Search PubMed⌕ Search

Biomedical subjects

J J Crawford

Publications and source records attributed to J J Crawford.

At least 19 recordsLinked to original sources

Effect of whitening agents containing carbamide peroxide on cariogenic bacteria.

PURPOSE: The purpose of this study was to investigate the in vitro antibacterial effects of three different carbamide peroxide products (Nitewhite, Opalescence, and Proxigel) on cariogenic microorganisms (mutans streptococci [MS] and lactobacilli), and to evaluate the effects of a 10% carbamide peroxide solution (Proxigel) on salivary levels of MS and lactobacilli clinically. MATERIALS AND METHODS: Growth inhibition studies were performed to determine the concentration and exposure time of carbamide peroxide to give total inhibition of recoverable growth of MS and lactobacilli. Paraffin-stimulated saliva samples were collected from subjects before and after 6 weeks of treatment with 10% carbamide peroxide in bleaching trays, and levels of MS and lactobacilli were determined. RESULTS: The growth inhibition studies showed no visible growth of MS or lactobacilli at 24-, 48-, or 72-hour incubation, after a 2-hour exposure to 1% carbamide peroxide. Identical results were obtained with all three carbamide peroxide products. In the clinical study, the mean salivary MS levels, expressed as logarithm colony-forming units per milliliter (CFU/mL), were 5.38 for the pretreatment samples and 5.23 for the post-treatment samples. The differences were not statistically significant (p > .05). However, there was a reduction in logarithm lactobacilli counts from a mean of 4.12 pretreatment to a mean of 2.74 post-treatment. This was statistically significant (p < .05).

Adult↗

Biodegradation of atrazine under denitrifying conditions.

Anaerobic biodegradation of atrazine by the bacterial isolate M91-3 was characterized with respect to mineralization, metabolite formation, and denitrification. The ability of the isolate to enhance atrazine biodegradation in anaerobic sediment slurries was also investigated. The organism utilized atrazine as its sole source of carbon and nitrogen under anoxic conditions in fixed-film (glass beads) batch column systems. Results of HPLC and TLC radiochromatography suggest that anaerobic biotransformation of atrazine by microbial isolate M91-3 involved hydroxyatrazine formation. Ring cleavage was demonstrated by 14CO2 evolution. Denitrification was confirmed by detection of 15N2 in headspace samples of K15NO3-amended anaerobic liquid cultures. In aquatic sediments, mineralization of uniformly ring-labeled [14C]atrazine occurred in both M91-3-inoculated and uninoculated sediment. Inoculation of sediments with M91-3 did not significantly enhance anaerobic mineralization of atrazine as compared to uninoculated sediment, which suggests the presence of indigenous organisms capable of anaerobic atrazine biodegradation. Results of this study suggest that the use of M91-3 in a fixed-film bioreactor may have applications in the anaerobic removal of atrazine and nitrate from aqueous media.

Atrazine↗

Using a biological indicator to detect potential sources of cross-contamination in the dental operatory.

The authors conducted a study using surveillance monitoring methodology to identify operatory contamination and to evaluate the effectiveness of infection control procedures. Viridans streptococci were evaluated as biological indicators of oral contamination. Viridans streptococci, abundant in human saliva, were detected on operatory surfaces after dental treatments were finished and surfaces were disinfected. The findings validate current concepts of infection control as demonstrated in barrier methods.

Adult↗

Backflow in low-volume suction lines: the impact of pressure changes.

A previous study indicated that fluid can flow backward in low-volume suction lines when patients close their lips around the saliva ejector tip. The authors investigated this phenomenon further. They documented physical and mechanical parameters of saliva ejector backflow in low-volume suction lines and concluded that backflow is possible but can be avoided with simple precautions.

Cross Infection↗

Efficacy of sterilization of endodontic files after autoclaving in a synthetic sponge.

A common way of sterilizing endodontic files for clinical use is to insert them into synthetic sponges. The files are sterilized in the sponge, and the sponge is then used on the patient tray for ease of file retrieval. The ability to sterilize the files in a sponge has been questioned. The purpose of the present investigation was to evaluate the sterility of files and spore strips following autoclaving in a sponge. Commercial spore strips and contaminated endodontic files were inserted into sponges, sealed in sterilization pouches and autoclaved. The spore strips and the files were removed from the sponge and cultured for growth of microorganisms. Results show that no microbes were cultured from spore strips or contaminated files after autoclaving them in the sponges sealed in autoclave pouches. These results indicate that the insertion of files into the sponges used in this study does not obstruct the autoclaving process.

Colony Count, Microbial↗

Evaluating spatter and aerosol contamination during dental procedures.

A pilot study evaluated the distribution of spatter and aerosols generated by high-speed instrumentation. In the first phase, fluorescent dye was added to the handpiece water supply. In the second, blood agar culture plates were placed in the operatory. Results show that contamination from spatter and aerosol dissemination remains a significant hazard for dental personnel.

Aerosols↗

Current status of Occupational Safety and Health Administration infection control regulations.

