Aluminum to oxygen cross-polarization in alpha-Al2O3 (corundum).

Experimental results concerning the cross-polarization of two quadrupolar, I = 5/2 nuclei are presented. It is shown in particular that 27Al spins in alpha-Al2O3 (corundum) can be spin-locked, and magnetization transferred to the 17O spin system. Cross-polarization between pairs of quadrupolar nuclei can cause considerable signal-to-noise ratio gains over conventional one- (or two-) pulse excitation and should be of use in investigating a number of inorganic solids.

Aluminum↗

Temporal variability and correlation with geometric parameters in vasospastic angina: a quantitative angiographic study.

Long-term changes in vasocontractility were examined in 23 coronary segments from 20 patients with variant angina using computer-based quantitative coronary angiography and ergonovine provocation tests repeated at an interval of 42 +/- 14 months. Measurements of vasospasticity at the sites of fixed stenoses were compared with values predicted by an elementary geometric theory based on the assumption that the cross-sectional area of a vessel wall is constant regardless of its state of vasoconstriction. While all patients were symptomatic initially, only 11 remained symptomatic at follow-up. At the initial provocation test, the response was correctly predicted in four segments, was lower than expected in one, and was stronger in 18. At follow-up, only one of the four segments in which the response had been initially predicted correctly again showed the predicted response and the remaining three showed a response weaker than expected; the one segment which was initially hypocontractile remained hypocontractile at follow-up; and of the 18 segments which were initially hypercontractile, 12 exhibited hypercontractility again, four had the predicted value and the remaining two showed hypocontractility. In only one of 23 segments did the geometric theory predict the behaviour of vasospasticity at the site of fixed stenosis on both tests. Vasospastic responsiveness is a dynamic process demonstrating temporal variability and is not directly predicted by geometric theory.

Angina Pectoris, Variant↗

Randomized trial comparing two devices: the Palmaz-Schatz stent and the Strecker stent in bail-out situations.

UNLABELLED: To assess whether differences in design (geometry, flexibility) and material (electrostatic behavior) may influence the acute and late outcome following intracoronary stent implantation in the treatment of acute or threatened closure after prolonged balloon inflations, 50 patients were randomized to receive either a Palmaz-Schatz stent (n = 25) or a Strecker stent (n = 25). RESULTS: [table: see text] CONCLUSION: Both Palmaz-Schatz and Strecker stents are equally effective in restoring vessel patency in bail-out situations. The incidence of complications is high and similar for both stents if they were used after failed prolonged balloon inflations. Differences in design and material do not seem to influence the results.

Angioplasty, Balloon, Coronary↗

Digital geometric measurements in comparison to cinefilm analysis of coronary artery dimensions.

Six months follow-up post-PTCA angiograms from 31 patients were acquired digitally and on cinefilm and used for a comparison of geometric coronary measurements at the site of the previous dilatation. On 70 images of 34 coronary segments quantitative analysis was performed both on-line, using the Automated Coronary Analysis package of the Philips Digital Cardiac Imaging System (DCI, pixel matrix 512 x 512) and off-line, using the Cardiovascular Angiography Analysis System (CAAS). With the CAAS a cine-video conversion is performed and a 6.9 x 6.9 mm region of interest from the 18 x 24 mm cineframe is digitized into a 512 x 512 pixel matrix. In both systems the vascular contours are assessed by means of operator-independent edge detection algorithms. The angiographic catheter was used for calibration. Best agreement between DCI and CAAS was found for obstruction diameter and minimal luminal diameter, respectively (r = 0.82; y = 0.12 + 0.97x; SEE = 0.29). The reconstructed reference diameter related to a computed reference contour yields lower correlation (r = 0.76; y = 0.27 + 0.91x; SEE = 0.37). Worst results were obtained from the relative measure of percent diameter stenosis as well as from the derived parameter of plaque area. The on-line digital approach of geometric coronary assessments provides good agreement with cinefilm analysis when direct measurements of coronary dimensions are applied.

Algorithms↗

Experimental validation of geometric and densitometric coronary measurements on the new generation Cardiovascular Angiography Analysis System (CAAS II).

