At least 19 recordsLinked to original sources

Comparison between liquid chromatography-time of-flight mass spectrometry and selected reaction monitoring liquid chromatography-mass spectrometry for quantitative determination of idoxifene in human plasma.

This study compares HPLC electrospray time-of-flight mass spectrometry and selected reaction monitoring (SRM) LC-MS for high throughput quantitative determination of a small molecule drug in biological samples. A high throughput LC-MS method was developed for quantitatative determination of idoxifene in human plasma and the evaluation was accomplished with the cross-validation of the developed LC-MS method between the time-of-flight mass spectrometer, and a triple quadrupole mass spectrometer operated in the SRM mode. A simple one-step semi-automated 96-well liquid-liquid extraction procedure was used to prepare 96 samples in approximately 30 min and a rapid gradient was used to shorten the LC run time. Time-of-flight mass spectrometry provides acquisition of full-scan mass spectra and extracted ion current chromatograms, which may be extracted from the total ion current chromatogram for peak area determination. The limit of quantitation for idoxifene in human plasma obtained with the time-of-flight mass spectrometer was 5 ng/ml based on 100-microl aliquots of human plasma, and the linear dynamic range was from 5 ng/ml to 2000 ng/ml. The quantitative LC-MS results from the time-of-flight mass spectrometer demonstrated that precision did not exceed 7.1% and accuracy did not exceed 1.7% with reference to quality control samples at three concentration levels in replicates of six. In contrast, the limit of quantitation for idoxifene in human plasma using a tandem triple quadrupole mass spectrometer was 0.5 ng/ml with a linear dynamic range to 1000 ng/ml. The results from the triple quadrupole instrument show that the precision did not exceed 2.2% and accuracy did not exceed 2.9%. The overall results suggest time-of-flight mass spectrometry may be a viable technique for high throughput bioanalytical work for the quantitative determination of a representative small molecule drug in the low ng/ml range in human plasma.

Calibration↗

A polymeric microfluidic chip for CE/MS determination of small molecules.

A polymeric microfluidic chip made of Zeonor 1020 was fabricated using conventional embossing techniques to perform capillary electrophoresis for selected ion monitoring and selected reaction monitoring mass spectrometric detection of small molecules. A silicon master was microfabricated using photolithographic and dry etching processes. The microfluidic channel was embossed in the plastic from a silicon master. The embossed chip was thermally bonded with a Zeonor 1020 cover to form an enclosed channel. This channel (60-microm width, 20-microm depth, 2.0- and 3.5-cm length) provided capillary electrophoresis (CE) separation of polar small molecules without surface treatment of the polymer. A microsprayer coupled via a microliquid junction provided direct electrospray mass spectrometric detection of CE-separated components. An electric field of 0.5-2 kV/cm applied between the microsprayer and a separation buffer reservoir produced a separation of carnitine, acylcarnitine, and butylcarnitine with separation efficiencies ranging from 1,650 to 18,000 plates. Injection quantities of 0.2 nmol of these compounds produced a separation of the targeted polar small molecules without surface treatment of the polymer-abundant ion current signals and baseline separation of these compounds in less than 10 s. These results suggest the feasibility of polymeric chip-based devices for ion spray CE/MS applications.

Acetylcarnitine↗

Chip-based quantitative capillary electrophoresis/mass spectrometry determination of drugs in human plasma.

