Publications and source records attributed to J Geoffrey Chase.

At least 19 recordsLinked to original sources

Parameter identification and sedative sensitivity analysis of an agitation-sedation model.

Sedation administration and agitation management are fundamental activities in any intensive care unit. A lack of objective measures of agitation and sedation, as well as poor understanding of the underlying dynamics, contribute to inefficient outcomes and expensive healthcare. Recent models of agitation-sedation dynamics have enhanced understanding of the underlying dynamics and enable development of advanced protocols for semi-automated sedation administration. In this research, the agitation-sedation model parameters are identified using an integral-based fitting method developed in this work. Parameter variance is then analysed over 37 intensive care unit patients. The parameter identification method is shown to be effective and computationally inexpensive, making it suited to real-time clinical control applications. Sedative sensitivity, an important model parameter, is found to be both patient-specific and time-varying. However, while the variation between patients is observed to be as large as a factor 10, the observed variation in time is smaller, and varies slowly over a period of days rather than hours. The high fitted model performance across all patients show that the agitation-sedation model presented captures the fundamental dynamics of the agitation-sedation system. Overall, these results provide additional insight into the system and clinical dynamics of sedation management.

Computer Simulation↗

A novel mechanical lung model of pulmonary diseases to assist with teaching and training.

BACKGROUND: A design concept of low-cost, simple, fully mechanical model of a mechanically ventilated, passively breathing lung is developed. An example model is built to simulate a patient under mechanical ventilation with accurate volumes and compliances, while connected directly to a ventilator. METHODS: The lung is modelled with multiple units, represented by rubber bellows, with adjustable weights placed on bellows to simulate compartments of different superimposed pressure and compliance, as well as different levels of lung disease, such as Acute Respiratory Distress Syndrome (ARDS). The model was directly connected to a ventilator and the resulting pressure volume curves recorded. RESULTS: The model effectively captures the fundamental lung dynamics for a variety of conditions, and showed the effects of different ventilator settings. It was particularly effective at showing the impact of Positive End Expiratory Pressure (PEEP) therapy on lung recruitment to improve oxygenation, a particulary difficult dynamic to capture. CONCLUSION: Application of PEEP therapy is difficult to teach and demonstrate clearly. Therefore, the model provide opportunity to train, teach, and aid further understanding of lung mechanics and the treatment of lung diseases in critical care, such as ARDS and asthma. Finally, the model's pure mechanical nature and accurate lung volumes mean that all results are both clearly visible and thus intuitively simple to grasp.

Education, Medical↗

Integral-based filtering of continuous glucose sensor measurements for glycaemic control in critical care.

Hyperglycaemia is prevalent in critical illness and increases the risk of further complications and mortality, while tight control can reduce mortality up to 43%. Adaptive control methods are capable of highly accurate, targeted blood glucose regulation using limited numbers of manual measurements due to patient discomfort and labour intensity. Therefore, the option to obtain greater data density using emerging continuous glucose sensing devices is attractive. However, the few such systems currently available can have errors in excess of 20-30%. In contrast, typical bedside testing kits have errors of approximately 7-10%. Despite greater measurement frequency larger errors significantly impact the resulting glucose and patient specific parameter estimates, and thus the control actions determined creating an important safety and performance issue. This paper models the impact of the continuous glucose monitoring system (CGMS, Medtronic, Northridge, CA) on model-based parameter identification and glucose prediction. An integral-based fitting and filtering method is developed to reduce the effect of these errors. A noise model is developed based on CGMS data reported in the literature, and is slightly conservative with a mean Clarke Error Grid (CEG) correlation of R=0.81 (range: 0.68-0.88) as compared to a reported value of R=0.82 in a critical care study. Using 17 virtual patient profiles developed from retrospective clinical data, this noise model was used to test the methods developed. Monte-Carlo simulation for each patient resulted in an average absolute 1-h glucose prediction error of 6.20% (range: 4.97-8.06%) with an average standard deviation per patient of 5.22% (range: 3.26-8.55%). Note that all the methods and results are generalizable to similar applications outside of critical care, such as less acute wards and eventually ambulatory individuals. Clinically, the results show one possible computational method for managing the larger errors encountered in emerging continuous blood glucose sensors, thus enabling their more effective use in clinical glucose regulation studies.

