The masking-level difference in low-noise noise.

In experiment 1 NoSo and NoS pi thresholds for a 500-Hz pure tone were obtained in a low-fluctuation masking noise and a high-fluctuation masking noise for six normal-hearing listeners. The noise bandwidth was 10 Hz. In agreement with previous investigations, the NoSo thresholds were lower in low-fluctuation noise than in high-fluctuation noise. For three listeners, NoS pi thresholds were similar for the two types of noise, while for the other three listeners, Nos pi thresholds were higher for low-fluctuation noise than for high-fluctuation noise. In experiment 2, the masker was created by amplitude modulating a 500-Hz pure tone by a 0-10-Hz low-pass noise. The degree of masker fluctuation was controlled by adjusting the average modulation depth (100%, 63%, 40%, and 25%). The signal was a 10-Hz-wide noise centered on 500 Hz. Results were similar to those of experiment 1: for the NoSo conditions, signal detection improved with decreasing degree of fluctuation, and for NoS pi conditions, the results were subject dependent. For three listeners, NoS pi thresholds were again similar in the two types of noise, while for the other three listeners, NoS pi thresholds were again higher in low-fluctuation noise than in high-fluctuation noise. The results showed that a high degree of masker fluctuation sometimes facilitates NoS pi detection. It is possible that the binaural detection mechanism utilizes the relatively good signal-to-noise ratios that occur in the low power or "dip" regions of fluctuating masker waveforms.

Adult↗

Masker fluctuation and the masking-level difference.

Previous work suggests that, for some listeners, masker fluctuation may be advantageous for NoS pi detection. This study tested the hypothesis that the benefit of masker fluctuation to binaural analysis is based on the ability to take advantage of epochs of low masker energy in the fluctuating masker where the cues underlying binaural signal detection are more salient. The hypothesis was evaluated using the time-domain version of COSS analysis derived by Buus et al. [J. Acoust. Soc. Am. 99, 2288-2297 (1996)] which measures the perceptual weight applied by a listener within a relatively brief time window as a function of the masker level during the window. The results indicated a dependency of signal detection on short-term masker level in the NoS pi condition but not in the NoSo condition. This finding supports a new perspective indicating that binaural signal detection depends upon the envelope of a masker in a way that is fundamentally different from that typically associated with monaural detection.

Auditory Perception↗

Hemodynamic and hormonal changes during erythropoietin therapy in hemodialysis patients.

To better understand the mechanism of recombinant human erythropoietin (rhEPO)-induced increase in BP, hemodynamic parameters, body fluid volumes, and the hormones implicated in BP regulation were studied in 32 anemic hemodialysis patients before and after 3 to 4 mo of rhEPO therapy. Hemoglobin levels increased from 83 +/- 1.5 to 119 +/- 2.3 g/L (P < 0.01) after rhEPO therapy (25 to 43 U/kg) administered subcutaneously three times weekly. Mean 24-h systolic and diastolic ambulatory BP were significantly increased by 14 +/- 3 and 10 +/- 2 mmHg, respectively (P < 0.01 for both groups). Systemic vascular resistance consistently increased by 28 +/- 5% (P < 0.01), whereas cardiac output was decreased by 6 +/- 3% (P < 0.05). Red blood cell mass increased by 510 +/- 35 ml (P < 0.01), whereas plasma volume decreased by 420 +/- 66 ml (P < 0.01), which resulted in a nonsignificant increase in total blood volume. Extracellular fluid volume and exchangeable sodium were decreased by 873 +/- 255 ml (P < 0.01) and 125 mmol (P < 0.01), respectively. There was a positive correlation between the changes in exchangeable sodium and in systolic BP (r = 0.41, P < 0.05). Furthermore, a greater increase in 24-h systolic BP was observed in patients in whom exchangeable sodium increased or remained unchanged (n = 10) compared with patients (n = 22) with decreased exchangeable sodium (20 +/- 4 mmHg versus 8 +/- 2 mmHg, respectively, P < 0.01). Plasma catecholamines, plasma renin concentration, plasma atrial natriuretic peptide, and plasma endothelin-1 did not significantly change with rhEPO treatment, whereas plasma aldosterone increased significantly (P < 0.01). Although volume-independent mechanisms may contribute to rhEPO-induced BP increase, the results presented here suggest the importance of optimally reducing extracellular fluid volume to prevent, at least in part, the development of hypertension often observed with improved uremic anemia in these patients.

