Publications and source records attributed to J J Callaghan.

At least 19 recordsLinked to original sources

Experimental and computational simulation of total hip arthroplasty dislocation.

Other than fatal pulmonary embolism and deep infection, dislocation following total hip replacement remains probably the most vexing complication to patient and surgeon. Subluxation and dislocation are complex, poorly understood phenomena. Many important questions in this area unfortunately do not lend themselves well to clinical or registry study. Appropriate realistic laboratory models have been lacking. This article synthesizes new work undertaken independently by two groups of biomechanical investigators using very different, but complimentary, methodologies to study the mechanisms of dislocation, and especially the influence of specific design and surgical variables.

Arthroplasty, Replacement, Hip↗

Dislocation after total hip arthroplasty: a single surgeon's experience.

The purpose of this article is to evaluate the dislocations that occurred in a single surgeon practice over a 26 year period. After extensive research, the authors concluded that dislocation continues to occur long after the initial arthroplasty procedure. Patients should be aware that more than a quarter of dislocations occur 2 years following surgery. Use of modular 22 millimeter components were associated with the highest dislocation rate. These components should be used very cautiously. Constrained liners have helped decrease the dislocation rate following revision for dislocation.

Aged↗

Comparison of femoral head penetration rates between cementless acetabular components with 22-mm and 28-mm heads.

Between April 1993 and July 1994, the senior author (R.C.J.) performed 151 consecutive primary total hip arthroplasties using a Harris-Galante II acetabular component and a polished Iowa femoral component. In 105 hips, 22-mm head components were used, and in 46 hips, 28-mm head components were used. Femoral head penetration into the acetabular shell was measured using digital edge detection techniques. The group average penetration for the initial 2-year bedding-in period was 0.35 mm/y for the 22-mm and 0.31 mm/y for the 28-mm head components. The long-term rate of penetration into the shell was 0.11 mm/y for the 22-mm heads and 0.17 mm/y for the 28-mm heads, a significant difference (P=.029). The dislocation rate was significantly higher, however, with the 22-mm heads (P=.001). The 22-mm components showed significantly less wear but at the expense of an increase in the prevalence of dislocation.

Acetabulum↗

Impaction allografting with cement for extensive femoral bone loss in revision hip surgery: a 4- to 8-year follow-up study.

The current study evaluates the 4- to 8-year results of 26 cemented femoral revisions with impaction allografting using a collared femoral component in cases of extensive femoral bone loss. Patients were followed prospectively and were evaluated at an average of 6.0 years after the allograft revision procedure. The average age at the time of surgery was 69.3 years. At final follow-up, 20 patients (20 hips) were living, and 6 patients (6 hips) were deceased. No femoral component rerevisions were performed for any reason in any patient, and none were radiographically loose at final follow-up. There was 1 subsided femoral component of <5 mm, 3 postoperative periprosthetic femoral fractures, and a greater trochanter nonunion rate of 32%. At the current follow-up interval, these cemented femoral revisions with impaction allografting have performed well with excellent clinical and radiographic durability in this difficult patient population. The prevalence of periprosthetic fracture is a significant concern. This study shows durable results using the impaction allografting technique in cases of severe bone loss.

Aged↗

Mobility and contact mechanics of a rotating platform total knee replacement.

Despite their increasing clinical use, mobile-bearing total knee replacements have not been well characterized biomechanically. An experimental and finite element analysis was done to assess the mobility and contact mechanics of a widely used rotating platform total knee replacement. Parameters that varied were axial load, condylar load allocation, flexion angle, and static versus dynamic loading. Similar results from the physical model and finite element model lend credence to the validity of the findings. The torque required to initiate rotation (static torque) was greater than that to sustain rotation (dynamic torque). At four times body weight axial load, peak resisting torque measured was 9.47+/-0.61 and 5.51+/-0.38 N-m, for static and dynamic torque, respectively. A 60-40 condylar load allocation produced slightly less resisting torque than the 50-50 load. For all practical purposes, the polyethylene insert rotated simultaneously with the femoral component, leading to maintenance of high contact area, desirable behavior clinically. Walking cycle simulations produced a total axial rotation range of motion of 6 degrees. The high frictional torques observed at the mobile interface may explain why a percentage of these mobile-bearings fail to rotate under routine functional load.

