Search PubMed⌕ Search

Biomedical subjects

J F Nunn

Publications and source records attributed to J F Nunn.

At least 37 records · Page 2Linked to original sources

Rib cage contribution to resting and carbon dioxide stimulated ventilation during 1 MAC isoflurane anaesthesia.

Using respiratory inductive plethysmography, we have measured rib cage and abdominal motion during isoflurane anaesthesia in 16 healthy day-surgery patients. Anaesthesia was induced with propofol and maintained with 1 MAC isoflurane in air-oxygen via a laryngeal mask. Measurements were taken during both resting ventilation and hyperpnoea induced by rebreathing carbon dioxide. For resting ventilation, the rib cage contributed a mean (SD) of 33 (15)% of the total ventilation whilst awake, and 39 (12)% during anaesthesia (ns). With increasing end-tidal carbon dioxide whilst awake, the subjects showed a mean increase in the percentage rib cage contribution of 7.1 (12.5)%/kPa of carbon dioxide. With isoflurane anaesthesia, there was significant depression of this rib cage recruitment with the mean contribution decreasing by 3.6 (7.4)% kPa-1 (P less than 0.05). These results indicate that 1 MAC of isoflurane does not selectively depress rib cage motion, except during carbon dioxide stimulated hyperpnoea.

Abdominal Muscles↗

Comparison of oxygen consumption measurements: indirect calorimetry versus the reversed Fick method.

OBJECTIVE: To compare measurement of oxygen consumption (VO2) by spirometry and the reversed Fick method. DESIGN: Within-patient comparison using simultaneous measurements by the two methods, one previously calibrated on a metabolic simulator. PATIENTS: Twenty sets of observations on eight patients (57 to 83 yrs) requiring mechanical ventilation in a critical care unit. INTERVENTIONS: None during or immediately before the measurements. MEASUREMENTS AND MAIN RESULTS: Duplicate pairs of measurements of VO2 were made with a previously validated spirometric technique and the reversed Fick method (Qt[CaO2 - CVO2]), where Qt is cardiac output, CaO2 is arterial oxygen content, and CVO2 is mixed venous oxygen content. The coefficient of variation of the difference between duplicate measurements by the former technique was only 2.53% compared with 10.4% for the latter. The mean VO2 measurement by the spirometric method was 285.7 +/- 40.7 (SD) mL/min standard temperature and pressure, dry (STPD) and for the reversed Fick method, the mean VO2 measurement was 249.3 +/- 38.5 mL/min STPD. The mean difference was 36.4 +/- 28.5 mL/min STPD (p less than .001). CONCLUSIONS: The repeatability of the spirometric method was four times better than the reversed Fick method. The latter gave a significantly lower value that probably, in part, reflects the VO2 of the lung, which is included in the spirometric method but not in the reversed Fick measurement.

Aged↗

Respiratory function and ribcage contribution to ventilation in body positions commonly used during anesthesia.

Lung function tests are normally performed in the upright position, whereas anesthesia is usually administered with the patient in the supine position, and occasionally in other postures. We therefore compared forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), functional residual capacity (FRC), and ribcage contribution to ventilation by respiratory inductive plethysmography in 13 conscious healthy male volunteers, sitting and in four horizontal positions used during anesthesia. Forced vital capacity and FEV1 were similar in all positions, except for a significant mean increase in FVC of 300 mL (SD 213) when sitting compared with when supine (P less than 0.001). The mean decrease in FRC was 806 mL (SD 293) between the sitting and supine positions (P less than 0.001). A significant increase in FRC occurred (252 mL, SD 329, P less than 0.01) when supine subjects raised their arms above their heads as required for computed tomography. Functional residual capacity in the prone and lateral positions was significantly larger than in the supine position (mean change 350 mL, P less than 0.001), but was still some 450 mL less than in the sitting position. Mean ribcage contribution was similar in all horizontal positions (32%-36%), whereas supine values were significantly different from those of the sitting position (mean 70%, SD 11, P less than 0.001). In conclusion, the various horizontal postures studied have no effect on FVC, FEV1, or ribcage contribution to ventilation. However, FRC in the prone, lateral, and arms-up positions is on average 250 mL larger than in the supine position, an observation that may affect gas exchange during anesthesia in these positions.

Adult↗

Radiological study of the Laryngeal Mask.

Lateral soft-tissue radiography was used to determine the location of the Laryngeal Mask (LM) in relation to the larynx and surrounding structures in 24 elderly male patients undergoing general anaesthesia. In a majority of cases (16 of 24) the epiglottis was within the cuff of the mask but without causing discernable airway obstruction in any case. One case of backfolding of the cuff occurred, and there was one case of gross misplacement (also clinically undetected). Supplementary information was obtained in 13 patients by the use of fibre-optic endoscopy, via the lumen of the LM, confirming the inclusion of the epiglottis within the mask and demonstrating a characteristic distortion by the LM of the normal laryngeal anatomy. It is concluded that inclusion of the epiglottis within the LM is commonplace, and misplacements may occur without clinical evidence of a compromised airway.

Anesthesiology↗

Evaluation of metabolic measuring instruments for use in critically ill patients.

