J G Hardman

Publications and source records attributed to J G Hardman.

At least 19 recordsLinked to original sources

The development of hypoxaemia during apnoea in children: a computational modelling investigation.

BACKGROUND: Hypoxaemia during apnoea develops earlier and progresses faster in children than in adults. Ethical and practical considerations prevent detailed investigation of the issue. METHODS: We used the Nottingham Physiology Simulator, an integrated, computational model of the respiratory and cardiovascular systems, to model four healthy virtual children (ages: 1 month, 1, 8 and 18 yr) and exposed them to apnoea after a variety of preoxygenation periods (0, 1 and 3 min) and with open and obstructed airways during apnoea. RESULTS: The rate of oxygen desaturation of haemoglobin from 90 to 40% was similar across the ages studied, being approximately 30% min(-1). The greatest difference between ages was found in the speed of early desaturation (i.e. between the onset of apnoea and the acceleration of haemoglobin desaturation); in the absence of preoxygenation and with an open airway, this time was 6.6 s in the 1-month-old and 33.6 s in the 8-yr-old. CONCLUSIONS: Preoxygenation had a substantial effect on the speed of early desaturation, but less effect on the time for SaO2 to decrease from 90 to 40%. Preoxygenation substantially delayed dangerous desaturation in all age groups, although the rapidity of denitrogenation in the very young (caused by the large ratio of minute ventilation to functional residual capacity) resulted in lengthy preoxygenation having little benefit over brief preoxygenation. Airway obstruction during apnoea accelerated every child's hypoxaemia through prevention of mass flow addition to oxygen stores and through intrathoracic depressurization. On average, haemoglobin desaturation from SaO2 90 to 40% was 33% min(-1) with an obstructed airway and 26% min(-1) with an open airway; all ages were similarly susceptible to this effect.

Adolescent↗

The dependence of measured alveolar deadspace on anatomical deadspace volume.

BACKGROUND: Changes in pulmonary deadspace are indicators of disease status (e.g. pulmonary embolus, acute respiratory distress syndrome) and they have prognostic usefulness in the intensive care unit. The components of pulmonary deadspace, the alveolar and anatomical deadspaces (VDalv and VDanat), are commonly considered to be independent (i.e. the addition of airway equipment should not alter the measured VDalv). However, VDanat has been shown to affect VDalv in the absence of changes in alveolar ventilation or perfusion. We sought to quantify the variability in measured VDalv induced by changes in VDanat using a cardiorespiratory computational model. METHODS: Using the Nottingham Physiology Simulator, we examined three simulated ventilated patients with small, moderate and large ventilation-perfusion (VQ) defects. Each patient received 12.5 bpm x 500 ml. We varied VDanat between 50 and 250 ml, keeping the VQ ratio of each alveolus constant. We calculated VDalv by subtracting VDanat (measured using Fowler's technique) from the physiological deadspace (measured using the Bohr-Enghoff equation). We calculated fresh-gas tidal volume (VTfresh) by subtracting VDanat from the exhaled tidal volume and calculated VDalv/VTfresh. In the simulated patient with the large VQ defect, we performed the same protocol with tidal volumes of 750 and 1000 ml. RESULTS: When VDanat increased from 50 to 250 ml (500 ml tidal volume) VDalv decreased by 48.3% (mean value across the three VQ defects) and VDalv/VTfresh decreased by 15.1%. These relationships were similar at each tidal volume studied. CONCLUSIONS: Measured VDalv is altered by changes in VDanat despite constant VQ ratios in each alveolus. This has implications for the interpretation of deadspace measured in the clinical setting. The variability is less for the ratio VDalv/VTfresh.

Computer Simulation↗

Hypoxaemia during open-airway apnoea: a computational modelling analysis.

Hypoxaemia during open-airway apnoea, e.g. during brainstem death testing, may cause organ damage. The effect of ambient oxygen fraction on the extent of hypoxaemia has not been established. We validated the Nottingham Physiology Simulator in this context by reproducing the methodologies and results of four published clinical studies. We then used the simulator to examine the effects of different ambient oxygen fractions (0.21-1.0) and shunt fractions (1-30% of cardiac output) during apnoea. Increasing ambient oxygen fraction from 0.9 to 1.0 more than doubled the time to haemoglobin desaturation at all shunt fractions, and extended apnoea longer than when the ambient oxygen fraction was increased from 0.21 to 0.9. When ambient oxygen fraction and shunt fraction were large, arterial oxygen tension transiently increased during apnoea. A very high ambient oxygen fraction and a patent airway are likely to delay dangerous hypoxaemia during apnoea.

Apnea↗

Failed extubation of a double-lumen tube requiring a cricoid split.

Following a five-hour procedure, it was not possible to remove a double-lumen endobronchial tube that had been placed to facilitate the removal of a massive spleen from a 45-year-old female. The tube had been passed easily at the start of surgery, but was firmly stuck at the level of the cricoid at the end of surgery. Surgical removal of the tube by a cricoid split was required 48 hours later. Consideration of previous airway manipulations, careful choice of airway devices and regular checks of airway patency around tracheal tubes during lengthy procedures may prevent similar events in the future.

Airway Obstruction↗

The effect of a disposable probe cover on pulse oximetry.

The re-use of pulse oximeter probes presents the possibility of between-patient contamination. Use of a disposable polyethylene cover may reduce this risk. In a controlled, prospective study we examined the effect of such a cover on the accuracy of pulse oximetry. Each of ten volunteer subjects was monitored simultaneously by two identical Nellcor pulse oximeters, one with a plastic cover and the other, without a cover, used as a control. The pulse oximetry (SpO2) reading for each probe was recorded while subjects breathed 21% O2 and again while they breathed 10% O2. The probe cover was then swapped onto the other probe and the recordings were repeated. Ninety-five per cent limits of agreement in SpO2 (mean difference in SpO2 (1.95 x standard deviation of difference) between covered and non-covered probes were -0.6% to 0.6% while breathing 21% oxygen and -2.0% to 2.9% while breathing 10% oxygen. We conclude that a protective plastic sheath may induce a small error in pulse oximetry reading that is most marked during hypoxaemia. This error is unlikely to be of clinical significance.

