Search PubMed⌕ Search

Biomedical subjects

J H Kinney

Publications and source records attributed to J H Kinney.

At least 37 records · Page 2Linked to original sources

The importance of intrafibrillar mineralization of collagen on the mechanical properties of dentin.

It is widely held that the hardness and modulus of dentin increase in proportion to the mineral concentration. To test this belief, we measured hardness and modulus of normal dentin and an altered form of dentin without gap-zone mineralization in wet and dry conditions by AFM nanoindentation to determine if the modulus and hardness scale linearly with mineral concentration. Mineral concentrations in the mid-coronal location of the normal and altered dentins were 44.4 vol% and 30.9 vol%, respectively. Surrounding the pulp of the altered dentin was a region of higher mineralization, 40.5 vol%. The indentation modulus of normal dentin was 23.9 (SD = 1.1) GPa dry and 20.0 (SD = 1.0) GPa wet. In mid-coronal regions of the altered dentin, the indentation modulus was 13.8 (SD = 2.0) GPa dry and 5.7 (SD = 1.4) GPa wet. In the more mineralized regions of the altered dentin, the modulus was 20.4 (SD = 1.8) GPa dry and 5.3 (SD = 0.8) GPa wet; the properties of the altered wet dentin did not correlate with mineral concentration. The results of this study raise doubt as to whether mineral concentration alone is a sufficient endpoint for assessing the success or failure of remineralization approaches in restorative dentistry.

Adolescent↗

The mechanical properties of human dentin: a critical review and re-evaluation of the dental literature.

The past 50 years of research on the mechanical properties of human dentin are reviewed. Since the body of work in this field is highly inconsistent, it was often necessary to re-analyze prior studies, when possible, and to re-assess them within the framework of composite mechanics and dentin structure. A critical re-evaluation of the literature indicates that the magnitudes of the elastic constants of dentin must be revised considerably upward. The Young's and shear moduli lie between 20-25 GPa and 7-10 GPa, respectively. Viscoelastic behavior (time-dependent stress relaxation) measurably reduces these values at strain rates of physiological relevance; the reduced modulus (infinite relaxation time) is about 12 GPa. Furthermore, it appears as if the elastic properties are anisotropic (not the same in all directions); sonic methods detect hexagonal anisotropy, although its magnitude appears to be small. Strength data are re-interpreted within the framework of the Weibull distribution function. The large coefficients of variation cited in all strength studies can then be understood in terms of a distribution of flaws within the dentin specimens. The apparent size-effect in the tensile and shear strength data has its origins in this flaw distribution, and can be quantified by the Weibull analysis. Finally, the relatively few fracture mechanics and fatigue studies are discussed. Dentin has a fatigue limit. For stresses smaller than the normal stresses of mastication, approximately 30 MPa, a flaw-free dentin specimen apparently will not fail. However, a more conservative approach based on fatigue crack growth rates indicates that if there is a pre-existing flaw of sufficient size (approximately 0.3-1.0 mm), it can grow to catastrophic proportion with cyclic loading at stresses below 30 MPa.

Biomechanical Phenomena↗

Collagen orientation and crystallite size in human dentin: a small angle X-ray scattering study.

The mechanical properties of dentin are largely determined by the intertubular dentin matrix, which is a complex composite of type I collagen fibers and a carbonate-rich apatite mineral phase. We performed a small angle X-ray scattering (SAXS) study on fully mineralized human dentin to quantify this fiber/mineral composite architecture from the nanoscopic through continuum length scales. The SAXS results were consistent with nucleation and growth of the apatite phase within periodic gaps in the collagen fibers. These mineralized fibers were perpendicular to the dentinal tubules and parallel with the mineralization growth front. Within the plane of the mineralization front, the mineralized collagen fibers were isotropic near the pulp, but became mildly anisotropic in the mid-dentin. Analysis of the data also indicated that near the pulp the mineral crystallites were approximately needle-like, and progressed to a more plate-like shape near the dentino-enamel junction. The thickness of these crystallites, approximately 5 nm, did not vary significantly with position in the tooth. These results were considered within the context of dentinogenesis and maturation.

Collagen Type I↗

Local mechanical and optical properties of normal and transparent root dentin.

