Search PubMed⌕ Search

Biomedical subjects

J I Curry

Publications and source records attributed to J I Curry.

22 records · Page 2Linked to original sources

Detection and identification of Mycobacterium tuberculosis directly from sputum sediments by Amplicor PCR.

Sputum specimens received for the diagnosis of tuberculosis or other mycobacterial infections were tested by a PCR-based assay and culture techniques. Results of the PCR assay (Amplicor Mycobacterium tuberculosis Test) were compared with results of standard culture techniques with cultures held for 6 weeks. One thousand nine specimens were included: 301 retrospective specimens (frozen at -70 degrees C and later tested by PCR) and 708 prospective specimens (tested within 1 day of processing). One hundred sixty-two (16%) of the specimens were culture positive for M. tuberculosis; 83 (51%) of these were also fluorochrome stain positive. The sensitivity and specificity of the Amplicor PCR compared with those of culture were 83% (134 of 162 specimens) and 97% (800 of 827 specimens), respectively. The sensitivity for fluorochrome stain-positive specimens was 99%, and that for fluorochrome stain-negative specimens was 66%. The great majority of the 28 PCR-negative, culture-positive specimens were low positives; 27 were smear negative and 19 contained < 100 CFU of M. tuberculosis per ml. The 27 PCR-positive, culture-negative specimens included 24 that were positive by repeat testing by alternate primer PCR and were from patients with tuberculosis on antimicrobial therapy. With these considered culture misses, the final sensitivities of PCR and culture were 85, and 87%, respectively, while the specificities were 99.6 and 100%, respectively. After normal laboratory processing of sputum specimens, the Amplicor PCR assay can be completed in 8 h. Thus, it is possible to have results available within 10 h of specimen submission.

Fluorescent Dyes↗

Detection and identification of Mycobacterium tuberculosis directly from sputum sediments by amplification of rRNA.

Seven hundred fifty-eight processed sputum sediments received for the diagnosis of tuberculosis or other mycobacterial infections were tested by utilizing a rRNA target amplification assay and traditional culture techniques. The results from the rRNA target amplification assay (Gen-Probe Amplified Mycobacterium Tuberculosis Direct Test), available in 5 h, were compared with the results from standard culture techniques held for 6 weeks. A total of 119 specimens (16%) were culture positive for Mycobacterium tuberculosis. Overall sensitivity, specificity, positive predictive value, and negative predictive value were 82, 99, 97, and 96%, respectively, for the Gen-Probe assay; 88, 100, 100, and 97%, respectively, for culture; and 53, 99.8, 99.6, and 91%, respectively, for fluorochrome stain. The Gen-Probe assay employs the isothermal enzymatic amplification of M. tuberculosis complex rRNA followed by detection of the amplicon with an acridinium ester-labeled DNA probe. This assay has the potential of reducing the time for diagnosis of tuberculosis to 1 day.

Gene Amplification↗

Evaluation of the 7-h membrane filter test for quantitation of fecal coliforms in water.

The 7-h fecal coliform (FC) test for detection of FC organisms in water was evaluated to establish its validity and usefulness for emergency and disaster situations. The waters tested consisted of routine samples collected for public health surveillance and enforcement purposes. A total of 984 water samples from throughout California were assayed. These included samples from coastal salt waters, rivers, canals, and reservoirs, in addition to potable and miscellaneous freshwater sources. A portion of each sample was tested concurrently by both the 7-h FC test and the most-probable-number FC five-tube test. The 7-h FC test samples were incubated for 7 to 7.25 h at 41.5 degrees C. Overall, greater than 90% agreement was obtained between the methods in determining whether the water quality was acceptable or unacceptable. Statistical analysis of the 984 samples confirmed that the 7-h FC method was a suitable alternative to the most-probable-number FC method for evaluation of freshwater samples. During emergencies or disasters, the 7-h FC test could provide a means for detection of fecal contamination of water with results available in less than 1 day.

Disasters↗

Effect of holding temperature on isolation of Neisseria gonorrhoeae.

The effect of holding temperature on the recovery of Neisseria gonorrhoeae was studied. From 300 specimens tested, Thayer-Martin medium plates inoculated and incubated in the presence of CO2 at 35, 22, and 4 degrees C for 24 h before incubation at 35 degrees C yielded 100, 96, and 95% of all isolates ultimately recovered from 82 positive specimens. Although there was a decrease in the quantity of organisms recovered, initial incubation of specimens under refrigeration or at room temperature yielded greater than or equal to 95% of the positive specimens.

Culture Media↗