographic (CT) measurement of lung water.

OBJECTIVE: The in-vitro validation of a computed tomographic (CT) software specifically designed for quantifying the volume of water contained in the lung. DESIGN: An in-vitro, ex-vivo study. In 1993, a postmortem left pneumonectomy was performed in a patient who died from acute respiratory distress syndrome. The lung was fixed, inflated and dried according to a technique proposed by Markarian and Dailey in 1975 aimed at producing a lung specimen spongy in texture and suitable for radiography. MEASUREMENTS AND RESULTS: In 1999, 13 CT scans of this lung specimen were performed corresponding to different bronchial instillations of known volumes of water and albumin 4%. The different lung weights resulting from the successive bronchial instillations were calculated using a specially designed software, Lungview, adapted for CT measurements and compared with the actual lung weight measured by an electronic scale. The increase in lung weight measured by Lungview was closely correlated with the actual increase in lung weight resulting from bronchial instillation of water and albumin (y = 0.99x - 23, r = 1 for water and y = x - 17, r = 1 for albumin 4%) and the precision of the bias was 7 g for water and 3 g for albumin 4%. CONCLUSIONS: This study shows that the CT software Lungview accurately measured the volume of lung water present within an air-dried exsanguine human lung.

Aged↗

Assessment of PEEP-induced reopening of collapsed lung regions in acute lung injury: are one or three CT sections representative of the entire lung?

OBJECTIVES: To study whether PEEP-induced reopening of collapsed lung regions--defined as the decrease in nonaerated lung volume measured on a single or three computerized tomographic (CT) sections--is representative of the decrease in overall nonaerated lung volume. DESIGN: Review of 39 CT scans obtained in consecutive patients with Acute Lung Injury. SETTINGS: Fourteen-bed surgical intensive care unit of a University Hospital. MEASUREMENTS AND RESULTS: PEEP-induced decrease in nonaerated lung volume was measured in 39 patients with ALI on a single juxtadiaphragmatic CT section, on three CT sections--apical, hilar, and juxtadiaphragmatic--and on contiguous apex-to-diaphragm CT sections. The percentage of decrease in nonaerated lung volume following PEEP, was compared between one, three and all CT sections using a linear regression analysis and Bland and Altman's method. The decrease in nonaerated lung volume measured on a single and three CT sections was significantly correlated with the decrease in nonaerated lung volume measured on all CT sections: R=0.83, P<0.0001 for one CT section and R=0.92, P<0.0001 for three CT sections. However, measurements performed on a single CT section were poorly representative of the overall lung: bias -6%, limits of agreement ranging between -37% and +25%. Measurements performed on three CT sections overestimated by 11% the overall decrease in nonaerated lung volume: bias -11%, limits of agreement ranging between -29% and +7%. CONCLUSIONS: PEEP-induced reopening of collapsed lung regions measured on a single or three CT sections sensibly differs from the reopening of collapsed lung regions measured on the overall lung. The inhomogeneous distribution of PEEP-induced reopening of collapsed lung regions along the cephalocaudal axis probably explains these discrepancies.

Adult↗

Mechanical ventilation-induced air-space enlargement during experimental pneumonia in piglets.

Mechanical ventilation-induced air-space enlargement was investigated in a porcine model of multifocal pneumonia. Following the intrabronchial inoculation of Escherichia coli, 9 piglets (22 +/- 2 kg) were ventilated with a tidal volume (VT) of 15 ml/kg for 43 +/- 15 h. Five noninoculated piglets ventilated for 60 h with the same VT served as control animals. Following death, the lungs were fixed and lung morphometry was assessed. In inoculated animals, unventilated infected and normally ventilated noninfected pulmonary lobules coexisted. In normally ventilated lung regions (1) emphysema-like lesions were present, (2) mean alveolar area and mean linear intercept were significantly greater in inoculated than in control animals, and (3) the degree of alveolar distension correlated with the decrease in respiratory compliance. In unventilated lung areas (1) pseudocysts were frequent, (2) alveolar edema was rare, (3) bronchiolectasis was frequent, (4) mean bronchiolar area was greater in inoculated than in control animals, and (5) the degree of bronchiolar distension correlated with the increase in inspiratory plateau pressure. In conclusion, in piglets with severe bronchopneumonia, air-space enlargement rather than pulmonary edema was the major feature of mechanical ventilation-induced lung barotrauma and resembled lesions previously reported in critically ill patients ventilated using high inspiratory pressures.

