Search PubMed⌕ Search

Biomedical subjects

J F Reidy

Publications and source records attributed to J F Reidy.

At least 19 recordsLinked to original sources

Mid-term results for second-generation thoracic stent grafts.

BACKGROUND: Thoracic stent grafts offer an alternative to open surgery for thoracic aortic disease, but their long-term durability is unknown. This report includes mid-term follow-up for commercially available thoracic devices. METHODS: Data were collected prospectively for a series of endoluminal grafts used to treat thoracic aortic pathology. RESULTS: Between July 1997 and October 2002, 67 patients received thoracic stent grafts. Elective procedures incurred a 30-day mortality rate of 2 per cent (one of 42 patients) and urgent repair 16 per cent (four of 25). Paraplegia affected three (4 per cent) of 67 patients and three patients had a stroke. The median follow-up was 17 (range 2-64) months; four patients were lost. There were six late deaths, two from aneurysm rupture (rupture of a mycotic aneurysm at 5 months and stent migration at 28 months). Other device-related complications comprised three proximal endoleaks, one of which required open surgical correction with removal of the stent graft, and two distal endoleaks, which were successfully treated with distal extension cuffs. CONCLUSION: In the mid term, endoluminal repair of thoracic aortic pathology appears to be a safe alternative to open surgery, but continued surveillance is essential.

Adolescent↗

Results of urgent and emergency thoracic procedures treated by endoluminal repair.

INTRODUCTION: emergency surgery on the thoracic aorta is associated with a high mortality. Endovascular treatment for these patients may offer a realistic alternative to open surgery. METHOD: between 1997 and 2002 data was collected prospectively on all patients who underwent urgent or emergency endoluminal repair for thoracic aortic pathology. All patients had ruptured or were at risk of rupture, and had been assessed as high risk for open surgery. RESULTS: twenty-four patients required urgent/emergency stent grafts. The median age was 74 (range 17-90). Indications included: trauma (transection in 3 and traumatic dissection in 1), acute symptomatic type B dissection (4), symptomatic degenerative aneurysms (7), false aneurysms associated with infection (6), Takayasu's vasculitis causing rupture of the descending thoracic aorta (1), symptomatic aneurysm associated with chronic dissection (1) and a secondary aorto-oesophageal fistula (1). The 30-day survival was 83.3% (20/24) and the survival at 1 year was 70.8% (17/24). The median follow-up was 13.5 months (range 2-57). The complications included: transient paraplegia (1), non-disabling stroke (1), distal endoleak treated with an extension cuff (1) and a proximal endoleak (1) which required removal of the graft at open surgery. CONCLUSION: endoluminal repair of thoracic aortic disease requiring urgent/emergency treatment has encouraging results with low morbidity and mortality rates compared with open surgery. Long-term follow-up is required to assess the durability of the grafts.

Adolescent↗

Intraluminal biopsy of a superior vena cava mass.

A number of methods have been devised for the biopsy of intracaval tumour masses but all risk damage to the cava and tumour dissemination. We report on a case in which the tumour mass was almost entirely within the superior vena cava and describe an 'endoscopic' technique for biopsy.

Biopsy↗

Thoracic aortic stent grafts--early experience from two centres using commercially available devices.

