Search PubMed⌕ Search

Biomedical subjects

J J Callaghan

Publications and source records attributed to J J Callaghan.

At least 55 records · Page 3Linked to original sources

A finite element analysis of factors influencing total hip dislocation.

A previously validated three-dimensional finite element model was used to study how several total hip component design and surgical placement variables contribute to resisting the propensity for posterior dislocation in the case of leg crossing in an erectly seated position. The computational formulation incorporated treatments of polyethylene material nonlinearity and large displacement sliding contact. The primary outcome measures were the peak intrinsic moment developed to resist dislocation, and the ranges of motion before neck on lip impingement and before frank dislocation. Modifications of the acetabular linear design (chamfer bevel angle, lip breadth, head center inset) involved trading off improved peak resisting moment for compromised range of motion and vice versa. Increases of head size led to substantial improvements in peak resisting moment, but if the head to neck diameter ratio was held constant, had almost no influence on the component range of motion. For the leg crossing event studied, increased component anteversion, and even more so increased tilt (less net abduction), achieved improvements in range of motion and in peak resisting moment, but these changes imply diminished resistance to anterior dislocation from extension and adduction motion inputs.

Arthroplasty, Replacement, Hip↗

Salvage of total hip instability with a constrained acetabular component.

Between April 1988 and February 1993, 101 constraining acetabular components were implanted into 98 patients. One patient was lost to followup at 8 months. Otherwise, all patients were observed until death or for at least 2 years minimum followup. The average clinical followup for the living patients was 61 months (range, 24-97 months). Indications for the use of the constrained acetabular components were recurrent dislocation (an average of six dislocations, range 2-20) in 56 cases, intraoperative instability in 38 cases, and neurologic impairment in seven cases. For the entire group there were four cases of recurrent dislocation or failure of the component (4%). For the cases where this component was used for recurrent dislocation, 96% (54 of 56 cases) had no additional dislocations. Radiographically, at this short term followup, there was no evidence of an increased incidence of femoral or acetabular component loosening. The authors recommend judicious use of this component as a salvage measure for desperate cases of hip instability during or after total hip arthroplasty.

Acetabulum↗

Salvage of a recurrently dislocating total hip prosthesis with use of a constrained acetabular component. A retrospective analysis of fifty-six cases.

Fifty-six constrained acetabular components were placed, between April 1988 and February 1993, in fifty-five patients who had had recurrent dislocations (average, six dislocations; range, two to twenty dislocations) of the femoral component after a previous total hip arthroplasty. All patients had additional factors contributing to the instability of the implant, including absence or disruption of the abductor mechanism, poor health, mental retardation, confusion, and Alzheimer disease. One patient was lost to follow-up. The remaining patients were followed clinically for a minimum of three years (average, sixty-four months; range, thirty-seven to ninety-seven months) or until the time of death. During the follow-up interval, only two (4 per cent) of the fifty-five patients had a subsequent dislocation. The use of this type of component should be considered for patients who have recurrent dislocation if other treatment modalities are unlikely to be effective.

Acetabulum↗

Charnley total hip arthroplasty in patients less than fifty years old. A twenty to twenty-five-year follow-up note.

We evaluated the results twenty to twenty-five years after ninety-three consecutive, nonselected Charnley total hip arthroplasties performed with cement by the senior one of us in sixty-nine patients who were less than fifty years old at the time of the procedure. Seventy of the seventy-two hips in the living patients were followed radiographically for at least twenty years. Twenty-seven hips (29 per cent) had a revision or a resection of the prosthesis during the follow-up period. The revision or the resection was performed because of aseptic loosening in twenty-one hips (23 per cent), infection in four (4 per cent), dislocation in one (1 per cent), and fracture of the femur in one. Eighteen acetabular components (19 per cent) and five femoral components (5 per cent) were revised because of aseptic loosening, and an additional fourteen acetabular components (15 per cent) and seven femoral components (8 per cent) demonstrated definite or probable radiographic loosening. The present study demonstrates the long-term durability of total hip arthroplasty performed with cement in an active population of patients. The fixation of the femoral component was found to perform better than that of the acetabular component at twenty to twenty-five years after the procedure.

Adolescent↗

Total hip arthroplasty with cement in patients who have rheumatoid arthritis. A minimum ten-year follow-up study.

