Search PubMed⌕ Search

Biomedical subjects

J G Fujimoto

Publications and source records attributed to J G Fujimoto.

At least 73 records · Page 4Linked to original sources

Characterization of epiretinal membranes using optical coherence tomography.

OBJECTIVE: To evaluate optical coherence tomography (OCT), a novel noncontact and noninvasive imaging technique, for the diagnosis and quantitative characterization of epiretinal membranes. METHODS: Optical coherence tomography is similar to an ultrasound B-scan, except that light rather than sound is used, which enables higher resolution. Over a 2-year period, OCT was used to examine 186 eyes of 160 patients who had a diagnosis of an epiretinal membrane. Optical coherence tomograms were correlated with visual acuity, slit-lamp biomicroscopy, fluorescein angiography, and funds photography. RESULTS: Based on OCT, the epiretinal membrane was clearly separated from the retina with focal points of attachment in 49 eyes and globally adherent (no observed separation) in 125 eyes. Globally adherent membranes were associated with the following features: macular pseudohole (32 eyes), a difference in optical reflectivity between the membrane and retina (65 eyes), and/or a visible membrane tuft or edge (92 eyes). The membrane was undetectable on OCT in 12 eyes. The membrane thickness (mean +/- standard deviation) was 61 +/- 28 microns in the 169 eyes in which the thickness could be measured with OCT. Mean central macular thickness measured with OCT correlated with visual acuity (R2 = 0.73). CONCLUSION: Optical coherence tomography was able to provide a structural assessment of the macula that was useful in the preoperative and postoperative evaluation of epiretinal membrane surgery. Quantitative measurements and the assessment of membrane adherence with OCT may be useful in characterizing the surgical prognosis of eyes with an epiretinal membrane.

Aged↗

Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography.

PURPOSE: Optical coherence tomography (OCT) is a new technology that uses near-infrared light in an interferometer to produce approximately 10-microns resolution cross-sectional images of the tissue of interest. The authors performed repeated quantitative assessment of nerve fiber layer thickness in individuals with normal and glaucomatous eyes, and they evaluated the reproducibility of these measurements. METHODS: The authors studied 21 eyes of 21 subjects by OCT. Each subject underwent five repetitions of a series of scans on five separate occasions within a 1-month period. Each series consisted of three circular scans around the optic nerve head (diameters, 2.9, 3.4, and 4.5 mm). Each series was performed separately using internal (fixation with same eye being studied) and external (fixation with contralateral eye) fixation techniques. The eye studied and the sequence of testing were assigned randomly. RESULTS: Internal fixation (IF), in general, provides a slightly higher degree of reproducibility than external fixation (EF). Reproducibility was better in a given eye on a given visit than from visit to visit. Reproducibility as measured by intraclass correlation coefficients were as follows: circle diameter (CD), 2.9 mm, 0.51/0.57 (normal/glaucoma) (IF), 0.43/0.54 (EF); CD, 3.4 mm, 0.56/0.52 (IF), 0.43/0.61 (EF); CD, 4.5 mm, 0.53/0.43 (IF), 0.42/0.49 (EF). CONCLUSIONS: Nerve fiber layer thickness can be reproducibly measured using OCT. Internal is superior to external fixation; each circle diameter tested provides adequate reproducibility.

Aged↗

Optical coherence tomography of age-related macular degeneration and choroidal neovascularization.

OBJECTIVE: The authors used optical coherence tomography (OCT), a new technique for cross-sectional imaging of the retina, to morphologically study eyes with nonexudative and exudative age-related macular degeneration (AMD). In patients with untreated exudative AMD, OCT was compared with fluorescein angiography in the identification and classification of choroidal neovascularization (CNV). METHODS: Optical coherence tomography imaging is analogous to ultrasound, except that the use of light rather than sound enables higher longitudinal resolution with a noncontact and noninvasive measurement. Optical coherence tomography was performed on 391 patients with the clinical diagnosis of AMD and was compared with conventional clinical examination to establish the cross-sectional morphology of different lesions and to develop a classification scheme for CNV. Optical coherence tomograms and fluorescein angiograms then were reviewed and correlated independently in 90 eyes of 86 patients who had exudative AMD without previous laser treatment. RESULTS: Pigmentary changes, soft drusen, and detachments of the neurosensory retina and retinal pigment epithelium all had distinct presentations on OCT. Subretinal and intraretinal fluid caused changes in retinal thickness or elevation that could be quantified directly from the images. Choroidal neovascularization was evident in the tomograms as a thickening and fragmentation of a reflective layer, which corresponded to the retinal pigment epithelium and choriocapillaris. Changes in the reflection from this layer were observed during the progression of neovascularization, and after laser photocoagulation treatment. Classic CNV consistently presented with well-defined boundaries on OCT, whereas occult CNV had a variable cross-sectional appearance. CONCLUSIONS: Optical coherence tomography was useful in quantitatively evaluating subretinal and intraretinal fluid, assessing possible subfoveal involvement of neovascularization, and in monitoring CNV before and after laser photocoagulation. Optical coherence tomography was unable to detect CNV beneath serous pigment epithelial detachments. Optical coherence tomography may have potential in accurately defining the boundaries in a subset of angiographically occult CNV.