Adolescent↗

Plasma and blood vessel endothelin-1 concentrations in hypertensive uremic rats treated with erythropoietin.

The present study was designed to evaluate whether changes in plasma and blood vessel endothelin-1 (ET-1) concentrations may play a role in the enhanced blood pressure response to recombinant human erythropoietin (r-HuEPO) replacement therapy in uremia. Renal failure was induced by 5/6 nephrectomy (Nx). Uremic rats received either r-HuEPO (100 u s.c. three times a week) or the vehicle for 5 weeks. They were compared to control rats receiving the vehicle. Systolic blood pressure (tail cuff method), hematocrit, serum creatinine, plasma and tissue ET-1 were measured at the end of the protocol. Immunoreactive ET-1 (ir-ET-1) was determined by radioimmunoassay of acid-extracts from the plasma, thoracic aorta and mesenteric arterial bed. Creatinine increased about three fold in Nx animals. Blood pressure in control rats was 120+/-3 mmHg compared to 161 +/-6 mmHg in the Nx + vehicle group (p <0.01) and 199+/-9 mmHg in the Nx + r-HuEPO group (p <0.01 vs Nx + vehicle). Hematocrit in control rats was 41.3+/-0.4% vs 32.6+/-1.8% in the Nx + vehicle group (p <0.01) and 47.6+/-1.5% in the Nx + r-HuEPO group (p <0.01). Plasma ir-ET-1 levels were similar in the Nx + vehicle and Nx + r-HuEPO groups (7.9+/-1.0 and 7.8+/-0.8 pg/ml). In contrast, thoracic aorta ir-ET-1 content was significantly higher in the Nx + r-HuEPO group than in the Nx + vehicle group (20.3+/-2.9 vs 13.4+/-1.9 pg, p <0.05). Similar results were obtained in the mesenteric arterial bed. There were significant correlations between blood pressure and ir-ET-1 content in the thoracic aorta (r= 0.45, p<0.05) and in the mesenteric arterial bed (r= 0.41, p<0.05). Vascular ET-1 content but not plasma levels are increased in uremic rats treated with r-HuEPO suggesting an increase in blood vessel ET-1 production which may play a role in the pathogenesis of r-HuEPO-induced hypertension.

Animals↗

Plasma and peritoneal endothelin levels and blood pressure in CAPD patients with or without erythropoietin replacement therapy.

The aim of the study was to determine the ET-1 concentration in peritoneal dialysate fluid and to investigate the relationship between peritoneal and plasma ET-1 levels and blood pressure in stable continuous ambulatory peritoneal dialysis (CAPD) patients with and without human recombinant erythropoietin (r-HuEPO) replacement therapy. Twenty-seven stable CAPD patients were investigated. They completed their overnight exchange at the Dialysis Centre. Blood pressure was recorded and a blood sample was drawn. Biochemical parameters and ET-1 were measured in plasma and peritoneal dialysate fluid. Mean plasma ET-1 levels were increased by about four-fold in CAPD patients. ET-1 was detectable in peritoneal dialysate fluid and a significant correlation was observed between plasma and peritoneal ET-1 concentrations (r = 0.65, p < 0.01). The peritoneal clearance of ET-1 was lower than the creatinine clearance (1.69 +/- 0.08 ml/min vs. 3.96 +/- 0.15 ml/min, p < 0.01). There was also a significant correlation between the time (months) on dialysis and plasma (r = 0.68, p < 0.01) or peritoneal dialysate ET-1 levels (r = 0.46, p < 0.05). Mean blood pressure was higher in patients treated with r-HuEPO than in untreated patients (97 +/- 4 mmHg vs. 81 +/- 4 mmHg, p < 0.01). Plasma and peritoneal dialysate ET-1 concentrations were comparable in the two groups with or without r-HuEPO replacement therapy and plasma ET-1 values correlated significantly with mean blood pressure only in r-HuEPO-treated patients (r = 0.63, p < 0.05 vs. r = 0.10, N.S. in untreated patients). In conclusion, plasma ET-1 concentrations are elevated in CAPD patients and the levels appear to increase with time on dialysis. ET-1 is cleared by the peritoneal membrane but at a much lower rate than creatinine. Blood pressure is higher in CAPD patients or r-HuEPO replacement therapy and blood pressure correlates with plasma ET-1 levels in these patients.