One hundred and six consecutive total hip arthroplasties with cement were performed by one surgeon, at least ten years before the time of the present clinical and radiographic review, in seventy-five patients who had adult-onset rheumatoid arthritis. Two patients (three hips) were lost to follow-up. Seven (7 per cent) of the remaining 103 hips were revised. The revisions were performed because of infection (three hips), dislocation (two hips), or aseptic loosening (two hips). Of the ninety-eight hips that were not lost to follow-up or revised because of infection or dislocation, eight (8 per cent) had radiographic loosening of the acetabular component and two (2 per cent) had radiographic loosening of the femoral component. Although the prevalence of radiographic loosening of the acetabular component was four times greater than the prevalence of radiographic loosening of the femoral component, the prevalence of revision because of aseptic loosening of the acetabular component was identical to that for the femoral component (one component each). These results compared favorably with those of total hip arthroplasty with cement, performed by the same surgeon, for the treatment of other diagnoses. Loosening of the acetabular component was significantly associated with a younger age at the time of the index operation (p = 0.03) and with acetabular osteolysis (p = 0.0006). Of forty-eight hips in thirty-two patients who survived for at least ten years, 96 per cent (forty-six hips) were considered by the patients to have a satisfactory result. At the time of the latest follow-up, twenty-four (75 per cent) of the patients had no pain in the hip. Although eighteen patients (56 per cent) could walk without support at a minimum of ten years after the operation, we found that the functional results for patients who had rheumatoid arthritis were inferior to those observed for patients who had had a total hip arthroplasty with cement, performed by the same surgeon, for the treatment of other diagnoses.

Acetabulum↗

Total ankle arthroplasty: a unique design. Two to twelve-year follow-up.

We evaluated the intermediate-term results of a novel total ankle arthroplasty that includes insertion of the components without cement and arthrodesis of the tibiofibular syndesmosis as part of the operative procedure. One hundred consecutive Agility ankle replacements were performed in ninety-five patients between 1984 and 1993. At the time of follow-up, eighty-three patients (eighty-six ankles) were alive and twelve patients (fourteen ankles) had died. Five (6 per cent) of the eighty-six ankles in the living patients had been revised. Including the components that had been revised for loosening, twenty-one (twelve tibial and nine talar) components had migrated. Delayed union of the syndesmosis (twenty-eight ankles) and non-union of the syndesmosis (nine ankles) were associated with the development of lysis around the tibial component. Non-union of the syndesmosis was also associated with migration of the tibial component and circumferential radiolucency around that component. In addition to the patients who died, one patient had a resection of the implant with subsequent arthrodesis. The remaining eighty-two patients (eighty-five ankles) were the basis for the clinical evaluation in the study. The average age at the time of the procedure was sixty-three years (range, twenty-seven to eighty-one years). At the time of the most recent follow-up (range, 2.8 to 12.3 years; average, 4.8 years), forty-seven (55 per cent) of the remaining eighty-five ankles were not painful and twenty-four (28 per cent) were only mildly painful. The range of motion of the fifty-six ankles that were examined at the time of follow-up averaged 36 degrees (range, 10 to 64 degrees), and the results for seventy-nine (93 per cent) of the eighty-five ankles were satisfactory to the patients.

Adult↗

Temporal and spatial distributions of directional counterface motion at the acetabular bearing surface in total hip arthroplasty.

The motions of counterface articulation against the bearing surface of the acetabular liner strongly influence polyethylene wear debris production in contemporary total hip arthroplasty. However, the available body of relevant articular force and motion information is largely confined to resultant load excursions measured relative to instrumented femoral components, and/or to global angular motions (flexion, adduction, endorotation) of the joint. Analytical frameworks are here developed to transform such information into temporal and spatial variations of the resultant load and of the local counterface sliding velocity relative to an ordered set of discrete locations (e.g., finite element nodes) on the acetabular bearing surface. Whole-duty-cycle time histories of acetabular resultant load and counterface velocity distributions are presented for two important practical situations: human level walking gait, and a 23 degrees biaxial rocking hip simulation machine. The local counterface motions occurring in the simulator are characterized by higher velocities, smoother motion patterns, and wider directional variation than those occurring in human gait.

Acetabulum↗

Long-term results of revision total hip arthroplasty with improved cementing technique.

We performed 83 consecutive cemented revision total hip arthroplasties in 77 patients between 1977 and 1983 using improved cementing techniques. One patient (two hips) was lost to follow-up. The remaining 76 patients (81 hips) had an average age at revision of 63.7 years (23 to 89). At the final follow-up 18 hips (22%) had had a reoperation, two (2.5%) for sepsis, three (4%) for dislocation and 13 (16%) for aseptic loosening. The incidence of rerevision for aseptic femoral loosening was 5.4% and for aseptic acetabular loosening 16%. These results confirm that cemented femoral revision is a durable option in revision hip surgery when improved cementing techniques are used, but that cemented acetabular revision is unsatisfactory.