Adult↗

The effect of continuous positive airway pressure on cerebral blood flow velocity in awake volunteers.

We measured the effect of 5 and 10 cm H(2)O continuous positive airways pressure (CPAP) on middle cerebral artery blood flow velocity (FV) in 15 awake, healthy volunteers by using transcranial Doppler ultrasonography. Mean, systolic, and diastolic FV plus pulsatility index were recorded. No significant change in any measured variable was observed with the application of 5 or 10 cm H(2)O CPAP. These results are in contrast to those of a previous study, which found a significant increase in mean FV and a decrease in pulsatility index during the application of 12 cm H(2)O CPAP.

Adult↗

Investigating hypoxemia during apnea: validation of a set of physiological models.

UNLABELLED: The aim of our study was to validate the Nottingham Physiology Simulator (NPS) for examining pulmonary denitrogenation and apnea by reproducing the methodology and results of previous clinical studies. Only four studies provided sufficient detail in their description of their methodology to allow accurate reproduction by using the NPS or provided a sufficiently detailed description of their subjects to allow accurate modelling. The results of the NPS recreation of the studies were within 13% of the values found clinically in all cases and were within 2% in the majority of cases. The four studies included healthy and morbidly obese patients, conscious and anesthetized patients, and included examination of the effect of denitrogenation and apnea on plasma pH and on lung and arterial oxygen and carbon dioxide tensions at various lung volumes. IMPLICATIONS: We used mathematical, physiological models to recreate the methods and subjects of four clinical studies investigating oxygenation and low oxygen levels during cessation of breathing. Our aim was to validate the models, allowing theoretical investigations into this area. The blindly recreated results closely matched the clinical studies, validating the models.

Apnea↗

Factors determining the onset and course of hypoxemia during apnea: an investigation using physiological modelling.

UNLABELLED: We used the Nottingham Physiology Simulator to examine the onset and course of hypoxemia during apnea after pulmonary denitrogenation. The following factors, as possible determinants of the hypoxemia profile, were varied to examine their effect: functional residual capacity, oxygen consumption, respiratory quotient, hemoglobin concentration, ventilatory minute volume, duration of denitrogenation, pulmonary venous admixture, and state of the airway (closed versus open). Airway obstruction significantly reduced the time to 50% oxyhemoglobin saturation (8 vs 11 min). Provision of 100% oxygen rather than air to the open, apneic patient model greatly prolonged time to 50% oxyhemoglobin saturation (66 vs 11 min). Hemoglobin concentration, venous admixture, and respiratory quotient had small, insignificant effects on the time to desaturation. Reduced functional residual capacity, short duration of denitrogenation, hypoventilation, and increased oxygen consumption significantly shortened the time to 50% oxyhemoglobin saturation during apnea. IMPLICATIONS: Reduction in oxygen levels during cessation of breathing is dangerous and common in anesthetic practice. We used validated, mathematical, physiological models to reveal the impact of physiological factors on the deterioration of oxygen levels. This study could not be performed on patients and reveals important information.

Apnea↗

Cerebral hemodynamic response to the introduction of desflurane: A comparison with sevoflurane.

UNLABELLED: Rapid increases in the inspired concentration of desflurane cause transient increases in heart rate and blood pressure. Desflurane also impairs cerebral autoregulation at clinical concentrations. Sevoflurane does not share these hemodynamic side effects. We compared the cerebral and systemic hemodynamic responses to the introduction of desflurane or sevoflurane after the induction of anesthesia with propofol. Twenty healthy adult patients scheduled for nonneurological surgery were recruited. After the induction of anesthesia with propofol, either desflurane or sevoflurane (n = 10 per group) was introduced at 7.2% or 2.2%, respectively, and increased to 10.8% or 3.3%, respectively, 2 min later. Middle cerebral artery blood flow velocity was measured continuously by using a 2-MHz transcranial Doppler ultrasound probe. Heart rate and blood pressure were recorded at 1-min intervals during the 12-min study period. Those patients receiving desflurane had significantly greater middle cerebral artery blood flow velocities, heart rates, and blood pressures than those receiving sevoflurane (P < 0.01). IMPLICATIONS: The introduction of desflurane after the induction of anesthesia leads to significant disturbances in cerebral and systemic hemodynamics suggesting loss of cerebral autoregulation and cerebral hyperemia. This may have implications for patients undergoing anesthesia for intracranial surgery.

Adult↗

Predicting patients' responses to changes in mechanical ventilation: a comparison between physicians and a physiological simulator.

We compared the accuracy and reliability of a validated, physiological simulator and six intensive care specialists in predicting changes in arterial oxygen tension (PaO(2)), arterial carbon dioxide tension (PaCO(2)) and pH following adjustment of mechanical ventilation. Twenty-five data sets were collected before and after routine alterations in ventilator settings. Fractional inspired oxygen was adjusted in all patients and minute volume was adjusted in 13 patients. The simulator was more accurate and consistent than all the physicians in predicting the magnitude of PaO(2) and pH change. The simulator had a larger bias in estimating the magnitude of change of PaCO(2) than four of the physicians, but was more consistent than all but one of the physicians. The simulator may prove to be a useful tool in the management of mechanical ventilation. Incorporation into mechanical ventilators in a passive predictive role or an active 'closed-loop' ventilation management system are potential roles for physiological simulation.

Blood Gas Analysis↗