Adult↗

Simulating transient ventricular interaction using a minimal cardiovascular system model.

A minimal closed-loop cardiovascular system (CVS) model has been developed that can simulate ventricular interaction due to both direct interaction through the septum and series interaction through the circulation system. The model is used to simulate canine experiments carried out to study the transient response of the left ventricle due to changes in right ventricle pressures and volumes. The model-simulated trends in left and right ventricle pressures and volumes, septum deflection and arterial flow rates are compared with the experimental results. In spite of the limited physiological data available describing the animals, the model is shown to capture all the transient trends in the experimental data. This is the first known example of a physiological model that can capture all these trends. The model is then used to illustrate the separate effects of direct and series interactions independently. This study proves the value of this modelling method to be used in conjunction with experimental data for delineating and understanding the factors that contribute to ventricular dynamics.

Animals↗

A simple insulin-nutrition protocol for tight glycemic control in critical illness: development and protocol comparison.

BACKGROUND: Hyperglycemia is prevalent in critical care, and tight control can significantly reduce mortality. However, current protocols have been considered taxing to administer and may require extra staff. In addition, increased insulin resistance and saturation effects limit the level of control possible using insulin alone. Thus, regulating both insulin and exogenous nutritional inputs is required to control blood glucose. METHODS: A robust, easy-to-use protocol ["SPRINT" (Specialized Relative Insulin Nutrition Tables)] that employs both insulin and feed modulation is developed and analyzed using retrospective data from 19 patients with average Acute Physiology and Chronic Health Evaluation II score of 21.8. Results are compared with several published protocols in simulation, and verified in a proof-of-concept trial. RESULTS: In simulation, 61.7% of measurements were in the 75-110 mg/dL band and 83.5% in the 75-140 mg/dL band. Results from the simulation of published protocols agreed with published results. Clinically, for two patients, 64% and 85% of measurements were between 75 and 110 mg/dL during the two proof-of-concept trials. Total enteral feeding was similar to, or exceeded, retrospective data. CONCLUSIONS: Tight control was achieved in simulation using a protocol that is easy to implement in an intensive care unit. Similarly tight control was also maintained during the two proof-of-concept clinical trials. Measurement frequency of 1-2 h is seen to be critical to achieving and maintaining tight control. The overall SPRINT protocol is easy to use for clinical staff and effective in achieving and maintaining normoglycemia in critical illness.

Adult↗

Transient and steady-state euglycemic clamp validation of a model for glycemic control and insulin sensitivity testing.

BACKGROUND: There is an urgent need for a simple and accurate measure of insulin sensitivity to diagnose insulin resistance in the general population and quantify changes due to clinical intervention. A new physiological control model of glucose and insulin metabolism is validated with the euglycemic-hyperinsulinemic clamp during steady and transient states. METHODS: The data consist of n = 60 (15 lean, 15 overweight, 15 obese, and 15 morbidly obese) euglycemic-hyperinsulinemic clamp trials performed on normoglycemic insulin-resistant individuals. The glucose and insulin model is fitted using an integral-based method. Correlations between clamp-derived insulin sensitivity index (ISI) and the model's insulin sensitivity parameter (SI) are obtained during steady and transient states. Results are compared with log-homeostasis model assessment (HOMA), a widely used fasting surrogate for insulin sensitivity. RESULTS: Correlation between model-based insulin sensitivity, SI, and ISIG (ISI normalized by steady-state glucose) is r = 0.99 (n = 60) at steady state and r = 0.97 at transient state, respectively. Correlations did not significantly change across subgroups, with narrow 95% confidence intervals. Log-HOMA correlations are r=-0.72 to SI and r=-0.71 to ISIG for the overall population but are significantly lower in the subgroups, with wide 95% confidence intervals. CONCLUSIONS: The model-based insulin sensitivity parameter, SI, highly correlates to ISIG in all subgroups, even when only considering a transient state. The high correlation of SI offers the potential for a short, simple yet highly correlated, model-based assessment of insulin sensitivity that is not currently available.