The mechanical and optical properties of healthy and transparent root dentin are compared using atomic force microscopy (AFM), micro-Raman and emission spectroscopies and fluorescence microscopy. The elastic modulus and hardness of intertubular and peritubular transparent and healthy dentin did not differ appreciably. The tubule filling material in the transparent zone, however, exhibited values between peritubular and intertubular dentin. Raman spectroscopy revealed a shift in the 1066 cm(-1) band to 1072 cm(-1) from normal to transparent intertubular dentin. The material filling the tubule lumen in transparent dentin showed an increase in frequency of the band near 1070 cm(-1) as well. The emission spectral characteristics under 351 nm photoexcitation indicate differences between normal and transparent intertubular dentin. A transition region of about 300 microm between normal and transparent dentin was identified. In this region the intertubular emission properties were the same as for normal dentin, but tubules were filled. The filling material had emission characteristics closer to the normal intertubular than to transparent intertubular dentin.

Journal Article↗

The spatial arrangement of tubules in human dentin.

We applied two-dimensional numerical methods to describe the spatial arrangement of tubules in human dentin. The methods considered were two-point correlation functions, entropy-like measures, and angular distributions between nearest neighbors. The correlation functions were based on Fourier transform methods. The latter two approaches were based on stochastic geometry, and involved developing the Delaunay tessellations of the tubule patterns and their dual Voronoi diagrams. We discovered that for analyzing the distribution of tubules the geometric methods of lattice tessellations were more sensitive to structural order of the tubules than were Fourier-based schemes. Analysis of the data indicated that dentinal tubules are highly ordered in normal dentin.

Journal Article↗

Intrafibrillar mineral may be absent in dentinogenesis imperfecta type II (DI-II).

High-resolution synchrotron radiation computed tomography (SRCT) and small-angle x-ray scattering (SAXS) were performed on normal and dentinogenesis imperfecta type II (DI-II) teeth. The SRCT showed that the mineral concentration was 33% lower on average in the DI-II dentin with respect to normal dentin. The SAXS spectra from normal dentin exhibited low-angle diffraction peaks at harmonics of 67.6 nm, consistent with nucleation and growth of the apatite phase within gaps in the collagen fibrils (intrafibrillar mineralization). In contrast, the low-angle peaks were almost non-existent in the DI-II dentin. Crystallite thickness was independent of location in both DI-II and normal dentin, although the crystallites were significantly thicker in DI-II dentin (6.8 nm [SD = 0.5] vs. 5.1 nm [SD = 0.6]). The shape factor of the crystallites, as determined by SAXS, showed a continuous progression in normal dentin from roughly one-dimensional (needle-like) near the pulp to two-dimensional (plate-like) near the dentin-enamel junction. The crystallites in DI-II dentin, on the other hand, remained needle-like throughout. The above observations are consistent with an absence of intrafibrillar mineral in DI-II dentin.

Adolescent↗

Tibial plateau fracture as a measure of early estrogen-dependent bone fragility in rats.

The goals of this study were to develop a protocol to induce a compressive fracture at the tibial plateau of the rat knee in vitro and to determine if the biomechanical parameters provided a sensitive assessment of the early skeletal changes induced by estrogen deficiency. Sixty-one rats underwent an ovariectomy (n = 36) or sham operation (n = 25) and were maintained for 50 days after the procedure. Just before death, the proximal tibia of each animal was scanned with high-resolution x-ray tomography. From the three-dimensional images, the mean trabecular bone volume, thickness, and separation and the number of trabeculae were calculated. The knees were then harvested and mounted into a servohydraulic materials testing system so that the distal femoral condyle could be forced into the proximal tibial plateau until fracture. The fracture load of the ovariectomized rats was 24% less than that of the rats that had the sham operation. Similarly, the structural stiffness of the ovariectomized knees was decreased by 22%. Both of these differences were statistically significant (p < 0.01) and were explained by differences in trabecular bone volume (r = 0.56, p < 0.0001 and r = 0.42, p < 0.005, respectively). The other measures of trabecular bone structure were correlated with the volume and did not improve the prediction by the biomechanical parameters. These data demonstrate that biomechanical testing of the tibial plateau in rats can quantify the structural consequences of estrogen deficiency at an early time point before they become apparent at other bone sites, such as the lumbar spine.

Animals↗

Three-dimensional morphometry of the L6 vertebra in the ovariectomized rat model of osteoporosis: biomechanical implications.

This article summarizes the results of a three-dimensional study of changes in the morphology of the L6 rat vertebra at 120 days after ovariectomy (OVX), with estrogen replacement therapy used as a positive control. Synchrotron radiation microtomography was used to quantify the structural parameters defining trabecular bone architecture, while finite-element methods were used to explore the relationships between these parameters and the compressive elastic behavior of the vertebrae. There was a 22% decrease in trabecular bone volume (TBV) and a 19% decline in mean trabecular thickness (Tb.Th) with OVX. This was accompanied by a 150% increase in trabecular connectivity, a result of the perforation of trabecular plates. Finite-element analysis of the trabecular bone removed from the cortical shell showed a 37% decline in the Young's modulus in compression after OVX with no appreciable change in the estrogen-treated group. The intact vertebrae (containing its trabecular bone) exhibited a 15% decrease in modulus with OVX, but this decline lacked statistical significance. OVX-induced changes in the trabecular architecture were different from those that have been observed in the proximal tibia. This difference was a consequence of the much more platelike structure of the trabecular bone in the vertebra.