A chip-based capillary electrophoresis/mass spectrometry (CE/MS) system is described for the on-chip separation and coupled electrospray detection of selected small drug molecule compounds. These studies include the quantitative determination of carnitine and acetylcarnitine in analytical standard solutions as well as imipramine and desipramine in fortified human plasma samples. A clinical human plasma sample was also analyzed following the normal administration of desipramine to a volunteer, and the parent drug was determined using the described chipbased CE/MS technique. In each instance, stable isotope-incorporated internal standards were used. The chip-based CE system was microfabricated from glass and coupled to a micro ion spray device constructed in-house. The atmospheric pressure ionization system employed in this work was a PE Sciex API III tandem triple quadrupole system operated in the selected ion monitoring (SIM) mode. The results from the work reported here demonstrate the feasibility for carrying out rapid (30 s) chipbased quantitative CE/MS determinations of samples containing small-molecule compounds. Using SIM CE/ MS techniques, the described API III quadrupole system provided acceptable ion current electropherograms from subpicomole levels of the targeted compounds loaded onto the chip. The corresponding electropherograms for the standard solution of carnitines at the 1-500 microg/mL level were obtained via SIM CE/MS techniques (R2 > 0.99). In addition, analyses of fortified samples of imipramine desipramine were measured relative to their corresponding d3 internal standards to obtain calibration curves ranging from 5 to 500 microg/mL in human plasma (R2 > 0.99). The intra-assay precision ranged from 4.1 to 7.3% RSD. The intra-assay accuracy ranged from 94.0 to 104%. These results demonstrate the feasibility for on-chip CE separation and electrospray mass spectrometric determination in applications for bioanalytical measurements for these important compounds in synthetic mixtures and human plasma extracts.

Acetylcarnitine↗

A four-column parallel chromatography system for isocratic or gradient LC/MS analyses.

A novel approach to parallel liquid chromatography/ tandem mass spectrometry (LC/MS/MS) analyses for pharmacokinetic assays and for similar quantitative applications is presented. Modest modifications render a conventional LC/MS system capable of analyzing samples in parallel. These modifications involve the simple incorporation of three valves and four LC columns into a conventional system composed of one binary LC pumping system, one autosampler, and one mass spectrometer. An increase in sample throughput is achieved by staggering injections onto the four columns, allowing the mass spectrometer to continuously analyze the chromatographic window of interest Using this approach, the optimized run time is slightly greater than the sum of the widths of the desired peaks. This parallel chromatography unit can operate under both gradient and isocratic LC conditions. To demonstrate the utility of the system, atorvastatin, five of its metabolites, and their deuterated internal standards (IS) were analyzed using gradient elution chromatography conditions. The results from a prestudy assay evaluation (PSAE) tray of standards and quality control (QC) samples from extracted spiked human plasma are presented. The relative standard deviation and the accuracy of the QC samples did not exceed 8.1% and 9.6%, respectively, which is well within the acceptance criteria of the pharmaceutical industry. For this particular analysis, the parallel chromatography system decreased the overall run time from 4.5 to 1.65 min and, therefore, increased the overall throughput by a factor of 2.7 in comparison to a conventional LC/MS/MS analytical method.

Journal Article↗

A 384-well solid-phase extraction for LC/MS/MS determination of methotrexate and its 7-hydroxy metabolite in human urine and plasma.

A solid-phase extraction procedure, in a 384-well format, has been developed for methotrexate and its primary metabolite, 7-hydroxymethotrexate, in human urine and plasma. This format has not been utilized previously for solid-phase extraction of drugs from biological fluids. The 384-well plates contained a C-18 stationary phase bonded to silica particles which are incorporated into a glass-fiber membrane. Methotrexate and 7-hydroxymethotrexate have been quantified across the curve range of 1 to 50 microg/mL and 50 to 1000 ng/mL, respectively, in urine and from 5 to 250 ng/mL and 5 to 100 ng/mL, respectively, in plasma. Both analytes are quantified by linear regression using 20-microL sample aliquots. Experiments to evaluate the influence of particle size, elution volume, and injection volume on signal intensity were conducted and are reported, along with the results of experiments examining cross contamination between wells. Recovery was determined to be > or = 95% from urine. Results from a run of 384 samples analyzed over a 14-h period indicate that 384-well SPE can be successfully utilized to increase analytical run sizes and sample throughput for LC/MS/MS determination of small drug molecules in biological samples.

Chromatography, Liquid↗

Chip-based capillary electrophoresis/mass spectrometry determination of carnitines in human urine.