Analysis of Variance↗

Computed tomography assessment of positive end-expiratory pressure-induced alveolar recruitment in patients with acute respiratory distress syndrome.

Computed tomography (CT) assessment of positive end-expiratory pressure (PEEP)-induced alveolar recruitment is classically achieved by quantifying the decrease in nonaerated lung parenchyma on a single juxtadiaphragmatic section (Gattinoni's method). This approach ignores the alveolar recruitment occurring in poorly aerated lung areas and may not reflect the alveolar recruitment of the entire lung. This study describes a new CT method in which PEEP-induced alveolar recruitment is computed as the volume of gas penetrating in poorly and nonaerated lung regions following PEEP. In 16 patients with acute respiratory distress syndrome a thoracic spiral CT scan was performed in ZEEP and PEEP 15 cm H(2)O. According to the new method, PEEP induced a 119% increase in functional residual capacity (FRC). PEEP-induced alveolar recruitment was 499 +/- 279 ml whereas distension and overdistension of previously aerated lung areas were 395 +/- 382 ml and 28 +/- 6 ml, respectively. The alveolar recruitment according to Gattinoni's method was 26 +/- 24 g and no correlation was found between both methods. A significant correlation was found between PEEP-induced alveolar recruitment and increase in Pa(O(2)) only when recruitment was assessed by the new method (Rho = 0.76, p = 0.003), suggesting that it may be more accurate than Gattinoni's method.

Aged↗

Measurement of pressure-volume curves in patients on mechanical ventilation: methods and significance.

Physiological background concerning mechanics of the respiratory system, techniques of measurement and clinical implications of pressure-volume curve measurement in mechanically ventilated patients are discussed in the present review. The significance of lower and upper inflection points, the assessment of positive end-expiratory pressure (PEEP)-induced alveolar recruitment and overdistension and rationale for optimizing ventilatory settings in patients with acute lung injury are presented. Evidence suggests that the continuous flow method is a simple and reliable technique for measuring pressure-volume curves at the bedside. In patients with acute respiratory failure, determination of lower and upper inflection points and measurement of respiratory compliance should become a part of the routine assessment of lung injury severity, allowing a bedside monitoring of the evolution of the lung disease and an optimization of mechanical ventilation.

Critical Care↗

Regional distribution of gas and tissue in acute respiratory distress syndrome. I. Consequences for lung morphology. CT Scan ARDS Study Group.

OBJECTIVE: To compare the computed tomographic (CT) analysis of the distribution of gas and tissue in the lungs of patients with ARDS with that in healthy volunteers. DESIGN: Prospective study over a 53-month period. SETTING: Fourteen-bed surgical intensive care unit of a university hospital. PATIENTS AND PARTICIPANTS: Seventy-one consecutive patients with early ARDS and 11 healthy volunteers. MEASUREMENTS AND RESULTS: A lung CT was performed at end-expiration in patients with ARDS (at zero PEEP) and healthy volunteers. In patients with ARDS, end-expiratory lung volume (gas + tissue) and functional residual capacity (FRC) were reduced by 17% and 58% respectively, and an excess lung tissue of 701+/-321 ml was observed. The loss of gas was more pronounced in the lower than in the upper lobes. The lower lobes of 27% of the patients were characterized by "compression atelectasis," defined as a massive loss of aeration with no concomitant excess in lung tissue, and "inflammatory atelectasis," defined as a massive loss of aeration associated with an excess lung tissue, was observed in 73% of the patients. Three groups of patients were differentiated according to the appearance of their CT: 23% had diffuse attenuations evenly distributed in the two lungs, 36% had lobar attenuations predominating in the lower lobes, and 41% had patchy attenuations unevenly distributed in the two lungs. The three groups were similar regarding excess lung tissue in the upper and lower lobes and reduction in FRC in the lower lobes. In contrast, the FRC of the upper lobes was markedly lower in patients with diffuse or patchy attenuations than in healthy volunteers or patients with lobar attenuations. CONCLUSIONS: These results demonstrate that striking differences in lung morphology, corresponding to different distributions of gas within the lungs, are observed in patients whose respiratory condition fulfills the definition criteria of ARDS.