Animals↗

Relationship between plain radiographic patterns and three- dimensional trabecular architecture in the human calcaneus.

The purpose of this study was to determine the relationship between three-dimensional (3D) trabecular structure and two-dimensional plain radiographic patterns. An in vitro cylinder of human calcaneal trabecular bone was three-dimensionally imaged by micro-CT using synchrotron radiation, at 33.4 micrometer resolution. The original 3D image was processed using 14 distinct sequences of morphologic operations, i.e., of dilations and erosions, to obtain a total of 15 3D models or images of calcaneal trabecular bone. These 15 models had distinct densities (volume fractions) and architectures. The 3D structure of each calcaneal model was assessed using mean intercept length (fabric), by averaging individual fabric measurements associated with each medial-lateral image slice, and determining the relative anisotropy, R(3D), of the structure. A summated pattern or plain radiograph was also computed from the 3D image data for each calcaneal model. Each summated pattern was then locally thresholded, and the resulting two-dimensional (2D) binary image analyzed using the same fabric analysis as used for the 3D data. The anisotropy of the 2D summated pattern was denoted by R(x-ray). The volume fractions of the 15 models ranged from 0.08 to 0.19 with a mean of 0. 14. The medial-lateral anisotropies, R(3D), ranged from 1.38 to 2.54 with a mean of 1.88. The anisotropy of the 2D summated patterns, R(x-ray), ranged from 1.35 to 2.18 with a mean of 1.71. The linear correlation of the 3D trabecular architecture, R(3D), with the radiographic trabecular architecture, R(x-ray), was 0.99 (p<0.0001). This study shows that the plain radiograph contains architectural information directly related to the underlying 3D structure. A well-controlled sequential reproducible plain radiograph may prove useful for monitoring changes in trabecular architecture in vivo and in identifying those individuals at increased risk of osteoporotic fracture.

Anisotropy↗

A micromechanics model of the elastic properties of human dentine.

A generalized, self-consistent model of cylindrical inclusions in a homogeneous and isotropic matrix phase was used to study the effects of tubule orientation on the elastic properties of dentine. Closed-form expressions for the five independent elastic constants of dentine were derived in terms of tubule concentration, and the Young's moduli and Poisson ratios of peri- and intertubular dentine. An atomic-force microscope indentation technique determined the Young's moduli of the peri- and intertubular dentine as approx. 30 and 15 GPa, respectively. Over the natural variation in tubule density found in dentine, there was only a slight variation in the axial and transverse shear moduli with position in the tooth, and there was no measurable effect of tubule orientation. It was concluded that tubule orientation has no appreciable effect on the elastic behaviour of normal dentine, and that the elastic properties of healthy dentine can be modelled as an isotropic continuum with a Young's modulus of approx. 16 GPa and a shear modulus of 6.2 GPa.

Dentin↗

Computational methods for ultrasonic bone assessment.

Ultrasound has been proposed as a means to noninvasively assess bone and, particularly, bone strength and fracture risk. Although there has been some success in this application, there is still much that is unknown regarding the propagation of ultrasound through bone. Because strength and fracture risk are a function of both bone mineral density and architectural structure, this study was carried out to examine how architecture and density interact in ultrasound propagation. Due to the difficulties inherent in obtaining fresh bone specimens and associated architectural and density features, simulation methods were used to explore the interactions of ultrasound with bone. A sample of calcaneal trabecular bone was scanned with micro-CT and subjected to morphological image processing (erosions and dilations) operations to obtain a total of 15 three-dimensional (3-D) data sets. Fifteen two-dimensional (2-D) slices obtained from the 3-D data sets were then analyzed to evaluate their respective architectures and densities. The architecture was characterized through the fabric feature, and the density was represented in terms of the bone volume fraction. Computer simulations of ultrasonic propagation through each of the 15 2-D bone slices were carried out, and the ultrasonic velocity and mean frequency of the received waveforms were evaluated. Results demonstrate that ultrasound propagation is affected by both density and architecture, although there was not a simple linear correlation between the relative degree of structural anisotropy with the ultrasound measurements. This study elucidates further aspects of propagation of ultrasound through bone, and demonstrates as well as the power of computational methods for ultrasound research in general and tissue and bone characterization in particular.

