Search PubMed⌕ Search

Biomedical subjects

J Gotman

Publications and source records attributed to J Gotman.

At least 37 records · Page 2Linked to original sources

Separation of spikes from background by independent component analysis with dipole modeling and comparison to intracranial recording.

OBJECTIVE: Epileptiform discharges can be objectively separated from the EEG background by independent component analysis (ICA) into the discharge's waveform and its spatial distribution. The correspondence between ICA components, including epileptiform transients extracted from the scalp EEG and intracranial epileptic fields, was investigated. METHODS: In 11 spike patterns from 8 patients, the scalp EEG data were decomposed by ICA. The corresponding averaged intracranial data were compared with the extracted epileptic components regarding the number of source patterns and source locations estimated from ICA maps. RESULTS: Clear epileptic components could be separated in 10/11 spike patterns. The number of epileptic components was identical to the number of intracranial field peaks in 7 spike patterns with simple intracranial fields, and was less in the remaining 3 patterns with complex intracranial peaks. The distance between the contact of the maximal intracranial field and the dipole location estimated by the single dipole model for the clearest epileptic component ranged from 4.7 to 31.9 mm. CONCLUSIONS: The number of epileptic ICA components largely matched the number of intracranial field patterns, and the dipole location estimated for the map of the clearest epileptic component was generally correct. This establishes the validity of epileptic components extracted by ICA from the scalp background.

Algorithms↗

Dipole modeling of scalp electroencephalogram epileptic discharges: correlation with intracerebral fields.

OBJECTIVE: In order to evaluate the feasibility of modeling seizures and the reliability of dipole models, we compared source localizations of scalp seizures with the distribution of simultaneous intracerebral electroencephalogram (SEEG). METHODS: In a first session, only scalp electroencephalogram (EEG) was recorded from 15 patients. We averaged the first detectable ictal activity in two consecutive segments of stable topography and morphology. Spatio-temporal dipole sources were estimated for each segment and projected on 3D-magnetic resonance images. In a second session, SEEG was recorded simultaneously with control scalp electrodes, allowing the identification of ictal patterns similar to those submitted to dipole modeling. RESULTS: Ictal discharges could be analyzed in only 6 of 15 patients. In the remaining 9, scalp discharges were undetectable or non-reproducible in 6, and solutions were unstable despite an apparently stable discharge in 3. In the 6 patients successfully modeled, dipoles were found in regions where SEEG discharges were present. However, when intracerebral discharges were very focal, there was no corresponding scalp activity. When intracerebral signals were maximal in the mesial temporal regions at the seizure onset, only lateral neocortical dipoles were found. When discharges reached the frontal lobes, we could identify lateral and mesial frontal sources. CONCLUSIONS: In most seizures, it was not possible to obtain satisfactory dipole models, probably a reflection of the high noise level or widespread generators. When modeling was possible, our results suggested that mesial temporal seizure discharges did not contribute to scalp EEG activity. This activity appears to reflect signals synchronized and distributed over the lateral temporal or frontal neocortex, as well as signals generated in mesial frontal areas.

Cerebral Cortex↗

The influence of electrode location errors on EEG dipole source localization with a realistic head model.

OBJECTIVES: Inaccurate information about the electrode locations on the scalp will introduce errors in electroencephalogram dipole source localization results. The present study uses computer simulations to evaluate such errors in a realistic head model and in the context of noise. METHODS: A realistic head model was constructed from magnetic resonance imaging scans and 29 electrodes placed on the head according to the 10-20 International System. Twenty sets of electrode displacements, with a mean value of 5 mm, were generated and 200 single dipoles evenly located in the brain were used as test sources. The boundary element method was employed for the forward calculation and dipole fitting was carried out at different noise levels. RESULTS: For a noise-free signal, the source localization error due to electrode misplacement is about 5 mm, whereas it is about 2 mm for normal noisy signals. CONCLUSIONS: For realistic head models, dipole estimation error due to electrode misplacement is negligible compared with errors caused by noise.

