Search PubMed⌕ Search

Biomedical subjects

J Fisher

Publications and source records attributed to J Fisher.

At least 181 records · Page 10Linked to original sources

Wear of ultra-high molecular weight polyethylene against damaged and undamaged stainless steel and diamond-like carbon-coated counterfaces.

The wear of ultra-high molecular weight polyethylene (UHMWPE) in artificial joints and the resulting wear debris-induced osteolysis remains a major clinical concern in the orthopaedic sector. Third-body damage of metallic femoral heads is often cited as a cause of accelerated polyethylene wear, and the use of ceramic femoral heads in the hip is gaining increasing favour. In the knee prostheses and for smaller diameter femoral heads, the application of hard surface coatings, such as diamond-like carbon, is receiving considerable attention. However, to date, there has been little or no investigation of the tribology of these coatings in simulated biological environments. In this study, diamond-like carbon (DLC) has been compared to stainless steel in its undamaged form and following simulated third-body damage. The wear of UHMWPE was found to be similar when sliding against undamaged DLC and stainless steel counterfaces. DLC was found to be much more damage resistant than DLC. Under test conditions that simulate third-body damage to the femoral head, the wear of UHMWPE was seven times lower against DLC than against stainless steel (P < 0.05). The study shows DLC has considerable potential as a femoral bearing surface in artificial joints.

Journal Article↗

Non-disjunction of chromosome 18.

A sample of 100 trisomy 18 conceptuses analysed separately and together with a published sample of 61 conceptuses confirms that an error in maternal meiosis II (MII) is the most frequent cause of non-disjunction for chromosome 18. This is unlike all other human trisomies that have been studied, which show a higher frequency in maternal meiosis I (MI). Maternal MI trisomy 18 shows a low frequency of recombination in proximal p and medial q, but not the reduction in proximal q observed in chromosome 21 MI non-disjunction. Maternal MII non-disjunction does not fit the entanglement model that predicts increased recombination, especially near the centromere. Whereas recent data on MII trisomy 21 show the predicted increase in recombination proximally, maternal MII trisomy 18 has non-significantly reduced recombination. Therefore, chromosome-specific factors must complicate the simple model of susceptible chiasma distributions interacting with age-dependent deterioration of the meiotic mechanism. For chromosome 18, 30% of tetrads are nullichiasmate in maternal MI non-disjunction, but nullichiasmates are not observed in maternal MII non-disjunction. Chiasma distributions from normal chromosome 18 meioses provide no evidence for normal disjunction from nullichiasmate tetrads. We extend this study to examine the remaining autosomes and find no evidence for normal disjunction from nullichiasmate tetrads generally.

Age Factors↗

Permeation of human ovarian tissue with cryoprotective agents in preparation for cryopreservation.

The recent improvements in the treatment of cancer by chemo- and radiotherapy have led to a significant increase in the survival rates of patients with malignant disease, but at the expense of distressing side effects. One major problem, especially for younger patients, is that aggressive therapy destroys a significant proportion of the follicular population, which can result in either temporary or permanent infertility. Freeze-banking pieces of ovarian cortex prior to treatment is one strategy for preserving fecundity. When the patient is in remission, fertility could, theoretically, be restored by autografting the thawed tissue at the orthotopic site or by growing isolated follicles to maturity in vitro. Recent studies have found good follicular survival in frozen-thawed human ovarian tissue but to optimize the process an effective cryopreservation method needs to be developed. An essential part of such a technique is to permeate the tissue with a cryoprotectant to minimize ice formation and the extent of this equilibration is an important determinant of post-thaw cellular survival. In the current study, we have investigated the diffusion of four cryoprotective agents into human tissue at both 4 degrees C and 37 degrees C. We have also studied the effect of adding different concentrations of the non penetrating cryoprotective agent, sucrose, to the freezing media using the release of lactate dehydrogenase as a measure of its protective effect. At 4 degrees C propylene glycol and glycerol penetrated the tissue significantly slower than either ethylene glycol or dimethyl sulphoxide. At the higher temperature of 37 degrees C all four cryoprotectants penetrated at a faster rate, however concern about enhanced toxicity prevents the use of these conditions in practice. Thus, the results suggest that the best method of preparing tissue for freezing is exposure for 30 min to 1.5 M solutions of ethylene glycol or dimethyl sulphoxide at 4 degrees C; this achieved a mean tissue concentration that was almost 80% that of the bathing solution. We also report that the addition of low concentrations of sucrose to the freezing medium does not have a significant protective effect against freezing injury.

