3D thoracoscopic ultrasound volume measurement validation in an ex vivo and in vivo porcine model of lung tumours.

The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the ultrasound images and a manual-radial segmentation technique and these were compared with the known volumes of the agar. In vitro measurements had average accuracy and precision of 4.76% and 1.77%, respectively; in vivo measurements had average accuracy and precision of 8.18% and 1.75%, respectively. The 3D thoracoscopic ultrasound can be used to accurately and reproducibly measure "tumour" volumes both in vivo and ex vivo.

Agar↗

Signal and noise transfer properties of photoelectric interactions in diagnostic x-ray imaging detectors.

Image quality in diagnostic x-ray imaging is ultimately limited by the statistical properties governing how, and where, x-ray energy is deposited in a detector. This in turn depends on the physics of the underlying x-ray interactions. In the diagnostic energy range (10-100 keV), most of the energy deposited in a detector is through photoelectric interactions. We present a theoretical model of the photoelectric effect that specifically addresses the statistical nature of energy absorption by photoelectrons, K and L characteristic x rays, and Auger electrons. A cascaded-systems approach is used that employs a complex structure of parallel cascades to describe signal and noise transfer through the photoelectric effect in terms of the modulation transfer function, Wiener noise power spectrum, and detective quantum efficiency (DQE). The model was evaluated by comparing results with Monte Carlo calculations for x-ray converters based on amorphous selenium (a-Se) and lead (Pb), representing both low and high-Z materials. When electron transport considerations can be neglected, excellent agreement (within 3%) is obtained for each metric over the entire diagnostic energy range in both a-Se and Pb detectors up to 30 cycles/mm, the highest frequency tested. The cascaded model overstates the DQE when the electron range cannot be ignored. This occurs at approximately two cycles/mm in a-Se at an incident photon energy of 80 keV, whereas in Pb, excellent agreement is obtained for the DQE over the entire diagnostic energy range. However, within the context of mammography (20 keV) and micro-computed tomography (40 keV), the effects of electron transport on the DQE are negligible compared to fluorescence reabsorption, which can lead to decreases of up to 30% and 20% in a-Se and Pb, respectively, at 20 keV; and 10% and 5%, respectively, at 40 keV. It is shown that when Swank noise is identified in a Fourier model, the Swank factor must be frequency dependent. This factor decreases quickly with frequency, and in the case of a-Se and Pb, decreases by up to a factor of 3 at five cycles/mm immediately above the K edge. The frequency-dependent Swank factor is also equivalent to what we call the "photoelectric DQE," which describes signal and noise transfer through photoelectric interactions.

Electrons↗

Dosimetric impact of image-guided 3D conformal radiation therapy of prostate cancer.

The goal of this work is to quantify the impact of image-guided conformal radiation therapy (CRT) on the dose distribution by correcting patient setup uncertainty and inter-fraction tumour motion. This was a retrospective analysis that used five randomly selected prostate cancer patients that underwent approximately 15 computed tomography (CT) scans during their radiation treatment course. The beam arrangement from the treatment plan was imported into each repeat CT study and the dose distribution was recalculated for the new beam setups. Various setup scenarios were then compared to assess the impact of image guidance on radiation treatment precision. These included (1) daily alignment to skin markers, thus representing a conventional beam setup without image guidance, (2) alignment to bony anatomy for correction of daily patient setup error, thus representing on-line portal image guidance, and (3) alignment to the 'CTV of the day' for correction of inter-fraction tumour motion, thus representing on-line CT or ultrasound image guidance. Treatment scenarios (1) and (3) were repeated with a reduced CTV to PTV margin, where the former represents a treatment using small margins without daily image guidance. Daily realignment of the treatment beams to the prostate showed an average increase in minimum tumour dose of 1.5 Gy, in all cases where tumour 'geographic miss' without image guidance was apparent. However, normal tissue sparing did not improve unless the PTV margin was reduced. Daily realignment to the tumour combined with reducing the margin size by a factor of 2 resulted in an average escalation in tumour dose of 9.0 Gy for all five static plans. However, the prescription dose could be escalated by 13.8 Gy when accounting for changes in anatomy by accumulating daily doses using nonlinear image registration techniques. These results provide quantitative information on the effectiveness of image-guided radiation treatment of prostate cancer and demonstrate that the dosimetric impact is patient dependent.

Artifacts↗

Validation of contour-driven thin-plate splines for tracking fraction-to-fraction changes in anatomy and radiation therapy dose mapping.