Artifacts↗

Time course of postoperative recovery of N-acetyl-aspartate in temporal lobe epilepsy.

PURPOSE: To assess the time course of increases in N-acetyl-aspartate/creatine (NAA/Cr), which can be measured using proton MR spectroscopic imaging (1H-MRSI), in patients with intractable nonlesional temporal lobe epilepsy (TLE) after successful epilepsy surgery. METHODS: We performed pre- and postoperative 1H-MRSI in 16 seizure-free (SF) patients and 16 not seizure-free (NSF) TLE patients. We calculated a mixed-design analysis of variance (ANOVA) between SF and NSF groups, ipsi- and contralateral to the side of operation, and pre- and postoperative NAA/Cr measurements. We applied nonlinear regression between pre- and postoperative NAA/Cr differences and the time interval between 1H-MRSI scans to fit a negative exponential model to NAA recovery. RESULTS: Mixed-design ANOVA revealed that (a) postoperative NAA/Cr was significantly higher in SF than in NSF patients (p = 0.02) and that (b) in the SF group, postoperative NAA/Cr values were significantly higher than preoperative values (p < 0.05) and returned to the normal range in most patients. According to our nonlinear regression model, in SF patients, there was a 50% increase relative to preoperative NAA/Cr values after 5.8 months, whereas an improvement of 95% was reached after 25 months. CONCLUSIONS: Our results extend preliminary observations of postoperative NAA recovery of SF patients by characterizing the time course of recovery as an exponential function with a half-time of approximately 6 months. The reversal of neuronal metabolic dysfunction remote from the epileptic focus may underlie the clinical observation of improvement of cognitive dysfunction after successful epilepsy surgery.

Adolescent↗

Computer-assisted sleep staging.

To address the subjectivity in manual scoring of polysomnograms, a computer-assisted sleep staging method is presented in this paper. The method uses the principles of segmentation and self-organization (clustering) based on primitive sleep-related features to find the pseudonatural stages present in the record. Sample epochs of these natural stages are presented to the user, who can classify them according to the Rechtschaffen and Kales (RK) or any other standard. The method then learns from these samples to complete the classification. This step allows the active participation of the operator in order to customize the staging to his/her preferences. The method was developed and tested using 12 records of varying types (normal, abnormal, male, female, varying age groups). Results showed an overall concurrence of 80.6% with manual scoring of 20-s epochs according to RK standard. The greatest amount of errors occurred in the identification of the highly transitional Stage 1, 54% of which was misclassified into neighboring stages 2 or Wake.

Adolescent↗

Sensorimotor organization in patients who have undergone hemispherectomy: a study with (15)O-water PET and somatosensory evoked potentials.

To identify cortical structures that subserve residual motor and sensory function in patients with congenital hemiparesis due to a porencephalic cyst, we examined, using [(15)O]H2O, PET and somatosensory evoked potentials (SEPs) in three patients with left-sided hemiparesis who had undergone hemispherectomy. Motor stimulation of the affected hand produced ipsilateral activation in the premotor area in all patients, the SMA in two patients, and SII in two patients. Vibrotactile stimulation resulted in activation of the ipsilateral SII in all subjects. Median nerve stimulation of the affected hand produced ipsilateral long-latency SEPs in fronto-centro-parietal areas, whereas stimulation of the non-affected hand produced normal early cortical potentials in the contralateral hemisphere. Our results suggest that residual function in the paretic hand is warranted through non-primary motor and sensory areas, and higher order associative areas in the intact hemisphere.

Adult↗

The electroencephalogram through a software microscope: non-invasive localization and visualization of epileptic seizure activity from inside the brain.