Analysis of Variance↗

Regional distribution of gas and tissue in acute respiratory distress syndrome. II. Physiological correlations and definition of an ARDS Severity Score. CT Scan ARDS Study Group.

OBJECTIVES: (a) To assess whether differences in lung morphology observed in patients with adult respiratory distress syndrome (ARDS) are associated with differences in cardiorespiratory parameters, lung mechanics, and outcome. (b) To propose a new ARDS Severity Score to identify patients with a high mortality risk. DESIGN: Prospective study over a 53-month period. SETTING: Fourteen-bed surgical intensive care unit of a university hospital. PATIENTS AND PARTICIPANTS: Seventy-one consecutive patients with early ARDS. MEASUREMENTS AND RESULTS: Cardiorespiratory parameters were measured using a Swan-Ganz catheter, the pressure-volume (PV) curve was measured using the gross syringe method, and fast spiral computed tomography (CT) was performed. Patients with diffuse attenuations (n = 16) differed from patients with lobar attenuations (n = 26) regarding: (a) mortality rate (75% vs. 42%, p = 0.05), (b) incidence of primary ARDS (82% vs. 50%, p = 0.03), (c) respiratory compliance (47 +/- 12 vs. 64 +/- 16 ml per cmH2O(-1) p = 0.04), and (d) lower inflexion point (8.4 +/- 2.0 vs. 4.6 +/- 2.0 cmH2O, p = 0.001). A third group of patients with patchy attenuations (n = 29) had a mortality rate of 41 %, a respiratory compliance of 56 +/- 18 ml per cmH2O(-1) and a lower inflexion point of 6.3 +/- 2.7 cmH2O. The bedside chest radiograph accurately assessed lung morphology in only 42% of the patients. In contrast to the scores based on the bedside chest radiograph, a new ARDS Severity Score based on CT lung morphology and cardiorespiratory parameters identified a subgroup of patients with a high mortality rate (> or = 60%). CONCLUSIONS: In patients with ARDS, differences in lung morphology are associated with differences in outcome and lung mechanics. A new ARDS Severity Score based on CT lung morphology and cardiorespiratory parameters accurately identified patients with the most severe forms of ARDS and a mortality rate above 60%.

Analysis of Variance↗

Regional distribution of gas and tissue in acute respiratory distress syndrome. III. Consequences for the effects of positive end-expiratory pressure. CT Scan ARDS Study Group. Adult Respiratory Distress Syndrome.

