Search PubMed⌕ Search

Biomedical subjects

J H Lief

Publications and source records attributed to J H Lief.

25 records · Page 2Linked to original sources

Potential role of various dosimetric quality indicators in prostate brachytherapy.

PURPOSE: Postoperative CT-based dosimetric analysis provides detailed information regarding the coverage and uniformity of an implant, but the assessment of implant quality remains an unanswered and controversial issue. There is no disagreement that a good implant should cover the target volume with an adequate dose, but there is no consensus as to what represents an adequate dose. MATERIALS AND METHODS: The American Brachytherapy Society has recently proposed that prostate brachytherapy quality be measured in terms of the following parameters: D90, V100, and V150 where D90 is defined as the minimal dose covering 90% of the prostate volume and V100 and V150 are defined as the percent volume of the prostate receiving at least 100% or 150% of the prescribed minimal peripheral dose (mPD), respectively. We report detailed day 0 dosimetric evaluation for 60 consecutive prostate brachytherapy patients implanted via a standard transperineal ultrasound guided approach in terms of D90, D100, V90, V100, and V150 and also the maximal and average rectal and urethral dose. RESULTS: Dosimetric evaluation resulted in a V100 greater than 80% of the prostate volume and a D90 greater than 90% of the mPD in the entire patient population. There was a statistically significant difference between the quality scores of 125I implants and 103Pd implants with the 125I mean V100 and D90 at 95.3% volume and 109.9% mPD, respectively, vs. 103Pd at 91.8% volume and 103.7% mPD. Likewise, the rectal and urethral doses as a fraction of mPD were significantly lower in 103Pd than in 125I implants. This occurred despite the fact that palladium implants were typically preplanned with significantly better coverage and hotter V150 than iodine implants. We consider V150 to be an important parameter for determining dose homogeneity although the clinical utility of dose homogeneity remains unknown. The mean V150 was 45.6 +/- 9.6% volume. There was no additional dosimetric utility from a determination of V90 while D100 was found to be overly sensitive to steep dose gradients at the periphery of the prostate. CONCLUSIONS: This report represents the first detailed postimplant day 0 dosimetric evaluation comparing ABS recommended quality parameters used to evaluate prostate brachytherapy. At the present time, no long-term clinical outcomes are available because of short follow-up. As PSA based follow-up data becomes available, however, this report may help define what represents an adequate implant.

Brachytherapy↗

Rectal dosimetric analysis following prostate brachytherapy.

PURPOSE: To retrospectively assess the rectal tolerance dose in transperineal ultrasound-guided prostate brachytherapy using easily measured point doses. METHODS AND MATERIALS: Forty-five consecutive patients who underwent prostate seed implantation from January 1996 to October 1996, using either 125I or 103Pd as monotherapy or as a boost following 45 Gy of external beam radiotherapy (XRT), were evaluated. For monotherapy using 125I, the minimal peripheral dose (mPD) was 160 Gy, utilizing dosimetry parameters which are equivalent to 144 Gy under the American Association of Physicists in Medicine Task Group 43 (AAPM TG43) recommendations. Computed tomography (CT)-based dosimetry was performed within 9 days of the implant, with a urinary catheter in place for identification of the urethra, and a rectal obturator positioned prior to the CT scan for identification of the anterior rectal mucosa. Dosimetric parameters relevant to this study were the average, maximal and minimal anterior rectal mucosal dose, and the surface area and length of the anterior rectal mucosa irradiated to 50%, 75%, 90%, 100%, and 120% of the prescribed dose. Rectal complications were determined by patient reporting during office visits and telephone follow-up. Follow-up ranged from 19 to 28 months (median 23). RESULTS: Among the four cohorts, the average anterior rectal mucosal dose as a percent of the prescribed mPD was 82.5% +/- 14.1% (standard deviation, SD), and the average maximum was 120% +/- 35%. The length of the rectum receiving a given dose was found to be correlated with the rectal surface area receiving that dose (r2 = 0.82 - 0.93 over the dose range 0.5-1.2 mPD). Rectal complications occurred in only four patients, and consisted of mild, self-limited proctitis. Three of the four were in the top quartile of average and maximal rectal dose and length of rectum receiving > or = 100% of mPD, while the fourth was in the bottom quartile of these parameters. In terms of surface area, all four patients were in the upper half of the study group, with > or = 90 mm2 at dose levels > or = 100% of mPD. CONCLUSION: Our results indicate that in an implant program which maintains the anterior rectal mucosa point dose averages to about 85% of the prescribed dose (regardless of the choice of isotope or the treatment approach), the average maximum to 120% of mPD, and the length of the anterior rectal mucosa receiving 100% and 120% of the prescribed dose at approximately 10 mm and 5 mm, respectively, the incidence of mild self-limited proctitis will be in the range of approximately 9%, without incidence of rectal ulceration and/or fistula formation.

Brachytherapy↗

Efficacy of sildenafil citrate in prostate brachytherapy patients with erectile dysfunction.