OBJECTIVE: We developed a novel non-invasive analysis to localize the source and visualize the time course of electrical activity generated inside the brain but unclear from the scalp. This analysis applies to signals with unique waveform characteristics, such as seizures. METHODS: The method extracts activity from an EEG data matrix as a spatiotemporal component having waveforms uncorrelated to the other concurrent activities. The method also provides the location and orientation of the dipole generating this activity. We applied this method to ten scalp seizures in three patients with temporal lobe epilepsy and single-focus seizures confirmed by intracerebral recordings. A realistic head model based on MRI was used for computation of field distributions. RESULTS: When seizure activity was still not visually identifiable on the scalp, the method demonstrated in all scalp seizures a source in the temporal neocortex corresponding clearly to the region of seizure activity in intracerebral recordings. Frequency characteristics of the estimated activities also resembled those of the intracerebral seizures. CONCLUSIONS: This method enables estimation of focal brain activity when its effect on scalp EEG is unclear to visual examination. It works in situations where currently available source analyses methods, which require noiseless definite activity, are not applicable.

Brain↗

Using weighted linear spatial decomposition to investigate brain activity through a set of fixed current dipoles.

OBJECTIVES: We developed a method with the aim of decorrelating scalp EEG based on a set of spatial constraints. METHODS: We assume that the scalp EEG can be modelled by a small number of current dipoles of fixed location and orientation, placed at regions of interest. The algorithm is based on weighted linear spatial decomposition in order to obtain a weighted solution to the inverse problem. An EEG data matrix is first weighted in favour of a single dipole in the set. The dipole moment is then calculated from the weighted EEG by the pseudo-inverse method. This is repeated for each dipole. RESULTS: Six seizures were processed from 4 patients using the standard least-squares solution and our weighted version. The average cross-correlation between channels was calculated for each case. The first method resulted in a mean drop in cross-correlation of 16.5% from that of the scalp. Our method resulted in a reduction of 34.5%. CONCLUSIONS: Our method gives a more spatially decorrelated signal in regions of interest (although it is not intended as an accurate localization tool). Subsequent analysis is more robust and less likely to be dependent on specific recording montages. This is more than could be obtained using a standard least-squares solution using the same model.

Brain↗

EEG telemetry with closely spaced electrodes in frontal lobe epilepsy.

The use of additional electrodes (other than standard 10-20 electrodes) has proved to be extremely useful in the investigation of patients with temporal lobe epilepsy. The development of 32- and 64-channel EEG machines, along with the reformatting capabilities of digital EEG has greatly increased the possibilities in the number of electrodes and recording montages. The authors wanted to determine whether the use of closely spaced electrodes designed to increase the coverage of frontocentral regions is of benefit in the investigation of patients with frontocentral epilepsy. Patients investigated for frontocentral epilepsy underwent EEG telemetry with closely spaced electrodes based on the 10-10 nomenclature. Twenty-three patients were studied. An additional 30 minutes was required by technicians to create the montage. Unilateral frontal or frontocentral epileptic abnormalities were observed in 10 patients, independent bifrontal in 5 patients, synchronous bifrontal in 4 patients, and no EEG changes in 4 patients. In no patient did the addition of closely spaced electrodes lead to a change in the classification of the EEG. Closely spaced electrodes did not reveal focal abnormalities, which were not already apparent with 10-20 electrodes, nor did they demonstrate evidence of laterality in bilaterally synchronous discharges.

Electrodes↗

Relationships between the epileptic focus and hand area in central epilepsy: combining dipole models and anatomical landmarks.