Biomechanical Phenomena↗

Mobile-bearing knee replacement: clinical results: a review of the literature.

Mobile-bearing knee replacements have been implanted for more than 20 years. The Oxford unicompartmental replacement and the LCS (low contact stress) total knee system have been studied extensively. Ninety-five to 97% 10-year survivorship rates of the Oxford unicompartmental replacement have been reported. Low contact stress meniscal-bearing survivorship rates of 98% at 6 years and 94.6% at 8 years have been reported. Ninety-five to 100% survivorship rates at the 11- and 12-year followup have been reported for low contact stress rotating platform knee replacements. Complications with the Oxford unicompartmental replacement include an increase in bearing dislocation and an increase in loosening rate when the components were placed in knees that had anterior cruciate ligament deficiency. Complications with the low contact stress total knee system include bearing dislocation (meniscal, rotating platform, and patellar), bearing breakage, and polyethylene wear. If mobile-bearing knee replacements are inserted with the same precision as fixed-bearing knee replacements, the results should at least be comparable. There may be some potential for an increase in durability, compared with fixed-bearing knee replacements, especially those of a modular design.

Biomechanical Phenomena↗

Prevention of dislocation after hip arthroplasty: lessons from long-term followup.

Regarding dislocation after total hip arthroplasty, prevention is worth an ounce of cure. The current authors evaluated dislocation after total hip arthroplasty during the 26-year practice of one surgeon to identify potential variables that can contribute to the prevention of dislocation. Between 1970 and 1996, dislocation after total hip replacement occurred after 7.2% of primary hip arthroplasty procedures (298 of 4164 primary hip replacements) and 11.2% of revision hip arthroplasty procedures (90 of 803 revision hip replacements). Significant findings included an increase in dislocation when 22-mm modular femoral heads were used and a decrease in dislocation after revision for dislocation when constrained liners were used. An additional finding was that 26% of first time dislocations occurred more than 2 years after surgery. Concerning prevention of dislocation, small head modular femoral components should be used cautiously, and constrained liners should be considered in complex revision cases. Patients should be counseled concerning the potential for dislocation many years after their arthroplasty.

Aged↗

Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results.

BACKGROUND: Polyethylene wear debris, and the resulting inflammatory response leading to osteolysis and loosening, is the primary mode of failure limiting the longevity of total hip replacements. Alternative bearing surfaces, including ceramic-on-polyethylene, have been investigated in an effort to decrease the amount of polyethylene wear debris. The purpose of this study was to evaluate the seventeen to twenty-one-year results of the use of ceramic-on-polyethylene total hip prostheses. METHODS: Sixty-four total hip prostheses were implanted with cement, by one surgeon, in fifty-six patients from 1978 to 1981. The average age at the index arthroplasty was sixty-nine years (range, fifty-one to eighty-four years). The components consisted of a cemented Charnley-Müller stem with a 32-mm modular alumina femoral head and a cemented all-polyethylene acetabular component. All patients who retained the index prosthesis were assessed clinically with use of Harris hip scores and were evaluated radiographically at the time of the latest follow-up. RESULTS: At the time of this latest follow-up, of the original sixty-four implants, eighteen (28%) were still in place and five (8%) had been revised. The remaining forty-one implants were in patients who had died and were functioning well until the patient's death. No patient was lost to follow-up. Of the eighteen hips with an intact prosthesis in the surviving patients, seven had an excellent clinical result; nine, a good result; and two, a fair result. One asymptomatic hip had definite radiographic evidence of femoral loosening. No hip had definite signs of acetabular loosening or evidence of osteolysis. Survivorship analysis revealed that the probability of survival of the prostheses without revision was 95% at five years, 95% at ten years, 89% at fifteen years, and 79% at twenty years. The mean linear and volumetric polyethylene wear rates were 0.034 mm/yr and 28 mm(3)/yr, respectively. There were no fractures of the ceramic heads. CONCLUSIONS: Outstanding long-term clinical and radiographic results were attained despite the use of what are now considered substandard techniques (an inferior stem design, a 32-mm head, and first-generation cementing techniques). The wear rates in this study are lower than previously reported metal-on-polyethylene wear rates and are consistent with the lowest reported in vivo ceramic-on-polyethylene wear rates. These findings support the consideration of ceramic-on-polyethylene bearing surfaces in total hip arthroplasty.

