Recordings of eye movements for stimulus control during fMRI by means of electro-oculographic methods.

A method for monitoring eye movements in humans during functional MRI is presented. It is based on the acquisition of electro-oculographic (EOG) signals near one eye. EOG potentials were amplified and converted into an optical signal just outside the head coil. An optical fiber was used for signal transmission from inside the magnet bore to the control room. The EOG sensor was tested during EPI sequences at 1.5 Tesla without contamination of the MR signal. Some flow related artifacts on the EOG were observed inside the magnet, but no additional interactions from the MR sequence. An analysis of the latency, direction, and amplitude of the saccadic eye movements was possible.

Electrooculography↗

Structural and neurobehavioral delay in postnatal brain development of preterm infants.

Postnatal brain development of healthy prematurely born infants was assessed to study possible influence of premature birth and early extrauterine environment on structural, biochemical, and functional brain development. Myelination and differentiation of gray and white matter were studied by in vivo magnetic resonance (MR) imaging (MRI), changes in cerebral metabolism by 1HMR spectroscopy (MRS), and changes in early human neurobehavior by the assessment of preterm infant's behavior (APIB). The stage of intrauterine and extrauterine brain development in prematurely born infants at term was compared with the stage of mainly intrauterine brain development in a group of full-term infants. Eighteen preterm infants unremarkable with respect to neurologic and medical status were studied at approximately 2 wk of postnatal age [gestational age (GA) 1: 32.5 +/- 1.2 wk] and again at term (GA 2: 40.0 +/- 1.1 wk). For comparison a group of 13 full-term born infants (GA T: 40.6 +/- 2.1 wk) were studied by MR and six by APIB. When GA 2 to GA 1 was compared, significant maturational changes were found with MRI in gray and white matter and myelination, with 1H MRS in the concentration of N-acetylaspartate and with all scores of APIB. In preterm infants at term (GA 2) compared with full-term infants (GA T) significantly less gray and white matter differentiation and myelination was observed as well as significantly poorer performance in four neurobehavioral parameters (autonomic reactivity, motoric reactivity, state organization, attentional availability). We conclude that MRI and 1H MRS can be used to study postnatal brain development in preterm infants. Structural and biochemical maturation is accompanied by functional maturation as shown with the neurobehavior assessment. Preterm infants at term compared with full-term infants show a structural as well as a functional delay in brain development assessed at 40 wk of postconceptional age.

Age Factors↗

Evaluation of ultrafast phase-contrast imaging in the thoracic aorta.

PURPOSE: Two ultrafast phase-contrast (PC) data acquisition strategies, multishot echo-planar imaging (EPI)-PC and segmented k-space fast gradient-echo PC (FASTCARD-PC) were evaluated with regard to their measurement accuracy. MATERIALS AND METHOD: Flow measurements of the ascending and descending aorta were acquired in 10 healthy volunteers with an electrocardiogram (ECG)-triggered eight-shot EPI-PC sequence (TR/TE/flip 16/7.4/45 degrees, 32-ms flow-phase interval, 2 x 2 mm in plane resolution), and FASTCARD-PC (six k-lines per band, TR/TE/flip 11/6.1/45 degrees, 132-ms flow-phase interval, 2 x 1 mm in plane resolution). These were compared to flow-volume data acquired with conventional cine-PC (TR/TE/flip 24/7/45 degrees, 48-ms flow-phase interval, 2 x 1 mm in plane resolution). Using cine-PC as a gold standard, the measurement accuracy of FASTCARD-PC and EPI-PC were determined. RESULTS: Both EPI-PC and FASTCARD-PC significantly reduced data acquisition times compared to cine PC. EPI-PC flow measurements correlated well with aortic cine-PC flow-volume determinations (r = 0.98). Reflecting poorer temporal resolution, FASTCARD-PC measurements were less accurate (p < 0.05), evidenced by poor correlation with cine-PC data (r = 0.62). CONCLUSION: Ultrafast PC measurements are possible. In contrast to the segmented k-space PC technique, which is limited in temporal resolution, multishot EPI-PC provides high measurement accuracy in pulsatile vessles while keeping the image acquisition interval short enough for a comfortable breath-hold.

Adult↗

Synchronization device for electrocardiography-gated echo-planar imaging.

An electrocardiography (ECG) synchronization technique allowed triggering of 1.5-T echo-planar acquisitions of the heart, with high gradient slew rates. In 51 volunteers (37 men and 14 women, aged 21-48 years), the ECG signal was amplified, filtered, and converted into an optical signal directly above the heart and was transmitted optically outside the bore. Reliable and artifact-free ECG tracings were obtained in all cases, regardless of the gradient switching speed.

Adult↗

Electrocardiogram acquisition during MR examinations for patient monitoring and sequence triggering.

We have developed a method for measuring the electrocardiogram (ECG) continuously during MR examinations. In contrast to ECG acquisition by wires, our new method is to amplify and convert the ECG into an optical signal directly above the patient's heart. The optical signal is transmitted out of the magnet bore by optical fiber. The small and fixed dimensions of the ECG amplifier avoid interactions with the MR system because of shorter electrical structures and smaller enclosed areas. Tests of the proposed device in a 1.5 Tesla MR system show that continuous and reliable ECG monitoring and sequence triggering are possible.

Adult↗

Flow quantitation with echo-planar phase-contrast velocity mapping: in vitro and in vivo evaluation.

We present a multishot echo-planar imaging (EPI) phase-contrast implementation for flow quantitation. The measurement accuracy of this technique was evaluated in vitro and in vivo. A gated eight-shot EPI phase-contrast sequence (TR/TE = 16/7.4, 45 degrees flip angle), with a flow-phase interval of 32 msec and an in-plane resolution of 2 x 2 mm was initially evaluated in a pulsatile flow phantom. Subsequently, EPI phase-contrast flow measurements of the ascending and descending aorta, obtained in 10 volunteers, were compared with flow volume data acquired with a conventional cine phase-contrast sequence (TR/TE = 24/7, 45 degrees flip angle, 48-msec flow-phase interval, 2 x 1 mm in-plane resolution). Comparisons between flow measurements were made using data obtained with the flow probe and cine phase contrast as the standard of reference for in vitro and in vivo measurements, respectively. EPI phase-contrast sequences reduced data acquisition times tenfold compared with cine phase-contrast sequences. EPI phase-contrast flow measurements correlated well with phantom flow (r = .98, slope = 1.1) as well as with aortic cine phase-contrast flow volume determinations (r = .98). A 95% confidence interval of measurement differences between echo-planar and cine phase-contrast imaging, ranging from 2.0 to -1058 mL/min was computed. Ultrafast phase-contrast flow measurements are possible. Multishot EPI phase-contrast imaging provides high measurement accuracy in pulsatile vessels while keeping the image acquisition interval short enough to be accomplished in a comfortable breath-hold.

Adult↗