Critical evaluation of the AutoMicrobic system gram-negative identification card for identification of glucose-nonfermenting gram-negative rods.

During a 6-month study we critically evaluated the accuracy of the AutoMicrobic system Gram-Negative Identification Card (Vitek Systems, Inc., Hazelwood, Mo.) in identifying glucose-nonfermenting gram-negative bacilli by testing 419 selected isolates in parallel with a conventional reference method. Of 356 isolates included in the AutoMicrobic system profile, a total of 307 (86.2%) were correctly identified, 36 (10.1%) were not identified, and 13 (3.7%) were misidentified. Fifty-eight of 63 (92%) isolates not included in the profile were correctly reported as "unidentified organisms." Overall, if the first-choice identification was always accepted, only 18 (4.3%) isolates would have been incorrectly reported. When first-choice identifications appended with the special message "questionable biopattern" were rejected, and organisms were screened for characteristic odor and antimicrobial susceptibility before final acceptance of the AutoMicrobic system report, the number of misidentifications was reduced to 5 (1.2%). The average time to identification with the AutoMicrobic system Gram-Negative Identification Card was 15 h. This compares favorably with the 65 h required by the reference method.

Acinetobacter↗

Comparison of cross-staining reactions by Pseudomonas spp. and fluorescein-labeled polyclonal and monoclonal antibodies directed against Legionella pneumophila.

Commercially prepared polyclonal antisera to Legionella pneumophila are known to cross-react with organisms of the genus Pseudomonas. To determine whether a commercially available monoclonal antibody reagent specific for L. pneumophila would also cross-react with pseudomonads, a two-laboratory study was undertaken to test both monoclonal and polyclonal reagents against 33 isolates of Pseudomonas spp., including 25 Pseudomonas aeruginosa, 4 P. putida, 2 P. maltophilia, 1 P. fluorescens, and 1 P. alcaligenes. Four antisera were tested; polyclonal anti-legionella antisera pools A and B (Centers for Disease Control [CDC], Atlanta, (Ga.), polyclonal 1-6 antisera (BioDx, Inc., Denville, N.J.), and a monoclonal antibody reagent produced by Genetic Systems Corp., Seattle, Wash. All reagents were labeled with fluorescein. Cross-staining reactions were found with the BioDx L. pneumophila antisera and 10 isolates of Pseudomonas. Four of these isolates demonstrated cross-staining with CDC pool A. When tested with individual serotype-specific reagents (CDC), three of four cross-reacted with L. pneumophila serotype 1 antisera; the fourth cross-reacted with serotype 3. No cross-staining reactions were noted with the monoclonal reagent and any of the pseudomonads tested, demonstrating that the Genetic Systems Corp. monoclonal reagent is the most specific of the four reagents tested.

Antibodies, Bacterial↗

Increased detection of staphylococcal bacteremia using an anti-microbial removal device.

During the period of August 16, 1981, through December 16, 1982, 15-mL blood culture specimens collected at the Seattle Veterans Administration Medical Center (SVAMC) were divided into two aliquots. The first 10-mL aliquot was inoculated directly into aerobic and anaerobic BACTEC (Johnston Laboratories, Towson, MD) vials (DIR); the remaining 5 mL was processed in an resin-containing Antimicrobial Removal Device (Marion Scientific, Kansas City, MO) before transfer to a second, identical set of aerobic and anaerobic vials (ARD). The final volume of inoculated blood from the ARD specimen was half that of the DIR specimen. Both sets of vials were processed using the BACTEC radiometric detection system. One hundred fifty specimen pairs grew 161 significant pathogens; 43 isolates were recovered only from the ARD sample, 39 only from the DIR samples, and 79 from both. Of the 35 isolates recovered from patients receiving anti-microbial agents active against the isolated pathogens, 21 were recovered only from the ARD specimen and 5 only from the DIR specimen (P less than 0.005). Of the 15 S. aureus strains isolated from patients on therapy, 12 were recovered only from the ARD specimen, 2 only from the DIR sample, and 1 from both samples (P less than 0.01). Ten of the 32 isolates of S. aureus recovered from antibiotic-free patients were found only in the ARD specimen and three only in the DIR specimen (P = 0.05). The ARD specimens recovered significantly more S. aureus from all patients regardless of antibiotic status.