Aged↗

Revision of a cemented acetabular component to a cementless acetabular component. A ten to fourteen-year follow-up study.

BACKGROUND: Although cementless acetabular components are routinely used in revision hip surgery, few investigators have evaluated the retention and efficacy of these components in the long term. In the current study, the clinical and radiographic outcomes of a series of arthroplasties performed by one surgeon with a cementless acetabular component were assessed at a minimum of ten years. METHODS: From 1986 through 1988, sixty-one consecutive revision total hip arthroplasties were performed in fifty-five patients because of aseptic failure of one or both components of a prosthesis in which both components had been cemented. Twenty-eight patients (thirty-two hips) were alive at a mean of 12.9 years (range, 11.5 to 14.3 years) after the operation. In all of the patients, the acetabular component was revised to a porous-coated Harris-Galante component inserted without cement, and the femoral component was revised to an Iowa component affixed with contemporary cementing techniques. The hips were evaluated clinically and radiographically at a minimum of ten years subsequent to the index revision. No hips were lost to follow-up. RESULTS: None of the acetabular components required revision because of aseptic loosening. Two hips (3%) demonstrated radiographic evidence of aseptic loosening of the acetabular component. The polyethylene liner was exchanged during the follow-up period in eight hips. CONCLUSION: After a minimum of ten years of follow-up, cementless acetabular fixation in revision hip arthroplasty had produced durable results that were markedly better than those reported for acetabular fixation with cement.

Acetabulum↗

Charnley total hip arthroplasty with use of improved cementing techniques: a minimum twenty-year follow-up study.

BACKGROUND: In total hip arthroplasty, techniques for cementing the femoral component have changed over time. The purpose of the present study was to determine whether a cementing technique that includes use of a distal cement plug and retrograde filling of the femoral canal affects the fixation of the femoral component at a minimum of twenty years after the operation. METHODS: Between 1976 and 1978, the senior one of us (R.C.J.) performed 357 total hip arthroplasties with use of a Charnley flatback polished femoral stem and a contemporary cementing technique (insertion of a distal cement plug and retrograde filling of the femoral canal with cement) in 320 patients. The results after a minimum follow-up of twenty years were compared with those after 330 total hip arthroplasties performed, between 1970 and 1972, with the same femoral stem by the same surgeon with use of a hand-packing technique of cementing in 262 patients. The clinical and radiographic evaluation as well as the duration of follow-up were identical in the two groups. RESULTS: In the group managed with the contemporary cementing technique, six (1.8%) of the 336 hips that had not been lost to follow-up or revised because of infection or dislocation were revised because of aseptic loosening of the femoral component. Of the ninety-one hips in the eighty-two patients who were alive at a minimum of twenty years, five (5%) had a revision because of aseptic loosening of the femoral component. Only one hip was revised during the fifteen-to-twenty-year follow-up interval. (The revision was performed because of a fracture of the femoral component.) The rate of failure when radiographic signs of loosening were included was 4.8% (sixteen of 336 femoral components that had not been revised because of infection or dislocation) for the group managed with the contemporary cementing technique compared with 6.3% (twenty of 319 hips) in the group managed with the hand-packing technique; the difference was not significant (p = 0.40). Adequate filling of the femoral canal with cement was found to be associated with improved survival of the femoral component (p = 0.03). CONCLUSIONS: While no significant difference between the two cementing techniques could be identified, the ability to deliver adequate cement around the femoral component was more predictable with the contemporary cementing technique. In addition, the prevalence of loosening of the femoral component was low with use of either technique, a tribute to the Charnley flatback polished femoral component design.

Adult↗

Mobile-bearing knee replacement: concepts and results.

