[Evaluation of rapid gradient-echo and turbo-spin-echo sequences in MRT of focal liver lesions using 0.5 tesla].

The value of rapid T1- and T2-weighted fast field (T1-FFE, T2-FFE) gradient-echo sequences and T2 weighted turbo-spin echo (TSE) sequences in the diagnosis of focal liver lesions using 0.5 Tesla was compared with conventional spin-echo sequences (SE). Amongst 88 liver lesions T1-SE sequences showed 98%, T2-TSE sequences showed 92%, T2-SE sequence showed 84%, T1-FFE sequence showed 78% and T2-FFE sequence showed 69%. Direct comparison has shown that TSE sequences are able to demonstrate significantly more lesions (p < 0.05) than T2-SE sequences. Quantitative assessment has shown that the tumor/liver contrast/noise ratio in the T1-SE sequence was 118% higher than in the T1-FFE sequence (p < 0.001). Comparison of T2 weighted sequences has shown that the tumour/liver contrast/noise ratio was 45% higher in the TSE sequence than in the T2-SE and 239% higher than in the T2-FFE sequence (p < 0.001). The results indicate that the TSE sequence should be used instead of the conventional T2-SE sequence because of the reduced time (about 40%), due to improved image quality and increased demonstration rate of liver lesions. Neither T1-FFE nor T2-FFE are suitable, when using moderate field strength, to replace T1-SE or TSE sequences.

Adenocarcinoma↗

[MR angiography of the heart and thoracic blood vessels. Use of rapid ECG-triggered techniques with multiplanar reconstruction capability].

Segmented 2D times-of-flight (TOF) magnetic resonance angiography (MRA) with ECG gating is a suitable adjunct to conventional magnetic resonance tomography. Based on our experience with 106 patients, cardiovascular MRA primarily aids in the diagnosis of congenital heart disease, but is of minor importance for the evaluation of acquired cardiovascular disease, such as aortic aneurysms. Changes in flow dynamics as a result of spin dephasing may render partial signal loss. Due to flow turbulence and resulting signal loss distal to stenoses, difficulties may arise in correctly determining the degree of stenosis and differentiating between partial thrombosis and slowly flowing blood. The most promising approach for optimizing 2D TOF MRA is enhancement of the intravascular signal and suppression of background signal. For the equipment we use with a 0.5 Tesla scanner, the most powerful combination to enhance intravascular signal and suppress back-ground noise was applying a flip angle of 65 degrees and a short inversion prepulse. The influence of the flip angle and prepulse on the intravascular signal varies, dependent on the flow velocities and heart rates. Secondary reconstructions, such as the MIP technique, contribute to better spatial orientation by using rotating projection views. To avoid overprojection artifacts and loss of diagnostic information, 2D single slices should be the primary source of image analysis.

Aortic Diseases↗

[Turbo(fast) spin echo at 0.5 T: effect of echo distance and echo number on image contrast].

Signal intensities, signal-to-noise ratios (S/N), and contrast-to-noise ratios (C/N) in dependence on the echo distance and echo number of the new turbo (fast) spin-echo technique are analysed by phantom, volunteer and patient measurements. With increasing echo number (3 to 15 echoes), signal intensities increase (25 to 50%), S/N varies between different tissues, and C/N of fat to water decreases (70%). A high echo number, although it shortens the imaging time, is thus not always the best choice since the fat/water contrast is lost. However, a high fat/water contrast is advantageous for several MR applications.

Arthritis, Rheumatoid↗

[Magnetic resonance tomography using the fast STIR technique: optimization and a comparison with other sequences in a 0.5-Tesla system].

One disadvantage of the STIR sequence in MRI is its long acquisition time. A TR shortening for acceleration requires shortening of the inversion time depending upon the field strength. We optimized this "fast-STIR" technique at 0.5 T using calculations, phantom, volunteer, and patient measurements. This optimization procedure is transferable to other field strengths. The resulting sequence takes 4.5 minutes, fat is visualised signal-free. In the second part of our study we compared quantitatively and qualitatively the signal intensities, contrast, and sensitivity towards artifacts of this sequence with that of conventional SE and GRE sequences in 21 patients with neoplastic, inflammatory and traumatic disorders of the musculoskeletal system. The fast-STIR sequence showed similar or better lesion contrast as SE in 100% and as GRE in 88%. Decreased spatial resolution and higher sensitivity towards pulsatile artifacts of the fast-STIR sequence were only minor drawbacks.

Achilles Tendon↗

Cardiac abnormalities: assessment with T2-weighted turbo spin-echo MR imaging with electrocardiogram gating at 0.5 T.

PURPOSE: To evaluate the cardiovascular system with magnetic resonance (MR) imaging performed with the turbo spin-echo (TSE) method and electrocardiogram (ECG) gating. MATERIALS AND METHODS: ECG-gated T2-weighted TSE images were obtained in 52 patients with 68 pathologic conditions (intracardiac [n = 18], myocardial [n = 23], pericardial [n = 6], paracardial [n = 10], or aortic [n = 11] disease) and 10 healthy subjects. In healthy subjects, TSE parameters were tested and optimized, and signal-to-noise ratios (S/Ns) and contrast-to-noise ratios (C/Ns) were determined. Delineation of the endo-, epi-, and pericardial borders and signal intensity characteristics of myocardium, fat, pericardium, blood flow, tumors, and clots were assessed. RESULTS: The TSE method provided good-quality T2-weighted images with sharp edge definition in a short imaging time. Increasing the turbo factor reduced motion artifacts and preserved the S/N and C/N. TSE images also helped in diagnosis of tumors, pleural effusions, inflammatory changes, and intravascular clots. CONCLUSION: TSE MR imaging is a feasible alternative to time-consuming conventional SE MR imaging, reduces motion artifact, and may help in evaluation of the cardiovascular system.