Adult↗

Imaging developing neural morphology using optical coherence tomography.

Imaging technologies offer numerous possibilities to investigate the processes involved in neural development. The optical coherence tomography (OCT) technology is analogous to ultrasound backscatter microscopy except reflections of light are detected rather than sound. The OCT technology combines high-resolution in vivo imaging in a diode-based benchtop instrument capable of micron-scale resolution in transparent and non-transparent biological specimens. In this paper, we examine the potential of using OCT for the investigation of developing neural morphology. To demonstrate the capabilities of this technique in assessing neural development, we have chosen to image early normal and abnormal neural morphology in a common developmental biology model, Xenopus laevis. In vivo images clearly identify gross and subtle differences in neural structure and may offer an alternative to the costly and time-consuming process of repeated histological preparation for neural developmental studies. Because imaging can be performed rapidly and repeatedly, the morphological changes of single specimens can be followed throughout development. To illustrate the future potential of this technique, a state-of-the-art Cr4+:forsterite modelocked laser is used as a broad bandwidth light source to image individual cells in a developing specimen.

Animals↗

Optical coherence tomography of the human retina.

OBJECTIVE: To demonstrate optical coherence tomography for high-resolution, noninvasive imaging of the human retina. Optical coherence tomography is a new imaging technique analogous to ultrasound B scan that can provide cross-sectional images of the retina with micrometer-scale resolution. DESIGN: Survey optical coherence tomographic examination of the retina, including the macula and optic nerve head in normal human subjects. SETTING: Research laboratory. PARTICIPANTS: Convenience sample of normal human subjects. MAIN OUTCOME MEASURES: Correlation of optical coherence retinal tomographs with known normal retinal anatomy. RESULTS: Optical coherence tomographs can discriminate the cross-sectional morphologic features of the fovea and optic disc, the layered structure of the retina, and normal anatomic variations in retinal and retinal nerve fiber layer thicknesses with 10-microns depth resolution. CONCLUSION: Optical coherence tomography is a potentially useful technique for high depth resolution, cross-sectional examination of the fundus.

Fovea Centralis↗

Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography.

PURPOSE: Quantitative assessment of nerve fiber layer (NFL) thickness in normal and glaucomatous eyes, and correlation with conventional measurements of the optic nerve structure and function. METHODS: We studied 59 eyes of 33 subjects by conventional ophthalmologic physical examination, Humphrey 24-2 visual fields, stereoscopic optic nerve head photography, and optical coherence tomography. RESULTS: Nerve fiber layer thickness as measured by optical coherence tomography demonstrated a high degree of correlation with functional status of the optic nerve, as measured by visual field examination (P = .0001). Neither cupping of the optic nerve nor neuroretinal rim area were as strongly associated with visual field loss as was NFL thickness (P = .17 and P = .21, respectively). Cupping correlated with NFL thickness only when the cup was small (cup-to-diameter ratio, 0.1 to 0.3) or large (cup-to-diameter ratio, 0.8 to 1.0) (P = .006); there was no correlation between cupping and NFL thickness otherwise. Nerve fiber layer, especially in the inferior quadrant, was significantly thinner in glaucomatous eyes than in normal eyes (P = .04). Finally, we found a decrease in NFL thickness with aging, even when controlling for factors associated with the diagnosis of glaucoma (P = .03). CONCLUSIONS: Nerve fiber layer thickness can be measured using optical coherence tomography. These measurements provide good structural and functional correlation with known parameters.