Adult↗

A pilot study of the SPRINT protocol for tight glycemic control in critically Ill patients.

BACKGROUND: Stress-induced hyperglycemia is prevalent in critical care, even in patients with no history of diabetes. Increased counter-regulatory hormone response increases gluconeogenesis and effective insulin resistance, which can be exacerbated by drug therapy. Control of blood glucose levels to the 4.0-6.1 mmol/L range has been shown to reduce mortality and improve clinical outcomes. The Specialized Relative Insulin and Nutrition Tables (SPRINT) protocol is a simple alternative intensive care unit protocol for modulating insulin and nutritional input to gain tight blood glucose control in the 4.0-6.1 mmol/L target band. The look-up tables, implemented in a wheel-based format, are used by nurses to determine glycemic control actions based on hourly or 2-hourly blood glucose measurements and nutrition and insulin administration rates. METHODS: An 11 patient pilot study was conducted comprising 2,152 hours of blood glucose level control using the SPRINT protocol. The patient cohort average Acute Physiology and Chronic Health Evaluation II score was 22, which was higher than previous intensive insulin clinical studies. RESULTS: Overall, 64% of measurements were in the 4.0-6.1 mmol/L band, 89% in the 4.0-7.0 mmol/L band, and 96% of all measurements in the 4.0-7.75 mmol/L band. The average value was 5.8 +/- 0.9 mmol/L. Only 1.4% of all measurements were below 4 mmol/L, with a minimum of 3.2 mmol/L. The maximum value recorded was 11.8 mmol/L. CONCLUSIONS: Control of blood glucose level was achieved using a protocol implemented by the nursing staff without the need for physician intervention or interpretation, where control is defined as maximizing time within a desired band. The results led to a high level of support for the SPRINT protocol among clinical staff and acceptance of the frequent measurement requirement for effective control. The ease-of-use of the protocol resulted in minimal noncompliance by clinical staff.

APACHE↗

Rethinking glycaemic control in critical illness--from concept to clinical practice change.

OBJECTIVE: To examine the practical difficulties in managing hyperglycaemia in critical illness and to present recently developed model-based glycaemic management protocols to provide tight control. BACKGROUND: Hyperglycaemia is prevalent in critical care. Current published protocols require significant added clinical effort and have highly variable results. No currently published methods successfully address the practical clinical difficulties and patient variation, while also providing safe, tight control. METHODS: We developed a unique model-based approach that manages both nutritional inputs and exogenous insulin infusions. Computerised glycaemic control methods and proof-of-concept clinical trial results are presented. The protocol has been simplified to a set of tables and adopted as a clinical practice change. Eight pilot test cases are presented to demonstrate the overall approach. RESULTS: Computerised control methods lowered blood glucose (BG) levels to the range 4.0-6.1 mmol/L within 10 hours. Over 90% of pre-set hourly blood glucose targets were achieved within measurement error. Eight pilot tests of the simplified, table-based SPRINT protocol, covering 1651 patient-hours produced an average BG level of 5.7 mmol/L (SD, 0.9 mmol/L). BG levels were in the 4.0-6.1 mmol/L band for 60% of the controlled time. Just under 90% of measurements were in the range 4.0-7.0 mmol/L, with 96% in the range 4.0-7.75 mmol/L. There were no hypoglycaemic episodes, with a minimum glucose level of 3.2 mmol/L, and no additional clinical intervention was required. SUMMARY: The overall approach of modulating nutrition as well as insulin challenges the current practice of relying on insulin alone to reduce glycaemic levels, which often results in large variability and poor control. The protocol was developed from model-based analysis and proof-of-concept clinical trials, and then generalised to a simple, clinical practice improvement. The results show extremely tight control within safe glycaemic bands.