Bacteriological Techniques↗

Instability of antibiotic resistance in a strain of Staphylococcus epidermidis isolated from an outbreak of prosthetic valve endocarditis.

Plasmid profiles, phage typing, antibiograms, and biotyping were used to characterize Staphylococcus epidermidis isolated from multiple cultures of blood of four patients with prosthetic valve endocarditis. Epidemiological evidence implicated a common source for these infections. Of 20 clinically significant isolates, 14 exhibited variations from the prototype pattern of multiple resistance to five antibiotics. All isolates tested appeared to be the same strain by phage typing. Of 18 isolates available for plasmid analysis, 10 contained six plasmids of identical size, whereas eight differed from the prototype profile in the loss of one to three plasmids. Loss of resistance to gentamicin, chloramphenicol, erythromycin, and clindamycin but not to methicillin was associated with the loss of specific plasmids. Because antibiotic resistance in this strain of S. epidermidis was unstable, the use of antibiograms alone was not a reliable means of evaluating the relatedness of these multiple isolates.

Anti-Bacterial Agents↗

Survey of plasmids and resistance factors in Campylobacter jejuni and Campylobacter coli.

A total of 688 isolates of Campylobacter jejuni and Campylobacter coli were screened for the presence of plasmid DNA by agarose gel electrophoresis and were tested for susceptibility to ampicillin, chloramphenicol, erythromycin, streptomycin, and tetracycline. Of the isolates examined, 32% were noted to harbor plasmid DNA, ranging in size from 2.0 to 162 kilobases. Only tetracycline resistance was noted to correlate with the presence of plasmids. Plasmids capable of transferring tetracycline resistance via conjugation ranged in size from 42 to 100 kilobases. The Bg/II and Bc/I restriction endonuclease profiles of 31 plasmids examined showed marked diversity in their banding patterns. Although a high degree of DNA-DNA homology was noted among the Campylobacter spp. plasmids, no homology was noted between these plasmids and tetracycline R factors commonly found in the family Enterobacteriaceae.

Anti-Bacterial Agents↗

Development of two DNA probes for differentiating the structural genes of subclasses I and II of the aminoglycoside-modifying enzyme 3'-aminoglycoside phosphotransferase.

Two DNA probes were developed to screen for the genes encoding 3'-aminoglycoside phosphotransferase activity in gram-negative bacilli. The 3'-I phosphotransferase [APH(3')I] probe was subcloned from Tn903; the APH(3')II probe was subcloned from Tn5. Each probe proved to be specific for genes corresponding to its own APH(3') subclass and did not hybridize with DNA from other classes when tested at high stringency by either Southern hybridization or dot-blot hybridization methods. The APH(3')I probe hybridized to DNA obtained from organisms demonstrating APH(3')I activity as measured by the phosphocellulose paper binding assay (PPBA) as well as to DNA from organisms reported to have both APH(3')I and APH(3')II activity by PPBA. This probe did not hybridize to DNA from organisms showing only APH(3')II activity by PPBA. The APH(3')II probe demonstrated homology with DNA from organisms showing APH(3')II activity by PPBA but not with DNA from organisms showing APH(3')I activity or both APH(3')I and APH(3')II activity by PPBA. We conclude that organisms previously believed to contain both APH(3')I and APH(3')II genes based on PPBA contain in fact only the APH(3')I gene.

Autoradiography↗

Comparison of three DNA hybridization methods for detection of the aminoglycoside 2"-O-adenylyltransferase gene in clinical bacterial isolates.