Computer-assisted contour detection and videodensitometric cross sectional area assessment of coronary artery obstructions on the CAAS II system were validated in vitro and in vivo by angiographic cinefilm recording and automated measurement of stenosis phantoms (luminal diameter 0.5, 0.7, 1.0, 1.4, 1.9 mm) which were first inserted in a plexiglass model and then serially implanted in swine coronary arteries. "Obstruction diameter" (OD) and "obstruction area" (OA) values obtained from 10 in vitro and 19 in vivo images at the site of the artificial stenoses were compared with the true phantom dimensions. The in vitro assessment of OD yielded an accuracy of 0.00 +/- 0.11 mm (correlation coefficient: r = 0.98, y = 0.18 + 0.82x, standard error of estimate: SEE = 0.08), whereas the in vivo measurement of OD gave an accuracy of -0.01 +/- 0.18 mm (r = 0.94, y = 0.22 + 0.82x, SEE = 0.15). The assessment of OA gave an accuracy of -0.08 +/- 0.21 mm2 in vitro (r = 0.97, y = 0.08 + 0.99x, SEE = 0.22) and -0.22 +/- 0.32 mm2 in vivo (r = 0.95, y = 0.21 + 1.01x, SEE = 0.33). The mean reproducibility was +/- 0.09 mm for geometric measurements and +/- 0.21 mm2 for videodensitometric assessments, respectively. Thus, due to inherent limitations of the imaging chain, the reliability of geometric coronary measurements is still far superior to videodensitometric assessments of vessel cross sectional areas.

Absorptiometry, Photon↗

Quantitative angiography during coronary angioplasty with a single angiographic view: a comparison of automated edge detection and videodensitometric techniques.

Little information is available on the reliability of coronary luminal measurements obtained from quantitative analysis of a single angiographic view, an approach that is central to the practical use of on-line quantitative angiography. In the present study we investigated the contribution of two different techniques of quantitative angiography, edge detection (ED) and videodensitometry (VD), to the application of this concept during coronary angioplasty. Forty-six balloon angioplasty procedures were included in this study, all of them performed in a stenosis located in the mid right coronary segment. This coronary location was chosen to optimize data collection on luminal morphology and to minimize the number of factors that may adversely affect quantitative analysis with both techniques. In all cases two orthogonal angiographic projections were obtained before, after balloon dilatation, and at follow-up. Correlation coefficients and differences between orthogonal measurements obtained with each technique were used to evaluate the agreement between orthogonal readings at every stage of the procedure. The obtained correlation coefficients and mean differences (MD) between orthogonal measurements were as follows: before percutaneous transluminal coronary angiography (PTCA), 0.67 (MD 0.01 +/- 0.47 mm2) and 0.57 (MD 0.05 +/- 0.64 mm2) for ED and VD, respectively (Pitman's test for SD, p < 0.05); after balloon dilatation, 0.32 (MD -0.56 +/- 1.53 mm2) and 0.53 (MD -0.15 +/- 1.43 mm2) for ED and VD, respectively (paired t test for MD, p < 0.05); and at follow-up 0.79 (MD -0.15 +/- 0.97 mm2) and 0.73 (MD 0.17 +/- 1.16 mm2) for ED and VD, respectively (p = NS).(ABSTRACT TRUNCATED AT 250 WORDS)

Absorptiometry, Photon↗

Can the same edge-detection algorithm be applied to on-line and off-line analysis systems? Validation of a new cinefilm-based geometric coronary measurement software.

In the Cardiovascular Measurement System (CMS) the edge-detection algorithm, which was primarily designed for the Philips digital cardiac imaging system (DCI), is applied to cinefilms. Comparative validation of CMS and DCI was performed in vitro and in vivo with intracoronary insertion of stenosis phantoms in anesthetized pigs. The "obstruction diameter" (OD) was measured at the artificial stenoses visualized by angiography with calibration at the isocenter (ISO) and catheter calibration (CATH) and compared with the true phantom diameters. A clinical comparison of OD, reference diameter (RD), and percentage diameter stenosis (DS) was performed on 70 corresponding images from post-PTCA angiograms. In vitro, OD (CMS) yielded an accuracy of 0.18 +/- 0.14 mm with 100% (correlation coefficient: r = 0.97, y = 0.06 + 0.75x, standard error of estimate [SEE] = 0.09) and 0.19 +/- 0.15 mm with 50% contrast (r = 0.94, y = 0.02 + 0.81 x). OD (DCI) yielded an accuracy of 0.11 +/- 0.06 mm with 100% (r = 0.99, y = -0.03 + 0.91 x, SEE = 0.05) and 0.24 +/- 0.13 mm with 50% contrast (r = 0.94, y = 0.29 + 6.69 x, SEE = 0.12). In vivo, OD (CMS) yielded an accuracy of 0.18 +/- 0.23 mm with ISO (r = 0.89, y = 0.02 + 0.83 x, SEE = 0.22) and 0.26 +/- 0.24 mm with CATH (r = 0.89, y = 0.06 + 0.72 x, SEE = 0.19). OD (DCI) yielded an accuracy of 0.08 +/- 0.15 mm with ISO (r = 0.96, y = 0.08 + 0.86 x, SEE = 0.14) and 0.18 +/- 0.21 mm with CATH (r = 0.92, y = 0.09 + 0.76 x, SEE = 0.17). The clinical comparison showed reasonable agreement for OD only (r = 0.81, y = 0.26 + 0.81 x, SEE = 0.29). Transformation of an edge-detection algorithm from a digital to a cinefilm-based system can lead to impairment of measurement reliability.