In summary, if TKRs are to be performed in patients who are younger and more active than those who had the initial procedures in the 1970s and 1980s, better wear performance is imperative for long-term durability, especially if surgeons continue to consider the versatility associated with modular knee-replacement systems to be a necessity. At least with some designs, including the Oxford knee and the LCS knee, the results after a minimum follow-up of 10 years are comparable with the best results after arthroplasty with fixed-bearing designs in terms of wear, loosening, and osteolysis (Table 7). As with fixed-bearing designs, there are additional challenges in terms of optimizing bearing-surface conformity and improving kinematics. Improvements in future designs of mobile-bearing total knee replacements should include better control of bearing mobility patterns to reduce the prevalence of the abnormal kinematic motions that have been observed in fluoroscopic evaluations.

Adult↗

Argument against use of food additives for osteoarthritis of the hip.

Food additives and other forms of alternative medicines have been embraced by the general public. Some of these compounds including glucosamine and chondroitin sulfate have shown efficacy in relieving pain associated with osteoarthritis. However, evidence is limited concerning the chondroprotective ability of these agents. More controlled studies and basic research is necessary to evaluate these claims especially because these compounds are not under regulatory control.

Complementary Therapies↗

Charnley total hip arthroplasty with cement. Minimum twenty-five-year follow-up.

BACKGROUND: This report presents the results of the senior author's initial twenty-five-year experience with the use of Charnley total hip arthroplasty with cement. The purpose of this paper was to evaluate the long-term results of total hip arthroplasty. METHODS: Between July 1970 and April 1972, the senior author (R. C. J.) performed 330 Charnley total hip replacements with cement using a hand-packing cement technique in 262 patients. Fifty-one patients (sixty-two hips) who were alive at least twenty-five years post-operatively were evaluated from a clinical standpoint with use of a standard-terminology questionnaire. The average age of this group at the time of surgery was fifty-six years (range, thirty-five to seventy-one years) compared with sixty-five years (range, twenty-one to eighty-nine years) for the entire group. All patients were evaluated for radiographic changes at the time of their most recent follow-up. Of the fifty-one patients (sixty-two hips) who were alive at least twenty-five years postoperatively, thirty-one (thirty-six hips) had a follow-up radiograph made at a minimum of twenty-five years after the surgery. The average duration of radiographic follow-up for the fifty-one patients was 22.7 years (range, two to twenty-seven years). RESULTS: Of the sixty-two hips in the fifty-one patients who were alive at least twenty-five years postoperatively, fourteen (23 percent) had been revised. Three (5 percent) had the revision because of loosening with infection; eleven (18 percent), because of aseptic loosening; and none, because of dislocation. The prevalence of revision due to aseptic loosening of the acetabular component in all 316 hips (excluding those that were lost to follow-up or that were revised for infection or dislocation) was 6 percent (eighteen hips), whereas the prevalence in the fifty-nine hips (excluding the three revised for infection) in the patients who were alive at least twenty-five years after the arthroplasty was 15 percent (nine hips). The prevalence of revision because of aseptic loosening of the femoral component in all 316 hips was 3 percent (nine hips), and the prevalence in the fifty-nine hips in the living patients was 7 percent (four hips). In the group of living patients, osteolysis occurred in Gruen zone 1 or 7 in thirty-three hips and in Gruen zones 2 through 6 in two hips. Ballooning acetabular osteolysis occurred in five hips. Of the 327 hips for which the outcome was known after a minimum of twenty-five years, 295 (90 percent) had retained the original implants until the patient died or until the most recent follow-up examination. Of the sixty-two hips in patients who lived for at least twenty-five years after the surgery, forty-eight (77 percent) had retained the original prosthesis. CONCLUSIONS: Our follow-up study at twenty-five years following Charnley total hip arthroplasty with cement demonstrates the durability of the results of the procedure. These results should provide a means for comparison with the results of newer cementing techniques as well as those associated with newer cemented and cementless hip designs.

Aged↗

Arthroplasty of the hip in patients with aplastic anemia.