The goal of this study is to validate a deformable model using contour-driven thin-plate splines for application to radiation therapy dose mapping. Our testing includes a virtual spherical phantom as well as real computed tomography (CT) data from ten prostate cancer patients with radio-opaque markers surgically implanted into the prostate and seminal vesicles. In the spherical mathematical phantom, homologous control points generated automatically given input contour data in CT slice geometry were compared to homologous control point placement using analytical geometry as the ground truth. The dose delivered to specific voxels driven by both sets of homologous control points were compared to determine the accuracy of dose tracking via the deformable model. A 3D analytical spherically symmetric dose distribution with a dose gradient of approximately 10% per mm was used for this phantom. This test showed that the uncertainty in calculating the delivered dose to a tissue element depends on slice thickness and the variation in defining homologous landmarks, where dose agreement of 3-4% in high dose gradient regions was achieved. In the patient data, radio-opaque marker positions driven by the thin-plate spline algorithm were compared to the actual marker positions as identified in the CT scans. It is demonstrated that the deformable model is accurate (approximately 2.5 mm) to within the intra-observer contouring variability. This work shows that the algorithm is appropriate for describing changes in pelvic anatomy and for the dose mapping application with dose gradients characteristic of conformal and intensity modulated radiation therapy.

Algorithms↗

Feasibility of a fast inverse dose optimization algorithm for IMRT via matrix inversion without negative beamlet intensities.

A fast optimization algorithm is very important for inverse planning of intensity modulated radiation therapy (IMRT), and for adaptive radiotherapy of the future. Conventional numerical search algorithms such as the conjugate gradient search, with positive beam weight constraints, generally require numerous iterations and may produce suboptimal dose results due to trapping in local minima. A direct solution of the inverse problem using conventional quadratic objective functions without positive beam constraints is more efficient but will result in unrealistic negative beam weights. We present here a direct solution of the inverse problem that does not yield unphysical negative beam weights. The objective function for the optimization of a large number of beamlets is reformulated such that the optimization problem is reduced to a linear set of equations. The optimal set of intensities is found through a matrix inversion, and negative beamlet intensities are avoided without the need for externally imposed ad-hoc constraints. The method has been demonstrated with a test phantom and a few clinical radiotherapy cases, using primary dose calculations. We achieve highly conformal primary dose distributions with very rapid optimization times. Typical optimization times for a single anatomical slice (two dimensional) (head and neck) using a LAPACK matrix inversion routine in a single processor desktop computer, are: 0.03 s for 500 beamlets; 0.28 s for 1000 beamlets; 3.1 s for 2000 beamlets; and 12 s for 3000 beamlets. Clinical implementation will require the additional time of a one-time precomputation of scattered radiation for all beamlets, but will not impact the optimization speed. In conclusion, the new method provides a fast and robust technique to find a global minimum that yields excellent results for the inverse planning of IMRT.

Algorithms↗

Tracking the dose distribution in radiation therapy by accounting for variable anatomy.

The goal of this research is to calculate the daily and cumulative dose distribution received by the radiotherapy patient while accounting for variable anatomy, by tracking the dose distribution delivered to tissue elements (voxels) that move within the patient. Non-linear image registration techniques (i.e., thin-plate splines) are used along with a conventional treatment planning system to combine the dose distributions computed for each 3D computed tomography (CT) study taken during treatment. For a clinical prostate case, we demonstrate that there are significant localized dose differences due to systematic voxel motion in a single fraction as well as in 15 cumulative fractions. The largest positive dose differences in rectum, bladder and seminal vesicles were 29%, 2% and 24%, respectively, after the first fraction of radiation treatment compared to the planned dose. After 15 cumulative fractions, the largest positive dose differences in rectum, bladder and seminal vesicles were 23%, 32% and 18%, respectively, compared to the planned dose. A sensitivity analysis of control point placement is also presented. This method provides an important understanding of actual delivered doses and has the potential to provide quantitative information to use as a guide for adaptive radiation treatments.

Humans↗

The influence of brachytherapy dose heterogeneity on estimates of alpha/beta for prostate cancer.