Biophysical Phenomena↗

Early estrogen replacement therapy reverses the rapid loss of trabecular bone volume and prevents further deterioration of connectivity in the rat.

To evaluate the ability of estrogen replacement therapy (ERT) to prevent changes in trabecular bone volume (BV/TV) and connectivity beginning either at ovariectomy (OVX) or 5-13 days after OVX in adult female rats, the right proximal tibial was examined by three-dimensional X-ray tomographic microscopy (XTM) in vivo. Animals had XTM scans of the right tibia and then were randomized into six groups (n = 9). Groups 2-6 had bilateral (OVX), while group 1 was sham-ovariectomized (OVXd) on day 0. Animals were treated with vehicle (groups 1 and 2) or 17beta-estradiol therapy (ERT) at 10 microg/kg three times per week starting at days 0, 5, 8, and 13 post-OVX (groups 3, 4, 5, and 6), until day 50 when they were rescanned by XTM and sacrificed. Trabecular bone structural variables were calculated from XTM data (BV/TVx and beta1/BV/TVx) and standard histomorphometry. Trabecular bone volume (BV/TVx) and the trabecular connections per cubic millimeter of trabecular bone (beta1/BV/TVx) were maintained in both sham-OVXd animals and OVX animals given ERT from the time of OVX. However, OVX + vehicle-treated animals lost 54% BV/TVx and 46% beta1/BV/TVx (p < 0. 01 from day 0). BV/TVx and beta1/BV/TVx decreased rapidly post-OVX to -22% and -25% at day 13 (p < 0.01 from day 0). ERT initiated at day 5, 8, and 13 post-OVX restored BV/TVx to baseline values at day 50 by modestly increasing trabecular plate thickness; however, beta1/BV/TVx was reduced in all OVX groups when compared with their baseline values. ERT also caused a significant reduction in bone turnover compared with OVX + vehicle; however, resorption was suppressed more than formation. These results demonstrate that ERT can restore the lost trabecular bone, but not trabecular connectivity, that occurs soon after OVX by allowing bone formation to continue in previously activated bone remodeling units while suppressing the production of new remodeling units. This may be the mechanism by which prompt intervention with estrogen and other antiresorptive agents can restore bone mass that has been lost from the increase in remodeling space, and thereby reduce the risk of osteoporotic fractures in postmenopausal women.

Animals↗

Effect of citric acid concentration on dentin demineralization, dehydration, and rehydration: atomic force microscopy study.

Most current dentin bonding procedures use acid etchants to partially demineralize the dentin structure and provide pathways for resin infiltration. This study determined the recession rates of peritubular dentin and intertubular dentin as a function of pH during demineralization in citric acid solutions (0.0005-2.5M) and the effects of dehydration and rehydration on the partially demineralized dentin. Polished dentin disks were prepared with an internal reference layer and were studied at specific intervals for citric acid etching between pH 1 and 3.4 in an atomic force microscope. Peritubular dentin etched rapidly and linearly with time until it could no longer be measured. The intertubular surface began etching at nearly the same rate, but then recession slowed for all concentrations and stabilized after recession of less than 1 microm for all but the pH 1 solution. The decrease in recession was attributed to the limitation of contraction of the demineralized collagen scaffold as long as it remained hydrated. Dehydration following etching resulted in significant collapse of the surface, changes in roughness, and a slight decrease in tubule diameter for samples etched for 30 min. Measurements could not be made of the collapse for low pH samples, because shrinkage stresses disrupted the integrity of the reference layer. On rehydration, the dehydrated surfaces underwent an expansion up to the level seen after etching and tubule diameters returned to the etched values. These results indicate that the collapse of demineralized matrix is almost totally recoverable on rehydration.

Citric Acid↗

Viscoelastic properties of demineralized human dentin measured in water with atomic force microscope (AFM)-based indentation.

Using an atomic force microscope (AFM) with an attachment specifically designed for indentation, we measured the mechanical properties of demineralized human dentin under three conditions: in water, in air after desiccation, and in water after rehydration. The static elastic modulus (E(h)r = 134 kPa) and viscoelastic responses (tau(epsilon) = 5.1 s and tau(sigma) = 6.6 s) of the hydrated, demineralized collagen scaffolding were determined from the standard linear solid model of viscoelasticity. No significant variation of these properties was observed with location. On desiccation, the samples showed considerably larger elastic moduli (2 GPa), and a hardness value of 0.2 GPa was measured. Upon rehydration the elastic modulus decreased but did not fully recover to the value prior to dehydration (381 kPa).