OBJECTIVE: To determine whether differences in lung morphology assessed by computed tomography (CT) affect the response to positive end-expiratory pressure (PEEP). DESIGN: Prospective study over a 53-month period. SETTING: Fourteen-bed surgical intensive care unit of a university hospital. PATIENTS AND PARTICIPANTS: Seventy-one consecutive patients with early adult respiratory distress syndrome (ARDS). MEASUREMENTS AND RESULTS: Fast spiral thoracic CT was performed at zero end-expiratory pressure (ZEEP) and after implementation of PEEP 10 cmH2O. Hemodynamic and respiratory parameters were measured in both conditions. PEEP-induced overdistension and alveolar recruitment were quantified by specifically designed software (Lungview). Overdistension occurred only in the upper lobes and was significantly correlated with the volume of lung, characterized by a CT attenuation ranging between -900 and -800 HU in ZEEP conditions. Cardiorespiratory effects of PEEP were similar in patients with primary and secondary ARDS. PEEP-induced alveolar recruitment of the lower lobes was significantly correlated with their lung volume (gas + tissue) at functional residual capacity. PEEP-induced alveolar recruitment was greater in the lower lobes with "inflammatory atelectasis" than in the lower lobes with "mechanical atelectasis." Lung morphology as assessed by CT markedly influenced the effects of PEEP: in patients with diffuse CT attenuations PEEP induced a marked alveolar recruitment without overdistension, whereas in patients with lobar CT attenuations PEEP induced a mild alveolar recruitment associated with overdistension of previously aerated lung areas. These results can be explained by the uneven distribution of regional compliance characterizing patients with lobar CT attenuations (compliant upper lobes and stiff lower lobes) contrasting with a more even distribution of regional compliances observed in patients with diffuse CT attenuations. CONCLUSIONS: In patients with ARDS, the cardiorespiratory effects of PEEP are affected by lung morphology rather than by the cause of the lung injury (primary versus secondary ARDS). The regional distribution of the loss of aeration and the type of atelectasis -- "mechanical" with a massive loss of lung volume, or "inflammatory" with a preservation of lung volume-- characterizing the lower lobes are the main determinants of the cardiorespiratory effects of PEEP.

Analysis of Variance↗

Role of the heart in the loss of aeration characterizing lower lobes in acute respiratory distress syndrome. CT Scan ARDS Study Group.

In the acute respiratory distress syndrome (ARDS), lower lobes appear essentially non-aerated in contrast to upper lobes whose aeration can be preserved in some patients. The aim of this study was to assess the mechanical compression exerted by the heart on lower lobes in patients with ARDS. Fourteen healthy volunteers and 38 patients with ARDS free of left ventricular failure were studied. Cardiorespiratory parameters were recorded and the cardiac dimensions, the pressure exerted by the heart on subjacent lower lobes, and the gas tissue ratio of lower lobes in the supine position were measured using computer tomography and Lungview, a specifically designed software. In patients with ARDS, the heart was larger and heavier than in healthy volunteers. The enlargement of the heart was mainly related to a left cardiac protrusion and the pressure exerted by the left heart on the lower lobes was higher in patients with ARDS than in healthy volunteers (8 +/- 3 g. cm(-)(2) versus 6 +/- 1 g. cm(-)(2), p < 0.01). As a consequence, the faction of gas represented 62% of the left lower lobes in healthy volunteers and 12% only in patients with ARDS. The present study demonstrates that apart from the already known anteroposterior and cephalocaudal gradients of pressure depending on the lung weight and abdominal pressure, the heart plays an important role in the dramatic loss of aeration characterizing lower lobes of patients with ARDS lying in the supine position.

Adult↗

A computed tomographic scan assessment of endotracheal suctioning-induced bronchoconstriction in ventilated sheep.

This study was directed at assessing changes in bronchial cross-sectional surface areas (BCSA) and in respiratory resistance induced by endotracheal suctioning in nine anesthetized sheep. Cardiorespiratory parameters (Swan-Ganz catheter), respiratory resistance (inspiratory occlusion technique), BCSA, and lung aeration (computed tomography) were studied at baseline, during endotracheal suctioning, and after 20 consecutive hyperinflations. Measurements performed initially at an inspired oxygen fraction (FI(O(2))) of 0.3 were repeated at an FI(O(2)) of 1.0. At an FI(O(2)) of 0.3, endotracheal suctioning resulted in atelectasis, a reduction in BCSA of 29 +/- 23% (mean +/- SD), a decrease in arterial oxygen saturation from 95 +/- 3% to 87 +/- 12% (p = 0.02), an increase in venous admixture from 19 +/- 10% to 31 +/- 19% (p = 0. 006), and an increase in lung tissue resistance (DR(rs)) (p = 0. 0003). At an FI(O(2)) of 1.0, despite an extension of atelectasis and an increase in pulmonary shunt from 19 +/- 5% to 36 +/- 2% (p < 0.0001), arterial O(2) desaturation was prevented and BCSA decreased by only 7 +/- 32%. A recruitment maneuver after endotracheal suctioning entirely reversed the suctioning-induced increase in DR(rs) and atelectasis. In three lidocaine-pretreated sheep, the endotracheal suctioning-induced reduction of BCSA was entirely prevented. These data suggest that the endotracheal suctioning-induced decrease in BCSA is related to atelectasis and bronchoconstriction. Both effects can be reversed by hyperoxygenation maneuver before suctioning in combination with recruitment maneuver after suctioning.