The sensitivity of estimates of alpha/beta for prostate tumours to dose heterogeneity in 125I brachytherapy implants, as well as to variation in selected radiobiological parameters, is analysed. The tumour control probabilities of brachytherapy and external beam radiotherapy are equated for ranges of alpha, Tpot, RBE and external beam dose. For each combination of parameters, the equality is used to derive the value of alpha/beta. Different clinical (non-uniform) brachytherapy dose distributions, and three uniform brachytherapy dose distributions (120, 144 and 160 Gy) are used. For 'nominal' input parameter values of Tpot = 45 days, alpha = 0.2 Gy(-1), RBE = 1.4, and an external beam dose of 70 Gy, the values obtained for alpha/beta ranged between 2.1 and 12.3 Gy for all of the clinical DVHs, between 2.1 and 3.8 Gy for the better quality clinical implants and between 1.0 and 1.8 Gy for the uniform brachytherapy doses. When only 2% of the volume receiving the lowest dose is omitted from the clinical DVHs, the estimated alpha/beta values ranged between 1.4 and 2.1 Gy. When ranges of input parameters were also considered, the overall range of alpha/beta values for the clinical brachytherapy dose distributions lay between 1.1 and 12.3 Gy for the three best clinical implants, and between 0.7 and 6.3 Gy for uniform doses. We conclude that estimation of alpha/beta without taking into account dose heterogeneity and inter-patient variation may underestimate the actual value alpha/beta.

Brachytherapy↗

Monte Carlo simulations of DNA damage from incorporated cold iodine following photoelectrically induced Auger electron cascades.

Radiation-induced damage in nucleosomal DNA from Auger electron cascades due to incorporated cold IUdR has been modelled through Monte Carlo simulations. Probabilities of DNA double strand break (DSB) production following a vacancy in the K, L, M and N shells of iodine are estimated. DSB complexity from the base damage accompanying a break was also estimated. Multiple DSB events were analysed for correlated breaks due to nucleosome periodicity. The probability of an Auger cascade causing at least one DSB strongly depended on the shell in which the initial vacancy was produced. This probability was approximately 0.35 for K and L shells and fell to 0.02 for the N shell. As expected, DSBs were predominantly induced in a nucleosome containing incorporated iodine and were accompanied with extensive base damage. Analysis of multiple DSB events showed that approximately 14% of the DSBs produced following a vacancy in the L1 orbital can be interpreted as correlated with base pair separation attributable to the nucleosome periodicity. The data generated in this work provide a basis for the development of photon-activation therapy using kilovoltage X rays incident upon IUdR sensitised tumours.

Computer Simulation↗

Monte Carlo simulations and measurement of DNA damage from x-ray-triggered auger cascades in iododeoxyuridine (IUdR).

We investigated the DNA damage from Auger electrons emitted from incorporated stable iodine (127I), following photoelectric absorption of external x-rays. The effectiveness of the Auger electrons in producing DNA double-strand breaks (DSB) was determined theoretically, using Monte Carlo simulations of the radiation physics and chemistry, and was shown to be in reasonable agreement with DNA damage measured using the comet assay. The DSB yields were measured in CHO cells for 60Co (as a non-Auger-promoting radiation) and for tungsten-filtered 100 kVp x-rays capable of producing Auger electron emission. The theoretical study showed that on average, 2.5 Auger electrons were emitted for N-shell orbital vacancies and up to 10 Auger electrons were emitted from L1-shell vacancies. These Auger bursts produced approximately 0.03 DSB per N-shell vacancy and 0.3 DSB per K-shell or L-shell vacancy. The calculated yield of DSB from Auger cascades per unit dose (1 Gy) in water was approximately 1.7 for tungsten-filtered 100 kVp x-rays, assuming 20% IUdR substitution of thymidine. The comet assay yielded an experimental value of 3.6+/-1.6 per 1 Gy for the same conditions. The Monte Carlo simulations also demonstrated a high complexity of DSB produced by Auger cascades with virtually all DSB from inner shell orbitals (i.e. K, L shells) accompanied by compounded strand breakage and base damage, indicating a difficult lesion to repair. This finding agrees well with comet assay results of DNA repair, where an increase in the DSB yield in IUdR-sensitized cells was shown to persist after a time of 24 h. We conclude that Auger cascades in iodine produce a modest increase in the number of initial strand breaks of the order of 10% but the complex nature of these DSB makes them very difficult to repair or potentially prone to misrepair. The accentuated DNA damage may have major consequences for cell survival and may be exploitable in kilovoltage photon activation therapy (PAT) of tumors sensitized with iodine.

Animals↗

Operational characteristics of a prototype x-ray needle device.

