Search PubMed⌕ Search

Biomedical subjects

J H Bahk

Publications and source records attributed to J H Bahk.

28 records · Page 2Linked to original sources

Management of difficult airways with a laryngeal mask airway under propofol anaesthesia.

We report four cases of difficult airway managed with a laryngeal mask airway (LMA) under propofol anaesthesia; this method was chosen to minimize psychological and physical trauma. Case 1 was a boy with dermatomyositis; Case 2, a girl wearing a base ring of a stereotactic frame; Case 3, a boy with Treacher-Collins syndrome; Case 4, a boy with Goldenhar syndrome. They were anaesthesized with propofol and though spontaneous ventilation became shallower, or apnoea occurred, the stimulus of inserting an LMA awakened the patient and caused more active spontaneous ventilation while a patent airway was established by the LMA. All tracheal intubations were performed smoothly and without delay through the LMA, and we believe that psychological and physical trauma was thus minimized.

Anesthesia↗

A new and simple maneuver to position the left-sided double-lumen tube without the aid of fiberoptic bronchoscopy.

UNLABELLED: The double-lumen tube (DLT) is the mainstay of one-lung ventilation (OLV). We sought to determine whether this new intubation maneuver using an endobronchial cuff pressure could be substituted for verification by fiberoptic bronchoscope (FOB) in most conditions requiring left-sided DLT. Seventy-nine patients requiring video-assisted thoracoscopic surgery for pneumothorax or mediastinal mass, or open thoracotomy for lung or esophageal cancer were enrolled in this study. We used 35F (n = 23), 37F (n = 51), or 39F (n = 5) disposable polyvinyl chloride DLTs (Broncho-Cath; Mallinckrodt Medical Ltd., Athlone, Ireland), depending on the height and gender of the patients. The DLTs were inserted deeply until resistance was felt. At that time, the pilot of the endobronchial cuff was connected to the Control-Inflator (VBM Medizintechnik GmbH, Sulz am Neckar, Germany) via a three-way stopcock. The bronchial balloon was inflated with 1.0-2.0 mL of air through the stop-cock until approximately 30 cm H2O of cuff pressure was obtained. The DLT was slowly withdrawn until the pressure of the Control-Inflator decreased to approximately half the peak pressure during the initial phase of removal. At that time, the bronchial balloon was deflated, and the DLT was advanced approximately 1.0 cm (1.5 cm for the 39F DLT); using FOB, its position was checked by an independent observer not involved in positioning the DLTs. The ideal position was defined as that in which the carina was located at the same level with the middle 5 mm between the proximal margin of the endobronchial balloon and the circumferential black mark. In 50 patients the position was ideal, and in 27 patients it was not ideal but was within the margin of the safety. There were only two failures. We conclude that if a FOB is unavailable or inapplicable, this simple and new maneuver may be used as a substitute during the positioning of DLTs. IMPLICATIONS: The correct position of the double-lumen tube is vital for one-lung ventilation, which has been confirmed with a fiberoptic bronchoscope. We devised a simple maneuver to position the double-lumen tube correctly without a fiberoptic bronchoscope.

Adolescent↗

Computed tomographic study of lumbar (L3-4) epidural depth and its relationship to physical measurements in young adult men.

BACKGROUND AND OBJECTIVES: This study was performed to devise a method for predicting epidural depth more accurately with a variety of physical measurements not previously studied. METHODS: Computed tomography was used to accurately measure the L3-4 epidural depth. The inclusion criteria were restricted to healthy men, 20-25 years of age, in order to rule out the influences of age and sex. RESULTS: Significant correlations with depth from skin to the center of the "triangular" posterior epidural space (Sk-Ep) were found for waist circumference, waist circumference/height ratio, body mass index (BMI), weight/height ratio, weight/neck circumference ratio, and weight. The depth from the supraspinous ligament to the center of the posterior epidural space (SI-Ep) did not correlate with any physical measurements. However, Sk-Sl, which equals Sk-Ep minus Sl-Ep (ie, the depth from the skin to the supraspinous ligament) correlated with waist circumference/height ratio, waist circumference, BMI, and weight/height ratio. CONCLUSION: Addition of the physical parameters such as waist circumference/neck circumference ratio or BMI results in a higher predictive value for epidural depth than use of more traditional physical parameters such as weight/height ratio and/or weight only. The value of Sl-Ep is independent of any physical parameters. Thus, the significant correlation between the physical measurements and the epidural depth seems to be due only to obesity-related factors.

Adult↗

Comparison of central venous catheterization sites in infants.

This study aimed to compare the rates of success and complications between different sites of central venous catheterization in infants. A total of 272 infants were randomized to four groups: right subclavian group (G-RSCV), right internal jugular group (G-RIJV), left subclavian group (G-LSCV) and left internal jugular vein group (G-LIJV). In 77.2% of the patients, we successfully introduced a catheter at the first attempt. The rate of successful catheter placement was highest in the and LSCV 55.9%). With regard to complications, the rate of arterial puncture, guide wire advancement failure and malpositioning of the catheter were all significantly more frequent during SCV catheterization (SCV versus IJV: 10.1% versus 2.1%, 12.4% versus 0% and 13.4% versus 0.6%, respectively). Our results imply that IJV, especially RIJV, should be the first choice for central venous catheterization in infants.

Catheterization, Central Venous↗