Animal study on surface-modified defibrillator systems: Indications for enhanced infection resistance.

One of the most important problems with ICD systems is infection. The aim of this study was an in vivo evaluation of the efficacy of defibrillator systems in terms of infection resistance. The polyurethane leads were coupled with heparin and loaded with the antibiotic gentamicin, while the PGs were modified to release gentamicin. Group I was comprised of 10 pigs implanted with either a standard or a modified system for 2 weeks; group II was implanted during 4 weeks. The lead was inserted into the heart wall via the jugular vein. The other end was subcutaneously tunneled to the armpit where the PG was positioned. A cocktail of Staphylococcus aureus and epidermidis was injected at the site of the PG. Evaluation was performed macroscopically, by taking bacterial swabs during explantation and by microscopic processing. The results showed that 3 out of 5 modified defibrillator-systems in group I and 1-2 out of 5 in group II were judged as noninfected, whereas all standard systems were infected. Infection rates of the remaining modified defibrillators showed variances, as found with the standards, from slight to moderate to high, to even high/severe in group II (1x standard and 1x modified). With the modified systems, this may be related to production of humoral factors by an intensified early tissue reaction, as indicated by a swelling at day 6 at the site of the PG. When infected, whether or not modified, usually only Staphylococcus aureus was present. Spreading of infection seemed to occur by inoculation via blood, for example, based on the observation that group II in general showed an increase in infected fibrotic overgrowth in the heart, while infectious problems were low in the jugular vein. It is concluded that the modification at short term shows enhanced infection resistance. An increased infection rate already at 4 weeks, however, indicates that the modification may not hold in the long run. Special attention is needed concerning the more intense early tissue reaction.

Animals↗

Development of acute ischemic heart failure in sheep.

The goal of the present study was to develop a large animal model of acute ischemic left ventricular heart failure (LVHF) that can be used to assess the influence of the PUCA pump on the heart and circulatory system under realistic conditions. We tested the hypothesis that mild stenosis of the coronary artery in combination with mild ventricular pacing induces an acute heart failure condition, whereas the separate phenomena themselves do not lead to impaired heart function. Mean aortic pressure (AoP), left ventricular end-diastolic pressure (LVEDP), stroke volume (SV) and myocardial systolic shortening (MSS) were compared 30 minutes after a pacemaker (PM) induced tachycardia in anaesthetized sheep (n=3) without and with +/- 50% stenosis of the proximal LCx. All parameters measured restored to basic levels when stenosis was absent. When the LCx was partially occluded, mild PM-induced tachycardia resulted in decreased AoP (P=0.045) as well as in decreased SV (P=0.048); the LVEDP remained high (P=0.002). Also the recovery of MSS was impaired when stenosis was present (P=0. 002). These values indicate that acute heart failure conditions were present. The technique used proved to be safe and allowed fine-tuning of the demand ischemia by adapting heart frequency to the required heart failure conditions. The model can be used to study the effect of LV mechanical support during acute heart failure conditions.

Acute Disease↗

In vivo and in vitro experience with the PUCA-II, a single-valved pulsatile catheter-pump.

The Pulsatile Catheter (PUCA) pump is a trans-arterial pulsatile ventricular assist device that can be used for short-term left ventricular support. The separate inflow and outflow valves in the first version of the device (PUCA-I) were replaced by a single inflow/outflow valve in the latest PUCA pump version (PUCA-II). The new combined valve was tested during in vitro (mock circulation) and in vivo experiments for valve leakage, flow resistance, and thrombus formation. During the in vitro experiments a maximum valve leakage of 6% during ejection and 21% during aspiration was found. The maximum flow resistance coefficient (K) was 4. The animal experiments demonstrated that the PUCA-II could be positioned within a few minutes into the left ventricle without X-ray guidance and without using a vascular graft. Thrombi were not found in the combined valve after total pump time of 3 hours, which proved the good washout of the valve. Initial experiments to position the pump in the right ventricle through the pulmonary artery were successful and contributed to the development of a new application for the device.

Animals↗

Validation in an animal model of the carbon 13-labeled mixed triglyceride breath test for the detection of intestinal fat malabsorption.