A prototype x-ray needle, which emits 62.5 kVp x-rays at the tip of a 20 cm long, 4 mm diameter steel needle, has been developed by Titan Pulse Sciences Incorporated (PSI) (Albuquerque, NM) and was tested for its suitability in brachytherapy applications in comparison with a similar device by the Photoelectron Corporation. The depth dose profiles were also compared with those of two common brachytherapy sources (125I and 192Ir). The depth dose characteristics of the radiation were comparable with the two brachytherapy sources with a slightly reduced attenuation gradient. The dose rate from the x-ray needle tip was relatively isotropic at the needle tip and was continuously adjustable over the range of 0 cGy min(-1) to upwards of 62 cGy min(-1) at a reference distance of 1 cm in air. We detected a significant proportion of x-rays generated along the needle shaft, and not at the needle tip, as intended. The energy spectrum emitted from this device had a peak intensity at 21 keV and an average energy of 28 keV. The beam was attenuated in both aluminium (the first half-value layer being less than 0.1 mm) and in water (50% dose at approximately 2 mm). These studies confirm that although there is potential for a system similar to this one for clinical applications, the simplistic electron guidance used in this particular prototype device limits it to research applications. Further optimization is required in focusing and steering the electron beam to the target, improving x-ray production efficiency and using x-ray target cooling to achieve higher dose rates.

Aluminum↗

A two-source model for electron beams: calculation of relative output factors.

A two-source model for the calculation of relative output factors (ROF) for clinical applications of electron beams has been developed. The model consists of (1) an effective extended source above the final field-defining aperture (cutout) plane and (2) a source due to scattering from the aperture. Calculations are based on Fermi-Eyges theory and a pencil beam algorithm with parameters determined independently for each major scattering component. The model predicts a modified inverse square law for determining the dose rate for the electron beams. It also generalizes the "square-root method" and "one-dimensional method" that are often used clinically for ROF calculations. A computer program based on the model has been developed to calculate ROF for irregular fields. The predictions of ROF values have been compared with measurements on a Varian CLINAC 2100C/D accelerator for different cutout size, energies, applicators, and SSDs for square fields, rectangular fields, circular fields, and irregular fields. The agreement between prediction and measurement of the ROF for these wide range of conditions is generally within 1% for energies from 6 to 20 MeV. This two-source model can be used for clinical applications and it requires a minimal set of measured input data.

Algorithms↗

In-field and out-of-field effects in partial volume lung irradiation in rodents: possible correlation between early dna damage and functional endpoints.

PURPOSE: Recent observations have shown that there are regional variations in radiation response in mouse lung as measured by functional assays. Furthermore, there are both in-field and out-of-field effects in radiation-induced lung damage as observed by DNA assay in rats. The purpose of this work is: (a) to examine mice lethality data following partial volume lung irradiation to assess the possibility of directional or regional effects, (b) to evaluate the correlation between mice lethality data and DNA damage assayed by micronuclei production in rat lung, and (c) to re-interpret mice lethality considering the existence of directional effects in lung cellular response to partial volume irradiation. METHODS AND MATERIALS: The lethality data for mice, generated at the M. D. Anderson Cancer Center, Houston, and micronuclei yield data for rats obtained at Princess Margaret Hospital, Toronto, were used. A radiobiological model that allows for out-of-field and in-field effects for lung cell damage and lung response was developed. This model is based on the observation of DNA damage in shielded parts of rat lung that was assumed relevant to cell lethality and consequently overall lung response. RESULTS: While the experimental data indicated directional or regional volume effects, the applicability of dose and volume as sole predictors of lung response to radiation was found to be unreliable for lower lung (base) irradiation in mice. This conforms well to rat lung response where micronuclei were observed in shielded apical parts of lung following base irradiation. The radiobiological model, which was specifically developed to account for the lung response outside of primary irradiated volume, provides a good fit to mice lethality data, using parameters inferred from rat micronuclei data. CONCLUSION: Response to lung irradiation in rodents, in particular, elevated sensitivity to base irradiation, can be interpreted with a hypothesis of in-field and out-of-field effects for cellular response. If the existence of these effects for lung is subsequently proven in humans, it will require the incorporation of geometrical and directional information in normal tissue complication probability calculations for lung. These considerations are ignored in present approaches based only on conventional dose-volume histograms.

Animals↗

Cavity theory applied to the dosimetry of systemic radiotherapy of bone metastases.