Two rapid DNA hybridization methods in which whole-cell lysates fixed to nitrocellulose were used were compared with Southern hybridization of purified plasmid or chromosomal DNA for the ability to identify the 2"-O-adenylyltransferase [ANT(2")] gene in 42 enzymatically defined isolates of gram-negative bacilli. A DNA restriction fragment isolated from an ANT(2") gene cloned into pBR322 and radiolabeled with 32P was used as the probe in all three procedures. Under conditions of high stringency, agreement was obtained between the Southern hybridization method and detection of the ANT(2") enzyme by the phosphocellulose paper binding assay or resistance phenotype in 39 of the 42 strains tested. By using these characterized strains, colony hybridization was shown to be unsatisfactory as a rapid technique for detecting the ANT(2") gene, due to the high number of false-positive and -negative signals obtained. Compared with Southern hybridization, however, spot hybridization (SPH) proved highly reliable for detecting the ANT(2") gene in both members of Enterobacteriaceae and Pseudomonas aeruginosa harboring R factors ranging in size from 23 to 150 kilobases. The relatively low copy number of the 150-kilobase plasmids decreased the sensitivity of SPH, necessitating a minimum cell density of 5 X 10(6) cells per spot. SPH proved to be a very useful method for rapidly screening large numbers of clinical isolates for this resistance determinant.

Collodion↗

Use of auxotyping for epidemiological studies of Campylobacter jejuni and Campylobacter coli infections.

A chemically defined medium developed for Neisseria gonorrhoeae was modified to support the growth of Campylobacter jejuni and Campylobacter coli. A total of 76 isolates of C. jejuni and 14 isolates of C. coli were tested on this medium, which was designated Campylobacter defined medium (CDM), over a 3-month period. Although none of the C. coli isolates appeared to require amino acids, 51% of the C. jejuni tested required one and 7% required multiple amino acids for growth. An analysis of isolates obtained from three household outbreaks of campylobacteriosis demonstrated that auxotyping identified the epidemic strain within each outbreak. Among 70 isolates of C. jejuni examined, no correlation could be drawn between a specific serotype and auxotype or between auxotype and plasmid profile.

Amino Acids↗

Confirmation of Legionella pneumophila cultures with a fluorescein-labeled monoclonal antibody.

We compared a fluorescein-labeled monoclonal antibody directed against an outer membrane protein of Legionella pneumophila (Genetic Systems Corp. [GSC], Seattle, Wash.) with a similarly labeled polyclonal reagent (L. pneumophila serogroups 1 to 6, poly; BioDx, Inc., Denville, N.J.) for the confirmation of L. pneumophila isolates grown in culture. Duplicate suspensions of 52 organisms, including 21 L. pneumophila and 8 non-L. pneumophila species of legionella, were placed on individual glass slides, fixed, and stained with both reagents, and the results were compared. Both antisera correctly identified all L. pneumophila serogroups 1 to 6, but only the GSC reagent produced definitive staining of the L. pneumophila isolates of serogroups 7, 8, and 9. Additionally, the GSC reagent produced more uniform staining patterns around the legionella bacilli and displayed little background fluorescence when compared with the BioDx reagent.

Antibodies, Bacterial↗

Comparison of the automicrobic system, acridine orange-stained smears, and gram-stained smears in detecting bacteriuria.

We compared the accuracy of the Gram-stained smear, the acridine orange-stained smear, and the AutoMicrobic system (AMS; Vitek Systems, Inc., Hazelwood, Mo.) in screening for bacteriuria, as detected by conventional cultures. For 1,024 clinical specimens, results with the acridine orange-stained smear and the Gram-stained smear were very similar. When read for the presence of one or more microorganisms or leukocytes per 20 oil immersion fields, both smears were highly sensitive (92.1 and 93.3%, respectively) and moderately specific (70.0 and 61.7%, respectively). Sensitivity was greater for specimens yielding greater than or equal to 10(5) CFU/ml (96.1 and 98.9%, respectively) than for those with 10(3) to 10(4) CFU/ml (81.4 and 78.0%, respectively). Preliminary classification based upon the tinctorial and morphological characteristics of the Gram-stained smear was compatible with culture results in nearly all cases. The accuracy of the Gram-stained smears was not influenced by special cleaning of the microscopic slides, or the level of expertise of the microscopist. For 715 specimens, the sensitivity of the AMS in detecting bacteriuria (91.5%) was very similar to that of the stained smears (92.1 and 95.7%, respectively), but the specificity was significantly higher (83.2% versus 42.6 and 70.0%). Detection of microorganisms by the AMS took an average of 6.3 +/- 3.0 h. These data suggest that the Gram-stained smear is easily interpreted, very sensitive, acceptably specific, and still the optimal rapid method for screening for bacteriuria in most clinical microbiology laboratories.