Female↗

Quantitative assessment of macular edema with optical coherence tomography.

OBJECTIVE: To evaluate optical coherence tomography, a new technique for high-resolution cross-sectional imaging of the retina, for quantitative assessment of retinal thickness in patients with macular edema. DESIGN: Survey examination with optical coherence tomography of patients with macular edema. SETTING: Referral eye center. PATIENTS: Forty-nine patients with the clinical diagnosis of diabetes or diabetic retinopathy and 25 patients with macular edema secondary to retinal vein occlusion, uveitis, epiretinal membrane formation, or cataract extraction. MAIN OUTCOME MEASURES: Correlation of optical coherence tomograms with slit-lamp biomicroscopy, fluorescein angiography, and visual acuity. RESULTS: Optical coherence tomograms of cystoid macular edema closely corresponded to known histopathologic characteristics. Quantitative measurement of retinal thickness is possible because of the well-defined boundaries in optical reflectivity at the inner and outer margins of the neurosensory retina. Serial optical coherence tomographic examinations allowed tracking of both the longitudinal progression of macular thickening and the resolution of macular edema after laser photocoagulation. In patients with diabetic retinopathy, measurements of central macular thickness with optical coherence tomography correlated with visual acuity, and optical coherence tomography was more sensitive than slit-lamp biomicroscopy to small changes in retinal thickness. CONCLUSIONS: Optical coherence tomography appears useful for objectively monitoring retinal thickness with high resolution in patients with macular edema. It may eventually prove to be a sensitive diagnostic test for the early detection of macular thickening in patients with diabetic retinopathy.

Adult↗

Optical coherence tomography of central serous chorioretinopathy.

PURPOSE: To assess the potential of a new imaging technique, optical coherence tomography, for the diagnosis and monitoring of central serous chorioretinopathy. Optical coherence tomography is a novel noninvasive, noncontact imaging modality that produces high longitudinal resolution, cross-sectional tomographs of ocular tissue. METHODS: Optical coherence tomography is analogous to ultrasound, except that it uses light rather than sound to obtain higher image resolution in the retina. Cross-sectional tomographs of optical reflectivity within the retina are produced with longitudinal resolution of 10 microns. Optical coherence tomography was used to examine 16 patients at a referral eye center whose initial examination disclosed the clinical diagnosis of central serous chorioretinopathy. The optical coherence tomography results were correlated with slit-lamp biomicroscopy, fundus photography, and fluorescein angiography. RESULTS: The cross-sectional view produced by optical coherence tomography was effective in objectively quantifying the amount of serous retinal detachment in the disease. Optical coherence tomography disclosed detachments that were undetected by slit-lamp biomicroscopy. Longitudinal measurements with optical coherence tomography were successfully able to track the resolution of subretinal fluid accumulation. CONCLUSION: Optical coherence tomography is potentially useful as a new, noninvasive diagnostic technique for quantitative examination of patients with central serous chorioretinopathy and objectively monitoring the clinical course of the serous retinal detachment in this disease.

Adult↗

Optical coherence tomography of macular holes.

PURPOSE: To assess the potential of a new diagnostic technique called optical coherence tomography (OCT) for diagnosing and monitoring macular holes. This technique is a novel noninvasive, noncontact imaging modality that produces high longitudinal resolution (10-micron) cross-sectional tomographs of ocular tissue. METHODS: Optical coherence tomography is analogous to ultrasound except that optical rather than acoustic reflectivity is measured. Cross-sectional tomographs of the retina profiling optical reflectivity in a thin, optical slice of tissue are obtained with a longitudinal resolution of 10 microns. Optical coherence tomography was used to examine 49 patients with the clinical diagnosis of idiopathic full-thickness macular hole, impending macular hole, epimacular membrane with macular pseudohole, or partial-thickness hole. The resulting OCTs were correlated with contact lens and slit-lamp biomicroscopy, fundus photography, and fluorescein angiography. RESULTS: The cross-sectional view produced by OCT was effective in distinguishing full-thickness macular holes from partial-thickness holes, macular pseudoholes, and cysts. Optical coherence tomography was successful in staging macular holes and provided a quantitative measure of hole diameter and the amount of surrounding macular edema. Optical coherence tomography also was used to evaluate the vitreoretinal interface in patients' fellow eyes and was able to detect small separations of the posterior hyaloid from the retina. CONCLUSION: Optical coherence tomography appears potentially useful as a new, noninvasive, diagnostic technique for visualizing and quantitatively characterizing macular holes and assessing fellow eyes of patients with a macular hole. The tomographic information provided by OCT eventually may lead to a better understanding of the pathogenesis of macular hole formation.