Adult↗

Mechanical performance of clinically available, neonatal, high-frequency, oscillatory-type ventilators.

OBJECTIVE: To perform a functional evaluation of five different high-frequency, oscillatory-type ventilators that are currently being marketed for neonatal high-frequency oscillation. DESIGN: Observational animal study. SETTING: Laboratory. SUBJECTS: New Zealand White male rabbits. INTERVENTIONS: Oscillator waveforms and delivered volumes were measured plethysmographically for the following ventilators: the SensorMedics 3100 A; the Dräger Baby Log 8000; the Metran Humming V; the Infant Star; and the Infant Star 950. The independent variables which were adjusted included frequency (5 to 15 Hz), amplitude (25% to 100%), mean airway pressure (5 to 25 cm H2O) and lung injury. MEASUREMENTS AND MAIN RESULTS: At 15 Hz, the volume delivered at the 100% amplitude setting varied from 2.1 to 8.8 mL. Generally, the delivered volume decreased with increasing frequency, and with increased percentage of amplitude. Volume delivery was relatively unaffected by mean airway pressure but decreased with lung injury. Waveforms ranged from pure sinusoidal to a complex square wave. The handling of inspiration/expiration time ratios was ventilator specific. The SensorMedics inspiration/ expiration ratio is user selected over a range from 1:2.3 (30% inspiratory time) to 1:1 (50% inspiratory time) and once selected it is consistent over its entire range of operating frequencies. The Drager ratio is machine determined and varied from 1:2.5 at 5 Hz to 1:1 at 15 Hz. Inspiratory time of the Infant Star is machine set at 18 msecs such that the inspiration/expiration ratio is 1:10.1 at 5 Hz and 1:2.7 at 15 Hz. The Humming V has a fixed inspiration/expiration ratio of 1:1. The relationship of the mean airway pressure displayed on the ventilator to the alveolar occlusion pressure varied considerably among devices. The displayed mean pressure could either overestimate (SensorMedics at 33% inspiratory time or Infant Star), approximate (Humming V), or underestimate (Dräger) the mean lung distending pressure measured during a brief occlusion maneuver. CONCLUSIONS: The findings demonstrate large variations in machine performance. The ventilators also differed profoundly in complexity of operation and versatility as neonatal ventilators.

Animals↗

Tissue temperatures during ultrasound-assisted lipoplasty.

Removing excess subcutaneous fat with the assistance of ultrasonic energy has recently become a technique of interest in the United States after nearly a decade of use in Europe. There are a number of reported advantages of ultrasound-assisted lipoplasty over traditional liposuction, and there are also some theoretical concerns. Ultrasound-assisted lipoplasty involves the conversion of electrical energy to mechanical energy and transfer to the tissues through acoustic pressure waves, with the formation of heat as a by-product. Heat generated in this process dissipates through the body's own cooling mechanisms and conduction to the surrounding tissues, and it does not contribute to the clinical treatment of the adipose tissue. Reports of "burns" and ischemic skin injuries in the literature, and concerns for potential heat-related problems, prompted us to investigate whether significant temperature elevations occur in the clinical setting. Subcutaneous tissue temperature determinations during ultrasound-assisted lipoplasty were begun in February of 1996, and data were collected from 55 patients who had the procedure performed during a 6-month period. Intraoperatively, temperature measurements were made with a data-logging instrument and a needle microprobe inserted into the subcutaneous tissues. Temperatures were taken in the area of liposuction before the infusion of tumescent fluid, after tumescent fluid infusion, and at 5-minute intervals until the end of the procedure. The patient's core body temperature remained stable during the procedure within a narrow range (35.7 degrees C to 36.3 degrees C). There was a gradual increase in the temperature of the subcutaneous tissues over time during the application of ultrasonic energy; however, average subcutaneous temperatures remained below the core temperature (p < 0.05) at all time intervals. Room-temperature tumescent fluid further enhanced the thermal safety zone without lowering core body temperature. There were no temperature related complications in our study population and no untoward effects of performing temperature measurements. We conclude that there is no clinically significant elevation of subcutaneous temperatures during ultrasound-assisted lipoplasty. Reported ischemic skin complications are more likely the result of injury to the subdermal plexus rather than a temperature-induced thermal injury. Although heat is a natural by-product of the energy transfer involved in ultrasound-assisted lipoplasty, the risk of thermal injury is negligible when the procedure is performed by experienced operators. Complete understanding of the technique along with strict adherence to basic principles of flap vascularity will ensure safe and effective performance of ultrasound-assisted lipoplasty.