Airway Resistance↗

Measurement of pressure-volume curves in patients on mechanical ventilation. Methods and significance.

In critically ill patients measurements of pressure volume curves has been suggested as a method for assessing the severity of lung injury and for monitoring the evolution of the lung disease; it can also guide the ventilatory adjustments to optimize the mechanical ventilation. The static pressure-volume curves are impaired in acute respiratory distress syndrome (ARDS). The evaluation of the lower and upper inflection point on the pressure-volumes curves at the bedside of patients with acute respiratory failure means to apply a "protective ventilatory strategy". The combined application of positive end expiratory pressure (PEEP) to the level of alveolar recruitment and low tidal volume (< 6 ml/kg) ameliorates the lung function and decrease mortality in ARDS patients. Routine monitoring with continuous technique is easy and develops good therapeutic practice.

Air Pressure↗

A simple automated method for measuring pressure-volume curves during mechanical ventilation.

Measurement of respiratory compliance is advocated for assessing the severity of acute respiratory failure (ARF). Recently, the administration of an automated constant flow of 15 L/min was proposed as a method easier to implement at the bedside than supersyringe or inspiratory occlusions methods. However, pressure-volume (P-V) curves were shifted to the right because of the resistive properties of the respiratory system. The aim of this study was to compare the P-V curves obtained using two constant flows-3 and 9 L/min-during volume-controlled mechanical ventilation with those obtained with the supersyringe and the inspiratory occlusions methods. Fourteen paralyzed patients with ARF were studied. The supersyringe and the inspiratory occlusions methods were performed according to usual recommendations. The new automated method was performed during volume-controlled mechanical ventilation by setting the inspiratory:expiratory ratio at 80%, the respiratory frequency at 5 breaths/min, and the tidal volume at 500 or 1,500 ml. These peculiar ventilatory settings were equivalent to administering a constant flow of 3 or 9 L/min during a 9.6-s inspiration. Esophageal and airway pressures were recorded. P-V curves obtained by the 3-L/min constant-flow method were identical to those obtained by the reference methods, whereas the P-V curve obtained by the 9-L/min constant flow was slightly shifted to the right. The slopes of the P-V curves and the lower inflection points were not different between all methods, indicating that the resistive component induced by administering a constant flow equal to or less than 9 L/min is not of clinical relevance. Because the 3-L/min constant-flow method is not artifacted by the resistive properties of the respiratory system and does not require any other equipment than a ventilator, it is an easy-to-implement, inexpensive, safe, and reliable method for measuring the thoracopulmonary P-V curve at the bedside.

Acute Disease↗

A scanographic assessment of pulmonary morphology in acute lung injury. Significance of the lower inflection point detected on the lung pressure-volume curve.