OBJECTIVE: To determine, in a rat model of fat malabsorption, the potency of the carbon 13-labeled mixed triglyceride ((13)C-MTG) breath test as a noninvasive, patient-friendly replacement for classic fat balance studies. STUDY DESIGN: Comparison of the percentage of fat absorption, detected by fat balance, with the (13)CO(2) recovery of the (13)C-MTG breath test in rats fed high-fat chow and varying amounts of the lipase inhibitor, orlistat (0, 50, 200, and 800 mg per kilogram of chow), for 5 days. RESULTS: On orlistat administration, total fat absorption decreased from 80.2% +/- 2.2% to 32.8% +/- 3.7% (mean +/- SEM, 0 mg and 800 mg of orlistat per kilogram of chow, respectively; P <.001). Correspondingly, breath (13)CO(2) recovery from (13)C-MTG at 6 hours decreased from 84.5% +/- 7.8% to 42.0% +/- 1.5% of the dose (0 mg and 800 mg of orlistat per kilogram of chow, respectively; P <.001). The 6-hour recovery of breath (13)CO(2) appeared to be highly correlated with the percentage of fat absorption (r = 0.88, P <.001). In rats with fat absorption higher than 70%, however, the coefficient of variation of the (13)C-MTG breath test was 3-fold larger than that of the fat balance. CONCLUSIONS: The (13)C-MTG breath test could potentially replace the fat balance method for comparing fat absorption efficacy between groups. Yet, a considerable interindividual variation of the (13)C-MTG breath test under conditions of relatively mild fat malabsorption does not support its application for diagnostic purposes in individuals.

Animals↗

Evaluation of the optimal driving mode during left ventricular assist with pulsatile catheter pump in calves.

The pulsatile catheter (PUCA) pump, a left ventricular assist device, was tested during acute experiments in calves using asynchronous and ECG-synchronous assist modes. The aim of the study is to compare ECG-synchronous and asynchronous assist and to find the optimal driving mode for the PUCA pump with respect to left ventricular myocardial oxygen consumption (LV MVO2), pump flow, and coronary flow. LV MVO2 decreased significantly during the asynchronous (from 7.77 to 6.46 ml/min/100 g) as well as during the ECG-synchronous mode (from 8.88 to 7.84 ml/min/100 g). The pump flow was highest during the ECG-synchronous assist (2.94 L/min), followed by the asynchronous assist (2.79 L/min). The peak coronary flow depended strongly on pump ejection timing and showed the best flow patterns during the ECG-synchronous assist. We concluded that for PUCA pump support both asynchronous and ECG-synchronous assists significantly reduce LV MVO2 and that the pump flow generated is enough to maintain the systemic circulation. However, we find the ECG-synchronous mode preferable because this mode optimizes coronary flow patterns at the same time.

Animals↗

Development of a new introduction technique for the pulsatile catheter pump.

The pulsatile catheter (PUCA) pump is an intraventricular blood pump that can be introduced into the left ventricular cavity through a superficial artery (transarterially) or directly through the thoracic aorta during open chest conditions. When positioned, the pump aspirates blood from the left ventricle and transports it into the ascending aorta. A pneumatic driving system allows the blood to be ejected in early diastole of every second or third heart beat. The main goal of this study was to develop an easy, fast, safe surgical introduction technique. Four different means of catheter introduction were tested in 20 acute open chest experiments with calves: introduction without any guidance at all, introduction by x-ray guidance only, introduction using a guide wire plus x-ray guidance, and introduction using a guiding pressure catheter. Introducing the PUCA pump catheter into the left ventricular cavity using a pigtail guiding pressure catheter proved to be easy. The large bore pump catheter followed the guiding catheter and passed the aortic valve well. The position of the PUCA pump could be monitored from the pressure patterns derived from the guiding catheter.

Animals↗

In-vivo evaluation of the "HIA-VAD": a new German ventricular assist device.

Helmholtz Ventricular Assist Devices (VAD) are pneumatically driven polyurethane membrane pumps with various volumes. The pumps are placed paracorporeally and connected with commercially available cannulas between the left atrium and aorta (left ventricular assist device) and/or right atrium and pulmonary artery (right ventricular assist device, bi-ventricular assist device). The pumps can be driven with a stand-alone driving system or with a Helmholtz IABP-console interface. Seventeen animal experiments (on calves) with Helmholtz VAD's were performed to evaluate experimental protocols, to optimize surgical techniques, and to improve design and manufacturing techniques. Blood chemistry and cell counts demonstrated that the tested HIA-70 produces low mechanical blood damage. In the course of the animal experiments the Helmholtz VAD's were made totally transparent, whereby they became easy to de-air, efficient, and affordable.

Animals↗

An automatic autotransfusion system with a centrifugal pump: a hematologic evaluation in dogs.