Ascitic Fluid↗

Auditory development in complex tasks of comodulation masking release.

Experiments on listeners aged 5 years to adult were conducted to investigate the development of comodulation masking release (CMR) under conditions where auditory grouping could be affected either by the coherence of modulation pattern among noise bonds, or the temporal asynchrony among bands. The conditions examining CMR when two modulation patterns were present (each carried by a different set of noise bands) indicated a similar effect across all age groups. Here, CMR was substantial when the on-signal band (OSB) and six comodulated flanking bands (FBs) were presented, decreased when two bands having a second pattern of modulation were added, and then recovered partially when a further six bands that had the second modulation pattern were added. In conditions where there was a temporal asynchrony between the OSB and the FBs, the children typically showed smaller CMRs than the adults. In the case where the OSB preceded the FBs, adults typically showed CMR near zero when the temporal fringe was 50 ms or more. Children usually showed negative CMRs for such conditions. In the case where the FBs preceded the OSB, all age groups showed substantial CMRs, but the CMRs of adults were significantly larger than those of the children. The present results indicate that the effect of a second, independent modulation pattern on CMR is similar in children and adult listeners, but that CMR appears to be detrimentally affected more in children than in adults when there is a temporal asynchrony between the on-signal and flanking bands.

Adult↗

MLD in children: effects of signal and masker bandwidths.

The first aim of this study was to obtain a more detailed picture of the effect of masker bandwidth (20 Hz to 1000 Hz bandwidth) on the masking level difference (MLD) for a 500-Hz signal as a function of listener age. The results of the pure-tone signal experiment showed that the MLDs of older children differed from adults only for the narrowest masker bandwidth. In contrast, children younger than about 7 years of age tended to have smaller MLDs than adults at all but the widest masker bandwidth must be for MLDs of adult magnitude to be observed. One interpretation of this effect is that younger listeners require relatively great spectral dissimilarity (and, therefore perceptual dissimilarity) between the signal and masker in order to obtain MLDs of adult magnitude. The second aim of this study was to test this possibility by determining the MLD for noise signals in cases where the signal and masker bandwidths were the same. The results of this experiment showed that the MLDs of children were as large as those of adults when the signal/masker bandwidth was 320 Hz, but were smaller than those of adults when the signal/masker bandwidth was 20 Hz. This indicates that the factor limiting the MLD for narrowband noise in children is related more to the masker bandwidth than to the perceptual similarity between the signal and the masker.

Adult↗

The relation between gap detection, loudness, and loudness growth in noise-masked normal-hearing listeners.