Adult↗

Nondisruptive, in vivo method for biomechanical characterization of linear incision wound healing: preliminary report.

Previous work on in vivo biomechanical characterization of soft tissues and wound healing has led to the development of a methodology for nondisruptive, in vivo biomechanical analysis of linear incision wounds. The purpose of this preliminary study was to define nondisruptive biomechanical parameters that characterize progressive healing and compare them with an in vivo disruptive parameter of ultimate pressure at failure (in vivo strength). Male Sprague-Dawley rats (n = 60), each weighing 250 to 300 gm, were anesthetized and underwent creation of paired full-thickness linear incision wounds. The rats were divided into three groups (n = 10/group per time period): control group, nothing applied to either wound; carrier group, bovine serum albumin applied to each wound; transforming growth factor-beta2 group, transforming growth factor-beta2 in bovine serum albumin applied to each wound. On postoperative days 5 and 10, rats from each group underwent in vivo biomechanical testing using the Dimensional Analysis System (Dimensional Analysis Systems, Inc., Nashville, Tenn.). This computer-driven device integrates a video camera and processor with a vacuum controller, valve, and transducer to provide measurements of tissue deformation (in millimeters) and negative pressure (mmHg) as a multiaxial stress (vacuum) is applied to a wound. On each rat, one incision was tested disruptively and the other incision was tested nondisruptively. Disruptive data were measured as ultimate pressure (mmHg) at failure, or the amount of pressure required to disrupt the wound. Nondisruptive data were measured for tissue stiffness (kiloPascals) during application of negative pressure (maximum, 80 mmHg). On postoperative day 5, wounds treated with transforming growth factor-beta2 had significantly increased in vivo wound strength compared with carrier wounds. The nondisruptive parameter of tissue stiffness was also significantly increased for the transforming growth factor-beta2 treated wounds, thus supporting the disruptive data. On postoperative day 10, there was no difference in mean wound strength or mean tissue stiffness among any of the groups. These preliminary data represent the first report of in vivo, nondisruptive biomechanical characterization of linear incision wounds. The results suggest that through in vivo measurements of tissue stiffness, differences can be detected between treatment groups. Because the healing wound may be characterized without the need for disruption, this methodology should allow for consecutive, in vivo biomechanical testing of wounds in future wound healing studies.

Animals↗

Analysis of contact mechanics for composite cushion knee joint replacements.

Recent research in the area of cushion form bearings for total joint replacements has primarily used thin, soft, elastomeric layers with similar elastic modulus to articular cartilage, bonded to rigid substrates. These are designed to promote the body's natural lubricants to separate the articulating surfaces and prevent wear. Applications to joint replacements have revealed that the abrupt change in stiffness between the soft layer and the rigid substrate and the relatively low strength of the interface resulted in high shear stresses and debonding of the soft layer from the substrate. The approach adopted in this study is to use components with a graded modulus or composite construction. The composite construction consists of a soft compliant layer of polyurethane and a second stiffer polyurethane layer thought to be rigid enough to mechanically interlock to a metallic tibial tray. In this composite structure the deformation of the more rigid polyurethane underlay may generally influence the stress distribution and deformation in the softer upper layer and at the interface between the two materials. A simple analysis technique is presented in the present study where the composite double layer was approximated as an equivalent modulus single layer. Single layer theory, which is readily available in the literature, can then be used to determine the contact parameters, including the maximum contact pressure and the contact radius, for the composite structure. By varying the layer thicknesses and material properties of both the soft surface layer and the stiffer structural support layer, the magnitudes and locations of stresses can be controlled. Results of a parametric stress analysis are presented to assist in the selection of the most appropriate composite layers for cushion knee designs. A 4 mm thick surface layer with an elastic modulus of 20 MPa and a 4 mm thick structural support layer with an elastic modulus of 1000 MPa were considered suitable for this application.

Biomechanical Phenomena↗

Prediction of plastic strains in ultra-high molecular weight polyethylene due to microscopic asperity interactions during sliding wear.