Aged↗

Integral-based parameter identification for long-term dynamic verification of a glucose-insulin system model.

Hyperglycaemia in critically ill patients increases the risk of further complications and mortality. This paper introduces a model capable of capturing the essential glucose and insulin kinetics in patients from retrospective data gathered in an intensive care unit (ICU). The model uses two time-varying patient specific parameters for glucose effectiveness and insulin sensitivity. The model is mathematically reformulated in terms of integrals to enable a novel method for identification of patient specific parameters. The method was tested on long-term blood glucose recordings from 17 ICU patients, producing 4% average error, which is within the sensor error. One-hour forward predictions of blood glucose data proved acceptable with an error of 2-11%. All identified parameter values were within reported physiological ranges. The parameter identification method is more accurate and significantly faster computationally than commonly used non-linear, non-convex methods. These results verify the model's ability to capture long-term observed glucose-insulin dynamics in hyperglycemic ICU patients, as well as the fitting method developed. Applications of the model and parameter identification method for automated control of blood glucose and medical decision support are discussed.

Adult↗

A new model validation tool using kernel regression and density estimation.

In physiological system modelling for control or decision support, model validation is a critical element. A nonparametric approach for assessing the validity of deterministic dynamic models against empirical data is developed, based on kernel regression and kernel density estimation, yielding visual graphical assessment tools as well as numerical metrics of compatibility between the model and the data. Nonparametric regression has been suggested for assessing a parametric statistical model by constructing a confidence band for the proposed model and then checking whether the nonparametric regression curve lies within the band. However, for deterministic models, there is no confidence band that can be constructed. A reversal of roles is therefore suggested--construct a probability band for the nonparametric regression curve and check whether the proposed model lies within the band. This approach extends the utility of nonparametric regression for model assessment to deterministic models. Weighted kernel density estimation is incorporated to derive a density profile for the regression curve, creating a local graphical validation tool. In addition, the density profile is used to define and compute two numerical measures--average normalized density (AND) and relative average normalized density (RAND), representing global statistical validity measures. These tools are demonstrated using a biomedical system model for agitation-sedation and sedation management control.

Humans↗

Adaptive bolus-based targeted glucose regulation of hyperglycaemia in critical care.

Tight regulation of blood glucose can significantly reduce mortality in critical illness. Critically ill patients are extremely diverse in the dynamics of their hyperglycaemia. Hence, responses can vary significantly, due to variations in insulin levels, effective insulin utilization, glucose absorption and other factors. Consequently, fixed protocols and sliding scales can result in error, given this large variation in patient dynamics. A two-compartment glucose-insulin system model that accounts for time-varying insulin sensitivity and endogenous glucose removal, along with two different saturation kinetics, is developed and tested in preliminary proof-of-concept clinical trials for adaptive control of blood glucose levels. The adaptive control algorithm developed in this research monitors the physiological status of a critically ill patient, allowing real-time, tight glycaemic regulation. The bolus-based insulin administration provides a safe approach to glucose level management. The ability to track changing physiological status and account for insulin transport and effect saturation enabled targeted stepwise reduction in glycaemic levels in three test cases.

Adaptation, Physiological↗

Targeted glycemic reduction in critical care using closed-loop control.