Acetabulum↗

Digital edge-detection measurement of polyethylene wear after total hip arthroplasty.

A novel digital edge-detection computer technique was developed to measure polyethylene wear after total hip arthroplasty. The new method objectively infers the margins of the component by evaluating gradients of gray-scale intensity on digitized images of the radiographs. Compared with previous methods for measurement of wear, digital edge detection substantially reduces observer subjectivity. The technique was validated directly by measuring wear artificially produced by spherical-front milling of polyethylene liners in a benchtop series. Under such conditions, digital edge detection proved 6.4 times more accurate and 7.1 times more reproducible than manual measurement with conventional circular templates. In addition, clinical application of the new digital imaging technique was illustrated in a series of forty-three patients in whom a metal-backed acetabular cup had been inserted with cement. A random-coefficients prediction algorithm was invoked to estimate long-term wear (mean late rate of wear for the cohort, 0.087 millimeter per year at a mean of 118 months after the operation) on the basis of measurements of short-term wear (mean early rate of wear for the cohort, 0.154 millimeter per year at a mean of twenty-four months).

Algorithms↗

Charnley total hip arthroplasty with use of improved techniques of cementing. The results after a minimum of fifteen years of follow-up.

Three hundred and fifty-seven consecutive Charnley total hip arthroplasties were performed in 320 patients with use of a so-called second-generation technique of cementing between July 1976 and June 1978. This technique includes use of a distal femoral intramedullary cement plug, hand-mixing of the cement, and use of a cement gun to deliver the cement into the femoral canal in a retrograde fashion. At the time of the latest follow-up evaluation, a minimum of fifteen years after the arthroplasty, 130 patients (142 hips) were still alive, 189 patients (214 hips) had died, and one patient (one hip) had been lost to follow-up. A radiograph was made for 116 (82 per cent) of the 142 hips in the 130 surviving patients. Of the 356 hips that had not been lost to follow-up, thirty-three (9 per cent) had had a revision and two (1 per cent), a Girdlestone resection arthroplasty during the follow-up period. Nineteen hips (5 per cent) were revised because of aseptic loosening of the femoral or acetabular component, or both (two hips); seven (2 per cent), because of loosening with infection; and seven (2 per cent), because of dislocation. The two resection arthroplasties were performed because of loosening with infection; both were done in patients who died before the time of the latest follow-up evaluation. Of the 142 hips in the 130 patients who were alive at a minimum of fifteen years, twenty-two (15 per cent) had been revised: fifteen (11 per cent), because of aseptic loosening; three (2 per cent), because of loosening with infection; and four (3 per cent), because of dislocation. Revision of the femoral component because of aseptic loosening (excluding components that were revised because of dislocation or infection) was performed in four (1 per cent) of the entire series of 356 hips and in three (2 per cent) of the 142 hips in the 130 patients who survived for at least fifteen years. Two of the 356 hips and two of the 142 hips had aseptic loosening of the acetabular as well as the femoral component at the time of the revision. Loosening of the femoral component, defined as aseptic loosening leading to revision or as definite or probable radiographic loosening, occurred in ten (3 per cent) of the 356 hips and in six (5 per cent) of the 116 hips for which radiographs were made at a minimum of fifteen years. The acetabular component was revised because of aseptic loosening in seventeen (5 per cent) of the entire series of 356 hips and in fourteen (10 per cent) of the 142 hips in the 130 patients who survived for at least fifteen years. The acetabular component loosened without infection in forty-one (12 per cent) of the 356 hips and in twenty-six (22 per cent) of the 116 hips for which radiographs were made at a minimum of fifteen years. In two of these patients, the femoral component was also revised. Thus, of the entire series of 356 hips, two had a revision of the femoral component alone because of aseptic loosening; fifteen, a revision of the acetabular component alone; and two, a revision of both components. Of the 142 hips in the 130 patients who survived for at least fifteen years, one was revised for loosening of the femoral component alone; twelve, for loosening of the acetabular component alone; and two, for loosening of both components. These findings demonstrate long-term durability of fixation of the femoral component but less reliable fixation of the acetabular component, even when the surgeon is experienced and improved techniques of cementing are used.

Activities of Daily Living↗