A two-component model of an osteoblastic metastatic lesion has been developed to determine the absorbed dose delivered to soft tissue during systemic radiotherapy of osseous metastases. Doses to soft tissue from radioisotopes distributed in bone were calculated using Burlin's general cavity theory. A correction term was used to account for the absence of charged particle equilibrium within the metastatic lesion. Radiation doses for 153Sm, 186Re, 89Sr and 32P were calculated for several physiologically realistic lesion structures. Burlin's cavity weighting factor was greatest for higher energy isotopes and it decreased as the soft tissue cavity size increased. The correction for the absence of charged particle equilibrium also decreased with soft tissue pathlength, but increased with average bone pathlengths. Doses to soft tissue cavities ranged from 0.1 to 0.2 Gy MBq(-1) d(-1) for 153Sm to 0.5 to 0.6 Gy MBq(-1) d(-1) for 32P. Using the factors calculated in this work, the dose to soft tissue cavities within bone metastases can be calculated when the dose to adjacent bone has been determined, perhaps by autoradiography or electron paramagnetic resonance dosimetry. The doses calculated with this more accurate model of bone metastases demonstrate errors of 20% to 50% in previous calculations of the average dose to homogeneous metastatic lesions.

Algorithms↗

Polyvinyl alcohol-Fricke hydrogel and cryogel: two new gel dosimetry systems with low Fe3+ diffusion.

Two new Fricke dosimeter gel systems with low diffusion rates have been developed for 3D radiation dosimetry purposes. Both systems consist of a solution of 20% (by weight) polyvinyl alcohol (PVA) in a 50 mM H2SO4 solution with 0.4 mM ferrous ammonium sulphate and xylenol orange (FX). The difference in the two gels is the way that the gelation process was initiated: either by bringing the temperature to (a) +5 degrees C or (b) -20 degrees C before returning them to room temperature. These gels are termed 'hydrogel' and 'cryogel', respectively. The hydrogel is optically transparent, and can be used with either optical or MRI detection methods for dosimetric imaging. The cryogel is rubbery in texture but opaque, so its internal Fe3+ concentration can only be measured with MRI. The hydrogel's optical attenuation coefficient is linear (r2 = 0.99) with dose from 0 to 20 Gy with a sensitivity of 0.106 cm(-1) Gy(-1) (at 543 nm). In terms of MR relaxation rate, the dose response for both the hydrogel and cryogel was linear (r2 = 0.99) with a sensitivity of 0.020 s(-1) Gy(-1) (at 1.5 T). The Fe3+ diffusion coefficient (at 20 degrees C) was measured to be 0.14 mm2 h(-1), which is significantly lower than similar preparations reported for porcine gelatin or agarose. The PVA-FX gels can be stored for long periods of time before exposure to radiation, since the auto-oxidation rate was 10 times less than that of gelatin-Fricke recipes. The new gels developed in this work are a significant improvement on previous Fricke gel systems.

Calibration↗

Optimal photon energies for IUdR K-edge radiosensitization with filtered x-ray and radioisotope sources.

The purpose of this work is to determine the most physically effective radiation energy for K-edge absorption of x- or gamma-rays by iododeoxyuridine (IUdR) on Chinese hamster ovary (CHO) cells. Brachytherapy sources (Sm-145, I-125, Yb-169 and Am-241) and x-ray beams (30 kVp, 100 kVp and 100 kVp with gold, gadolinium, lead or tungsten filtration) were investigated for their preferential absorption qualities by IUdR sensitized DNA. The 30 kVp, 100 kVp and 100 kVp with tungsten filtration were then used to irradiate CHO cells, with or without IUdR incorporation (i.e. 10(-5) M of IUdR for 3 days). Radiation absorption calculations were performed to determine the increase in energy absorption in DNA with and without IUdR incorporated. In order to measure the in vitro biological effects of K-edge absorption, cell survival experiments were performed. The radiation physics calculations yielded an iodine dose enhancement ratio (DER) of 1.4+/-0.15. 1.8+/-0.15 and 2.7+/-0.15 for the 30 kVp, 100 kVp and tungsten filtered 100 kVp respectively, for 18% IUdR replacement of thymidine in DNA. The corresponding cell sensitization enhancement ratios (SER), determined from the cell survival assay, were determined to be 1.24+/-0.2, 1.8+/-0.2 and 2.3+/-0.3 for the 30 kVp, 100 kVp and tungsten filtered 100 kVp respectively, for cells with 18+/-2% IUdR incorporation. These SER values are in reasonable agreement with the DER values of 1.4, 1.8 and 2.7. From these radiation calculations and radiobiology experiments we confirm that using x-radiation energies above the K-edge of iodine (33.2 keV) can have a significant effect on cell survival. This effect is due mainly to the increase in the local dose to the DNA for IUdR-sensitized cells compared with the normal DNA which lacks the iodine contrast agent. Our results support the clinical application of IUdR and low-energy brachytherapy, perhaps using new technologies such as the x-ray needle or new isotopes such as Yb-169.