The goal of this study was to assess lung morphology in patients with acute lung injury according to the presence or the absence of a lower inflection point (LIP) on the lung pressure-volume (P-V) curve and to compare the effects of positive end-expiratory pressure (PEEP). Eight patients with and six without an LIP underwent a spiral thoracic CT scan performed at zero end-expiratory pressure (ZEEP) and at two levels of PEEP: PEEP1 = LIP + 2 cm H2O and PEEP2 = LIP + 7 cm H2O, or PEEP1 = 10 cm H2O and PEEP2 = 15 cm H2O in the absence of an LIP. The volumes of air and tissue within the lungs were measured from the gas-tissue ratio and the volumes of overdistended and normally, poorly, and nonaerated lung areas were determined by the analysis of the frequency histogram distribution. In the ZEEP condition, although total lung volume, volume of gas, and volume of tissue were similar in both groups, the percentage of normally aerated lung was lower (24 +/- 22% versus 55 +/- 12%, p < 0.05) and the percentage of poorly aerated lung was greater (40 +/- 12% versus 23 +/- 8%, p < 0.05) in patients with an LIP than in patients without an LIP. Lung density histograms of patients with an LIP showed a unimodal distribution with a peak at 7 Hounsfield units (HU). Lung density histograms of patients without an LIP had a bimodal distribution, with a first peak at -727 HU and a second peak at 27 HU. Total respiratory system and lung compliances were lower in patients with an LIP whereas all other cardiorespiratory parameters were similar in the two groups. In both groups, PEEP induced an alveolar recruitment that was associated with lung overdistension only in patients without an LIP. The amount of lung overdistension was related to the volume of lung parenchyma, characterized by a CT number less than -800 HU before PEEP implementation (y = 0.52x + 4, R = 0.87, and p < 0.0001). This study shows that the presence or the absence of an LIP on the lung P-V curve is associated with differences in lung morphology. In patients without an LIP on the lung P-V curve, normally aerated lung areas coexist with nonaerated lung areas and increasing levels of PEEP result in lung overdistension rather than in additional alveolar recruitment. In patients with an LIP, air and tissue are more homogeneously distributed within the lungs and increasing levels of PEEP result in additional alveolar recruitment without lung overdistention.

Acute Disease↗

Expiratory washout versus optimization of mechanical ventilation during permissive hypercapnia in patients with severe acute respiratory distress syndrome.

The aim of this study was to compare three ventilatory techniques for reducing PaCO2 in patients with severe acute respiratory distress syndrome treated with permissive hypercapnia: (1) expiratory washout alone at a flow of 15 L/min, (2) optimized mechanical ventilation defined as an increase in the respiratory frequency to the maximal rate possible without development of intrinsic positive end- expiratory pressure (PEEP) combined with a reduction of the instrumental dead space, and (3) the combination of both methods. Tidal volume was set according to the pressure-volume curve in order to obtain an inspiratory plateau airway pressure equal to the upper inflection point minus 2 cm H2O after setting the PEEP at 2 cm H2O above the lower inflection point and was kept constant throughout the study. The three modalities were compared at the same inspiratory plateau airway pressure through an adjustment of the extrinsic PEEP. During conventional mechanical ventilation using a respiratory frequency of 18 breaths/min, respiratory acidosis (PaCO2 = 84 +/- 24 mm Hg and pH = 7.21 +/- 0.12) was observed. Expiratory washout and optimized mechanical ventilation (respiratory frequency of 30 +/- 4 breaths/min) had similar effects on CO2 elimination (DeltaPaCO2 = -28 +/- 11% versus -27 +/- 12%). A further decrease in PaCO2 was observed when both methods were combined (DeltaPaCO2 = -46 +/- 7%). Extrinsic PEEP had to be reduced by 5.3 +/- 2.1 cm H2O during expiratory washout and by 7.3 +/- 1.3 cm H2O during the combination of the two modes, whereas it remained unchanged during optimized mechanical ventilation alone. In conclusion, increasing respiratory rate and reducing instrumental dead space during conventional mechanical ventilation is as efficient as expiratory washout to reduce PaCO2 in patients with severe ARDS and permissive hypercapnia. When used in combination, both techniques have additive effects and result in PaCO2 levels close to normal values.

Acidosis, Respiratory↗