A chip-based capillary electrophoresis/mass spectrometry (CE/MS) system is described for the CE separation and on-line electrospray detection of carnitine and selected acylcarnitines from mixtures of analytical standards as well as extracts of fortified human urine. Chip-based CE/MS experiments in two different laboratories were carried out using a triple-quadrupole mass spectrometer and a quadrupole time-of-flight (QTOF) mass spectrometer, respectively. The glass chips used with both systems were comparably equipped with a microfabricated capillary electrophoresis (CE) channel but with different electrosprayers. The quadrupole chip-based CE/MS experiments employed a miniature coupled microsprayer, which allowed coupling of the microelectrospray process via a micro liquid junction at the exit of the CE capillary channel. Selected ion monitoring (SIM) CE/MS experiments were employed for all of the quadrupole CE/MS work. The QTOF CE/MS full-scan single MS and MS/MS experiments were carried out in another laboratory using accurate mass measurement TOF mass spectrometry techniques. The electrospray process that was employed with the QTOF system differed in that an inserted nanoelectrospray capillary needle was carefully affixed into a flat-bottomed hole that was aligned with the CE channel exit orifice. SIM CE/MS using the described quadrupole system provided acceptable ion current electropherograms from fmole levels from analytical standard solutions of carnitine and acylcarnitines that were manually injected (loaded) onto the chip. In addition, the corresponding electropherograms for human urine fortified with the target carnitine and acylcarnitines at a 10-20 microg/mL (35-124 microM) level were obtained via SIM CE/MS techniques. The measured CE separation efficiency for the SIM CE/MS electropherograms was determined to be 2860 plates (peak width at half-height method or N = 5.54(T/WO.5(2)), and carnitine and three acylcarnitines were separated in less than 48 s. In contrast, using quadrupole-TOF technologies, the same samples could be diluted by a factor of 2-4 to obtain a comparable detector response for the target compounds. In the full-scan, single mass analyzer mode (m/z 150-500), the CE separation efficiency was measured to be 2600 plates, but mass measurement accuracy was less than 5.0 ppm for the quaternary cations. In the CE/MS/MS mode, full-scan collision-induced dissociation (CID) mass spectra were obtained with a mass accuracy of < or =10 ppm for the higher mass ions and < or =27 ppm for the lower mass product ions. These results demonstrate the feasibility for on-chip CE separation and electrospray mass spectrometric detection for these important compounds in synthetic mixtures, as well as in human urine extracts.

Carnitine↗

Electrospray device for coupling microscale separations and other miniaturized devices with electrospray mass spectrometry.

A miniaturized ion sprayer device is described which is suitable for coupling with chip-based analytical separation devices, multiwell plates, or surfaces containing residues of prepared samples. Two versions of a similar device are described. A "microsprayer" device suitable for coupling to the terminal edge of a capillary electrophoresis (CE) chip is constructed from modified 1/16-in. HPLC fittings. This microsprayer employs a free-standing liquid junction formed via continuous delivery of a flow (2-6 microL/min) of suitable solvent which carries the CE effluent through a pneumatically assisted electrospray (ion spray) needle positioned in front of an atmospheric pressure ionization (API) mass spectrometer. A related but larger "minisprayer" device is also described which employs the same features as the microsprayer, but with an extended sampling capillary tube which can reach into the depths of 96-, 384-, and 1536-multiwell plates containing either sample solutions or dried sample residues. The minisprayer may be positioned in front of an API ion sampling orifice and the multiwell plate positioned stepwise from sample to sample for analysis of trace samples contained in the wells. The resulting infusion-ion spray mass spectrometric analyses can provide sequential analysis of previously prepared biological samples containing small drug compounds, proteins, and related compounds. This same device is also shown to be useful for sampling from a surface containing trace level compounds of biological interest. Results are shown that demonstrate microscale separations and selected ion monitoring (SIM) capillary electrophoresis/mass spectrometry (CE/MS) detection of berberine and palmatine using the microsprayer. SIM ion spray determination of a 2 ng/microL solution of berberine contained as a dry residue in the bottom of a 384-well plate as well as full-scan electrospray mass spectra for low-picomole levels of cytochrome c contained in a 1536-well microtiter plate are shown. The respective micro- and minisprayer devices provide a simple yet effective means of transferring trace-level samples either from a microscale or chip-based separation device as well as samples contained in multiwell plates which are increasingly employed in high-throughput applications in the pharmaceutical industry.

