Search PubMed⌕ Search

Biomedical subjects

J Hüsing

Publications and source records attributed to J Hüsing.

23 records · Page 2Linked to original sources

Impact of resting and ischemic blood flow on infarct probability in ischemic preconditioning--a new approach to infarct size-blood flow data by logistic regression.

The linear regression analysis of infarct size (IS) v ischemic myocardial blood flow (MBF) does not account for the heterogeneity of MBF and infarcted tissue; moreover, it cannot assess a blood flow threshold for infarction (MBFT) accurately, as with ischemic preconditioning (IP) the close relationship between ischemic MBF and IS otherwise observed is lost. Finally, the impact of resting blood flow on myocardial infarction cannot be considered in such analysis. Therefore, in a retrospective data analysis of 32 enflurane-anaesthetized swine undergoing 90 min severe ischemia and 120 min reperfusion without (CON, n = 12) or with IP induced by either 3 (IP3, n = 8) or 10 min ischemia (IP10, n = 12) and 15 min reperfusion, a MBFT was assessed by logistic regression (LR) in individual tissue pieces. MBFT was arbitrarily defined as that ischemic MBF (microspheres) at which infarct probability was 0.2, derived from the ratio of infarcted (n = 141, TTC) to all tissue samples (n = 684). The duration of the preconditioning ischemia and MBF both at rest and during the sustained ischemia were significant predictors of infarct probability. Ischemic MBFT at an infarct probability of 0.2, was 0.089 +/- 0.023 ml/min/g in CON. MBFT was decreased to 0.051 +/- 0.03 ml/min/g with IP3 (P < 0.05 v CON) and further to 0.004 +/- 0.037 ml/min/g with IP10 (P < 0.05 v CON, IP3). Corresponding to the leftward shift of MBFT, the relationships between infarct probability and MBF were shifted in parallel by IP with no change in their slopes.

Animals↗

[Small premature infants do not tolerate axillary temperature measurement any better than rectal measurement. Study of the effect of axillary and rectal temperature measurement on vital parameters and cerebral hemodynamics and oxygenation].

BACKGROUND: Aim of this study was to assess, by use of monitoring parameters and near infrared spectroscopy (NIRS), whether premature infants tolerate axillary temperature measurement better than rectal. METHODS: Twenty-one infants were studied. Birth weight was 540-1680 g (median 840 g), weight at the time of investigation 470-1500 g (Median 920 g), gestational age 24-31 weeks (median 29 weeks), age at time of investigation 4-25 days (median 11 days). Four pairs of axillary/rectal temperatures were taken in every infant. Heart rate and oxygen saturation were monitored. Using NIRS cerebral oxygenated and deoxygenated hemoglobin were measured and total cerebral hemoglobin and the cerebral oxygenation index were calculated. RESULTS: Mean heart rate increased slightly but significantly from baseline during axillary and rectal temperature measurement (axillary: +6/min (+/- 7); p < 0.0001; rectal: +4/min (+/- 6); p < 0.0001). Peak increase in heart rate was significantly higher during axillary than during rectal temperature measurement (axillary: +18/min (+/- 10); rectal: +14/min (+/- 8); axillary versus rectal: p = 0.02). There was no difference in the number of measurements during which oxygen saturation dropped intermittently below 88% (rectal: 21% of measurements; axillary: 20% of measurements). NIRS parameters were not significantly different between axillary and rectal measurements: cerebral oxygenated hemoglobin and the oxygenation index showed a decrease in cerebral oxygenation during both, axillary and rectal measurement. CONCLUSIONS: Axillary temperature measurement is not better tolerated than rectal in premature infants.

Axilla↗

[Comparison of effects of endotracheal suction and surfactant administration on hemodynamics and oxygenation of premature infants--a near infrared spectroscopy study].

BACKGROUND: Aim of this study was to assess whether the decrease in heart rate and oxygen saturation occurring acutely after bolus administration of surfactant is different from the effect of endotracheal suctioning and whether there are effects on cerebral haemodynamics and oxygenation. METHODS: Twelve premature infants, birth weight 720-1560 g (Median 935 g), gestational age 25-30 weeks (Median 28 weeks), were investigated during surfactant administration (Curosurf) as a single bolus and a preceding endotracheal suctioning procedure. Using near infrared spectroscopy changes in cerebral blood volume and cerebral oxygenation index were assessed. Heart rate, arterial oxygen saturation, PCO2, and arterial blood pressure were registered continuously. Data were compared at 30, 60 and 120 seconds after the beginning of suctioning and surfactant administration. RESULTS: Endotracheal suctioning and surfactant administration induced a similar decrease in heart rate (-29/min, SD 25, p < 0.01 and -30/min, SD 23, p < 0.001) during the first 30 seconds and in oxygen saturation at the 30 seconds datapoint (-3%, SD 2, p < 0.01 and -3%, SD 6, p < 0.05). The decrease in oxygen saturation persisted at 60 seconds after the start of suctioning (-4%, SD 5, p < 0.05). In contrast, oxygen saturation was no longer different from baseline levels 60 seconds after surfactant administration (+1%, SD 6, p = 0.5). After suctioning, cerebral oxygenation index had decreased significantly from baseline levels at 30, 60, and 120 seconds. In contrast, after surfactant administration, no significant difference from baseline was noted at 30 and 60 seconds and a significant increase occurred at 120 seconds. Mean arterial blood pressure, PCO2, and cerebral blood volume did not change significantly during endotracheal suctioning and during surfactant administration. CONCLUSIONS: Acute decreases in heart rate and oxygen saturation during bolus administration of surfactant are equal to effects occurring during endotracheal suctioning. However, the decrease in oxygen saturation is shorter and more importantly, no decrease in cerebral oxygenation occurs.

Biological Products↗

Health care providers on the World Wide Web: quality of presentations of surgical departments in Germany.

It is becoming increasingly common for health care providers to present information on the World Wide Web (WWW). Patients, as well as health care professionals, do not really know what they can expect today. Many quality criteria are proposed for the assessment of medical Internet sites focusing mainly on structure and content management. The objective of this study was to assess the quality of presentations by health care providers on the WWW and to detect strengths and weaknesses with regard to potential target groups, patients, colleagues, and students. A sample of 171 presentations was randomly selected in March 2000 from a collection of 469 surgical departments in Germany. Medical doctors undergoing a full-time training in medical informatics rated the presentations. A previously evaluated questionnaire was used to assess the presentations with regard to 12 criteria about content and technical features. For each criterion the categories 'very good', 'sufficient', and 'insufficient' could be used. Twenty medical doctors assessed 168 presentations with one to seven valuations per presentation. Three presentations could not be accessed at the time of evaluation. Sixty-eight per cent of the median values of each criterion were rated as insufficient. The only criteria rated sufficient or better in at least 50% were: employees/map, survey of offered medical services, navigation, and layout. University hospitals and heart centres achieved significantly better results than regional hospitals. In conclusion, the quality of provider information on the W WW is unsatisfactory. Most surgical departments do not provide information that could help patients to choose their physicians. The criteria set developed here could be a useful tool for a target-group-oriented self-assessment of provider presentations on the World Wide Web.

Attitude of Health Personnel↗