Acridine Orange↗

Specimen volume versus yield in the BACTEC blood culture system.

During a 24-month period, 5,625 blood culture specimens were collected at the Seattle Veterans Administration Medical Center in 20-ml volumes and divided into separate 10-ml aliquots. The two aliquots were processed as duplicate sets (set 1, set 2) by the BACTEC system (Johnston Laboratories, Inc., Towson, Md.). Specimens (5 ml) from each set were inoculated into aerobic (6B) and anaerobic (7C/7D) vials. A total of 434 significantly positive blood cultures were found. In 342 of these positive cultures, yielding 379 isolates (112 members of the family Enterobacteriaceae, 104 staphylococci, 87 streptococci, 27 anaerobes, 20 yeasts, 14 pseudomonads, and 15 miscellaneous organisms), there was adequate specimen volume to fill all four vials. The utilization of set 1 would have resulted only in the failure to detect 65 of 379 (17.2%) significant isolates, 52 of 342 (15.2%) positive cultures, and 20 of 198 (10.1%) bacteremic episodes. There were no significant differences in the recovery of individual species in sets 1 and 2. Although the range of isolates recovered by the aerobic and anaerobic vials of each set differed, the percent yield of total isolates was similar, indicating total isolate yield was predominantly a function of specimen volume. The addition of set 2 most dramatically increased the recovery of Escherichia coli (30%), yeasts (33%), and anaerobes (42%).

Bacteriological Techniques↗

Is the clean-catch midstream void procedure necessary for obtaining urine culture specimens from men?

To determine whether the results of voided urine cultures in men are affected by meatal cleansing, midstream sampling, or circumcision status, 308 paired (initial and midstream) specimens were collected from 254 urology clinic patients. Half of the patients cleansed their urethral meatus with povidone-iodine prior to voiding. The circumcision status of all patients was noted. The rates of true bacteriuria (growth of 10(4) or greater colony-forming units/ml urine with a single predominant species) and contamination (growth of 10(3) or greater colony-forming units/ml urine with two or more colonial types) were compared in the various collection technique subgroups. Neither the bacteriuria nor contamination rates were significantly different (p greater than 0.05) in circumcised and uncircumcised patients, or in those who cleansed their meatus and those who did not. Contamination, but not bacteriuria, rates were higher in initial as compared with midstream specimens. These data suggest that the clean-catch midstream void procedure is unnecessary for obtaining routine voided urine culture specimens from men.

Bacteriuria↗

Development of a DNA probe for the structural gene of the 2"-O-adenyltransferase aminoglycoside-modifying enzyme.

Analysis of aminoglycoside-resistant Enterobacteriaceae isolated from patients at the Seattle Veterans Administration Medical Center indicated that a single 68-kilobase R factor was responsible for the epidemic spread of low-level resistance to gentamicin, kanamycin, and tobramycin. An examination, by means of the phosphocellulose paper binding assay, of resistant strains carrying this R factor resulted in the identification of a 2"-O-adenyltransferase [ANT(2")]-modifying enzyme. This enzyme was later detected in strains containing 150-kilobase plasmids. For more convenient monitoring of the dissemination of the ANT(2") gene among clinical isolates at the medical center, a DNA probe was developed by cloning of the ANT(2") structural gene from the 68-kilobase factor into pBR322. A 310-base pair Ava I restriction fragment isolated from the interior of the cloned ANT(2") gene was radiolabeled and used in Southern hybridization gels as a probe for plasmids isolated from aminoglycoside-resistant organisms. The probe proved to be highly specific and was more sensitive than enzymologic techniques for detection of the ANT(2") gene in clinical isolates with complex aminoglycoside resistance phenotypes.