OBJECTIVES: To ascertain the efficacy of sildenafil citrate (Viagra) in patients with erectile dysfunction (ED) either before or after prostate brachytherapy by an open-label, nonrandomized study. METHODS: Sixty-two patients who underwent prostate brachytherapy between March 1995 and July 1998, had ED either before or after brachytherapy, and were interested in treatment with sildenafil comprised the patient population. Clinical and treatment parameters evaluated for medication efficacy included patient age at brachytherapy and at medication administration, hypertension, diabetes, smoking history, onset of ED, potency status before implant, frequency of intercourse before brachytherapy (if potent), use of neoadjuvant hormonal manipulation, use of moderate dose external beam radiation therapy before implantation, choice of isotope, V100 (the percentage of the prostate volume receiving at least 100% of the prescribed minimal peripheral dose), and sildenafil dose. RESULTS: Fifty (80.6%) of 62 patients responded favorably to sildenafil. None of the treatment parameters predicted medication failure, and among the clinical parameters, only diabetes predicted failure (3 of 5) and only with borderline statistical validity (P = 0.046). CONCLUSIONS: Our results suggest brachytherapy-induced impotence is as amenable to sildenafil treatment as ED from other causes. In addition, our 80.6% success rate is comparable to reported results for patients who underwent bilateral nerve-sparing radical prostatectomy and significantly better than patients who underwent unilateral nerve-sparing or non-nerve-sparing approaches.

Adenocarcinoma↗

Rate of phenotypic assortment in Tetrahymena thermophila.

During vegetative, asexual reproduction in heterozygous Tetrahymena thermophila, the macronucleus divides amitotically to produce clonal lineages that express either one or the other allele but not both. Because such phenotypic assortment has been described for every locus studied, its mechanism has important implications concerning the development and structure of the macronucleus. The primary tools to study assortment are Rf, the rate at which subclones come to express a single allele stably, and the output ratio, the ratio of assortee classes. Because Rf is related to the number of assorting units, a constant Rf for all loci suggests that all genes are maintained at the same copy number. Output ratios reflect the input ratio of assorting units, with a 1:1 output ratio implying equal numbers of alleles at the end of macronuclear development. Because different outcomes would suggest a different macronuclear structure, it is crucial that these parameters be accurately measured. Although published Rf values are similar for all loci measured, there has been no commonly accepted form of presentation and analysis. Here we examine the experimental determination of Rf. First, we use computer simulation to describe how the variability inherent in the assortment process affects experimental determination of Rf. Second, we describe a simple method of plotting assortment data that permits the uniform calculation of Rf, and we describe how to measure Rf accurately in instances when it is possible to score only the recessive allele. Using this method to produce truly comparable Rfs for all published data, we find that most, if not all, loci assort at Rfs consistent with approximately 45 assorting units, as has been asserted.

Animals↗

Radioactive seed embolization to the lung following prostate brachytherapy.

Over the past decade, prostate brachytherapy has been increasingly utilized as definitive management for early stage carcinoma of the prostate gland. One risk of the procedure is pulmonary seed embolization. In this article we report the incidence and timing of seed migration. Pulmonary embolization of radioactive seeds occurs in approximately 20% of patients undergoing prostate brachytherapy. To date, no acute or delayed detrimental effects have been reported which are attributable to the pulmonary embolization of the seeds; nevertheless, it is imperative that patients and health care providers be cognizant of this possible event.

Aged↗

Perineural invasion is not predictive of biochemical outcome following prostate brachytherapy.

PURPOSE: The purpose of this article is to evaluate whether the presence of perineural invasion (PNI) in the biopsy specimen is predictive of 5-year biochemical disease-free outcome after prostate brachytherapy. MATERIALS AND METHODS: Four hundred twenty-five patients underwent transperineal ultrasound-guided prostate brachytherapy using either 103Pd or 125I for clinical T1b/T3a NXMO (1997 American Joint Committee on Cancer) adenocarcinoma of the prostate gland from April 1995 to October 1999. No patient was lost to follow-up, and no patient underwent pathological lymph node staging. Two hundred twenty-one patients were implanted with 103Pd, and 204 patients were implanted with 125I. Of this cohort, 190 patients were implanted without supplemental beam radiation, and 235 received moderate-dose external-beam radiation therapy followed by a prostate brachytherapy boost. One hundred sixty-three patients received hormonal manipulation in conjunction with the brachytherapy implant (86 of these patients received moderate-dose external-beam radiation therapy before brachytherapy), and 262 patients were hormone naïve. Perineural invasion, defined as carcinoma tracking along or around a nerve within the perineural space, was identified in 105 patients (24.7% of the population). The median patient age was 68 years (range, 48-81 years). The mean follow-up was 37.1 +/- 15.2 months, and the median follow-up was 35.4 months (range, 6-74 months). Follow-up was calculated from the date of implantation. Biochemical disease-free survival was defined by the American Society of Therapeutic Radiation and Oncology (ASTRO) consensus definition. RESULTS: When Kaplan-Meier survival analysis was performed, the presence of PNI did not predict failure. When PNI was entered into a Cox regression analysis with evaluated clinical predictors of failure (age, clinical T stage, pretreatment prostate-specific antigen level, and Gleason score) or treatment parameters (use of neoadjuvant hormonal therapy, supplemental external-beam radiation therapy, and choice of isotope), PNI did not add to the predictive strength of these variables. The median disease-free prostate-specific antigen level was 0.1 ng/mL for the entire cohort. CONCLUSIONS: Our results indicate that actuarial 5-year biochemical outcomes with a prostate brachytherapy approach that utilizes generous periprostatic margins is not dependent on the presence of PNI. In addition, PNI should not be used as an independent prognosticator in determining the need for combined-modality therapy in patients undergoing prostate brachytherapy.

Adenocarcinoma↗