Analysis of Variance↗

Finite-element modeling of trabecular bone: comparison with mechanical testing and determination of tissue modulus.

We combined three techniques--mechanical testing, three-dimensional imaging, and finite-element modeling--to distinguish between the contributions of architecture and tissue modulus to mechanical function in human trabecular bone. The objectives of this study were 2-fold. The first was to assess the accuracy of micromechanical modeling of trabecular bone using high-contrast x-ray images of the trabecular architecture. The second was to combine finite-element calculations with mechanical testing to infer an average tissue modulus for the specimen. Specimens from five human L1 vertebrae were mechanically tested along the three anatomic axes. The specimens were then imaged by synchrotron x-ray tomography, and the elastic moduli of each specimen were calculated from the tomographic image by finite-element modeling. We found that 23-microm tomographic images resolved sufficient structural detail such that the calculated anisotropy in the elastic modulus was within the uncertainties of the experimental measurements in all cases. The tissue modulus of each specimen was then estimated by comparing the calculated mean stiffness of the specimen, averaged over the three anatomical directions, with the experimental measurement. The absolute values of the experimental elastic constants could be fitted, again within the uncertainties of the experimental measurements, by a single tissue modulus of 6.6 GPa, which was the average tissue modulus of the five specimens. These observations suggest that a combination of mechanical testing, three-dimensional imaging, and finite-element modeling might enable the physiological variations in tissue moduli to be determined as a function of age and gender.

Aged↗

Numerical errors and uncertainties in finite-element modeling of trabecular bone.

Although micromechanical finite-element models are being increasingly used to help interpret the results of bio-mechanical tests, there has not yet been a systematic study of the numerical errors and uncertainties that occur with these methods. In this work, finite-element models of human L1 vertebra have been used to analyze the sensitivity of the calculated elastic moduli to resolution, boundary conditions, and variations in the Poisson's ratio of the tissue material. Our results indicate that discretization of the bone architecture, inherent in the tomography process, leads to an underestimate in the calculated elastic moduli of about 20% at 20 microm resolution; these errors vary roughly linearly with the size of the image voxels. However, it turns out that there is a cancellation of errors between the softening introduced by the discretization of the bone architecture and the excess bending resistance of eight-node hexahedral finite elements. Our empirical finding is that eight-node cubic elements of the same size as the image voxels lead to the most accurate calculation for a given number of elements, with errors of less than 5% at 20 microm resolution. Comparisons with mechanical testing are also hindered by uncertainties in the grip conditions: our results show that these uncertainties are of comparable magnitude to the systematic differences in mechanical testing methods. Both discretization errors and uncertainties in grip conditions have a smaller effect on relative moduli, used when comparing between different specimens or different load directions, than on an absolute modulus. The effects of variations in the Poisson's ratio of the bone tissue were found to be negligible.

Bone and Bones↗

Acute changes in trabecular bone connectivity and osteoclast activity in the ovariectomized rat in vivo.

Estrogen deficiency results in a loss of trabecular bone mass and structure that leads to an increased incidence of osteoporotic fractures. The purpose of this study was to determine the time course for trabecular structure deterioration and changes in bone turnover just after ovariectomy in the rat. Six-month-old female virgin Sprague-Dawley rats had their right proximal tibia scanned by X-ray tomographic microscopy (XTM) at baseline (day 0). Animals were then randomized into two groups, and in each group 9 were sham-operated and 11 were ovariectomized and had repeat XTM scans on days 5, 13, 29, and 42 postovariectomy in group 1 and on days 8, 13, 33, and 50 postovariectomy in group 2. Urine was collected for deoxypyridinoline (DPD) cross-link measurements 24 h before each XTM scan and analyzed by ELISA. Trabecular bone structural variables and bone turnover endpoints were calculated from XTM data and standard histomorphometry. Trabecular connectivity decreased 27% by days 5 and 8 postovariectomy (p < 0.01) and continued to decrease up to day 50 postovariectomy (p < 0.01). The trabecular bone volume decreased 25% by 8 days postovariectomy (p < 0.01), and it continued to decrease through day 50. DPD cross-link excretion had increased 37% on day 13 (p < 0.01) and by over 100% of baseline by day 50 postovariectomy. Trabecular bone connectivity and volume deteriorate rapidly while DPD cross-link excretion increased more slowly in acute estrogen deficiency. These data suggest that if an agent is to preserve fully trabecular bone structure, it must be instituted very early in the estrogen-deficient state. They also suggest that a lag time exists before DPD excretion properly mirrors newly induced conditions of high bone turnover in this rat model.

Amino Acids↗