We evaluated three commercial indirect calorimetry devices which are used during artificial ventilation. Commercial butane, which had an RQ of 0.615, consumes 6.40 ml oxygen, and produces 3.94 ml CO2/1 ml, was burned in a gas-tight combustion chamber in conjunction with the ventilation of a lung model. During combustion, the flow rate of butane was measured with a soapfilm flowmeter for the calculation of reference values of oxygen consumption (VO2) and CO2 production (VCO2). To investigate the effect of oxygen concentration on the accuracy of these instruments, measurements were carried out at FIO2 values of 0.3, 0.4, 0.5, and 0.6 with a fixed ventilation mode (tidal volume 500 ml; respiratory rate 16 breath/min, intermittent positive-pressure ventilation). For the Datex Deltratrac Metabolic Monitor, the mean relative errors of measured VO2, VCO2, and RQ were all within 4.0%, 2.9%, and 4.0%, respectively. For the Engstrom Metabolic Computer, the corresponding values were 1.4%, 5.7%, and 6.0%, and for the SensorMedics MMC Horizon, 5.7%, 2.9%, and 5.9%.

Calorimetry↗

Time course of changes in lung permeability and edema in the rat exposed to 100% oxygen.

Rats were exposed to 100% oxygen for up to 60 h to determine early changes in lung permeability leading to the development of pulmonary edema. The time course of development of increased solute flux was assessed by the clearance of 99mTc-labeled diethylenetriamine pentaacetate (99mTc-DTPA) from the lung and the accumulation of 125I-labeled albumin (125I-albumin) in the lung. These end points were related to the development of pulmonary edema by the measurement of the wet-to-dry weight ratio of the lung and the weight of fluid in the pleural cavity. No significant changes occurred until 48 h of hyperoxia, when sharp increases in both indexes of lung permeability and wet-to-dry weight ratio occurred. By 60 h of exposure, pleural effusions had developed. The volume of this effusion was significantly correlated to both 99mTc-DTPA clearance and 125I-albumin flux.

Albumins↗

Short term effect of nitrous oxide on methionine and S-adenosyl methionine concentrations.

Concentrations of methionine and S-adenosyl methionine (SAM) have been measured in various tissues of rats exposed to 50% nitrous oxide for periods up to 80 min, a time by which there is detectable interference with thymidine synthesis in bone marrow. There were no significant changes of either SAM or methionine in plasma, whole blood or brain. Hepatic SAM was unchanged, but there was a highly significant reduction in hepatic methionine, to 62% of control, after 80 min exposure to nitrous oxide.

Animals↗

The laryngeal mask airway. A study of 100 patients during spontaneous breathing.

A prototype size 3 laryngeal mask was used in 100 patients by 18 anaesthetists with no previous experience of its use. A clear and unobstructed airway was obtained in 98% of patients, without requiring support of the jaw, thus leaving the anaesthetists' hands entirely free. The patency of the airway did not deteriorate during the course of the anaesthetic. In 10 patients there was obstruction of the airway at the first attempt to place it without the introducer and this obstruction appeared to be as a result of downfolding of the epiglottis. Subsequent attempts at passage were successful in all 10 patients. The seal between the mask and the larynx was adequate for artificial ventilation of the patients, but the mean leak pressure was 1.7 kPa.

Anesthesia↗

The oesophageal detector device. A prospective trial on 100 patients.

Misplacement of a tracheal tube in the oesophagus remains a significant cause of mortality and morbidity in anaesthesia, despite decades of effort aimed at prevention, or perhaps more importantly, detection, of such an event. We have evaluated a cheap, simple and quick device which relies mainly on the reflation or otherwise of an Ellick's evacuator applied to the supposed 'tracheal' tube. Identical tracheal tubes were passed into the trachea and oesophagus of 100 patients; the left and right position in the mouth was chosen at random. The test was conducted by a second anaesthetist, not present at intubation, and unaware of which tube was in the trachea. There were no false positive results and the correct deduction of which was the tracheal tube was reached in 100 tests using this device. Its use is recommended for widespread evaluation as a valuable adjunct to existing methods of detecting misplacement.

Adolescent↗

Validation of oxygen consumption measurements during artificial ventilation.

We describe a system for the absolute calibration of indirect calorimeters, under the conditions of artificial ventilation and increased inspired O2 concentration, in which butane, at a measured flow rate, is burned downstream of an artificial lung. One milliliter of butane requires 6.4 ml O2 for its combustion, and the respiratory quotient is 0.615. With the closed-circuit O2-replenishment method there was no significant systematic error in the measurement of either O2 consumption or CO2 output and a random error with a SD of 8.3 ml/min for O2 consumption and 6.3 ml/min for CO2 output. There were no significant differences in the errors with inspired O2 concentrations between 23.8 and 59.5% and O2 consumptions between 89 and 366 ml/min.

Butanes↗

Rate of inactivation of human and rodent hepatic methionine synthase by nitrous oxide.

The rate of inactivation of hepatic methionine synthase by nitrous oxide has been determined in 22 patients undergoing laparotomy during general anesthesia, including 70% nitrous oxide. Mean half-time of inactivation was 46 min. Metabolic consequences of nitrous oxide are, thus, critically dependent on the duration of anesthesia, and are unlikely to be significant during exposures of less than 40 min. Inactivation of methionine synthase is very much more rapid in the rat exposed to 50% nitrous oxide, with a half-time of 5.4 min.

5-Methyltetrahydrofolate-Homocysteine S-Methyltran↗