Americium↗

Feasibility of reading LiF thermoluminescent dosimeters by electron spin resonance.

Lithium fluoride is a commonly used solid state dosimeter. During irradiation, electrons and holes become trapped in crystal imperfections; thermoluminescence dosimetry measures their thermally induced recombination. Electron paramagnetic resonance (EPR) spectroscopy can be used to measure the resonant absorption of microwaves by the unpaired electrons trapped in LiF. In an effort to extend the use of LiF dosimeters to smaller sizes and to the harsh environments encountered in internal dosimetry, EPR was evaluated as an alternative technique to read the radiation dose delivered to TLD-100 dosimeters. TLD-100 rods were irradiated with a 60Co source to doses of 10 Gy to 100 Gy. A radiation-induced signal (with a g-value of 2.002) could be detected only at liquid nitrogen temperatures at doses above 20 Gy. The EPR spectrum of irradiated LiF contains three components, one of which correlates positively with dose. However, the low sensitivity of the technique, and difficulty in interpreting the EPR spectrum from polycrystalline dosimeters, preclude its use as a dosimetry technique.

Crystallization↗

Optical CT reconstruction of 3D dose distributions using the ferrous-benzoic-xylenol (FBX) gel dosimeter.

In recent years, magnetic-resonance imaging of gelatin doped with the Fricke solution has been applied to the direct measurement of three-dimensional (3D) radiation dose distributions. However, the 3D dose distribution can also be imaged more economically and efficiently using the method of optical absorption computed tomography. This is accomplished by first preparing a gelatin matrix containing a radiochromic dye and mapping the radiation-induced local change in the optical absorption coefficient. Ferrous-Benzoic-Xylenol (FBX) was the dye of choice for this investigation. The complex formed by Fe3+ and xylenol orange exhibits a linear change in optical attenuation (cm-1) with radiation dose in the range between 0 and 1000 cGy, and the local concentration of this complex can be probed using a green laser light (lambda = 543.5 nm). An optical computed tomography (CT) scanner was constructed analogous to a first-generation x-ray CT scanner, using a He-Ne laser, photodiodes, and rotation-translation stages controlled by a personal computer. The optical CT scanner itself can reconstruct attenuation coefficients to a baseline accuracy of < 2% while yielding dose images accurate to within 5% when other uncertainties are taken into account. Optical tomography is complicated by the reflection and refraction of light rays in the phantom materials, producing a blind spot in the transmission profiles which, results in a significant dose artifact in the reconstructed images. In this report we develop corrections used to reduce this artifact and yield accurate dosimetric maps. We also report the chemical reaction kinetics, the dose sensitivity and spatial resolution (< 1 mm3) obtained by optical absorption computed tomography. The article concludes with sample dose distributions produced by "cross-field" 6 MV x-ray beams, including a radiosurgery example.

Benzoic Acid↗

Radioactivity measurements of ytterbium-169 brachytherapy sources.

Ytterbium-169 is being considered as a new radiation source for brachytherapy applications. This radioisotope emits photons with energies ranging from 50 to 308 keV (average energy 93 keV) and decays with a half life of 32 days. For these reasons, it is believed to offer radiological and radiobiological advantages over some other isotopes currently in use. One impediment to widespread clinical use of this isotope is the determination of source strength in units of air kerma rate [cGy h-1]. The source strength can be measured directly with an ion chamber or calculated indirectly from the source radioactivity [Bq] with corrections for encapsulation. Our attempts to reconcile these two approaches have led to the development of a spectrometric technique for determining the radioactivity of ytterbium-169 brachytherapy seeds. A High Purity Germanium (HPGe) spectrometer is used to count the 307.7 keV photon emitted within a defined solid angle. The intrinsic photopeak efficiency of the detector was determined by Monte Carlo simulation followed by experimental verification with an activity-calibrated europium-152 source. Finally, the HPGe system has been used to calibrate a re-entrant ionisation chamber, allowing routine of Ytterbium source activity for clinical applications.

Brachytherapy↗