Gap detection was measured for 50 and 1000-Hz-wide noise markers arithmetically centered on 1000 Hz. The markers were presented in a lowpass background noise having a high-frequency cutoff of 2000 Hz. The pressure spectrum level of the background noise was either 0 or 40 dB/Hz. Gap detection was determined at sensation levels (SLs) of 10, 15, 20, and 30 dB in the 0-dB/Hz background, and at SLs of 10, 15, and 20 dB in the 40-dB/Hz background. Because loudness increased more steeply in the higher level noise background, the markers in the 40-dB/Hz background were at higher loudness (and at a steeper portion of the loudness growth function) than markers in the 0-dB/Hz background, for markers matched in terms of SL. The main goal of the experiment was to determine whether gap detection would be relatively poor at steep portions of the loudness growth function due to the gap being confused with ongoing random dips. Such confusion might be particularly great when the noise bandwidth was narrow (and therefore characterized by prominent fluctuation) and the growth of loudness was steep. Gap detection was poorer for the 50-Hz-wide marker than for the 1000-Hz-wide marker. For a given marker bandwidth at a given SL, gap detection was similar whether the marker was presented in the 0-dB/Hz noise or the 40-dB/Hz noise. Supplementary conditions indicated that (1) gap detection results for 50-Hz-wide markers presented at equal SL's were also similar between a 0-dB/Hz noise background and a 55-dB/Hz noise background, and that (2) gap detection for 50- and 1000-Hz-wide markers was poorer in a 40-dB/Hz background than in a 0-dB/Hz background when markers were matched for loudness. The results generally indicated similar gap detection thresholds for markers presented at similar SLs across a relatively wide range of background noise levels. Gap detection was related more closely to the marker-to-noise ratio than to the loudness relation between markers or the steepness of loudness growth.

Auditory Threshold↗

Multiband detection of energy fluctuations.

this study sought to characterize the integration of synchronous energy fluctuations across relatively independent spectral regions. The detection of four classes of signal was examined where each class of signal was associated with a change in energy over time. The four signal types were: (1) multicomponent tonal complexes, with each component centered in a narrow band of noise; (2) intensity increments in multiple narrow bands of noise; (3) intensity decrements in multiple narrow bands of noise; and (4) temporal gaps in multiple narrow bands of noise. Each signal type was examined in a separate experiment, although stimulus characteristics such as presentation level and frequency location were held constant. Experiment 1 confirmed that the detection of multitonal complexes masked by narrow bands of noise is linearly related to the square root of N, where N is the number of signal components. Experiment 2 extended this to show that, when the signal was an increment in the level of a noise band carrier, threshold continued to be a linear function of the square root of N, although threshold was about 2 dB higher than for a comparable tonal signal. Experiment 3 indicated that the detection of a decrement in energy in one or more noise bands was relatively poorer in terms of absolute level changes than was the detection of an energy increment in the same stimulus. Examination of psychometric functions for decrement detection suggested that performance improved by less than the square root of N. Experiment 4 found that gap detection improved with increasing N but by a factor greater than the square root of N expected on statistical grounds. Examination of the underlying psychometric functions confirmed this effect. The results of these experiments suggest that, for energy increments, the auditory system integrates information from across the spectrum in a statistically independent manner, at least over the frequency range examined here. This does not appear to be the case for the detection of energy gaps or decrements.

Adult↗

Signal detection and pitch ranking in conditions of masking release.

Masked threshold levels for signal detection or pitch ranking (low, middle, or high) were determined in conditions where one of three possible signal frequencies could be presented on a given trial of a three-interval forced-choice task. Thresholds were determined under conditions investigating binaural masking release (the masking-level difference, or MLD) and monaural masking release in modulated noise. It was assumed that part of the masking release in modulated noise was due to a within-channel analysis of information in the masker dips, and that part of the masking release was due to across-frequency analysis of temporal envelope information (comodulation masking release, or CMR). In the MLD experiment, the masker was a low-pass noise with a frequency cutoff of 1000 Hz. In the modulated-noise experiment, a broadband noise was square-wave amplitude modulated at a rate of 25 Hz and then digitally low-passed filtered at 1000 Hz. The results indicated that when the frequency separation between frequency components was relatively wide, masking release for pitch ranking was similar to that for signal detection. However, as the frequency separation between components narrowed, masking release for pitch ranking decreased. The results are consistent with an interpretation that information regarding signal frequency is relatively coarse under the conditions of masking release examined here.

Adult↗

Increased immunoreactive endothelin-1 levels in blood vessels and glomeruli of rats with reduced renal mass.