Studies of explanted femoral heads have shown that scratches caused by bone cement, bone or metallic particles are present on the rubbing surface. This damage has been cited as a cause of increased wear of ultra-high molecular weight polyethylene (UHMWPE) acetabular cups and it is known that the particulate wear debris produced leads to osteolysis. A series of explanted Charnley femoral heads have been surface characterized using a Talysurf 6 profilometer and found to have scratches with lip heights in the size range 0.1-3.25 microns with an average height of 1 micron giving an average aspect ratio (defined as height/half-width) of 0.1. These geometries were incorporated into a finite element model of a stainless steel asperity sliding over UHMWPE under conditions similar to those in an artificial hip system. It was found that as the aspect ratio of the asperity lip increased, the plastic strains both on and below the surface of the UHMWPE increased non-linearly, but that the magnitude of the strain was independent of the asperity height. The asperity aspect ratio was also found to affect the position of the maximum sub-surface strain, as the asperity aspect ratio was increased the maximum strain rose to the surface. The high plastic strains predicted offer an explanation for the highly elevated wear rates in scratched counterface tests and the aspect ratio of scratch lips is therefore a critical determinant of plastic strain.

Computer Simulation↗

Prediction of transient lubricating film thickness in knee prostheses with compliant layers.

The transient lubricating film thickness in knee prostheses using compliant layers has been predicted under simulated walking conditions based upon the elastohydrodynamic lubrication theory. Qualitative agreement has been found between the present theoretical predictions and the experimental measurements using an electric resistance technique reported earlier. It has been shown that the contact geometry plays an important role in the generation of fluid film lubrication in knee prostheses using compliant layers. The maximum lubricating film thickness is predicted for the maximized contact area of a transverse conjunction where the semi-minor contact radius lies in the direction of entraining. The additional advantage of the transverse contact conjunction is that the possibility of lubricant starvation due to small stroke length can be minimized. All these factors, together with the kinematic requirements in the natural knee joint, should be taken into consideration when designing artificial knee joint replacements.

Biocompatible Materials↗

Investigation into the effect of proteoglycan molecules on the tribological properties of cartilage joint tissues.

The aim of this research was to investigate the role of the hydrophilic properties of the proteoglycan molecules within the cartilage matrix, on the tribological properties of joint tissues in the mixed and boundary lubricating regime. Bovine articular cartilage, bovine meniscus and bovine cartilage that had been degraded to remove the chondroitin sulphate from its proteoglycans were studied in order to investigate differences in their friction and compression responses. The tissues were tested on a sliding friction rig under nominal contact stresses of 0.5 and 4 MPa. The compression tests were carried out under a 0.8 MPa contact stress. The compression tests showed the cartilage and meniscus deforming at the same rates, but the degraded cartilage deformed more quickly to reach its equilibrium position in a shorter period of time. The friction tests carried out at a constant load revealed the friction of the meniscus rising more rapidly with loading time than the cartilage. The degraded cartilage followed an almost identical curve as the untreated cartilage. Although the reduced proteoglycan content of the degraded cartilage substantially altered the biphasic compression response, it did not have an effect on the frictional properties of the tissue.

Animals↗

A two-dimensional model of cyclic strain accumulation in ultra-high molecular weight polyethylene knee replacements.

As new methods of sterilization of the ultra-high molecular weight polyethylene (UHMWPE) component in knee replacements are introduced, reported incidents of delamination will decrease. The prediction of plastic strain accumulation and associated failure mechanisms will then become more important in knee replacement design. The finite element analysis reported in this paper aims to advance the modelling of strain accumulation in UHMWPE over repeated gait cycles and seeks to determine the effects of the knee replacement design variables of geometry and kinematics. Material testing was performed under cyclic and creep conditions to generate the elastic, viscoplastic material model that has been used in this time-dependent analysis. Non-conforming geometries were found to accumulate plastic strains at higher rates than conforming geometries. The anatomical motion known as rollback initially produced lower strain rates, but predictions of the long-term response indicated that designs which allow rollback may produce higher strains than static designs after only about a week of loading for a knee replacement patient.

Biocompatible Materials↗

Quantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation.

Ultra-high-molecular-weight polyethylene (UHMWPE) components for total joint replacement generate wear particles which cause adverse biological tissue reactions leading to osteolysis and loosening. Sterilisation of UHMWPE components by gamma irradiation in air causes chain scissions which initiate a long-term oxidative process that degrades the chemical and mechanical properties of the polyethylene. Using a tri-pin-on-disc tribometer we studied the effect of ageing for ten years after gamma irradiation in air on the volumetric wear, particle size distribution and the number of particles produced by UHMWPE when sliding against a stainless-steel counterface. The aged and irradiated material produced six times more volumetric wear and 34 times more wear particles per unit load per unit sliding distance than non-sterilised UHMWPE. Our findings indicate that oxidative degradation of polyethylene after gamma irradiation in air with ageing produces more wear.

