Visceral collateral arterial circulation: another cause of ureteral notching.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to J F Norfray.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVE: Clinical evaluation of shoulder pain can be difficult. Pain in the shoulder is often dynamic/positional, and it can often be elicited only during specific activity or function. Soft tissue deforms or changes in shape through motion. These complex interrelationships at the glenoid humeral joint require dynamic studies to accurately evaluate normal anatomy and abnormal pathology. The objective of our study was to evaluate the use of a dynamic cyclic cine imaging to evaluate the glenoid humeral joint. MATERIALS AND METHODS: Kinematic MRI was performed using axial 5 mm sections of the gradient echo and dedicated shoulder surface coil. The patient's arm was placed in the Bonutti cine shoulder system and allowed fixed incremental rotational movement of the shoulder at 10 degrees intervals. Images were reformatted onto a dynamic cine motion by oscillating from internal to external rotation then back to internal rotation. A total of 24 asymptomatic shoulders and 35 symptomatic painful shoulders were studied. RESULTS: Normal variations in the glenoid labrum were readily identified. The glenoid labrum in external rotation is taunt and triangular with well-identified capsular attachments. In neutral rotation the labrum often has increased signal and the middle glenoid humeral ligament occasionally blends with the labrum, making identification difficult. In maximum internal rotation the labrum is rounded and occasionally infolded. Variations in signal through the labrum are not indicative of tears. Capsular attachment must be followed from maximum internal to external rotation to identify stripping. The middle and inferior glenoid humeral ligaments often blend with labrum and internal rotation; however, in external rotation they can be identified as distinct and separate structures. Subcoracoid impingement can be identified in maximum internal rotation with a narrowing of the subcoracoid space to < 11 mm and buckling of the subscapularis and lesser tuberosity against the coracoid process. CONCLUSION: Accurate evaluation of the capsular/labral complex requires cine studies for accurate diagnosis. Signal changes alone or labral morphology alone varies through rotation, and static MRI does not accurately assess these morphologic changes, which vary with extremity position. Capsular attachments can be identified with cine studies accurately and reproducibly. Subcoracoid impingement can be identified with a narrowing of the coracohumeral distance to < 11 mm in internal rotation, which is suggestive of pathology.
PURPOSE: The intracranial lesions of neurofibromatosis type 1(NF-1) have variable pathology and growth based on molecular genetics. Because of this variable pathology and growth, the lesions are followed by sequential MRI. Our hypothesis was that MR spectroscopy (MRS) could provide a noninvasive neurochemical biopsy of NF-1 lesions, thereby distinguishing the different lesions, monitoring their variable growth, and having added value when compared with MRI. METHOD: Nineteen patients fulfilling the National Institutes of Health criteria for NF-1 were followed with sequential MRI and short TE proton MRS. MRI monitored the lesions by observing the area of prolonged T2, mass effect, and degree of enhancement. MRS monitored the lesions by following the level of neurons, cellularity, and a by-product of the inositol signaling pathway. A comparison was made between the MRI and MRS findings to determine if MRS provided added value. Sixty-nine spectra were obtained in 24 resions. RESULTS: MRI was able to identify hamartomas, gliomas, and indeterminate lesions. MRS was able to distinguish three distinct spectra when compared with the cellularity of normal deep white matter (DWM): a hamartoma spectrum with a choline/creatine (CHO/CRE) ratio below 1.5, a transitional spectrum with a CHO/CRE ratio above 1.5 and below 2.0, and a glioma spectrum with a CHO/CRE ratio above 2.0. On comparing MRS and MRI, MRS provided added value by identifying changes in cellularity while MR images were stable, identifying spectra that could distinguish hamartomas from gliomas, and identifying a transitional spectrum that could progress or regress into glioma or hamartoma spectrum. CONCLUSION: MRS was able to identify three distinct spectra in NF-1 lesions when compared with the cellularity of normal DWM, thereby providing a neurochemical means to characterize lesions.
Metallic extracranial carotid vascular clamps of the Selverstone, Crutchfield, Poppen-Blaylock, Salibi, Kindt, and tantalum varieties have been placed for treatment of large, giant, or inoperable intracranial aneurysms. To ascertain what adverse effect, if any, MR imaging would have on these clamps, magnetic deflection at 1.5 T was measured for various carotid clamps. Marked magnetic deflection (and torque) was displayed by stainless steel Poppen-Blaylock clamps. Relatively mild magnetic deflection was displayed by the stainless steel Selverstone, Salibi, Crutchfield, and Kindt clamps. Three patients with previously placed carotid clamps (two Selverstone, one Salibi) and one patient with a nonferromagnetic tantalum carotid clip had cranial or cervical MR studies at field strengths ranging from 0.35 to 0.60 T. No patient experienced any discomfort or neurologic sequelae as a result of MR imaging. Although the ferromagnetic clamps created severe "black-hole" artifacts and image distortion within the cervical and facial regions, no significant image degradation was apparent during spin-echo imaging of the brain. The tantalum clip created a far smaller MR artifact than did ferromagnetic clamps and allowed effective spin-echo and gradient-echo imaging in the cervical region. Our findings indicate that most patients with carotid vascular clamps (and nonferromagnetic clips) can probably be imaged safely with MR.
Explore the source record for details and available documents.
Brain iron was visualized on a mid-field (0.5 T) scanner using a spin-echo pulse sequence. Methemoglobin was hyperintense on T1- and T2-weighted images. Deoxyhemoglobin, hemosiderin, and ferritin were seen as decreased intensity on T2-weighted images. The spin-echo pulse sequences were improved for identification of deoxyhemoglobin, hemosiderin, and ferritin by prolonging the TR to 3000 msec and the TE to 80-120 msec. Phase-encoding artifacts at the level of the sylvian fissures caused increased noise, obscuring the brain iron in the lentiform nuclei with the TE of 120 msec. This artifact was substantially reduced or eliminated by lowering the TE to 80 msec, changing the phase-encoding gradient to the Y axis, or using additional pulsing in the slice and read gradients. Use of either the improved spin-echo or gradient-echo pulse sequences on a mid-field MR scanner provides improved evaluation of brain iron.
In patients with Parkinson disease, improved visualization of brain iron on a mid-field-strength magnet can be obtained with T2-weighted images and elimination of phase-encoding artifacts. A long echo delay time accentuates the loss of signal from brain iron. However, the long pulse sequence creates phase-encoding artifacts from CSF pulsations at the level of the basal ganglia. These artifacts are eliminated and resolving power increased with additional pulsing in the slice-selective and read gradients. Elimination of motion artifacts enhances visualization of brain iron in three ways: (1) extrapyramidal nuclei containing iron have better definition, (2) abnormalities are better identified, and (3) pseudolesions disappear. Our findings suggest there is significant improvement in the resolving power of brain iron on MR scans made with a mid-field-strength scanner when gradient modification is used.