BACKGROUND: Critically ill patients are often hyperglycemic and extremely diverse in their dynamics. Consequently, fixed protocols and sliding scales can result in error and poor control. Tight glucose control has been shown to significantly reduce mortality in critical care. An improved physiological system model of the glucose-insulin dynamics of a critical care patient is used to develop an adaptive tight glucose control protocol that accounts for variable patient dynamics, and is verified in limited clinical trials. METHODS: A physiologically based two-compartment system model that accounts for time-varying insulin sensitivity, time-varying endogenous glucose removal, and two saturation kinetics mechanisms is developed. A bolus-based adaptive control protocol is developed that monitors the physiological status of a critically ill patient, enabling tight glycemic regulation to preset glycemic targets. The model and protocol are verified in three, 5-h preliminary proof-of-concept clinical trials. Ethics approval was granted by the Canterbury Ethics Committee (Christchurch, New Zealand). RESULTS: Preset glycemic targets are achieved with an average absolute error of 9%, with 75% of all targets achieved within the 7% measurement error. Absolute errors greater than 7% ranged from 17% to 21%. CONCLUSIONS: Tight stepwise control was exhibited in all cases, and the adaptive system was able to match the model and observed patient dynamics. Most errors are associated with external perturbations such as drug therapies, or mismodeled parameters that can be easily adjusted with longer trials and/or more data per hour. The overall result is targeted stepwise tight glycemic regulation using insulin boluses.

Aged↗

Quantifying agitation in sedated ICU patients using digital imaging.

Agitation is a significant problem in the Intensive Care Unit (ICU), affecting 71% of sedated adult patients during 58% of ICU patient-days. Subjective scale based assessment-methods focused primarily on assessing excessive patient motion are currently used to assess the level of patient agitation, but are limited in their accuracy and resolution. This research quantifies this approach by developing an objective agitation measurement from patient motion that is sensed using digital video image processing. A fuzzy inference system (FIS) is developed to classify levels of motion that correlate with observed patient agitation, while accounting for motion due to medical staff working on the patient. Clinical tests for five ICU patients have been performed to verify the validity of this approach in comparison to agitation graded by nursing staff using the Riker Sedation-Agitation Scale (SAS). All trials were performed in the Christchurch Hospital Department of Intensive Care, with ethics approval from the Canterbury Ethics Committee. Results show good correlation with medical staff assessment with no false positive results during calm periods. Clinically, this initial agitation measurement method promises the ability to consistently and objectively quantify patient agitation to enable better management of sedation and agitation through optimised drug delivery leading to reduced length of stay and improved outcome.

Procedural Sedation↗

Minimal haemodynamic system model including ventricular interaction and valve dynamics.

Characterising circulatory dysfunction and choosing a suitable treatment is often difficult and time consuming, and can result in a deterioration in patient condition, or unsuitable therapy choices. A stable minimal model of the human cardiovascular system (CVS) is developed with the ultimate specific aim of assisting medical staff for rapid, on site modelling to assist in diagnosis and treatment. Models found in the literature simulate specific areas of the CVS with limited direct usefulness to medical staff. Others model the full CVS as a closed loop system, but they were found to be very complex, difficult to solve, or unstable. This paper develops a model that uses a minimal number of governing equations with the primary goal of accurately capturing trends in the CVS dynamics in a simple, easily solved, robust model. The model is shown to have long term stability and consistency with non-specific initial conditions as a result. An "open on pressure close on flow" valve law is created to capture the effects of inertia and the resulting dynamics of blood flow through the cardiac valves. An accurate, stable solution is performed using a method that varies the number of states in the model depending on the specific phase of the cardiac cycle, better matching the real physiological conditions. Examples of results include a 9% drop in cardiac output when increasing the thoracic pressure from -4 to 0 mmHg, and an increase in blood pressure from 120/80 to 165/130 mmHg when the systemic resistance is doubled. These results show that the model adequately provides appropriate magnitudes and trends that are in agreement with existing data for a variety of physiologically verified test cases simulating human CVS function.

Blood Flow Velocity↗

Modeling and control of the agitation-sedation cycle for critical care patients.

Agitation-sedation cycling in critically ill patients, characterized by oscillations between states of agitation and over-sedation, is damaging to patient health, and increases length of stay and healthcare costs. The mathematical model presented captures the essential dynamics of the agitation-sedation system for the first time, and is statistically validated using recorded infusion data for 37 patients. Constant patient-specific patient parameters are used, illustrating the commonality of these fundamental dynamics over a broad range of patients. The validated model serves as a basis for comparison of sedation administration methods, devices, therapeutics and protocols. Heavy derivative feedback control is shown to be an effective means of managing agitation, given consistent agitation measurement. The improved agitation management reduces the modeled mean and peak agitation levels 68.4% and 52.9% on average, respectively. Some patients showed over 90% reduction in mean agitation level through increased control gains. This improved agitation management is achieved via heavy derivative feedback control of sedation administration, which provides an essentially bolus-driven management approach, aligned with recent sedation practices.