OBJECTIVES: open surgical intervention for aneurysms of the distal arch and descending thoracic aorta is associated with high morbidity and mortality. Stent grafts offer an attractive alternative treatment for these aneurysms. The aim of this study was to assess the morbidity and mortality of endovascular treatment for these aneurysms with stent grafts. DESIGN, PATIENTS AND METHODS: a prospective observational study was performed of 37 consecutive patients treated from July 1997 to October 2000 (30 at Guy's and St. Thomas' and 7 at Sheffield). Indications included degenerative aneurysms (n=18), false aneurysm (5), acute dissection (4), aortic transection (4), aneurysm related to previous surgery for coarctation (3), chronic dissection (2) and traumatic dissection (1). Nineteen were performed as elective and 18 as non-elective procedures. RESULTS: three non-elective patients died in hospital (in-hospital and 30-day mortality 8%) and one suffered a stroke with spontaneous full recovery. No elective patient died. One patient with a persistent proximal endoleak required conversion to open repair at 6 weeks. Two patients with persistent flow into the sac at 24 h spontaneously thrombosed at subsequent 3 month follow-up. Two further patients developed new distal endoleaks at 3 months and required distal extension cuffs. One patient died at 28 months of aortic rupture. Serial CT scans had shown prolapse of the stent graft into the aneurysm sac and the patient died just before planned endovascular repair. No patient suffered paraplegia or renal failure. Intensive care facilities were only required for patients who needed them preoperatively. CONCLUSIONS: thoracic stent grafts can be performed with low morbidity and mortality. They offer a realistic alternative to open surgery. Long term follow up is required to assess their durability.

Aged↗

Repair of secondary aortoesophageal fistula by endoluminal stent-grafting.

PURPOSE: To describe a case of secondary aortoesophageal fistula that was treated with an endoluminal stent-graft. CASE REPORT: A 58-year-old woman presented with hematemesis and melena. In 1974 she had an interposition graft repair of an aortic transection sustained during a traffic accident. At the examination in 1998, angiography demonstrated a mechanical disruption of the proximal anastomosis forming an aortoesophageal fistula. A 28-mm x 3.75-cm AneuRx stent-graft was introduced via a right femoral arteriotomy and deployed across the defect. Follow-up CT scans at 18 months showed exclusion of the false aneurysm with no evidence of infection; the patient remains well at >2 years after stent-graft implantation. CONCLUSIONS: Endoluminal repair can be successful in achieving a satisfactory midterm outcome in cases of secondary aortoesophageal fistula.

Anastomosis, Surgical↗

A scoring system to predict the outcome of long femorodistal arterial bypass grafts to single calf or pedal vessels.

OBJECTIVES: The aim of this study was to develop a scoring system to predict the outcome of long femorocrural and femoropedal bypass grafts performed for critical limb ischaemia. SETTING: Teaching hospital. METHODS: An analysis of 109 consecutive femorodistal bypass grafts performed for critical lower limb ischaemia between June 1991 to December 1994. Factors shown to affect the outcome were: inflow, number of patent calf vessels, graft material, straight flow to the foot and patent pedal vessels. These variables were weighted according to their relative significance (multivariate Cox regression) and a scoring system (ranging from 0 to 10) was developed. RESULTS: Patients with a preoperative score of 0-4 (n = 35) showed a secondary patency of 36% at 1 month, 12% at 3 months and 0% at 10 months (Cum SE = 6.90/0.0). Secondary patency rates for the 46 patients with score 5-7 were 88.7% at 3 months, 56.3% at 12, and 45.1% at 2 and 3 years (Cum SE = 9.82), while the respective values for the 28 patients with score 8-10 were 92.7%, 88.5% and 81.7% (Cum SE = 8.08). The difference was highly significant (p = 0.000) in all tests of equality. In addition, the median total hospital cost was 12,600 Pounds for the group 0-4 compared with 8100 Pounds (group 5-7) and 4400 Pounds (group 8-10) (p = 0.0085). CONCLUSIONS: This preoperative scoring system appears to correlate well with the outcome of distal revascularisation to single calf or pedal vessels. If applied to patient selection, it could significantly reduce the total hospital cost per leg saved. A prospective testing of its predictive ability is needed and is in progress.

Amputation, Surgical↗

Transcatheter uterine artery embolisation to treat large uterine fibroids.

Bilateral uterine artery embolisation was performed to treat eight women with symptomatic large fibroids requiring treatment. Uterine volume was quantitatively assessed by magnetic resonance imaging. Both uterine arteries were occluded effectively in all women, and the procedure was well tolerated, with a 24-36 hour admission for pain relief. The level of pain experienced was variable, but well controlled. Some women experienced intermittent vaginal discharge and pain following the procedure. Improvement of symptoms occurred in six of the seven women and the eighth woman conceived. There were no significant complications. At three months four women had a uterine volume of < 350 cm3. Embolisation appears to be a good alternative to surgery, but longer follow up is required to evaluate the long term effects and to determine those patients for whom the procedure is suitable.