Algorithms↗

In-vivo validation of on-line and off-line geometric coronary measurements using insertion of stenosis phantoms in porcine coronary arteries.

Geometric coronary artery measurements with the Phillips Digital Cardiac Imaging System (DCI) and the Cardiovascular Angiography Analysis System (CAAS) were validated using percutaneous insertion of radiolucent stenosis phantoms in swine coronary arteries. Angiographic visualization of the stenosis lumens (phi 0.5, 0.7, 1.0, 1.4, 1.9 mm) was simultaneously recorded on DCI and cinefilm. The acquisition systems were calibrated by either the diameter of the guiding catheter (catheter CAL) or the isocenter method (isocenter CAL). Minimal luminal diameters (MLD) obtained with CAAS and DCI on 20 corresponding cineframes were compared with the true phantom diameters (PD). The accuracy of MLD measurements with the CAAS using isocenter CAL was -0.07mm, the precision 0.21 mm (r = 0.91; y = 0.30 + 0.79x; SEE = 0.19), with catheter CAL the accuracy was 0.09 mm, the precision 0.23 mm (r = 0.89; y = 0.19 + 0.74x; SEE = 0.19). The accuracy of MLD measurements using the DCI with isocenter CAL was 0.08 mm, the precision 0.15 min (r = 0.96; y = 0.08 + 0.86x; SEE = 0.14), with catheter CAL the accuracy was 0.18 mm, the precision 0.21 mm (r = 0.92; y = 0.09 + 0.76x; SEE = 0.17). DCI underestimated PD with isocenter CAL (p less than 0.05) and with catheter CAL (p less than 0.001). MLD can be measured with high accuracy, both applying on-line digital as well as off-line cineangiographic analysis. The results of digital measurements demonstrate high reliability of the new digital software package.

Animals↗

Social-economic impact of head injury.

The socio-economic costs of traffic road accidents were analysed data epidemiological studies and compared with reported data. The costs are calculated as a function of accident type and vehicle involved, severity of head trauma, patients individual characteristics, type of care--intensive and emergency services, other hospital bed costs, including recovering and rehabilitation such as in-and out-patient services. Finally the costs of repairing materials (cars, walls, roads, etc.) are also estimated. The author concludes that the medical doctor must take part in compiling the statistics so as to be able to discuss the economics of injury and the social priorities.

Accidents, Traffic↗

Arachnoid cysts in children: a European co-operative study.

The data on arachnoid cysts in children (0-15 years) operated upon between 1980 and 1988 were analysed in a retrospective, co-operative study. The results from 285 patients indicate a predominance of these lesions in boys (64%) more than girls (36%) and a mean age of 6 years at onset of symptoms. Focal EEG patterns corresponding to the cyst's location were encountered in 32%. About 40% of all cysts were located along the midline, the sylvian fissure representing the predominant location. Open surgery, i.e. total excision or marsurpialization (together 43.3%), emerged as the first-choice surgical procedure. The type of surgery switched somewhat to shunting procedures in cases of lesions in deeper locations (22.8%). Morphological results on follow-up revealed a reduction of the size of the cyst in a significant majority (61%); in 18% the cyst had disappeared completely on CT scans. There was an obvious correlation between postoperative morphological findings and clinical outcome.

Adolescent↗

Edge detection versus densitometry in the quantitative assessment of stenosis phantoms: an in vivo comparison in porcine coronary arteries.

The aim of this study was the in vivo validation and comparison of the geometric and densitometric technique of a computer-assisted automatic quantitative angiographic system (CAAS system). In six Landrace Yorkshire pigs (45 to 55 kg), precision-drilled phantoms with a circular lumen of 0.5, 0.7, 1.0, 1.4, and 1.9 mm were percutaneously introduced into the left anterior descending or left circumflex coronary artery. Twenty-eight coronary angiograms obtained with the phantom in a wedged intracoronary position could be quantitatively analyzed. Minimal lumen diameter, minimal cross-sectional area, percent diameter stenosis, and cross-sectional area stenosis were automatically measured with both the geometric and densitometric technique and were compared with the known phantom dimensions. When minimal lumen diameter was measured using the geometric approach, a nonsignificant underestimation of the phantom size was observed, with a mean difference of -0.06 +/- 0.14 mm. The larger mean difference observed with videodensitometry (-0.11 +/- 0.20 mm) was the result of the failure of the technique to differentiate the low lumen videodensities of two phantoms of smaller size (0.5 and 0.7 mm) from a dense background. Percent cross-sectional area stenosis measured with the two techniques showed a good correlation with the corresponding phantom measurements (mean difference between percent cross-sectional area stenosis calculated from the quantitative angiographic measurements and the corresponding phantom dimensions was equal to 2 +/- 6% for both techniques, correlation coefficient = 0.93 with both techniques, SEE = 5% with the geometric technique and 6% with the densitometric approach).(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