Search PubMed⌕ Search

Biomedical subjects

J J Froelich

Publications and source records attributed to J J Froelich.

22 records · Page 2Linked to original sources

Feasibility of C-arm-supported CT fluoroscopy in percutaneous abscess drainage procedures.

PURPOSE: Evaluation of C-arm-supported CT fluoroscopy to facilitate percutaneous abscess drainage procedures. METHODS: Prospectively, 40 percutaneous drainage procedures were performed either with C-arm-supported CT fluoroscopy or with CT fluoroscopy alone. Hybrid imaging was performed on the CT couch after complementing a CT fluoroscopy scanner with a C-arm fluoroscopy unit. Procedure times, drainage revisions during follow-up, and postinterventional drainage periods were analyzed. RESULTS: When compared with exclusive CT fluoroscopic guidance, a median procedure time of 9 +/- 3.7 min versus 14.8 +/- 7.3 min was required for C-arm-supported CT fluoroscopy (p < 0.005, t-test). During follow-up, eight drainage catheters had to be revised within the exclusive CT fluoroscopy group, while only two revisions were necessary within the C-arm-supported CT fluoroscopy group. With C-arm-supported CT fluoroscopy, postinterventional drainage periods were reduced (median 13 vs 19 days; p < 0.001, t-test). CONCLUSION: Compared with exclusive cross-sectional image guidance, C-arm-supported CT fluoroscopy seems to improve placement of abscess drainage catheters to possibly reduce procedure times, drainage catheter revisions, and postinterventional drainage periods.

Abscess↗

Local intraarterial thrombolysis: in vitro comparison of various infusion catheters.

PURPOSE: Catheters are compared in vitro to evaluate the efficacy of thrombolysis during urokinase infusion within the thrombus. METHODS: Six catheters were introduced individually into human thrombus within a stenotic flow model. Urokinase was infused continuously into the thrombus. To quantify the efficacy of thrombolysis, pressure gradients were recorded proximal and distal to the thrombus and during the course of infusion. Uniformity of lysis was assessed radiographically. RESULTS: The fastest and most homogeneous thrombolysis was achieved with the EDM and the straight-flush catheter, shown by decreasing transthrombotic pressure gradients. All other catheter designs showed less homogeneous and delayed thrombolysis (p </= 0.001, Friedmann-Test, Schaich-Hamerle). There was no significant difference in the efficacy of thrombus dissolution between the EDM and the straight-flush catheter (Wilcoxon, matched pairs, p > 0.7). CONCLUSION: The EDM catheter and the straight flush catheter achieved the most homogeneous and fastest thrombolysis, apparently due to the best urokinase distribution within the thrombus.

Catheterization↗

The precise determination of vascular lumen and stent diameters: correlation among calibrated angiography, intravascular ultrasound, and pressure-fixed specimens.

PURPOSE: Luminal diameters measured in vivo by calibrated-catheter angiography and by intravascular ultrasound were correlated with those obtained from pressure-fixed histologic cross-sections to determine the accuracy of both methods. METHODS: Angiographic and endosonographic diameter measurements were performed in the center of stents placed in the iliac arteries of 10 miniature pigs and were compared with luminal and stent diameters in postmortem, pressure-fixed, histologic cross-sections from identical locations. RESULTS: Compared with histologic diameters, magnification-corrected angiographic measurements still magnified vascular luminal diameters by 0.7 +/- 0.71 mm (r = 0.41, Pearson; p < 0.003, Wilcoxon, matched pairs), whereas intravascular ultrasound measurements proved to be almost identical to the histologic lumina (r = 0.95, Pearson; p > 0. 5, Wilcoxon, matched pairs). Similarly, stent diameters correlated well between endosonographic and histologic measurements (r = 0.91; p = 0.002), and less well between angiographic and histologic diameters (r = 0.62; p = 0.002). CONCLUSION: Since calibrated angiography still overestimates vascular lumina, endosonography is the preferred technique for accurate in vivo measurements.

Angiography↗