Journal Article↗

Application of atmospheric pressure ionization time-of-flight mass spectrometry coupled with liquid chromatography for the characterization of in vitro drug metabolites.

Atmospheric pressure ionization time-of-flight mass spectrometry coupled with high-performance liquid chromatography was used to characterize the in vitro metabolites of glyburide. Metabolic products formed in vitro by human microsomes were separated using a C18 column with gradient elution at a flow rate of 200 microL/min without postcolumn splitting. In-source collision-induced dissociation (CID) by automated nozzle potential switching was employed to obtain both abundant protonated molecules and characteristic fragments whose accurate masses were measured simultaneously by internal mass calibration, performed by continuous postcolumn infusion of two reference standards. The mass errors were within 9 ppm for all ions measured, whose abundance was greater than 5%, relative to the most abundant isotopic "A" ion. Exact mass differences between the parent drug and metabolite(s) were determined and these values corresponded to a unique elemental composition. The elemental compositions of all metabolite fragment ions were generated based upon the known compositional elements of the protonated molecule. The structures of metabolites and their fragment ions were proposed based on the determined elemental composition and in-source CID spectra. The elemental composition and fragmentation pathways of four cyclohexyl hydroxylation metabolites and one ethylhydroxy metabolite are discussed.

Animals↗

Quantitative liquid chromatographic-tandem mass spectrometric determination of reserpine in FVB/N mouse plasma using a "chelating" agent (disodium EDTA) for releasing protein-bound analytes during 96-well liquid-liquid extraction.

A sensitive, specific, accurate and reproducible analytical method employing a divalent cation chelating agent (disodium EDTA) for sample treatment was developed to quantitate reserpine in FVB/N mouse plasma. Samples pretreated with 40 microl of 2% disodium EDTA in water were extracted by a semi-automated 96-well liquid-liquid extraction (LLE) procedure to isolate reserpine and a structural analog internal standard (I.S.), rescinnamine, from mouse plasma. The extracts were analyzed by turbo ionspray liquid chromatography-tandem mass spectrometry (LC-MS-MS) in the positive ion mode. Sample preparation time for conventional LLE was dramatically reduced by the semi-automated 96-well LLE approach. The assay demonstrated a lower limit of quantitation of 0.02 ng/ml using 0.1-ml plasma sample aliquots. The calibration curves were linear from 0.02 to 10 ng/ml for reserpine. The intra- and inter-assay precision of quality control (QC) samples ranged from 1.75 to 10.9% for reserpine. The intra- and inter-assay accuracy of QC samples ranged from -8.17 to 8.61%. Reserpine and the I.S. were found to be highly bound to FVB/N mouse plasma protein. This is the first report of disodium EDTA employed as a special protein-bound release agent to recover protein-bound analytes from plasma. These matrix effects and the effects of pH in the HPLC mobile phase on the sensitivities of LC-MS-MS are discussed in this paper.

Animals↗

Bioanalytical high-throughput selected reaction monitoring-LC/MS determination of selected estrogen receptor modulators in human plasma: 2000 samples/day.