BACKGROUND: Patients with aplastic anemia are now living longer and therefore are at increased risk for the development of osteonecrosis of the hip. However, studies on the results of arthroplasty for the treatment of osteoarthritis of the hip in patients with aplastic anemia are lacking. METHODS: Twenty-six primary hip prostheses (one bipolar prosthesis fixed with cement, two bipolar prostheses fixed without cement, three hybrid total hip prostheses, and twenty total hip prostheses fixed without cement) were implanted, between March 1990 and May 1992, in nineteen patients who had been diagnosed with aplastic anemia. A specific prospective protocol was followed for the perioperative transfusion of platelets and blood. Twenty-five hips were replaced because of osteonecrosis of the femoral head, and one was replaced because of a femoral neck fracture. The patients were followed prospectively, with preoperative and serial postoperative Harris hip ratings as well as radiographs, for a minimum of six years or until death. RESULTS: No patient had excessive perioperative bleeding or a postoperative infection. After a mean duration of follow-up of seventy-nine months (range, seventy-two to ninety-five months), two patients had died with the original implant in place. No patients were lost to follow-up. The mean Harris hip score was 55 points (range, 42 to 68 points) preoperatively and 87 points (range, 56 to 95 points) at the time of the latest follow-up. At the time of this writing, no hip had been revised. One patient with a bipolar prosthesis had radiographic evidence of femoral loosening and will probably require revision. A second patient had some medial protrusion of a bipolar prosthesis, with mild symptoms. All of the acetabular components that had been fixed without cement and all of the other femoral components appeared to be stable on radiographs after a minimum of seventy-two months of follow-up. CONCLUSIONS: Total hip arthroplasty can be performed safely in patients with aplastic anemia. In the present intermediate-term study, the durability of implant fixation was maintained and the clinical results demonstrated a sustained increase in function of the hip.

Adult↗

Cemented rotating-platform total knee replacement. A nine to twelve-year follow-up study.

BACKGROUND: Although the LCS (low contact stress) rotating-platform mobile-bearing knee replacement has been used extensively, there have been few intermediate or long-term clinical and radiographic follow-up studies evaluating the device. The purpose of this study was to report the nine to twelve-year results of a consecutive series of patients who had a primary total knee replacement performed with this device. METHODS: Between November 1985 and November 1988, the senior author (R. C. J.) performed 119 consecutive total knee arthroplasties in eighty-six patients with LCS rotating-platform femoral and tibial components and a Townley all-polyethylene dome patellar component. All components were fixed with cement. The average age of the patients at the time of the operation was seventy years (range, thirty-seven to eighty-eight years). Fifty-two patients (seventy-six knees) were female, and thirty-four patients (forty-three knees) were male. The patients were evaluated with clinical knee ratings and radiographic analysis nine to twelve years following the knee replacement. RESULTS: At the time of the nine to twelve-year follow-up, sixty-four patients (eighty-six knees) were alive, eighteen patients (twenty-eight knees) had died, and four patients (five knees) had been lost to follow-up. Of the 114 knees in the eighty-two patients for whom the final outcome was known, none required a reoperation and none had a dislocation of the mobile-bearing prosthesis. For the forty-five patients (sixty-six knees) who returned for final clinical and radiographic follow-up examinations at nine to twelve years, the average clinical and functional Knee Society ratings were 30 points (range, 2 to 70 points) and 44 points (range, 0 to 80 points) preoperatively and 90 points (range, 63 to 102 points) and 75 points (range, 30 to 100 points) at the final follow-up evaluation. The average Hospital for Special Surgery knee rating was 57 points (range, 28 to 80 points) preoperatively and 84 points (range, 59 to 97 points) at the final follow-up evaluation. The average active range of knee flexion was from 0 degrees (range, 0 to 10 degrees) to 102 degrees (range, 15 to 120 degrees) at the final follow-up evaluation. Seven of the sixty-six knees were painful anteriorly. There was no periprosthetic osteolysis and no evidence of loosening on follow-up radiographs. CONCLUSIONS: After nine to twelve years of follow-up, the cemented LCS rotating-platform knee replacement was found to be performing well, with durable clinical and radiographic results.

Adult↗