Aminoglycosides↗

Rapid antimicrobial susceptibility testing of isolates from blood cultures by direct inoculation and early reading of disk diffusion tests.

Disk diffusion tests, inoculated directly from positive blood cultures, were evaluated for accuracy of reading zone diameters after 4- and 6-h and overnight incubation. In comparisons with results from standard disk diffusion tests, the 4-h results were in agreement for 83% of tests with gram-positive organisms and 64% of tests with gram-negative organisms. When minor discrepancies were ignored, the 4-h readings were in agreement for 98% of the tests with gram-positive organisms and 95% of the tests with gram-negative organisms. After 6 h of incubation, 91% of the tests with gram-positive organisms and 86% of the tests with gram-negative organisms agreed with standard results. The agreement was 99% for tests with both gram-positive and gram-negative organisms when minor discrepancies were excluded. Very major discrepancies occurred in two tests (0.1%) with gram-positive organisms and were not observed in tests with gram-negative organisms. The frequencies of major discrepancies were 3.5% after 4 h, 0.6% after 6 h, and 0.7% after overnight incubation. Ampicillin and cephalothin tests with Escherichia coli and Klebsiella spp. accounted for 81% of the major discrepancies in tests with gram-negative organisms. Oxacillin tests accounted for more than half of the major discrepancies in tests with staphylococci. The results of this study, which did not include the newer antibiotics, indicate that direct susceptibility tests from blood cultures read after 6 h of incubation are more reliable than 4-h results and produce less than 1% major errors in comparisons with standard susceptibility tests.

Anti-Bacterial Agents↗

Hemophilus influenzae as a cause of urinary tract infections in men.

Hemophilus influenzae has rarely been reported to cause urinary tract infections, but media supportive of its growth are not routinely used for urine cultures. At two Veterans Administration medical centers, H influenzae was isolated from the urine of eight men in the past four years. All had anatomic or functional genitourinary abnormalities, and half had had chronic pyelonephritis or recurrent urinary tract infections. Three patients had acute cystitis, two patients had pyelonephritis, two patients had prostatitis, and one patient had asymptomatic bacteriuria with pyuria. Cases were discovered by primary isolation on chocolate agar or sheep's blood agar, by "satelliting" around staphylococci, or by positive urine Gram's stains. Urine Gram's stains disclosed organisms in all six nonprostatitis cases. Organisms were all nonserotypable, were of biotypes 2, 3, or 4, and were beta-lactamase negative. Hemophilus influenzae may be a more common uropathogen in adults than previously recognized.

Adult↗

Fever and pulmonary infiltrates in a patient with a renal transplant.

This discussion was selected from the weekly Grand Rounds in the Department of Medicine, University of Washington, Seattle. Taken from a transcription, it has been edited by Drs Paul G. Ramsey, Assistant Professor of Medicine, and Philip J. Fialkow, Professor and Chairman of the Department of Medicine.

Adult↗

Evaluation of the FIAX semiautomatic fluorescent immunoassay system for the detection of IgG antibodies to Toxoplasma gondii.

A commercially available solid phase fluoroimmunoassay system (FIAX, International Diagnostic Technology, Santa Clara, CA) was evaluated in parallel with a standard indirect fluorescent-antibody test (IFAT) for the detection of IgG antibodies to Toxoplasma gondii. Titers obtained by the FIAX method on the 101 patient samples correlated well with the standard procedure. Sensitivity of the FIAX system was 96% and specificity was 93%. A method for measuring serum titer reproducibility applicable to both conventional doubling dilution and to automated procedures was employed, allowing a meaningful comparison of precision in the two systems. It was found that titer reproducibility in the FIAX system was better than that of the IFAT and exceeded that expected with most conventional double-dilution serological procedures. The FIAX system will most benefit those laboratories with relatively large numbers of samples which can be batch tested.

Evaluation Studies as Topic↗