Computer Simulation↗

Derivative weighted active insulin control modelling and clinical trials for ICU patients.

Close control of blood glucose levels significantly reduces vascular complications in Type 1 and Type 2 diabetic individuals. Heavy derivative controllers using the data density available from emerging biosensors are developed to provide tight, optimal control of elevated blood glucose levels, while robustly handling variation in patient response. A two-compartment glucose regulatory system model is developed for intravenous infusion from physiologically verified subcutaneous infusion models enabling a proof-of-concept clinical trial at the Christchurch Hospital Department of Intensive Care Medicine. This clinical trial is the first of its kind to test a high sample rate feedback control algorithm for tight glucose regulation. The clinical trial results show tight control with reductions of 79-89% in blood glucose excursions for an oral glucose tolerance test. Experimental performance is very similar to modelled behaviour. Results include a clear need for an additional accumulator dynamic for insulin behaviour in transport to the blood and strong correlation of 10% or less between modelled insulin infused and the amounts used in clinical trials. Finally, the heavy derivative PD control approach is seen to be able to bring blood glucose levels below the (elevated) basal level, showing the potential for truly tight control.

Aged↗

Quantifying agitation in sedated ICU patients using heart rate and blood pressure.

Agitation is a significant problem in the intensive care unit (ICU), affecting 71% of sedated adult patients during 58% of ICU patient-days (Fraser and Riker 2001 NY Health-Syst. Pharm. 20 17-24). Subjective scale-based assessment methods are currently used to assess the level of patient agitation, but are limited in their accuracy and resolution. This research develops an objective agitation measurement method using heart rate variability (HRV), systolic blood pressure (BP) and blood pressure variability (BPV) data, processed by wavelet transforms and autoregressive signal processing. A fuzzy inference system (FIS) is developed to classify changes in these signals that correlate with observed patient agitation, and combine them into a final agitation level. Proof of concept clinical trials on 13 normal subjects and 5 ICU patients has been performed to verify the validity of this approach in comparison with agitation graded by nursing staff using the Riker sedation-agitation scale (SAS). Results show good correlation with medical staff assessment with no false positive results during calm periods. Clinically, this initial agitation measurement method promises the ability to consistently and objectively quantify patient agitation to enable better management of sedation and agitation through optimized drug delivery leading to reduced length of stay.

Artificial Intelligence↗

Automated insulin infusion trials in the intensive care unit.

The objective is to demonstrate the effectiveness of a simple automated insulin infusion for controlling the rise and duration of blood glucose excursion following a glucose challenge in critically ill patients with impaired glucose tolerance. A two-compartment model of the glucose regulatory system was developed for intravenous infusion control design. On two subsequent days a critically ill patient with impaired glucose tolerance was given a 75 g oral glucose tolerance test (OGTT), and the glucose level was measured every 15 min. The first day's data were used to design a heavy-derivative insulin infusion controller for the second day. Ethics approval was granted for this test. Five patients were studied. In four patients, the magnitude and duration of blood glucose excursion were reduced over 50%. Fasting level was reduced 15%, from an average of 7.2 mmol/L to 6.1 mmol/L. The fifth patient's results showed a diminished response due to the antagonistic effects of hydrocortisone on insulin, a data point not provided prior to testing. Modeling to account for this effect yielded better correlation with the test. The automated algorithm provided rapid, effective control of the blood glucose rise in response to an OGTT input. These results highlight the effectiveness of automated infusions for regulating blood glucose rise and excursions, and the potential of this approach for non-hospitalized individuals.

Automation↗