OBJECT: When considering resection of epileptic generators near the central sulcus, it is essential to define the spatial relationship between the epileptic generator and the primary sensorimotor hand area. In this study, the authors assessed the accuracy of dipole modeling of electroencephalographic spikes and median nerve somatosensory evoked potentials (SSEPs) in defining this relationship preoperatively and noninvasively. METHODS: Epileptic spikes and SSEPs in patients with focal central area epilepsy were represented by dipole models coregistered onto global magnetic resonance images. In patients who underwent surgery, spike dipoles were also compared with findings of electrocorticography (ECoG) and with the resection area. To improve the accuracy of the dipole models, anatomical landmarks of the hand area were used to assess the error in SSEP dipole location, and this error measure was used to correct the location of spike dipoles. Five patients with central epilepsy were studied, three of whom underwent ECoG-guided surgical resections. The location of SSEP dipoles correlated well with anatomical landmarks of the primary sensory hand area. The relative position of the spike and SSEP dipoles correlated well with the patients' ictal symptoms, ECoG findings, and the location of the epileptic focus (as defined by the resection cavity in patients who became seizure free postoperatively). Corrected spike dipoles were located even closer to the resection cavity. CONCLUSIONS: The calculation of the relative location of spike and SSEP dipoles is a simple noninvasive method of determining the relationship between the primary hand area and an epileptic focus in the central area. The spatial resolution of this technique can be further improved using easily identifiable anatomical landmarks.

Adolescent↗

Correlation of high-frequency oscillations with the sleep-wake cycle and cognitive activity in humans.

While several authors have suggested that high-frequency electroencephalogram activity (gamma, >30 Hz) correlates with conscious thought, others have suggested that electroencephalogram activity >30 Hz shows the same relationships to cognitive activity and sleep as activity in the conventional beta frequency band. The existence of coherence of gamma over large distances also remains controversial. We studied quantitatively the relationship of gamma activity to the sleep-wake cycle and cognitive tasks during wakefulness in humans using intracranial electroencephalogram. Gamma activity made up less than 1% of the total power spectrum. A significant relationship was observed between gamma activity and the sleep-wake cycle such that gamma was highest during wakefulness, intermediate during light and rapid eye movement sleep, and lowest during slow-wave sleep. As well, gamma was higher during rapid eye movement sleep with eye movements than during rapid eye movement sleep without eye movements. During a cognitive task experiment, while lower frequencies, including beta, showed a stepwise reduction with increasing task difficulty, gamma was observed to increase during cognitive tasks as compared to the resting state. The relationship between gamma and the sleep-wake cycle and cognitive tasks was independent of brain region and hemisphere. Coherence of gamma activity at distances of 5 mm and greater was not observed. Our data support previously reported findings that gamma activity has a significant relationship to the sleep-wake cycle. The findings of differences in gamma during REM sleep with and without eye movements suggest that the presence or absence of eye movements may reflect two different states of brain activity. Our findings of differences in the relationships of the beta and gamma bands to both the sleep-wake cycle and cognitive tasks demonstrate that various components of the high-frequency spectrum behave differently in some situations.

Adolescent↗

Computerized EEG monitoring.

Monitoring of central nervous system function in the intensive care unit is becoming more widely accepted as an integral part of critical care. The history of developments in electroencephalogram (EEG) technology is reviewed to better appreciate the rate of technological developments and their application to clinical practice. Basic concepts of digital EEG are reviewed. Principals of intensive care unit monitoring as they apply to clinical neurophysiological techniques are examined to better understand the goals for an "ideal central nervous system monitor." Some current advances and directions for future development in computerized EEG monitoring are discussed.

Brain Diseases↗

Reliability of dipole models of epileptic spikes.

OBJECTIVE: In order to validate dipole-modeling results, we compared dipole localizations with the distribution of intracerebral potentials occurring simultaneously with scalp EEG paroxysms. METHODS: Firstly, scalp EEGs were recorded from 11 patients. Dipole sources were estimated on averaged spikes and projected on 3D-MRIs. Secondly, stereoelectroencephalography (SEEG) was recorded from implanted electrodes with direct identification onto MRI. Simultaneously with SEEG, control scalp electrodes were pasted where spikes peaked during the first session. SEEG was averaged, triggered by the main peak of scalp spikes. RESULTS: SEEG activity during scalp spikes always involved several contacts. In 13 of 14 spikes, maximal fields occurred in neocortical regions. In 4 of 5 cases where intracerebral activity was simple, spikes could be modeled by one source. In all cases where intracerebral activity was complex, spikes had to be modeled by several sources. The main dipole source was 11 +/- 4.2 mm from the SEEG contact showing the maximal intracerebral potential. Early and late dipole localization and SEEG fields were concordant in two thirds of cases. CONCLUSION: Results indicate that in our group of patients scalp spikes reflect activity in large neocortical areas and never activity limited to mesial structures. Dipole locations and time activation were confirmed most often and were more reliable for sources representing the main negative component than for early or late sources.