Adult↗

The concept of knee salvage: why does a failed femorocrural/pedal arterial bypass not affect the amputation level?

OBJECTIVES: There is continued controversy over whether a failed distal bypass influences the level of amputation. This issue is important as the number of arterial bypass grafts undertaken for critical ischaemia is increasing, followed by an increasing number of failed grafts. SETTING: Teaching hospital. STUDY DESIGN AND MATERIALS: A prospective analysis of 109 consecutive femorocrural/pedal bypass grafts performed between June 1991 and January 1995 on patients presenting with severe critical lower limb ischaemia (CLI) to a single vascular unit. A further 43 amputations for non-reconstructible distal disease were also analysed. CHIEF OUTCOME MEASURES: Mortality, amputation, rehabilitation, survival and knee salvage rates. The Kaplan-Meier method was used for comparison of factors associated with knee preservation. RESULTS: Primary amputees had a higher in-hospital mortality (18% vs. 10%) but similar 3 year survival rates (30%) compared with secondary amputees (36.6%). Patients with successful grafts showed a trend towards better survival (61.9% at 3 years) compared to amputees (38.6% at 42 months, p = 0.061). Below- to above-knee amputation ratio was similar in the two groups (0.85 in secondary vs. 0.95 in primary amputees). Factors significantly associated with knee salvage at 3 years were shown to be: the condition of the inflow (81.9% for good vs. 43.1% for impaired, p = 0.000) the state of the profunda femoris artery (good 93%, impaired 71%, occluded 37% p = 0.0001) and the graft material (vein 81.8% vs. PTFE 59.8%, p = 0.033). The presence of tissue loss (p = 0.0523) and secondary procedures (p = 0.0879) showed a trend to become significant. Multivariate and Cox regression analysis showed that the most important factors were the inflow (p = 0.001), the state of the profunda (p = 0.001), the graft material (p = 0.034) and previous revascularisation attempts (p = 0.019). CONCLUSIONS: The factors which determine knee loss are a compromised inflow state, the presence of an inadequate profunda femoris, previous revascularisation attempts and the use of synthetic graft material. Most of these factors (with the exception of infection related to revascularisation) are present before reconstructive arterial surgery is performed and this study shows that failure of a distal graft does not affect the final amputation level.

Aged↗

Percutaneous angioplasty for infrainguinal graft-related stenoses.

OBJECTIVE: To assess the success of percutaneous transluminal angioplasty (PTA) in treating infrainguinal graft-related stenoses. DESIGN: Retrospective analysis of stenoses undergoing PTA over 6 years. MATERIALS: Fifty-seven stenoses in 42 grafts. METHODS: Site, length and type of stenoses recorded. Follow-up till discharge, graft occlusion or death. RESULTS: PTA was successful in 48/57 stenoses in 36 grafts (G), with a poor result in seven. Further PTA was required in seven stenoses (7 G). One graft occluded at PTA and one stenosis was inaccessible. Overall graft (G) patency (median 13 months) was 82% (1 year patency 84%). Of 48 successful PTAs (37 G), 36 remained patent (28 G), eight (4 G) occluded and four were lost to follow-up (4 G). Fourteen of thirty-six stenoses which remained patent required further intervention (seven PTA, six jump grafts, one vein patch). The four occlusions were associated with small veins (two), multiple stenoses (one) and a PTFE graft which occluded 10 days following PTA. Of the seven PTAs with a poor angiographic result, five remained patent, three after further intervention. CONCLUSION: PTA is the best treatment for localised stenoses. Stenoses > 2 cm or multiple (three or more) stenoses are best treated surgically. Follow-up is essential, as 20% require further intervention.

Angiography↗