The high-throughput determination of small molecules in biological matrixes has become an important part of drug discovery. This work shows that increased throughput LC/MS/MS techniques can be used for the analysis of selected estrogen receptor modulators in human plasma where more than 2000 samples may be analyzed in a 24-h period. The compounds used to demonstrate the high-throughput methodology include tamoxifen, raloxifene, 4-hydroxytamoxifen, nafoxidine, and idoxifene. Tamoxifen and raloxifene are used in both breast cancer therapy and osteoporosis and have shown prophylactic potential for the reduction of the risk of breast cancer. The described strategy provides LC/MS/MS separation and quantitation for each of the five test articles in control human plasma. The method includes sample preparation employing liquid-liquid extraction in the 96-well format, an LC separation of the five compounds in less than 30 s, and selected reaction monitoring detection from low nano- to microgram per milliter levels. Precision and accuracy are determined where each 96-well plate is considered a typical "tray" having calibration standards and quality control (QC) samples dispersed through each plate. A concept is introduced where 24 96-well plates analyzed in 1 day is considered a "grand tray", and the method is cross-validated with standards placed only at the beginning of the first plate and the end of the last plate. Using idoxifene-d5 as an internal standard, the results obtained for idoxifene and tamoxifen satisfy current bioanalytical method validation criteria on two separate days where 2112 and 2304 samples were run, respectively. Method validation included 24-h autosampler stability and one freeze-thaw cycle stability for the extracts. Idoxifene showed acceptable results with accuracy ranging from 0.3% for the high quality control (QC) to 15.4% for the low QC and precision of 3.6%-13.9% relative standard deviation. Tamoxifen showed accuracy ranging from 1.6% to 13.8% and precision from 7.8% to 15.2%. The linear dynamic range for these compounds was 3 orders of magnitude. The limit of quantification was 5 and 50 ng/ mL for tamoxifen and idoxifene, respectively. The other compounds in this study in general satisfy the more relaxed bioanalytical acceptance criteria for modern drug discovery. It is suggested that the quantification levels reported in this high-throughput analysis example are adequate for many drug discovery and related early pharmaceutical studies.

Chromatography, Liquid↗

Atmospheric pressure ionization time-of-flight mass spectrometry coupled with fast liquid chromatography for quantitation and accurate mass measurement of five pharmaceutical drugs in human plasma.

The quantitative determination and accurate mass measurement of five tricyclic amine pharmaceutical drugs (doxepin, desipramine, imipramine, amitriptyline and trimipramine) fortified in human plasma within a per sample run time of 18 s was accomplished by atmospheric pressure ionization (API) time-of-flight (TOF) mass spectrometry using a turboIonspray liquid chromatography/mass spectrometry (LC/MS) interface coupled with high-performance liquid chromatography (HPLC). The relatively short HPLC separation (18 s) was achieved using a short C18 column (15 x 2.1 mm i.d.) with a high aqueous mobile phase maintained at a flow-rate of 1.4 ml min(-1). An acquisition speed of 0.2 s per spectrum accommodates these fast separation conditions. This method employs a one-step liquid-liquid extraction procedure to isolate the five tricyclic amines from biological matrix components The overall extraction recovery was 75% for desipramine and >90% for the other four tricyclic amines. The lower level of quantitation was 1-2 ng ml(-1) for each compound. The calibration curve was linear from 2 to 100 ng ml(-1) for desipramine and from 1 to 50 ng ml(-1) for the other four tricyclic amines. A deuterated internal standard, imipramine-d3, was used for all five tricyclic amines. Acceptable intra- and inter-assay precision (1.0-17.7%) and accuracy (0.2-14.5%) were obtained. The linear dynamic range was extended to 200 based on a software upgrade for correcting ion current detection saturation. The accurate masses of the five tricyclic amines were determined by on-line LC/TOFMS analyses of biological extracts using two-point internal mass calibration. This was done by infusing a reference standard, Jeffamine D230, post-column into the HPLC effluent. All results showed a mass error not greater than 9 ppm for all the target compounds. These results were obtained from both synthetic mixtures when as little as 100 pg were injected or extracts of spiked human plasma samples with analytical concentration as low as 5 ng ml(-1). The factors influencing accurate mass measurements are discussed.

Antidepressive Agents, Tricyclic↗

Determination of carnitine and acylcarnitines in biological samples by capillary electrophoresis-mass spectrometry.