Elevated plasma and urinary endothelin-1 (ET-1) levels have been reported in patients with renal failure as well as in remnant kidney models of chronic renal failure. We investigated whether these changes are related to increased ET-1 production in cardiovascular and renal tissues of rats with reduced renal mass. In uremic rats, systolic blood pressure rose in parallel with the progression of renal insufficiency. At week 6, changes in systolic blood pressure were positively correlated with serum creatinine levels (r = 0.728, p < 0.01). Plasma immunoreactive ET-1 (ir-ET-1) concentration was similar in uremic rats and sham-operated controls. In contrast, urinary ir-ET-1 excretion was significantly greater in uremic rats and was correlated with the elevation of serum creatinine and proteinuria (r = 0.795, and 0.922, p < 0.01, respectively). Compared to the controls, ir-ET-1 concentration in the thoracic aorta, preglomerular arteries and glomeruli were 1.4-, 3.5- and 6.7-fold higher, respectively, in uremic rats (p < 0.01) than in the controls. However, ir-ET-1 concentration in the mesenteric arterial bed and the left ventricle remained similar in the 2 groups, whereas it was significantly lower in the renal papilla of uremic rats (p < 0.01). Thus, ET-1 production is unchanged or slightly increased in extrarenal cardiovascular tissues of rats with reduced renal mass. In contrast, ET-1 production is significantly augmented in preglomerular arteries and glomeruli, but reduced in the papilla, suggesting that increased urinary ir-ET-1 excretion in uremic rats reflects ET-1 overproduction in the former renal tissues. Elevated ET-1 production in blood vessels and glomeruli may thus play a key role in the aggravation of hypertension and the progression of renal insufficiency in this rat remnant kidney model of chronic renal failure.

Animals↗

Uremia enhances the blood pressure response to erythropoietin.

To investigate the role of uremia in the development of human recombinant erythropoietin (r-HuEPO)-induced hypertension, Wistar rats were divided into a uremic (subtotal nephrectomy) and a control group. After three weeks, both groups were again divided and each subgroup received either r-HuEPO (100 u/kg s.c., 3 times weekly) or the vehicle for a further 3 weeks. Hematocrit, blood pressure and blood chemistry were measured prior to surgery, before either vehicle or r-HuEPO treatment and before euthanasia. The uremic group developed anemia, hypertension and all the biochemical features observed in humans with end-stage renal disease. r-HuEPO therapy increased hematocrit from 29 +/- 2.5% to 46 +/- 2% (p < 0.01) in the uremic rats. The mean baseline blood pressure was 119 +/- 10 mmHg. At week 3, mean blood pressure was unchanged in control rats, but it was increased to 151 +/- 5 mmHg (p < 0.01) in the nephrectomized group. At week 6, mean blood pressure in the untreated uremic rats remained unchanged from week 3, but blood pressure in the uremic animals treated with r-HuEPO increased significantly to 187 +/- 8 mmHg (p < 0.01). There was no significant correlation between hematocrit and blood pressure in the r-HuEPO treated uremic group (r = 0.01, NS). r-HuEPO had no effect on blood pressure in control rats despite a significant increase in hematocrit. These results indicate that the blood pressure response to r-HuEPO is enhanced in rats with chronic renal failure.

Animals↗

Multifrequency tympanometry and evoked otoacoustic emissions in neonates during the first 24 hours of life.

Multifrequency, complex-component tympanograms and transient evoked otoacoustic emissions (EOAEs) were recorded in 55 neonates less than 24 hours of age. The purpose of the investigation was to determine the normal middle ear immittance characteristics of neonates less than 24 hours old (the approximate discharge age of well-babies) and to assess whether an association exists between transient EOAE response and middle ear status in neonatal ears. The tympanometric patterns recorded in the 55 neonates were, in general, not typical of those observed in older children and adults. Complex patterns were recorded at low probe frequencies indicating differences in the contribution of mass, stiffness, and resistance elements to admittance in the neonatal middle ear. Results from EOAE screening indicated a pass rate or partial pass rate of 82 percent. Although no clear association emerged between admittance characteristics and EOAE results, some interesting tendencies were noted.

Acoustic Impedance Tests↗

Pathologic leukocyte infiltration of the rabbit aorta confers a vasomotor effect to chemotactic peptides through cyclooxygenase-derived metabolites.