The requirements that have to be met by an on-line autotransfusion system (ATS) in case of massive blood loss are a sufficient capacity for reinfusing the shed blood, an optimal hemocompatibility, ability to prevent reinfusion of aspirated air, and ease of operation. In a previous study we tested a diaphragm pump in our pneumatically driven ATS that met these requirements. In this study a centrifugal pump was used as an outflow pump in otherwise the same system. A centrifugal pump has important advantages: It prevents the occurrence of massive air embolism, accidental obstruction of the outflow line will not cause bursting of the tubing, and there is no spallation. There are also indications that a centrifugal pump causes less stimulation of the coagulation cascade than do other pumps. Because of these advantages, we were interested in the hemocompatibility and pumping characteristics of the centrifugal pump in our ATS. From this study we conclude that the hemocompatibility of the centrifugal pump was not significantly different from that of the previously tested diaphragm pump. Also, the system can easily and safely be operated by non-specialized personnel. Because of the advantages, especially in pumping characteristics, the centrifugal pump is our choice in on-line ATSs.

Animals↗

[Regional isolation perfusion with cisplatinum in dogs with osteosarcoma of an extremity].

In the treatment of osteosarcoma, it is possible to differentiate between systemic therapy and local regional treatment. Systemic treatment of human patients with osteosarcomas consists in adjuvant chemotherapy. This has considerably improved the prognosis in these cases. The primary object in local regional treatment is to prevent local recurrences and to preserve function. As regards extremities, the aim is to preserve the limbs. In the present investigations, the value of regional chemotherapy by isolated regional perfusion with cis-platinum to dogs is studied. This approach was based on the hypothesis that considerable necrosis of tumours may be produced after perfusion with cis-platinum, thus making extremity-saving surgery possible. Isolated regional perfusion with cis-platinum (30 mg/litre of extremity volume) was performed in nine dogs with osteosarcomas of an extremity. A marked effect on the tumour was detectable on the basis of clinical, radiological and histological parameters. In the opinion of the present authors, regional perfusion with cis-platinum may contribute to extremity-saving treatment of osteosarcomas in dogs and human subjects. However, further studies will be required in order to achieve more adequate quantitation an improvement of local effects. In view of the synergy with cis-platinum, the latter may possibly be attained by the addition of hyperthermia (temperatures above 41.5 degrees C).

Animals↗

Prevention of infection in a porous tracheal prosthesis by omental wrapping.

The ideal tracheal prosthesis has to permit complete incorporation by epithelialization of the luminal surface. This is not possible with the currently available impermeable solid silicone tube. The authors developed a reinforced, porous polyurethane tubular prosthesis which has the potential for complete incorporation. However, because these prostheses are implanted in a contamined area such as the airway, they all become infected. In order to prevent infection, the authors evaluated the effect of omental wrapping in guinea pigs. The authors' tubular prosthesis was implanted subcutaneously in the abdominal area with the ends open to the air. Ten prostheses were wrapped with omentum and 10 prostheses were not. In 4 weeks, all control prostheses were infected and marsupialized. All the wrapped prostheses remained in place and were macroscopically not infected. Microscopically, all wrapped prostheses were well vascularized and were incorporated by granulation tissue, which did not occur in the prostheses of the control group. From these results the authors conclude that omental wrapping would be an effective way to prevent infection of porous tracheal prostheses in an open-to-the-air situation, and allow rapid tissue ingrowth and incorporation in the host.

Animals↗

A novel implantable electromechanical ventricular assist device. First acute animal testing.

A novel ventricular assist device (HIA-EMLVAD-AT1, Helmholtz Institute Aachen-Electromechanical Left Ventricular Assist Device-Animal Test Version 1), driven by a uniformly and unidirectionally rotating actuator and a patented hypocycloidic pusherplate displacement gear unit, was developed and tested in an acute animal experiment. The excellent free filling behavior of the pump chamber with a stroke volume of 65 ml is obtained by a 2:3 ejection-filling time relationship. The uniform motor rotation facilitates simple sensorless pre and afterload detection by motor current analysis. In contrast to common apical cannulation, the inlet cannula was placed via the left atrium through the mitral valve into the left ventricle. This connection mode is preferable for left ventricular recovery and preservation. Left atrial, left ventricular, and aortic pressure curves, as well as pulmonary artery flow data, were obtained. The data show very effective unloading of the natural ventricle and demonstrate the feasibility of this novel assist device. Directions for further improvement of technical features were also identified.

Animals↗