Adult↗

Imaging of macular diseases with optical coherence tomography.

BACKGROUND/PURPOSE: To assess the potential of a new diagnostic technique called optical coherence tomography for imaging macular disease. Optical coherence tomography is a novel noninvasive, noncontact imaging modality which produces high depth resolution (10 microns) cross-sectional tomographs of ocular tissue. It is analogous to ultrasound, except that optical rather than acoustic reflectivity is measured. METHODS: Optical coherence tomography images of the macula were obtained in 51 eyes of 44 patients with selected macular diseases. Imaging is performed in a manner compatible with slit-lamp indirect biomicroscopy so that high-resolution optical tomography may be accomplished simultaneously with normal ophthalmic examination. The time-of-flight delay of light backscattered from different layers in the retina is determined using low-coherence interferometry. Cross-sectional tomographs of the retina profiling optical reflectivity versus distance into the tissue are obtained in 2.5 seconds and with a longitudinal resolution of 10 microns. RESULTS: Correlation of fundus examination and fluorescein angiography with optical coherence tomography tomographs was demonstrated in 12 eyes with the following pathologies: full- and partial-thickness macular hole, epiretinal membrane, macular edema, intraretinal exudate, idiopathic central serous chorioretinopathy, and detachments of the pigment epithelium and neurosensory retina. CONCLUSION: Optical coherence tomography is potentially a powerful tool for detecting and monitoring a variety of macular diseases, including macular edema, macular holes, and detachments of the neurosensory retina and pigment epithelium.

Adult↗

Optical biopsy and imaging using optical coherence tomography.

Optical coherence tomography is a new imaging technique that can perform high-resolution, micrometre-scale, cross-sectional imaging in biological systems. The technology has been developed, and reduced to, preliminary clinical practice in ophthalmology. The challenging problem that OCT may address is the development of 'optical biopsy' techniques. These techniques can provide diagnostic imaging of tissue morphology without the need for excision of specimens. Many investigations remain to identify optimal areas for clinical application, and additional engineering must be done to integrate vertically the technology and to reduce it to clinical practice. Nevertheless, preliminary studies indicate the feasibility of developing this technology for a wide range of clinical and research diagnostic imaging applications. The ability to non-excisionally evaluate tissue morphology using a catheter or an endoscope could have a significant impact on the diagnosis and management of a wide range of diseases.

Arteries↗

Optical coherence tomography: a new tool for glaucoma diagnosis.

Optical coherence tomography (OCT) is a novel technique that allows cross-sectional imaging of the anterior and posterior eye. OCT has a resolution of approximately 10 microns, with extremely high sensitivity (approximately 10(-10) of incident light). OCT is analogous to computed tomography, which uses x-rays, magnetic resonance imaging, which uses spin resonance, or B-scan ultrasound, which uses sound waves, but OCT uses only light to derive its image. OCT is a noncontact, noninvasive system by which retinal substructure may be analyzed in vivo. OCT is useful in the evaluation of retinal pathologies and glaucoma. In retinal disease, entities such as macular holes, macular edema, central serous chorioretinopathy, retinal vascular occlusion and other factors have been examined. Separation between the posterior vitreous and retina, or lack thereof, are seen and quantitated. In glaucoma, retinal nerve fiber layer (NFL) thickness is measured at standardized locations around the optic nerve head. A circular scan produces a cylindrical cross-section of the retina, from which the NFL can be analyzed. In addition, radial scans through the optic nerve head are used to evaluate cupping and juxtapapillary NFL thickness. OCT, a new imaging technology by which the anterior and posterior segment are seen in cross-section, may permit the early diagnosis of glaucoma, and the early detection of glaucomatous progression.

Anterior Eye Segment↗

Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography.