We determined the effect of chemotactic peptides FMLP and C5a, postulated to be relatively selective activators of phagocytes, on the thoracic aorta of rabbits subjected to experimental pathologies that allowed infiltration by leukocytes, i.e., dietary atherosclerosis and serum sickness. Aortic ring tissues isolated from hypercholesterolemic rabbits, precontracted or not by phenylephrine, exhibited a rapid and relatively sustained (10 to 20 min) contractile response when challenged by FMLP (10 nM and above); precontracted tissues also responded to C5a (2.5 nM and above). Aortic rings from rabbits with serum sickness (13 days post-BSA injection) exhibited brief contractions that were often followed by a relaxation in phenylephrine-precontracted tissues. In both models, tissues from normal weight-matched animals were not consistently responsive to these peptides. The cyclooxygenase inhibitor indomethacin extensively reduced the contractile effect of either peptide on precontracted aortic rings in both models. Chemotactic peptide-induced increased prostanoid secretion was evident only in the fluid bathing atherosclerotic aortic rings. Morphologic correlations included the demonstration of cells positive for the RAM-11 macrophage marker and the C5a receptors in tissues from rabbits with hypercholesterolemia (numerous clusters of cells) or serum sickness (modest infiltration). Control aortic rings responded to FMLP by a significant contraction if cultured for 2 h in the presence of resident peritoneal cells (84% macrophages), but not in the presence of a high density of PBL (less than 0.5% monocytes). Infiltrating or adherent macrophages in the blood vessel wall confer to some phagocyte activating peptides the role of eicosanoid-dependent vasoconstrictor agents.

Animals↗

Eicosanoid modulation of the norepinephrine effect on blood pressure and renal hemodynamics in humans.

The main objective of this study was to investigate the role of eicosanoids in modulating the effect of norepinephrine (NE) on blood pressure and renal hemodynamics during NE administration. Eight healthy volunteers were randomly assigned to three (1 week apart) infusion periods (180 min) with either dextrose 5% or NE, with or without indomethacin pretreatment. Pressor doses of NE induced marked alterations in renal hemodynamics and concomitant increases in eicosanoid excretion rates. The production of the vasodilatory prostacyclin (PGI2), as reflected in the excretion rate of the stable metabolites 6-keto-prostaglandin (PG)F1(alpha) and 2,3-dinor-6-keto-PGF1(alpha), was 2.7 times higher than that of the constrictor thromboxane (TX)A2, which was measured as the stable derivative TXB2. Indomethacin pretreatment blunted the NE-induced augmentation in eicosanoid excretion and resulted in further increases in arterial pressure and in renal vascular resistance. These results demonstrate that PGI2 attenuates the systemic and the renal hemodynamic vasoconstrictor effect of NE in normotensive control normal subjects.

6-Ketoprostaglandin F1 alpha↗

Perceptual organization of sequential stimuli in listeners with cochlear hearing loss.

The perceptual organization of sequential stimuli presumably depends in part on the fidelity with which acoustic cues are encoded in the auditory system. The purpose of this study was to examine the effects of cochlear hearing loss on two measures of sequential processing that rely on spectro-temporal information. The results of a gap detection/discrimination task indicated that listeners with cochlear hearing loss exhibited particular difficulty discriminating gaps between tonal markers that were disparate in frequency. Performance improved when the disparate tones were embedded into a sequence of alternating low- and high-frequency tones that may have facilitated the perceptual of the stimuli into separate auditory streams. However, performance for listeners with cochlear hearing loss was generally poorer than that of normal-hearing listeners and did not appear to be related to threshold in quiet or to frequency selectivity. The results of a melody recognition task that required a target melody to be "heard out" from simultaneous competing melodies also indicated generally poorer performance on the part of the listeners with hearing loss, although the pattern of results across all listeners was highly idiosyncratic. It was concluded that cochlear hearing loss deleteriously affects the processes underlying perceptual organization of sequential stimuli. In particular, perceptual organization in the presence of cochlear hearing loss appears to require a greater frequency separation between presumed auditory streams in comparison to normal-hearing listeners.

Adult↗