Adolescent↗

Isolation of epileptiform discharges from unaveraged EEG by independent component analysis.

OBJECTIVE: We propose a method that allows the separation of epileptiform discharges (EDs) from the EEG background, including the ED's waveform and spatial distribution. The method even allows to separate a spike in two components occurring at approximately the same time but having different waveforms and spatial distributions. METHODS: The separation employs independent component analysis (ICA) and is not based on any assumption regarding generator model. A simulation study was performed by generating ten EEG data matrices by computer: each matrix included real background activity from a normal subject to which was added an array of simulated unaveraged EDs. Each discharge was a summation of two transients having slightly different potential field distributions and small jitters in time and amplitude. Real EEG data were also obtained from three epileptic patients. RESULTS: Through ICA, we could isolate the two epileptiform transients in every simulation matrix, and the retrieved transients were almost identical as the originals, especially in their spatial distributions. Two epileptic components were isolated by ICA in all patients. Each estimated epileptic component had a consistent time course. CONCLUSION: ICA appears promising for the separation of unaveraged spikes from the EEG background and their decomposition in independent spatio-temporal components.

Algorithms↗

Automatic detection of seizures and spikes.

The recording of seizures and spikes is of primary importance in the evaluation of epileptic patients. This is not always an easy process because these events can be rare and are usually unpredictable. Since the earliest days of computer analysis of the EEG, researchers have developed methods for the automatic detection of spikes and, more recently, of seizures. The problems are complex because spikes and seizures are not clearly defined and have extremely varied morphologies. Nevertheless, it has been possible to develop automatic detection methods that can be of great assistance during long-term monitoring of epileptic patients. No method is absolutely fail-safe and all require human validation, but they save a considerable amount of time in the interpretation of long recordings. Recent developments include detection of the patterns specific to newborns, and the possibility of warning a patient or observer that a seizure is starting.

Diagnosis, Computer-Assisted↗

Intracranial EEG with very low frequency activity fails to demonstrate an advantage over conventional recordings.

PURPOSE: Conventional scalp and intracranial EEG is recorded within a limited band of frequencies (0.3-70 Hz) based on the premise that clinically relevant cerebral activity occurs within this frequency range. Ikeda et al. recently demonstrated focal very low frequency activity (VLFA), <0.3 Hz, at seizure onset for both intra- and extracranial recordings. The purpose of this investigation was prospectively to study VLFA during seizures in intracranial recordings to determine whether activity in this frequency range provides useful information regarding localization of seizure onset and spread. METHODS: Patients undergoing intracranial electrode implantation were studied by using a high-pass filter of 0.01 Hz. The timing, location, and pattern of seizure onset were first determined by using a digital high-pass filter of 0.3 Hz (conventional seizure onset). Seizures were then reviewed without digital filters and the presence of VLFA recorded, along with its timing and location. RESULTS: Forty-seven seizures were recorded in four patients. VLFA was not observed in 29 seizures and, in one other case, VLFA occurred simultaneous with movement. Of seizures with VLFA (n = 17), the timing and location of VLFA were not consistent with those of conventional seizure onset or propagation. CONCLUSIONS: Our study failed to demonstrate any clinical advantage of intracranial telemetry recordings with a high-pass filter of 0.01 Hz over conventional recordings with regard to determining the timing and location of seizure onset and propagation.

Adolescent↗