Free carnitine and acylcarnitines (carnitine esters) play an important role in the metabolism of fatty acids. Metabolic disorders can be detected by abnormal levels of these compounds in biological fluids. Capillary electrophoresis-mass spectrometry has the advantage of combining an efficient separation technique with highly selective detection. Therefore, we have developed a method for the determination of carnitine and several of its esters implementing electrospray capillary electrophoresis-mass spectrometry in the positive ion selected reaction monitoring mode. A sheath-flow interface with a mixture of 2-propanol or methanol, water and acetic acid as sheath liquid and nitrogen as nebulizing gas was used. The zwitterionic analytes migrated as cations in the applied electric field using ammonium acetate-acetic acid or formic acid electrolytes. Separations were performed in aqueous, mixed organic-aqueous and non-aqueous media. The influence of the electrolyte composition on the separation efficiency was investigated. The electrospray conditions have been optimized regarding ion current stability and sensitivity. Ammonium acetate (10 mmol/l)-0.8% formic acid in water or 6.4% formic acid in acetonitrile-water (1:1) were used as running buffers for the determination of carnitine and acylcarnitines in human biological samples. Methanol extracts of dried blood spots were analyzed as well as urine and plasma following sample preparation via solid-phase or liquid-liquid extraction. Recoveries approaching 100% were achieved depending on the analytes and sample preparation procedures employed. Endogenous carnitine and acetylcarnitine were determined at concentrations between 2.7 and 108 nmol/ml in normal human urine and plasma. Other acylcarnitines were detected at levels of below the limit of detection to 12 nmol/ml. Good precision (0.8 to 14%) and accuracy (85 to 111%) were obtained; the achieved limits of quantitation (0.1 to 1 nmol/ml) are sufficient to characterize carnitine and acylcarnitine levels occurring as markers for metabolic disorders.

Carnitine↗

Fast liquid chromatographic-mass spectrometric determination of pharmaceutical compounds.

We present fast LC-MS-MS analyses of multicomponent mixtures containing flavones, sulfonamides, benzodiazepines and tricyclic amines. Using a short microbore HPLC column with small particle size, five to eight compounds were partially resolved within 15 to 30 s. TurboIonSpray and atmospheric pressure chemical ionization interfaces were well suited to tolerate the higher eluent flow-rates of 1.2 to 2 ml/min. The methods were applied to biological sample matrices after clean-up using solid-phase or liquid-liquid extraction. Good precision and accuracy (average 8.9 and 97.7%, respectively) were achieved for the determination of tricyclic amines in human plasma. Benzodiazepines were determined in human urine with average precision of 9% and average accuracy of 95% for intra- and inter-assay. Detection limits in the low ng/ml range were obtained. An example for 240 injections per hour of demonstrated the feasibility of rapid LC-MS-MS analysis.

Amines↗

Quantitative and qualitative determination of estrogen sulfates in human urine by liquid chromatography/tandem mass spectrometry using 96-well technology.

A sensitive and robust method to determine five estrogen sulfates in human urine has been developed employing high-throughput solid-phase extraction with 96-well technology, and HPLC coupled with negative turbo ion spray tandem mass spectrometry in the selected reaction monitoring mode. The five estrogen sulfates determined include three major endogenous estrogen sulfates in the human, estrone 3-sulfate (E1-3S), estriol 3-sulfate (E3-3S), and 17 beta-estradiol 3-sulfate (E2-3S), and two biochemical synthetic estrogen sulfates, 17 beta-estradiol 17-sulfate (E2-17S) and 17 beta-estradiol 3,17-disulfate (E2-3,17S). For E2-3,17S, E3-3S, and E2-17S, external standard calibration was used for quantitation, and for the remaining two compounds, internal standard calibration using a stable isotopic labeled internal standard was employed. A total of 96 samples may be prepared with 96-well C18 extraction disk plate techniques performed by a robot within 25 min including the time for evaporation of solvent. The lower level of quantitation (LOQ) for these estrogen sulfates in human urine was determined at 0.2 ng/mL based on 100-microL aliquots of human urine using the optimum tuning parameters for each individual selected precursor ion/product ion transition. The assay was validated with a linear concentration range of 0.2-200 ng/mL, and the interassay accuracy, intraassay precision, and interassay precision do not exceed 8.6%, 12%, and 12%, respectively, by analysis of quality control samples at five concentration levels including the LOQ of 0.2 ng/mL, from four 96-well plates. The target endogenous test articles were qualitatively determined by comparing the full-scan LC/MS/MS mass spectra and retention time in test samples and reference standards. The LOQ is significantly improved compared to previous reports for the targeted compounds using LC/MS/MS. The described simple and automated sample preparation procedure recovered 91% of the target compounds. A total of 192 samples can be analyzed within 1 day (22 h). The method can measure the endogenous estrogen sulfates in urine from both gravid and nongravid subjects.