Adipose Tissue↗

[Intracranial ECoG electrodes. Location determination using three-dimensional reconstruction of MR data of the brain as a component of the presurgical diagnosis of epilepsy].

Subdural strip electrodes or intracerebral electrodes are required in order to precisely localize epileptic foci, which is mandatory for epilepsy surgery. The subdural electrodes are inserted via a borehole and thus precise positioning cannot be directly monitored. Therefore, the location of the electrodes in relation to the gyri and sulci has to be determined by imaging techniques. In this study, a three-dimensional magnetic resonance imaging (3D MRI) technique was used for visualization of intracranial EEG electrodes. A 3D gradient echo sequence with thin slices of 1 mm is required for the assessment of the gyral anatomy of the brain surface. Using a short repetition time of 30 ms good image quality within an acceptable acquisition time of about 15 min was possible. Post-processing with 3D surface reconstruction was performed using a Sun workstation. Three-dimensional reconstruction allows a more precise delineation of the localization of the EEG electrodes and the simultaneous display of the adjacent brain structures. Misplacement of intracranial electrodes is readily detected. 3D MRI with 3D surface reconstruction proved superior to 2D imaging and CT for the assessment of EEG electrode localization.

Electrodes↗

[MR tomography of the temporomandibular joint using T1-weighted multislice-gradient echo-sequences].

31 examinations of temporo-mandibular joints, using T1-weighted multislice gradient echo sequences have been performed. The short scan time of one minute and 50 seconds ensured that there were no movement artefacts in 28 cases. The position of the disc was visible in more than 90% of examinations. Degenerative changes in the cartilage and arthroses of the joint cannot be demonstrated adequately by the rapid sequences.

Adult↗

[Artifact reduction via motion-compensating gradient shifting in MR tomography].

In 62 patients spinecho or gradientecho sequences compensated for motion were compared with corresponding non-compensated sequences. Compensation during MRT reduces those artifacts which are caused by regular motion. This is particularly effective during examination of the brain stem, spinal canal and the heart. The improved demonstration of the morphology of normal and diseases organs simplifies the analysis of the types of movement.

Brain↗

[Use of a homomorphic filter in combination with surface coils in MR tomography].

A new method for correcting the signal intensity from surface coil (homomorphic filters) was evaluated in 40 examinations. With this filter it is possible to compensate for signal loss when using surface coils for deep tissues and to avoid excessive signals from the surface. The method does not, however, provide any additional information. Properly used, there were no false positive findings, nor was there any loss of abnormal findings. The use of homomorphic filters is therefore safe and sensible.

Filtration↗

[Optimization of examining sequences in MR tomography using isosignal displays].

Contrast performance in MR tomography is influenced by the choice of technical parameters such as pulse repetition time (TR), echo time (TE) and inversion time (TI) in the same manner as by differences in the tissue parameters relaxation time and proton density. To optimise image contrast it is therefore suggested to preselect the imaging sequence. Such presselection is possible on the basis of isosignal visualisations S(T1, T2). In the inversion recovery sequence (IR) the isosignal images obtained with the parameters TE, TI, TR enable determination of relaxation time T1 by graphic representation, from the time of zero passage of the longitudinal tissue magnetisation.

Humans↗

[Cardiac MRT. Research technic and topographic anatomical imaging information].

ECG-triggered cardio-MRT, using T1-weighted SE sequences, provides images of the heart showing very high anatomical resolution. So far, however, it has not been possible to demonstrate the morphology of the valves and coronary vessels. By using multiplanar sections, it is possible to obtain cuts which are perpendicular to the portion of myocardium or valve under consideration. This provides optimal imaging for morphological diagnosis and for evaluating the ventricular myocardium and its function.

Coronary Vessels↗

[Magnetic resonance tomography (MRT) of the orbit].

By using high field strengths and surface coils, MRT achieves a resolution comparable with CT in the orbita. The advantages of MRT are good contrast resolution and imaging in several planes. Twenty-six patients have been examined by MRT, which has shown high sensitivity and good detail for the demonstration of pathological changes. In spite of this, MRT at present is not a realistic alternative to ultrasound and CT, because it is unable to demonstrate bone and calcification; its specificity is low, but the time and cost of the examination is high. It is indicated only for problems involving the optic nerve and chiasma.

Adolescent↗

[Rapid MR tomography of the liver. Technic and initial results].

The fast-field-echo (FFE) sequence provides a new rapid imaging method for MR tomography. By using gradient echoes with shorter high frequency pulse repetitions than conventional sequences with 180 degrees echo pulses, it is possible to produce single cuts in 10 to 20 s with good signal-to-noise ratio. In this way the liver can be examined while respiratory movement artifacts are reduced. The possibility of obtaining T1- and T 2-weighted FFE images with good contrast resolution and the ability to determine relaxation times suggests a wide application of this rapid imaging procedure in the diagnosis of liver disease.

Carcinoma, Hepatocellular↗

[Modified T2-weighted gradient echo sequence for MR tomography of the CNS].

We introduced a modification of T2-weighted rapid sequence imaging which combines the advantages of conventional spin echo sequences with those of gradient echo sequences. It provides a method which is suitable for clinical routine use. Using a 1.5 Tesla field, one obtains good image quality with contrast comparable to spin echo sequences, while reducing the time taken to examine the brain to one-half and that of the spine to one-third. Our experience in 54 patients is described.

Brain↗