Air↗

Quantification of third-body damage and its effect on UHMWPE wear with different types of femoral head.

We examined stainless-steel, cobalt-chrome, titanium and alumina and zirconia ceramic femoral heads retrieved at revision surgery. All the heads had articulated against ultra-high-molecular-weight-polyethylene (UHMWPE) acetabular cups. We studied the simulation of third-body damage and the wear of UHMWPE against the various materials used for the heads. The surfaces of the retrieved heads were analysed using a two-dimensional contacting profilometer. Third-body damage was characterised by the mean height of the scratches above the mean line (Rpm). The alumina ceramic and zirconia ceramic retrieved heads were found to have significantly less damage. In laboratory studies the ceramics were also more resistant to simulated third-body damage than the metal alloys. We studied the wear of UHMWPE against the damaged counterfaces in simple configuration tests. The damaged ceramics produced less polyethylene wear than the damaged metal counterfaces. The wear factor of UHMWPE against the damaged materials was dependent on the amount of damage to the counterface (Rp). Our study has shown the benefit of using the harder and more damage-resistant ceramic materials for femoral heads.

Aluminum Oxide↗

Normative sexual behavior in children: a contemporary sample.

OBJECTIVE: Sexual behavior in children can cause uncertainty in the clinician because of the relationship between sexual abuse and sexual behavior. Consequently, it is important to understand normative childhood sexual behavior. DESIGN: Sexual behavior in 1114 2- to 12-year-old children was rated by primary female caregivers. These children were screened for the absence of sexual abuse. A 38-item scale assessing a broad range of sexual behavior (Child Sexual Behavior Inventory, Third Version) was administered along with the Child Behavior Checklist and a questionnaire assessing family stress, family sexuality, social maturity of the child, maternal attitudes regarding child sexuality, and hours in day care. RESULTS: Sexual behavior was related to the child's age, maternal education, family sexuality, family stress, family violence, and hours/week in day care. Frequencies of sexual behaviors for 2- to 5-, 6- to 9-, and 10- to 12-year-old boys and girls are presented. CONCLUSIONS: A broad range of sexual behaviors are exhibited by children who there is no reason to believe have been sexually abused. Their relative frequency is similar to two earlier studies, and this reinforces the validity of these results.

Age Factors↗

Interaction of gemcitabine with paclitaxel and cisplatin in human tumor cell lines.

We have used clonogenic survival assays and flow cytometry of human lung A549, breast MCF7 and pancreas adenocarcinoma P-SW cell lines to examine the effects of gemcitabine (2'-deoxy-2', 2'-difluorocytidine) in combination with cisplatin, paclitaxel or radiation. Additive cell killing was observed for all cell lines when they were treated with cisplatin for 1 h followed by varying concentrations of gemcitabine for 24 h. Likewise, additive cell killing was noted in all cell lines when treated with gemcitabine for 24 h followed by varying doses of radiation. When A549 cells were exposed to gemcitabine for 24 h followed by a 1 h exposure to cisplatin, synergistic effects were noted. Using the latter regimen, MCF7 cells demonstrated additive cell kill, while the P-SW cells showed a more complex relationship with additive killing below 50 nM gemcitabine and less than additive effect above 50 nM gemcitabine. All three cell lines were also tested with various gemcitabine/paclitaxel combinations. When gemcitabine and paclitaxel were incubated concurrently, gemcitabine antagonized the cell kill produced by paclitaxel. All cell lines showed less than additive killing when either gemcitabine incubation preceded the paclitaxel incubation or the paclitaxel incubation preceded the gemcitabine incubation. Our results show that gemcitabine acts as a radiation sensitizer to increase the effects of radiation. Likewise, we demonstrate that the only uniformly beneficial drug combination schedule in all three cell lines was when cisplatin incubation preceded gemcitabine incubation. The gemcitabine/paclitaxel combinations were much more disturbing with respect to potential clinical trials. Our results would caution any planned clinical trials combining paclitaxel with gemcitabine to be reconsidered because of the potential for less than additive and even antagonistic effects of the combination.

Antineoplastic Combined Chemotherapy Protocols↗

Ultrasound assisted lipoplasty--Part 1: An overview for nurses.

The use of ultrasound assisted lipoplasty (UAL) to assist in the removal of subcutaneous fat has been practiced in Europe for nearly a decade but has only recently been practiced in the United States. This article will discuss the UAL procedure, its history, regulatory issues, instrumentation and equipment needed, clinical protocol, case reports, complications, and future considerations.

Education, Nursing, Continuing↗