Chromatography, High Pressure Liquid↗

Liquid-liquid extraction in the 96-well plate format with SRM LC/MS quantitative determination of methotrexate and its major metabolite in human plasma.

A method involving the semirobotic liquid-liquid extraction (LLE) in deep-well 96-well plates was developed for the quantitation of the anti-cancer/antiinflammatory drug methotrexate (MTX) and its major metabolite, 7-hydroxymethotrexate (7OH-MTX) in human plasma. The extraction time for the sample preparation was relatively short with four 96-well plates (384 samples) prepared in approximately 90 min by one person. The sample extracts were each analyzed within 1.2 min using a positive ion turbo-ionspray selected reaction monitoring liquid chromatography/mass spectrometric (SRM LC/MS) method in which 768 samples were easily analyzed within 22 h (maximum of 820 samples in 24 h). Deuterated internal standards, MTX-d3 and 7OH-MTX-d3, were used. The calibration curves for MTX and 7OH-MTX were linear (R2 > 0.997) and ranged from 0.5 to 250 and 0.75 to 100 ng/mL, respectively. The limit of quantitation (LOQ) for MTX and 7OH-MTX was 0.5 and 0.75 ng/mL, respectively; persistent carryover from the autosampler limited the LOQ achievable. The limit of detection (LOD) was 0.05 ng/mL for MTX and 0.1 ng/mL for 7OH-MTX. The intra- and inter-assay precision and accuracy did not exceed 15% for both MTX and 7OH-MTX. The recoveries were 61% for MTX and 47% for 7OH-MTX. The method was validated and demonstrated to be robust with high precision and accuracy.

Chromatography, High Pressure Liquid↗

High-throughput bioanalytical LC/MS/MS determination of benzodiazepines in human urine: 1000 samples per 12 hours.

The analytical capabilities of liquid chromatography tandem mass spectrometry for sensitive and highly selective determination of target compounds in complex biological samples makes it well suited for high-throughput analysis. We report the fast separation of six benzodiazepines isolated from human urine via selected reaction monitoring liquid chromatography/mass spectrometry using short dwell times to accommodate fast-eluting chromatographic peaks. The analytes were extracted from human urine samples along with their deuterium-labeled internal standards by a simple liquid-liquid extraction in 96-well plates. Using four autosamplers coupled to one chromatographic column and one tandem mass spectrometer operated in the turbo ion spray mode with positive ion detection, 1152 samples (12 96-well plates) were analyzed in less than 12 h. Through an electronic switching box designed and constructed in-house, the autosamplers were synchronized with the mass spectrometer so that injections were made as soon as the mass spectrometer was ready to collect data. Each run required 30 s to complete with another 7-8 s for the data system to load the next data file to be collected. Chromatographic integrity and ion current response remained relatively constant for the duration of the analyses. The results show acceptable precision and accuracy and demonstrate the feasibility of using fast separations with tandem mass spectrometry for high-throughout analysis of biological samples containing multiple analytes.

Benzodiazepines↗

High-throughput sample preparation and analysis using 96-well membrane solid-phase extraction and liquid chromatography-tandem mass spectrometry for the determination of steroids in human urine.

A 96-well solid-phase extraction (SPE) system is used to rapidly prepare human urine samples for high-throughput quantitative analysis of two steroids, equilenin and progesterone, by liquid chromatography-tandem mass spectrometry using deuterated estrone as the internal standard. We define high-throughput here as analysis of 384 samples in a 24 h period. A total of 384 samples and standards were extracted by an individual in one day and subsequently analyzed within a 24 h period. The inter- and intratray accuracy and precision obtained over the course of these injections was within 8% coefficient of variation when analyzed by atmospheric pressure chemical ionization mass spectrometry using positive ion detection. A semiautomated sample processing workstation was used to add internal standard and then process 96 samples at a time. The recovery of the analytes from the SPE was approximately 85%. The accuracy and precision obtained was comparable to that ordinarily obtained using manual sample preparation techniques.

Autoanalysis↗