In the wake of widespread hepatitis B, human immunodeficiency virus, and other bloodborne infections, organizations of health care employees have asked the Occupational Safety and Health Administration (OSHA) to address the reduction of infection risks encountered in the delivery of private and institutional health care. The task is much the same as reducing job related risks in industry. This article explains and reviews interim OSHA infection control regulations that apply to dentistry now, anticipating a final rule soon to be released by OSHA. Helpful forms, details, and information sources are provided.

Communicable Disease Control↗

Evaluation of a dental unit designed to prevent retraction of oral fluids.

Most older units that drive high-speed dental handpieces include a retraction device designed to prevent dripping of fluids from the water-spray line after the unit has been turned off. Oral fluids and debris may be drawn, along with water, into the water line. Bacteria and debris, unless deliberately flushed out of the water line, may be transmitted to the next patient. Most new units now have mechanisms to prevent retraction. A new dental control unit, designed to eliminate mechanical aspiration of oral fluids, was tested. A kit to test the level of retraction in the water-spray line was also examined. The new unit was found to be effective in protecting the unit water from contamination by oral microorganisms, thereby protecting patients from cross-contamination. However, the control of retraction did not prevent the colonization of the water line by aquatic bacteria. Both internal and external sources of microorganisms must be controlled.

Cross Infection↗

A psychometric study of positive and negative nominations and the pupil evaluation inventory.

Two peer evaluation measures, the Pupil Evaluation Inventory (PEI) and positive and negative nominations were compared in a sample of 260 children in grades 1 to 5. Stabilities of the measures were assessed over a 4-month period. In the total sample, PEI factors and negative nominations were more stable than positive nominations, and PEI Aggression and Withdrawal scores were more stable than negative nominations. PEI Aggression and Withdrawal scores were more stable in grades 3 and 5 than in grade 1, and the Likability factor was more stable in grades 2 to 5 than in grade 1. Negative nominations were most strongly correlated with the PEI Aggression factor, and positive nominations were more strongly correlated with Likability than with Aggression. Implications for the use of these nomination measures are discussed.

Aggression↗

Bacteremia following intraoral suture removal.

Following dental extractions, prophylactic antibiotic protection of patients at high risk of cardiovalvular infection is usually discontinued before suture removal. To determine whether bacteremia is created upon removal of intraoral sutures, twenty healthy patients who required extractions of at least five erupted teeth and placement of several sutures were selected without regard to sex, age, or race. Blood samples were drawn preoperatively, immediately after the extractions, before suture removal, and immediately following removal of the intraoral silk sutures. The samples were cultured in prereduced and aerobic media suitable for quantitative colony counts. Fourteen of 16 patients yielded positive blood cultures following tooth extractions. One of 20 patients yielded a positive blood culture following suture removal. Even though the incidence of bacteremia following intraoral suture removal is relatively low (5%), this study suggests that intraoral suture removal is not a benign procedure for those persons who are considered high-risk cardiac patients.

Bacteria↗

Analytical and physiological variability of salivary microbial counts.

Quantitation of mutans streptococci (MS) and Lactobacillus has been proposed as a method for the identification of patients at high risk for dental caries. The purpose of the present study was to investigate the analytical and physiological variability of this procedure. Variability due to specimen collection and processing was investigated by repeated sampling studies. Sample stability was investigated over storage periods of up to 72 hr at 5 degrees C, room temperature, and 37 degrees C. Physiological variability was investigated by performance of serial analyses on ten individuals, who collected six samples at intervals on a single day, and rising and noon samples on ten subsequent days. Sample collection, rather than sample processing, was found to be the major factor determining the imprecision of salivary microbial analysis in the majority of cases. However, individual subjects varied considerably in the consistency with which they provided saliva samples. Imprecision due to sample processing was relatively small, with coefficients of variations of 2.3% for MS counts and 2.1% for Lactobacillus counts. Samples were generally stable over a wide temperature range for at least 72 hours, although there was some loss of viability of lactobacilli on prolonged storage at room temperature or 37 degrees C in one experiment. Rising samples yielded higher counts than samples collected after breakfast and toothbrushing. Day-to-day variability was considerable, with 95% confidence limits exceeding 1 log in 28% of data sets for MS count and 39% of data sets for Lactobacillus.

Circadian Rhythm↗

Control of cross-infection risks in the dental operatory: prevention of water retraction by bur cooling spray systems.

A new dental unit control system was found to overcome the possibility of mechanically retracting bacteria from the mouth into the water line used to provide a spray of water to cool high-speed burs during treatments. This was demonstrated by results obtained after clinical use and after use in simulated, worst case test conditions using a red tempera indicator solution and indicator bacteria.

Bacillus subtilis↗

State-of-the-art: practical infection control in dentistry.

Practical infection control in the operatory is a multi-step process. Protocol should be updated to include good: identification of high-risk patient populations, barrier technique, aseptic technique, surface disinfection, instrument sterilization, and equipment disinfection and sterilization.

Antisepsis↗