OBJECTIVE: To demonstrate a new diagnostic technique, optical coherence tomography, for high-resolution cross-sectional imaging of structures in the anterior segment of the human eye in vivo. Optical coherence tomography is a new, noninvasive, noncontact optical imaging modality that has spatial resolution superior to that of conventional clinical ultrasonography (< 20 microns) and high sensitivity (dynamic range, > 90 dB). DESIGN: Survey of intraocular structure and dimension measurements. SETTING: Laboratory. PATIENTS: Convenience sample. MAIN OUTCOME MEASURES: Correlation with range of accepted normal intraocular structure profiles and dimensions. RESULTS: Direct in vivo measurements with micrometer-scale resolution were performed of corneal thickness and surface profile (including visualization of the corneal epithelium), anterior chamber depth and angle, and iris thickness and surface profile. Dense nuclear cataracts were successfully imaged through their full thickness in a cold cataract model in calf eyes in vitro. CONCLUSIONS: Optical coherence tomography has potential as a diagnostic tool for applications in noncontact biometry, anterior chamber angle assessment, identification and monitoring of intraocular masses and tumors, and elucidation of abnormalities of the cornea, iris, and crystalline lens.

Anterior Chamber↗

Intraocular microsurgery with a picosecond Nd:YAG laser.

We investigated the use of picosecond Nd:YAG laser pulses for intraocular microsurgery. With a pulse duration of 100 picoseconds, only 70 microJ of pulse energy is required to consistently produce optical breakdown in the deep vitreous. This pulse energy is nearly two orders of magnitude less than the typical pulse energies used in conventional (nanosecond) photodisruptors. The reduced pulse energy results in a smaller zone of tissue damage, an important consideration when operating close to the retina or other sensitive ocular structures. Efficient cutting action is achieved by applying multiple pulses at a moderately high repetition rate of 50-200 Hz. An in vitro model was developed to assess axial confinement of picosecond photodisruption. In vivo vitreous membrane surgery was performed in experimental rabbit eyes to demonstrate a potential clinical application of picosecond laser-induced optical breakdown.

3T3 Cells↗

[Spatial confinement of intraocular picoseconds-photodisruption effects].

Laser photodisruption is a routinely performed clinical procedure in intraocular microsurgery of post-cataract membranes, anterior synechies and iridectomies. Damage ranges of several millimeters in diameter, however, limit the use of nanosecond photodisruption close to delicate structures, e.g., in the posterior vitreous. Multiple ps-laser pulses of about 100 microJ pulse energy were used to produce disruptive effects in the anterior lens capsule in rabbit eyes in vivo. Ophthalmoscopical and morphological investigations of these effects were compared with those of minimal ns-disruptions. The direct tissue separation effects as well as the collateral damage zones are about one order of magnitude smaller if ps-laser pulses are used. Minimal sizes of disruptive effects are about 50 microns to 150 microns and 500 microns to 1000 microns for ps- and ns-pulses, respectively. The substantial improvement of spatial confinement of ps-photodisruption enables increased precision of intraocular laser microsurgery and opens up new areas of clinical application in structures like the cornea, anterior chamber angle, and crystalline lens.

Animals↗

Micron-resolution ranging of cornea anterior chamber by optical reflectometry.

Noncontact, high resolution measurements of anterior eye structures using optical coherence domain reflectometry are described. Distances between intraocular structures are measured by directing a beam of short coherence length light onto the eye and performing an interferometric measurement on the optical group delay of reflected signals. Measurements of corneal thickness, corneal excision depth, and anterior chamber depth are demonstrated in vitro, and the location of tissue boundaries is resolved to within +/- 2 microns. The full-width-half-maximum longitudinal resolution is 10 microns. Sensitivities to reflected signals as small as 10(-10) of the incident power are achieved by heterodyne detection.

Animals↗

Comparative studies of femtosecond to microsecond laser pulses on selective pigmented cell injury in skin.

Threshold radiant exposures for grossly apparent immediate whitening and ultrastructural alterations of melanosomes in black guinea pig skin were determined for a series of red visible laser pulses ranging from 4 x 10(-4) to 6.5 x 10(-14) s. Threshold exposures for melanosomal injury were found to be independent of pulsewidth when the pulsewidths were below the estimated thermal relaxation time of melanosomes. Threshold radiant exposures for melanosomal injury were found to increase when the pulsewidths were approximately equal to or above the thermal relaxation time of melanosomes. At longer pulse durations, fracturing of melanosomes was not observed despite the longer exposures necessary for injury. Instead, perimelanosomal vacuoles were noted. These findings are consistent with the theory of selective photothermolysis and provide evidence for the thermal initiation of melanosomal disruption.

Animals↗